Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.7 L+₹2,565 (0.16%)Rejected-Finance 00 C O PARMOD SINGH BAKTA BARHI CHINTAMAN SITAMARHI BIHAR 843315 | SITAMARHI | BIHAR | 843315 | L2 | Rejected-Finance BEING L2 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
29 Apr 2022, 6:00 pmClosed
GE AF THANE
Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR, MAINTENANCE OF INTERNAL WIRING, FITTING FIXTURE, CEILING, EXHAUST, PADESTRIAL FAN,SUB MAIN INTERNAL WIRING SERVICES CONNECTION,DISTRIBUTION BOARD,BUILDING EARTHING AND ALLIED WORK AT SITE R UNDER GE AF THANE
2022_MES_516093_1
8180/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹40,000
Yes
7 Jun 2022
31 Mar 2022
30 Apr 2022
31 Mar 2022
29 Apr 2022
16 Apr 2022
31 Mar 2022 - 16 Apr 2022
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, sockets, light fittings, MCB DBs,out let boxes etc.removing material for taking credit and making good disturbed surfaces of walls, floors, ceilings etc,complete all as specified and as directed by Engr-in-charge.
M&L for consealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 V grade confirming to IS 694 drawn through PVC conduit of suitable size heavy grade ISI marked including necessary conduit accessories, sunken type pressed steel terminal boxes with plastic laminated sheet of approved shade 3mm thick including 1.5 mm PVC insulated flame retardant copper conductor as in continious earth wire ,complete all as specified and as directed by Engr-in-charge. for the following as given below:-
One Light/Bell/ceiling fan & exhaust fan point controlled by one switch .
One 3 pin 5 Amps socket out let on independent board
One 3 pin 5 Amps socket out let on same board
Ditto-All as per item No-2 above but with 2.5 Sqmm wire for 15 Amp socket outlet on independent board
M&L for point wiring with 1.5 Sqmm (nominal area) FRLSH insulated multi-stranded copper conductor confirming to IS 694 in and including Medium duty PVC casing capping (ISI marked) including fitting & accessories, with MS concealed terminal boxes with 3mm thick laminated BakeliteHylum sheet top cover for mounting switch, socket etc including 1.5 Sqmm stranded copper conductor with green PVC insulation earth continuity conductor 1.5 Sqmm connected to the common earth dolly and controlled by one switch ,complete all as specified and as directed by Engr-in-charge. Make of Cable – HPL/Havells/ Polycab/Anchor/Finolex. for the following as given below:-
One Light/Bell/ceiling fan & exhaust fan point controlled by one switch .
One 3 pin 5 Amps socket out let on independent board
One 3 pin 5 Amps socket out let on same board
Ditto-All as per item No-4 above but with 2.5 Sqmm wire for 15 Amp socket outlet on independent board
Supply & Fix switch piano flush button single pole one way 5 Amps, 250 V ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix Bell push button flush type 5 Amps ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix switch piano flush button single pole one way 15 Amps, 250 V ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix socket outlet 2 in 1,3 pin, 5A flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix switch socket combination 2 in 1,3 pin, 5 Amps flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix socket outlet 2 in 1,6 pin, 5/15Amps flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix switch socket combination 2 in 1,6 pin, 5/15Amps flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix and fix bell buzzer, Ding Dong AC 230 volt single pole ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix fix bell multi music AC 230 volt single pole ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix fan regulator Electronic type step type for 400 watts ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix Modular switch 1 way 6A,1 modul, 220 V ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair, Modular switch 1 way 16A,1 modul, 220 V ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair, Modular socket 6A-2/3 pin combined 2 module flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair, Modular socket 6A/16A-2/3 pin combined 2 module flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair, Modular switch socket combination 16A,6 pin.3 module flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair, Modular Bell push button flush type 5 Amps ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair,Modular fan regulator Electronics step type 120 watts 2 module and connecting ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair,Modular white cover plate with frame suitable for 1 module ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair ,Modular white cover plate with frame suitable for 3 module ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair , Modular Metal flush box suitable for 1/2 modul. ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair ,Modular Metal flush box suitable for 3 module. ,complete all as specified and as directed by Engr-in-charge.
S & F ,in repair, Modular white cover plate with frame suitable for 4 module ,complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular white cover plate with frame suitable for 6 module ,complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular white cover plate with frame suitable for 8 module ,complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular Metal flush box suitable for 4 module ,complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular Metal flush box suitable for 6 module, complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular Metal flush box suitable for 8 module, complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S&F, in repair ,Ceiling rose, surface bakelite, 65mm x 50mm two to three terminals. ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair , capping casing 20mm width,complete all as specified and as directed by Engr-in-charge.
S&F, in repair , lamp holder,PVC/Polycarbonate type with back plate suitable for batten fitting ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of Batten type LED light fitting 1x18/20watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. ,complete all as specified and as directed by Engr-in-charge. Make: Havells/Wipro/Bajaj/C&S/Philips
S&F in replacement of Batten type LED light fitting 1x9/10 watt 2 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. ,complete all as specified and as directed by Engr-in-charge. Make: Havells/Wipro/Bajaj/C&S/Philips
S&F in replacement of Batten type LED decorative up to light fitting 15 watt round including LED bulb complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes complete all as specified and as directed by Engr-in charge. ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of energy efficient square surface/ceiling mounted LED down 2x2 luminaire 34/36 watt white powder coated CRCA housing with LED seamless front frame with flat white high transmission acrylic cover complete all as specified and as directed by the Engr- in- Charge. ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of energy efficient LED mounted panel 12 watt white powder coated CRCA housing with LED seamless front frame with flat white high transmission acrylic cover complete all as specified and as directed by the Engr- in- Charge. ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of LED bulding security light fitting of 25/30 Watt including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD (I) less than 10%, cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report. ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of Bolard light of 8 Watt in repair/replacement of existing lights including LED lamps totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of LED bulb 5/7/9 watt, 230 Volt, 50 Hz, complete all as specified and as directed by the Engr- in- Charge. complete all as specified and as directed by the Engr- in- Charge.
S&F in replacement of energy saver LED bulb 2.7 watt,E27 230 Volt, 50 Hz, complete all as specified and as directed by the Engr- in- Charge. complete all as specified and as directed by the Engr- in- Charge.
S&F in replacement of energy efficient DRONE LED 32 watt round complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes complete all as specified and as directed by Engr-in charge. ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of Energy saving 9/10 watt environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs, IP 65 protection fixed on wall complete all as specified and as directed by Engineer-in-charge.
Taking down the ceilling fan/wall mounted fan,Exhaust fan from ceilling,wall,cleaning the dust,drit ,greashing,servicing ,repairing and refixing the original position ,complete all as specified and as directed by Engr-in-charge. Note:- Necessary spare for repairing will be measured and paid in respective items.
Re winding ceilling fan with super enameled copper wire suitable gauge to get designed condition of speed for the particular make of fan including insulating, varnishing, providing sleeves to copper wire and testing for good running condition of sweep1200/1400 mm ,220 volt ,50 HZ,single phase ,complete all as specified and as directed by Engr-in-charge.
Re winding Exhaust fan with super enameled copper wire suitable gauge to get designed condition of speed for the particular make of fan including insulating, varnishing, providing sleeves to copper wire and testing for good running condition of sweep 230/300/400 mm ,220 volt ,50 HZ,single phase
Re winding wall mounted fan with super enameled copper wire suitable gauge to get designed condition of speed for the particular make of fan including insulating, varnishing, providing sleeves to copper wire and testing for good running condition of sweep 400 mm ,220 volt ,50 HZ,single phase ,complete all as specified and as directed by Engr-in-charge.
Supply only Gun metal bush suitable for particular make of fan of 1200mm /1400 mm sweep ,complete all as specified and as directed by Engr-in-charge.
Supply only metal bush suitable for particular make of exhaust fan of 400 mm sweep ,complete all as specified and as directed by Engr-in-charge.
Supply only ball bearing suitable for particular make of fan of 1200 mm /1400 mm sweep ,complete all as specified and as directed by Engr-in-charge.Make for Bearing - NBC/Tata/SKF
Supply only ball bearing suitable for particular make of exhaust fan of sweep 300mm/450 mm complete all as directed Make -SKF/NBC/SKF
Supply only 2.5 Mfd/3.5 Mfd capacity Make ,complete all as specified and as directed by Engr-in-charge. Make : Havells,HPL, Asian.
Supply only ceiling fan blade for 1200 mm /1400 mm sweep fan as per existing ceiling fan and all as directed by Engr-in-Charge.
Supply only Ceiling fan canopy as per existing and all as directed by Engr-in-Charge.
Supply only anti sucidal downrod suitable for ceiling fan of any sweep and all as directed by Engr-in-Charge.
Supply only downrod suitable for ceiling fan of any sweep and all as directed by Engr-in-Charge.
Supply only Capacitor 4Mfd suitable for exhaust fan of sweep 300mm/450mm complete all as directed. Make :Havells,HPL, Asian.
Checking of ceiling fan of any sweep ,any type for fixing arrangement including replacement of stainless steel nut ,bolt with double washer,ruber reel & quarter pin as per site including oiling for ceiling fan and making record by taking signautre of users/occuptant by the contractor all as directed by Engr-in-Charge.(Note- This items includes the cost the rubbber reel,ss nut,bolts with double washer & quarter pin nothing extra shall be in this account)
Dismantling all electronic meter from existing panel and refixing in new after testing, S&F single phase multi meter mounting box (650 mm x 450 mm x 150 mm) for mounting 04 Nos electronic meter, shockproof and rustproof, termit restistant, cable entry from bottom side, 100 % weather proof, pole mounting arrangment, temper and pilferage proof, fire retardent-class FV-0 as per IS 11731 part-II or V-0 as per UL-94 complete all as specified and directed by Engineer-in-Charge. Make- Sintex
Supply and fixing ceilling fan 5 star rated, 1200 mm sweep ,220 volt ,50 HZ,single phase, all as directed. ,complete all as specified and as directed by Engr-in-charge.
Supply and fixing wall mounted fan 5 star rated., 400 mm sweep ,220 volt ,50 HZ,single phase, ,complete all as specified and as directed by Engr-in-charge.
Material and labour for earth pit chember of size 0.6mx0.6mx0.6m made with PCC 1:2:4 type B-2 including HDPE earthing pit cover inspection chember of size 200 mm depth, 300mm length and300mm width ,complete all as specified and as directed by Engr-in-charge.
Material and labour for Brazzing of copper earth strip 20/25/32 mm with available at site and reconnected properly ,complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable and dislocated Copper/aluminium strip of any size from floor of any size height ,complete all as specified and as directed by Engr-in-charge.
S&F,in repair, copper strip of 20 x 3.15 mm as roof conductor and down conductor till test point all as directed. Note-Copper strip to be jointed through brazing only ,complete all as specified and as directed by Engr-in-charge.
S&F,in repair, aluminium strip of 25 x 3.15 mm as roof conductor and down conductor till test point all as directed. Note-Galvanised strip to be jointed through brazing only
Taking down unserviceable and dislocated air termination rod of any type from floor of any size ,complete all as specified and as directed by Engr-in-charge.
S&F,in repair, single pointed soild copper rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/down conductor ,complete all as specified and as directed by Engr-in-charge.
S&F,in repair, single pointed soild Aluminium rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/dowen conductor ,complete all as specified and as directed by Engr-in-charge.
S&F Porcealing insulators in replacement for fixing Copper strip on wall / Roof bldg with necessary screws washers and nut bolts etc all Specified . Note - Rates are inclusive of copper screws with washers for fixing copper strip on porciline insulator with minimum size 1 inch and maximum size 1.5 inch with max external dia of screw is 8mm and 2 nos of GI nut for fixing insulator on wall all as per site requirement ,complete all as specified and as directed by Engr-in-charge.
S&F,in repair,Medium grade GI pipe of 20 mm dia for fixing air termination rod, the pipe shall be suitably tapered for fixing the saddle insulator at an interval not exceeding 0.5 meter, the pipe should be laid vertically and should be properly supported, length of each vertically pipe should not exceed 3 RM, the air termination rod, down conductors should be insulated from the pipe all as directed.
Taking down unserviceable test point terminals block and supply and fixing the same. The terminal block made with gun metal size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex head of gun metal screw ,complete all as specified and as directed by Engr-in-charge.
M & L for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) excavation and earth work returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion.Note:1.After completion if test results are nor satisfied, earthing should be redone by contractor without any extra cost. 2. Contractor should quote the rate deemed to be included with testing.
M&L security light bracket made with GI pipe 40 mm dia light grade minium length 1.5 mtr long with 105 degree angle including necessary MS clamp made with 25mm x 6 mm and suitable MS studs and bolts, duly painted with two coats of aluminium paint over a coat of red oxide primer ,complete all as specified and as directed by the Engr- in- Charge. Rate - Including fixing clamp and anchor fasterner for GI Steel tubing.
Taking down sub main wiring of any size complete and making good disturbed surface of walls/floors etc ,complete all as specified and as directed by Engr-in-charge.
M & L submain wiring with two single core through FRLSH PVC insulated unsheathed stranded copper conductor 6 sqmm (nominal area) drawing through PVC coundit concealed and 4 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly Note : (i) Three lenght of wire along with conduit will be measured as one Length. (ii) Rates are deemed to include with cutting chases for conduit and sinking's for boxes and making good to walls, floors etc. ,complete all as specified and as directed by Engr-in-charge. Make: Make:Polycab/Havells/CCI/Gloster/KEI/Finolex
All as per item no 79.00 herein before but of size 2X4 sq mm and 1X2.5 sqmm
M & L submain wiring with two single core through FRLSH PVC insulated unsheathed stranded copper conductor 6 sqmm (nominal area) drawing through PVC capping casing and 4 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly Note : (i) Three lenght of wire along with conduit will be measured as one Lengt. (ii) Rates are deemed to included with cutting chases for conduit and sinking's for boxes and making good to walls, floors etc. Make: Make:Polycab/Havells/CCI/Gloster/KEI/Finolex
All as per item no 81 herein before but of size 2X4 sq mm and 1X2.5 sqmm
All as per item no 81 herein before but of size 2X10 sq mm and 1X6 sqmm
Taking down unserviceable DB/MCCB/MCB of any capacity and making good disturbed surface of wall/floor complete all as specified all as directed.
S & F LoadlineDistribution board, TP&N vertical, with Bus bars, 200A, 415V CapNetural links,blanking plates, double door 12 way, with MCCB 63 to 100 Amps as incommer and SP/DP/TP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge. Make : Havells/Benlo/Legrand/Standered/Schneider/Indo asian
S & F Loadline Distribution board, TP&N vertical, with Bus bars, 200A, 415V CapNetural links,blanking plates, double door 8 way, with MCCB 63 to 100 Amps as incommer and SP/DP/TP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge. Make : Havells/Benlo/Legrand/Standered/Schneider/Indo asian
S & F Loadline Distribution board, TP&N vertical ,with Bus bars, 200A, 415V Netural links,blanking plates, double door 4 way, with MCCB 63 to 100 Amps as incommer and SP/DP/TP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge. Make : Havells/Benlo/Legrand/Standered/Schneider/Indo asian
S & F Distribution board, SP&N ,Prewired ,Netural links,blanking plates, double door 6 way, with provision for MCB SP&N as incommer and SP/DP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge. Make : Havells/Benlo/Legrand/Standered/Schneider/Indo asian
S & F Distribution board, SP&N ,Prewired ,Netural links,blanking plates, double door 8 way, with provision for MCB SP&N as incommer and SP/DP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge. Make : Havells/Benlo/Legrand/Standered/Schneider/Indo asian
S & F Distribution board, SP&N, Prewired ,Netural links,blanking plates, single door 12 way, with provision for MCB SP&N as incommer and SP/DP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge. Make : Havells/Benlo/Legrand/Standered/Schneider/Indo asian
S & F MCB SP 6 to 32 Amps 240 volts 50 HZ having 10 KA ,complete all as specified and as directed by Engr-in-charge. Make : Havells/Benlo/Legrand/Standered/schneider/Indo asian
S & F MCB SPN 40 Amps 240 volts 50 HZ having 10 KA ,complete all as specified and as directed by Engr-in-charge. Make :Havells/Benlo/Legrand/Standered/schneider/Indo asian
S&F MCB SPN 240 volt,50Hz,63 Amp,C Curve,10kA breaking capacity ,complete all as specified and as directed by Engr-in-charge. Havells/Benlo/Legrand/Standered/schneider/Indo asian
S & F MCB TP 40 Amps 240 volts 50 HZ having 10 KA ,complete all as specified and as directed by Engr-in-charge. Make : Havells/Benlo/Legrand/Standered/schneider/Indo asian
S&F MCB TPN 415 volt 63 Amp,"C" Curve 16kA breaking capacity ,complete all as specified and as directed by Engr-in-charge. Make:Havells/Benlo/Legrand/Standered/schneider/Indo asian
S&F DB box with procted power unit rating 16-25 Amps 240volt 50HZ as per Havells cat part no-DHDUCDP0253016-25.Make : Havells or equivallent make of L&T/Legrand.
S & F RCCB DP 6 Amps 240 volts 50 HZ having ,complete all as specified and as directed by Engr-in-charge. Make : HavellsL&T/Legrand/ Standered/schneider/Benlo/Indo asian
Taking down the unserviceable MCCB, Supply and fixing MCCB TP pole with thermal Release range 40/63 Amps, 18KA, 415V, 50 Hz including extension bar for connection cable, ,complete all as specified and as directed by Engr-in-charge. Make : Havells/L&T/Legrand/ Standered/schneider/Benlo/Indo asian
Taking down the unserviceable MCCB, Supply and fixing MCCB TP pole with thermal Release range 100-125 Amps, 18KA, 415V, 50 Hz including extension bar for connection cable, ,complete all as specified and as directed by Engr-in-charge. Make : Havells/L&T/Legrand/ Standered/schneider/Benlo/Indo asian
Taking down the unserviceable MCCB, Supply and fixing MCCB TP pole with thermal Release range 160 Amps, 18KA, 415V, 50 Hz including extension bar for connection cable,,complete all as specified and as directed by Engr-in-charge. Make : Havells/L&T/Legrand/ Standered/schneider/Benlo/Indo asian
Taking down the unserviceable MCCB, Supply and fixing MCCB TP with thermal Release range 200/250 Amps bracking capacity 25KA, 415V, 50 Hz including extension bar for connection cable, ,complete all as specified and as directed by Engr-in-charge. Make : Havells/L&T/Legrand/ Standered/schneider/Benlo/Indo asian
Taking down the unserviceable MCCB, Supply and fixing MCCB TPN with thermal Release range 400Amps bracking capacity 25KA, 415V, 50 Hz including extension bar for connection cable ,complete all as specified and as directed by Engr-in-charge. Make : Havells/L&T/Legrand/ Standered/schneider/Benlo/Indo asian
Taking down and Supply and fixing insulating rubber mating chequare plate made out having electrical resistance of size 1000mmx2000mm with thickness 20mm suitable for use 22 KV working voltage,dielectric strength 40 kv with working temperature up to 50 degree centigrade ,complete all as specified and as directed by Engr-in-charge.
M&L for Earthing complete with copper earth plate electrode of size 600 x 600 x 3 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to & including copper earth strip of size 20X3mm dia by means of GI bolts, nuts, washers, and connected to other end to main board duly protected by 15 mm bore GI light grade pipe from earth plate. Earth plate shall be surrounded by packed layer of coal dust 300mm and common salt 15 cm thick all around bottom and top. Watering pipe 20 mm bore of GI medium grade pipe and including funnel, wire mesh, CI cover & frame, PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 5 of SSR Part – I. Rate are deemed to include 7.5 Mtr 20X3mm size copper strip Note : PCC/HDPE chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii). Earth resistance of earth pit should be less than 2 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of Copper plate. (iv) Soil investigation if required shall be carried out by contractor without any extra cost.
M & L for connecting 1100 volt grade heavy duty cable PVC insulated copper conductor, served with inner sheathing of PVC tap and over all PVC sheathed in service connction for street light from FRP junction box to street light of size 3 core 1.5 Sqmm . ,complete all as specified and as directed by Engr-in-charge. Make: Paragon/HPL/Havells
Disconnecting the incomming and out going cable connection from unserviceable high mast LT panel. Dismelting the all MCCB, and other control equiptment, Measuring instrutment, Bus bar and internal cable /copper strip connection. Cutting the worn out sheet/angle and fabricated the new MS sheet/angle with match the existing size and shape. Scrapping the existing paint and repainting painting of the panel board with one coat of red oxide paint as a primer with two coat of synthetic enamel paint to match the existing colour.Refxing the serviceable controll equiptments and connected all incomming/outgoing cables all as directed. Note: (a)The replacement of the unserviceable items and frame work will be measured and paid seperately in respective items.
Taking down the unserviceable and Supply and fix in replacement street light timer digital type with 24 Hours operation settings including ML-4 contractor 63 Amps Three phase 430 volt AC with Control wiring of 6 Sqmm copper wire with TPN MCB of 63 Amps , 10 KA and 20 Amps single phase backlite fuse including sheet metal enclouser of 2mm thick with powder coating with mounting arragenets, angle iron frame and PCC foundation etc,complete all as specified and as directed by Engr-in-charge.
Taking down the unserviceable Power contractor, Supply and fixing 4 pole Power contractor type MCX,AC-1,rating 63 Amps,ML-4 including necessary connection ,complete all as specified and as directed by Engr-in-charge. Make:-Indo asian /Havells/HPL/BENLO/L&T/Standard/Legrand/ABB/Schneider
Taking down the unserviceable Power contractor, Supply and fixing 4 pole Power contractor type MCX,AC-1,rating 45 Amps,ML-3 including necessary connection ,complete all as specified and as directed. Make:-Indoasian /Havells/HPL/BENLO/L&T/Standard/Legrand/ABB/Schneider
Supply, perform, testing, commissioning of LT cable straight through joint kit heat shrinkable of 4 core x 10/16/25 Sqmm size,complete all as specified and as directed by Engr-in-charge. Make : Denson / M seal /Raychem
M&L for PCC 1 : 3 : 6 type C1 with 20 mm stone aggregate for foundtation / concrete blocks / earthing chamber / chamber cover set in cement mortar 1:4 complete all as directed by Engineer-In-Charge
Supply and fix sheet steel enclosure for test terminal block of size 150x150 mm made out of 2 mm thick dully Powder Coated CRCA sheet for fixing test terminal block all as directed
Supply and fix in repairs for the following items to be incorporated in repairs to earthings
(a) Charcoal
(b) Common Salt
(c ) Funnel with wire Mesh
M & L for maintenance free chemical Gel based earthing, Pure Copper type having 50 mm dia 3 mtr long GI pipe(Wall thickness of 3.2 mm) and 7.50 m long Copper strip earthing electrode of size 25 x 3 mm with 60 Kg ENNOV back fill compound , Model No ELE-350-CU of INNOV Infra Solution Ltd including necessary excavation and earth work in any type of soil, perforated watering pipe, funnel with wire mesh, earth lead protection pipe light grade, PCC Chamber 1: 3 :6 type C1 ( for even finish on both the faces ) and RCC cover 1:2:4 type B1, 550 x 550 x 50 mm thick with 8 mm dia TMT bars 150 mm c/c both ways with 2 Nos of handles of 10 mm dia all as required at site including testing on completion and taking down of old earthing all as directed by Engr in-Charge Note : (1) 7.50 RM GI earth strip including GI pipe light grade is deemed to be included in the quoted rates, beyond 7.50 RM shall be measured and paid separately. (2) Earth resistance of earth pit should be less than 1.0 Ohms on testing after completion. If the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Supply and fixing HOT moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 280 x 200 with 32 Amp 4 way heavy duty terminal block with 10Amp MCB SP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole, including taking down existing ,complete all as specified and as directed by Engr-in-charge. .Make: Sintex/Hensel
M&L for periodical testing and measuring the earth resistance value of the existing earthings / Down conductor / air terminal by means of wheat stone bridge method after disconnecting the earth continuity conductor from the test point , applying secondary voltage across the terminals, maintaining proper record of the measurement in presence of the users rep, MES rep, submitting the test records, pouring saline water in the earth pit to achieve low earth resistance, observing the same complete for Quarterly Building earthings,L2/L3 eqpts/E&M installations/Lightning arresters test ,complete all as specified and as directed by Engr-in-charge.
M/S KHUSHI ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .