| Sl No | Description | Qty | Unit | Electromechanics Engineers And Contractors L3 | Akhil Enterprises L2 | GRD ENGINEERS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Repairing of damaged AMF Panel with synchronizing panel and replacing of damaged synchronizing relay volt meters, amp meters, CTs and control relays including painting of the AMF panel complete job (Make Schneider) | 1 | Job | 5,00,000 ₹5 L | 5,20,000 ₹5.2 L | 3,99,887 ₹4.0 L |
| 1.10Supply and fixing of 1250 ampre Air Circuit Breaker 50 K 4 Pole (EDO Type) in the existing panel board including dismentaling of old ACB with connection testing etc as requried 1No | ||||||
| 1.20Supply and fixing of 1000 ampre (Air Circuit Breaker) 50 K 3 Pole (EDO Type) in the existing panel board including dismentaling of old ACB with connection testing etc as requried 2 No | ||||||
| 1.30Supply and Fixing of 400 ampre 4 Pole 50 K MCCB in the existing panel board including dismentling of old MCCB with connection testing etc as req etc as requried 1 no | ||||||
| 1.40Repairing and replacement of damaged 1250 ampre bus bar in the existing panel 2.8 meter | ||||||
| 2.00 | Repairing of VCB control panel indoor type by way of replacing of charging motor,NONC coils and DC supply 12 volt 100 AH maintance free (MAKE SCHNEIDER) | 1 | Job | 88,887 ₹88,887 | 90,000 ₹90,000 | 88,887 ₹88,887 |
| 3.00 | Supply and fixing of CT/PT trivector meter panel Ratio 30/5 / PT 110 Volt including dismentling of existing panel complete job | 1 | No | 99,987 ₹99,987 | 67,000 ₹67,000 | 99,987 ₹99,987 |
| 4.00Supply and laying of PVC Power cable (HT) 3.3 KV Grade armoured aluminium XLPE cables including earth work, cost of end termination, thimbles and saddles etc. as required. | ||||||
| 4.10 | 120 sq mm x 3 core | 20 | meter | 1,187 ₹23,740 | 950 ₹19,000 | 1,187 ₹23,740 |
| 5.00 | Construction of platform with concreete base 1:3:6 of (10'- 0"X 4'- 0') 3'- 0" including excavation shuttering and refilling complete job | 1 | Job | 87,887 ₹87,887 | 15,000 ₹15,000 | 87,887 ₹87,887 |
Tender Value
₹24.5 L
EMD Value
₹48,980
Closing Date
14 May 2026, 4:00 pmClosed
Estates Officer, SKUAST-Jammu
Estates Division, SKUAST-J, Chatha
Electrical repair work by way of repairing of damaged AMF Panel with synchronizing panel and VCB panel and other allied work at Baba Jitto Auditorium at Main Campus, Chatha
2026_SKUST_309529_5
AU/Estates/2026-27/05 dated 07-05-2026
Open Tender
Electrical Works
90 days
Main Campus, Chatha
Please refer tender documents
4 documents required · 4 mandatory
₹1,000
Assistant Comptroller (Estates), SKUAST-Jammu
₹48,980
18 May 2026
8 May 2026
15 May 2026
8 May 2026
14 May 2026
8 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repairing of damaged AMF Panel with synchronizing panel and replacing of damaged synchronizing relay volt meters, amp meters, CTs and control relays including painting of the AMF panel complete job (Make Schneider) | 1 | Job | - | - |
| 1.1 | Supply and fixing of 1250 ampre Air Circuit Breaker 50 K 4 Pole (EDO Type) in the existing panel board including dismentaling of old ACB with connection testing etc as requried 1No | - | - | - | - |
| 1.2 | Supply and fixing of 1000 ampre (Air Circuit Breaker) 50 K 3 Pole (EDO Type) in the existing panel board including dismentaling of old ACB with connection testing etc as requried 2 No | - | - | - | - |
| 1.3 | Supply and Fixing of 400 ampre 4 Pole 50 K MCCB in the existing panel board including dismentling of old MCCB with connection testing etc as req etc as requried 1 no | - | - | - | - |
| 1.4 | Repairing and replacement of damaged 1250 ampre bus bar in the existing panel 2.8 meter | - | - | - | - |
| 2 | Repairing of VCB control panel indoor type by way of replacing of charging motor,NONC coils and DC supply 12 volt 100 AH maintance free (MAKE SCHNEIDER) | 1 | Job | - | - |
| 3 | Supply and fixing of CT/PT trivector meter panel Ratio 30/5 / PT 110 Volt including dismentling of existing panel complete job | 1 | No | - | - |
| 4Supply and laying of PVC Power cable (HT) 3.3 KV Grade armoured aluminium XLPE cables including earth work, cost of end termination, thimbles and saddles etc. as required. | |||||
| 4.1 | 120 sq mm x 3 core | 20 | meter | - | - |
| 5 | Construction of platform with concreete base 1:3:6 of (10'- 0"X 4'- 0') 3'- 0" including excavation shuttering and refilling complete job | 1 | Job | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
Termsandconditions.pdf
Tender Documents • 0.22 MB
BOQ_1002187.xls
BOQ • 4.38 MB
Download all tender documents and submit your bid