GE AF UDHAMPUR
GE AF UDHAMPUR
REPAIR AND MAINTENANCE OF SOLAR WATER HEATER FIRE ALARM SYSTEM SMOKE DETECTOR BLAST PEN FLAME PROOF POINT WIRING FITTING FIXTURE ETC AND CONNECTED WORKS AT AF STATION UDHAMPUR
2022_MES_545404_1
GE/AFU-30/2022-23
Open Tender
Civil Works
Item Rate
270 days
UDHAMPUR
as per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE AF UDHAMPUR
₹80,000
Yes
17 Sept 2022
15 Aug 2022
12 Sept 2022
15 Aug 2022
10 Sept 2022
29 Aug 2022
15 Aug 2022 - 20 Aug 2022
Amount
Solar water heater Descaling of solar Collectors plate connected to solar water heater of various capicty(by circulating desclaing solution/agent for 20-30 miniute),cleaning entire surface (dismaintiling of plates shal be carried out if requied including fixing fixing soldering requied)and cleaning of tank of capicity 100/200/300/400 LPD by solar descaling (such as mild acidic solution vinegaretc) solution/agent including drain ouy all Scales dust, dirt by pressure pip[e Cleaning& replacement of U/S drain plug along with all requied work such as welding,theriding etc all as specified and as directd
S&Fin repairs Evacutated tube collector type 100 ltrs solar water heater(MNRE approved) along with GI storage tank of suitable capicity on iron angle stand applying watre sealent around stand fastners including dismaintaling of old unserviceable solar water heater complete as specified and directed.
S&Fin repairs Evacutated tube collector type 200 ltrs solar water heater(MNRE approved) along with GI storage tank of suitable capicity on iron angle stand applying watre sealent around stand fastners including dismaintaling of old unserviceable solar water heater complete as specified and directed.
S&Fin repairs Evacutated tube collector type 300 ltrs solar water heater(MNRE approved) along with GI storage tank of suitable capicity on iron angle stand applying watre sealent around stand fastners including dismaintaling of old unserviceable solar water heater complete as specified and directed.
Supply and replacement Solar water system flat plate collactor with heat exchanger (MNREapproved) type suitable plate size for existing plate complete including taking down complete all as specified and as directed.
Supply and fixing of in replacement of old unserviceable water tank of flate plate solar water heater/Evacuated tube solar water heater capicity 100/200/300/400 LPD along with all connecting items like nut,bolte gasket,soldering welding complete all as specified and as directed.ed.
Labour and material for fixing only serviceable FPC solar plates retrived from 2,3,4 including all nuts washers suitable flexible rubber/silicone hose pipe welding etc including dismainteling of existing non functional FPC solar plate as directed by Engr in charge.
Labour and material for fixing only serviceable Solar heater tank retrived from 2,3,4 including all nuts washers suitable flexible rubber/silicone hose pipe welding etc including dismainteling of existing non functional FPC solar plate as directed by Engr in charge.
.M&L for clading of insulated rubber(rockwool/mineral wool/fibre glass wool)as per fixed on site including one layer of aluminium sheet/flakes cover on outer/air vent of solar water heater GI pipe in a minimise any type of heat losses complete all as specified and as directed by engineer in charge.
Supply and repair unserviceable EPDM sheet including requied nut bolt and washer set at both end used for jointing two flate collector/at end of solar flat plate collector(Medium pressure flexible silicon/rubber hose suitable for hot water of suitable size along with tighting clips wherever requied instead of EPDM sheet) for arresting the leakage complete all as spcifeid and as directed.
Supply and fixing of heating Heating Element 3000Watt alongwiith thermostat of sitable shape and size fitted in solar water tank any capicity conforming to ISI mark with ruber washers with clamps all as specified and as directd by Engr in chare
Suppply and fixing in replacement of U/S Stem type thermostat with switch/nob suitable for solar water heater all as specified and as directed
M&L for cross arms brasings supports clamps and back plates fabricatd from structural steel sections including nuts,bolts washers welding bending cold or hot drilling holes for bolts in any type shape or size as indicated or directed and provn of two coat systhic enamed part over a coat of red oxide primer complete primer all as specifed and as directd.
S& Replacement of Bib taps 15 mm cast copper alloy with crutch or butterfly handle screwed down screwed down screwed for iron pipe or brass ferrule and fancey type including taking down complete all as specified and as directed.
S& Replacement of Bib taps 20 mm cast copper alloy with crutch or butterfly handle screwed down screwed down screwed for iron pipe or brass ferrule and fancey type including taking down complete all as specified and as directed.
S&FGun metal globe or gate valves 20 mm cast iron wheel head screwed both ends for iron pipe and fixed type including taking down complete all as specified and as directed.
S&F Gun metal globe or gate valves 25mm cast iron wheel head screwed both ends for iron pipe and fixed type including taking down complete all as specified and as directed.
Servicing of Fire Alarm control panel complying with BS EN 54 single loop panel /double loop of capacity from 99 detectors & modules upto 200 detector with UV/IR Detection capacity including the following technical specifications and all specified and directed by AGE E/M Note :- (i) All new spare parts shall be measured and paid for separately as supply (a) Primary power supply : 220v +/- 10% AC, 50Hz (b) Standby power supply : 24 V DC (2 Nos of 12V, 7 SMF batteries ) (c) Battery charging voltage ; 27.5 +/- 1V (d) Battery caharging current : 500 mA (max) (e) Pragrammable relay contact : 3 Sets. (f) Relay Contact Rating : 2 Amps 30 V DC (g) Operating temp :- 100C to +550C (h) Humidity : 0 to 95% RH (i) Internal wiring complete two core (j) 1000 event history log (k) Built in battery Charger (l) Two level password protection (m) Contamination level alart for maintenance (n) Detection sensitivity adjustments (from panel) (o) Alarm verification feature (p) upto 127 devices per loop
Supply and replacement of Smoke Detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 including taking down complete all as specifeid and as directed.
Servicing and cleaning of Smoke Detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 as per existing and arrangement of ladder of suitable building height complete all as specifeid and as directed.
S&F Remote response indicators including the following technical specifications and all specified and directed Engr-in-Charge.(a) Operating voltage : between 15-30 volts DC peak (b) Active average current : Less than 20 mA(c) Operating tem :- 100c to +550c(d) Humidity : 0 to 95% RH(e) Wiring : 2 core (f) Capable of high response (g) Real time response
Supply, laying & testing PVC insulated, PVC sheathed FRLS electric control cables (Heavy duty) with stranded copper fire serval cable conductor of size 1.5 sq mm ,2 core, 1100 Volts grade including taking down complete all specified and directed Engr-in-Charge. (Make: KEI/ Finolex/ RR cables/ Polycab/Havells)
Supply, laying & testing PVC insulated, PVC sheathed FRLS electric control cables (Heavy duty) with stranded fire serval cable copper conductor of size 1.5 sq mm ,6 core, 1100 Volts grade complete including taking down all specified and directed Engr-in-Charge.(Make: KEI/ Finolex/ RR cables/ Polycab/Havells)
S&F Addressable manual call point resttable type including the following technical specifications and all specified and directed Engr-in-Charge. (a) Oprating voltage : Between 15-30 volts DC peak (b) Max Stand by current : less than 1mA (c) Alarm LED current : max 1 mA (d) Operating Temp :- 100 C to +550 C (e) humidity : 0 to 95% RH (f) Wiring : 2 core (g) Protective transparent flip cover to prevent accidental activation (h) Electonic Addressing (j) Blinking LED for visual supervision (k) No frangible glass (l) Stable Communication with noise immunity (m) Automatic device Mapping. (n) Alarm flag for fast alarm reporting.
Supply and repair of Battery sealed accied as per existing size suitable for control panel 24 V DC (2 Nos of 12V, 7 SMF batteries )complete all as specified and as directed.
Suply and fixing of Battery Conventional fire panel as per existing size complete all as specified and as direcetd0
Maintanence and repair Fire Alarm Sounders/ Sirens electronic type horizontal single stage continous normal operation for at least 50minuts with sound level 65 DB to 120DB measured at 1.5 metre with sound output variation of + 5DB for 1000 meter Range including the including MCB replacement of unservisble spare parts and all specified and directed Engr-in-Charge.
Maintanence and repair Remote response indicators including including replacement of unservisble spare parts and all specified and directed Engr-in-Charge.
Supply and repair of panel mother board of fire alarm panel including including replacement of unservisble spare parts and all specified and directed Engr-in-Charge.
Integral LED aviation light luminaire in yellow die-cast aluminium alloy housing with red coloured polycarbonate dome of cat part No BGAV 302 LED of make Bajaj or equivalent C&S/CG/Philips including necessary electric connection with suitable size of PVC copper cable as per manufacture's requirement, complete all as specified and as directed by Engineer-in-Charge.
Explosion proof point wiring for for one light/bell/buzzer with 1.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 1.5 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, all as specified.
Explosion proof point wiring for for one light/bell/buzzer with 2.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 2.5 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, including taking down complete all as specified.
Explosion proof point wiring for for one light/bell/buzzer with 4.0 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 4.0 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, including taking down complete all as specified.
Explosion proof point wiring for one 3 pin 16 Amps socket outlet independent with 2.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangments including one number continuous run of 2.5 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, including taking down complete all as specified.
Explosion proof rotary switch single pole on and off with cable termination box of 10 Amps rating 230 Volts Class E EX II C suitable for class I Zone I, all as specified. Make :- Sudhir/Shyam
Supply and repair of Explosion proof rotary switch single pole on and off with cable termination box of 16 Amps rating 250 Volts Class E EX II C suitable for class I Zone I, all as specified. Make :- Sudhir/Shyam
Supply and repair of Flameproof intergral wellglass luminaire epoxy finish LM6 aluminium alloy housing with heat resistant and toughened glass cover painted MS wire guard and eye bolt LED 150 Watt incuding all accessories pre wired with polycarbonate cover polyester resin encloser and central locking system, complete all as specified including taking down old.
Repair and replacement of Flameproof non-intergral wellglass luminaire epoxy finish LM6 aluminium alloy housing with heat resistant and toughened glass cover painted MS wire guard and eye bolt 250 Watt incuding all accessories pre wired with polycarbonate cover polyester resin encloser and central locking system, complete all as specified including taking down old.
Supply and Replacement LED light fitting 2x20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and fixing LED light fitting 1x20 Watt flame proof, CMRI certified commended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and Replacement LED light fitting 40 Watt 4 Feet flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Flame proof LED tube light fitting 2x40 watt 4 Feet Fitting LM-6 Construction with tube rod certified by CMRI including taking down Complete all as specifeid and directed
Supply and replacement of Flame proof Flood light fitting 50 watt LED With IP65 degri of protation with reflector wire guard 50 watt LED ,complete all as specified and direcetd.
Flameproof control gear box epoxy finish LM6 aluminium alloy housing including all accessories prewired with polycarbonate cover polyster resin encloser and central locking system, all as specified including taking down old. Make :- CAT No SSPL/MCGB/180 of shyam or equivalent in Sudhir
Taking down old DB and supply and fixing Flame proof with explosion protection MCB distribution board encloser single pole & neutral 240 volts 12way complete with appropriate size bus bar and neutral link suitable for class 1 Zone 1 & Ex IIC suitable for & including following accessories : (i) MCB SPN 32 Amps with rupturing capacity 16 KA - 01 Nos (ii) MCB SP 06 Amps with rupturing capacity 10KA - 04 Nos Make :- Sudhir or equivalent in shyam
Taking down old DB and supply and fixing Flame proof with explosion protection MCB distribution board encloser single pole & neutral 240 volts 12way complete with appropriate size bus bar and neutral link suitable for class 1 Zone 1 & Ex IIC suitable for & including following accessories : (i) MCB TPN 63 Amps with rupturing capacity 16 KA - 02 Nos (Incoming ) (ii) MCB SP 32 Amps with rupturing capacity 10KA - 02 Nos (ii) MCB SP 6 Amps with rupturing capacity 10KA - 01 Nos (iv) MCB SP 16 Amps with rupturing capacity 10KA - 01 Nos Make :- Sudhir or equivalent in shyam
Flame proof MCB Socket & plug combined 250V 32 AMPS 4P+Earth complete all as specifeid and as directed
Flame proof MCB Socket & plug combined 250V 63 AMPS 4P+Earth complete all as specifeid and as directed
Flame proof FH/199 FLP/WP flexible Metalic Conduit in SS304-3000MM Length with3/4" ET(M)X3/4" ET complete all as specifeied and asd directed.
Flame proof JB/104 FLP Junction box(to be used as incpection Elbow) complete all as specified and as directed.
Flame proof CG/209- FLP/WP3/4" ET 17.50mm OD DC bras Nickel plated Cable Gland complete all as specified and as directed.
Flame proof ACC/2019 FLP/WP Bends for conduit with3/4" ET entries complete all as specified and as directed.
Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16 Amps, 250 Volts, 2P+earth all as specified. Make :- CAT No SSPL/2C/1010 of shyam or equivalent in Sudhir
Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25 Amps, 250 Volts, 2P+earth all as specified. Make :- CAT No SSPL/2C/1010 of shyam or equivalent in Sudhir
Taking down unserviceable hanger lights from the hight of approx 10 to 15 mts from ground lavel including electric connections and supply and fixing hangers lights 150 W GAZELLA HIGHBAY Energy saving environment friendly& robust/Highbay LED Luminanire with high high efficancy(100lm/W) with toughened glass industrial applications,including necessary electric connection,complete all as specified and directed by Engr-in-charge. CAT No GAZELLAHBP150WLED857PBOTG of Havells or equavalent to wipro /Philips/Crompton
Arranging moveable platform for working height for working height 10.50 to 11.00m (with tyred wheels) for the works at Ser No 31 the minimum size of the working platform should be 1.50 mx1.5 m. Complete all as specified and as directed.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of heavey duty PVC conduit drawn through PVC conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 4.00 sqmm main cable and one RM of 4.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
All as per Sl item No 57 but of size 10.00 sqmm but heavey duty 20/25mm conduit PVC pipe (nominal area) and of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire complete all as specified and as directed. . Note: Two runs each of 10.00 sqmm main cable and one RM of 10.00 sqmm cable as earth wire together shall be considered as 1 running metre for payment purpose.
Sheet metal enclosures for DBs SPN 2 way (when MCBs to be used) flush mounted including taking down existing unserviceable DBs /board /box including accessories therein and disposing off complete all as specified and directed. Make:Legrand/HAVELLS / Schneider
MCB SPN 40 to 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed.
MCB SPN 6-32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed.
Cutting of all copper coils & taking out burnt/damaged wire from Sweep flame proof Ceiling fan/E/fan motor of any make and capicity M&L for rewinding of ceiling/Wall mountig fans motor of any make with super enameled copper winding wire of appropriate size/same gauge as original including packing insulating material, soldering, varnishing, assembling and testing including taking down and refixing of any type fan complete all as specified.
S&F in repairs Recess mounting type LED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2' x 2' (Appx) system wattage 34 watt to 36 watt (cool white), minimum system lumen efficacy not less than 80 % , CRI not less than 80, colour temperature not less than 6000 K, power factor not less than 0.95, surge protection device min 2 KV, LED driver with constant output voltage and current at input voltage of 140volt to 285 volt AC, 50 HZ, THD less than 10%, life 50,000 burning hours minimum IP protection IP 20, powder coated housing with ashthetic bottom frame, with excellent heat dissipation through high thermal conductivity, high efficiency transulence diffuser, suitable for any type of ceiling system including connection with PVC insulated copper conductor 3 core cable of 0.50 sqmm complete including taking down all as specified. (Make Havells/Bajaj/CG or Equivalent.)
Cutting of all copper coils & taking out burnt/damaged wire from flame proof ceiling fan motor of any make and M&L for rewinding of ceiling fans motor of any make with super enameled copper winding wire of appropriate size/same gauge as original including packing insulating material, soldering, varnishing, assembling and testing complete all as specified of the following sweep:-
S&F in replacement exhaust fan frame cover made out of M.S sheet of any make and size as per existing exhaust fan with suitable size of nuts, bolts & washers complete all as specified and directed by Engineer-in-Charge.
Cutting of all copper coils & taking out burnt/damaged wire from fan motor of any make and M&L for rewinding of exhaust fans of 450 mm sweep with super enameled copper winding wire of same size, gauge & weight including varnishing & insulating complete all as specified and directed.
Cutting of all copper coils & taking out burnt/damaged wire from exhaust fan motor of any make and M&L for rewinding of exhaust fans of 450 mm sweep with super enameled copper winding wire of same size, gauge & weight including varnishing & insulating complete all as specified and directed.
Description all as per Srl item No. 67 here-in-before but for 300/380mm sweep exhaust fan.
S&F in repairs heating element, cup (round) type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA/Bajaj/Recold/Venus.
S&F in repairs heating element, cup tikona type, 2.00 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA/Bajaj/Recold/Venus.
S&F in repairs heating element, cup tikona type, 1.5.KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA/Bajaj/Recold/Venus.
S&F in repairs 7 " thermostat switch for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. Make : USHA / Bajaj / Recold / Theta / Elcon.
S&F in repairs base 06 Nuts assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
S&F in repairs indicator lamp for geyser of any type colour green & red complete all as specified and as directed. Make : Usha / Bajaj/ Crompton
S&F in repairs plug top 3 pin 15 Amp ISI marked complete all as specified and as directed. Make : SSK/CONA/FINE.
S&F in repairs bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
Description all as per ser item No 77 here-in-before but for 50 ltr geyser
S&F in repairs brass non-return valve 15 mm bore ISI marked screwed both ends and connecting to iron pipe in repairs complete all as specified and as directed. Make : Neta metal works/Orient/Leader/Bir.
Suply and repair of floatvalve 20mm fixing of solar water tank complete all as specified and as directed
Supply and repair of heavey duty flexible pipe 20/25 mmas per site existing size complete all as specified and as directed
.Suply and repair of float valve 15mm fixing of solar water tank complete all as specified and as directed
S&F in repairs brass non-return valve 15 mm bore ISI marked screwed both ends and connecting to iron pipe in repairs complete all as specified and as directed. Make : Neta metal works/Orient/Leader/Bir.
S&F in repairs safety plug confirming to relevant IS with washer suitable for 15 mm GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed. Make : Theta / Usha.
S&F in repairs of pressure relieving valve, confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed. Make : Leader/ Theta or ISI marked.
GI tubing medium grade of size 25mm bore ISI marked galvanized with all fittings such as bends, elbows, tees, check nuts, unions nipples etc for cold water pipe line complete all as specified and as directed including taking down old.
Description all as per item No 85 here-in-before but 20mm bore complete all as specified and as directed. .
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 6 Sqmm 2 core laid on walls/floors or in air with saddles and gutties complete all as specified and directed. Make :- Gloster / Havells / CCI.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 10 Sqmm 2 core laid on walls/floors or in air with saddles and gutties including pvc conduit complete all as specified and directed. Make :- Gloster / Havells / CCI.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 16 Sqmm 2 core laid on walls/floors or in air with saddles and gutties including PVC conduitcomplete all as specified and directed. Make :- Gloster / Havells / CCI.
S&F in recess on wall ERW Conduit of size 20/25mm, ISI marked, heavy duty with all Conduit Accessories and Making Good Surfaces to match the Exiting Treat-ment (as per Site requirement) including Taking down/out Old Unserviceable Conduit, complete all as per specified and as directed.
Flameproof control gear box epoxy finish LM6 aluminium alloy housing including all accessories prewired with polycarbonate cover polyster resin encloser and central locking system, all as specified including taking down old. Make :- CAT No SSPL/MCGB/180 of Sudhir or equivalent in Shyam
M&L Taking down existing Flame Proof Weather Proof Tube Light Fitting 1x36 Watt rod of any type and Make including Taking out Electronic Ballast, Starter, Tube Rod 36/40 Watt and Providing New LED rod 1x40 Watt Complete with Glass of Make Borosil including Making Electric Connection with Connector, complete all as specified and as directed. Make Sudhir
M&L Taking down existing Flame Proof Weather Proof Tube Light Fitting 2x36 Watt rod of any type and Make including Taking out Electronic Ballast, Starter, Tube Rod 36/40 Watt and Providing New LED Light rod 2x20 Watt Complete with Glass of Make Borosil including Making Electric Connection with Connector, complete all as specified and as directed.Make Sudhir
Supply and repair of MS Nipple BSP 175 MM/3/4" as per existing firring /DBs complete all as specified and as directed.
Supply and repair alluminium alloy/ cast iron Neoprene Gasket degree of protetion IP65 and fixing-in -repairs complete all as specified and as directed .
Supply and fixing of 15 Amps switch socket combination complete all as specifed and as directd
Supply and fixing of 20 Watt LED Tube light fitting complete all including taking down as specified and as directed .
Supply and repair of MS Nipple conduit 175 MM/3/4" as per existing firring /DBs complete all as specified and as directed.
MOHAN LAL AND SONS
DAVINDER SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .