Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.5 LAdmitted-Finance | -25.01% | ₹7.5 L | L1 | Admitted-Finance |
| 2 | L2₹9.4 LAdmitted-Finance MEERUT UTTAR PRADESH 250110 INDIA UDYAM UP 56 0008622 | MEERUT | UTTAR PRADESH | 250110 | -5.99% | ₹9.4 L | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Others-Not submitted Work experience as per PQC of bid. |
Updated dates
Tender Value
₹10.0 L
EMD Value
₹12,000
Closing Date
16 Mar 2026, 12:00 pmClosed
Superintending Engineer
Electricity Transmission Circle Agra Kakraitha Road, Near Amar Ujala Press, Sikandara , Agra
Construction of 01 No. 33 KV Airport Bay at 132 KV S/S , Cantt, Agra under ETD-II Agra
2026_UPTCL_1106707_1
ET_86_ETC_A_25_26
Open Tender
Electrical Works
90 days
AGRA
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE_A_ETC_AGRA
₹12,000
27 Apr 2026
16 Jan 2026
17 Mar 2026
16 Jan 2026
16 Mar 2026
16 Jan 2026
Supply of U bolted type Single Tension Fitting Assembly with Gun fitting, suitable for single ACSR Panther Conductor including complete with Hardware fitting, D sackle, Socket Eye, Ball Hook, Yoke Plate, D-Clip,Tension Clamp etc. as per Technical Specification and sample
Supply of U bolted type Single Tension Fitting Assembly with Gun fitting ,suitable for Single ACSR Moose Conductor including complete with Hardware fitting ,D sackle,Socket Eye,Ball Hook,Yoke Plate ,D-Clip,Tension Clamp etc. as per Technical Specification and sample
Supply of PG Clamp duly made of LM-6Aluminium Alloy suitable for ACSR panther to ACSR panther conductor complete with 4 No. 16X90mm GI Bolts ,Nuts,Spring & plain Washer as per technical specification and sample
Supply of PG Clamp duly made of LM-6Aluminium Alloy suitable for ACSR Moose to ACSR Panther conductor complete with 4 No. 16X90mm GI Bolts ,Nuts,Spring &plain Washer as per technical specification and sample
Supply of PG Clamp duly made of LM-6Aluminium Alloy suitable for ACSR Moose to ACSR Moose conductor complete with 4 No. 16X90mm GI Bolts ,Nuts,Spring &plain Washer as per technical specification and sample
Supply of 70Kn porcelin disk insulator
Supply of MS Flat Size 25x6 mm
Supply of MS Flat Size 50x6 mm
Supply of MS Flat Size 75x10 mm
Supply of MS Round 40 mm dia 12 long
3M Long electrode 40mm
Supply of 22 Kg fire extinguisher carbon dioxide type as per IS specification number 2878/1986 and as per technical specification
Supply of 4.5 Kg fire extinguisher dry chemical powder type as per IS specification number 2171/1985 and as per technical specification
Supply of 50 Kg portable AFF mechnical foam type fire extinguisher complete with initial charge hose pipe and all other accessories and fitting as per IS1024 Trolly /wheel mounted
Supply of outdoor 3 phase Metering Cubicle box of size 450x450x250mm duly painted with one coat of red oxie primer and two coat of synthetic enamel paint and hole should be provided for 8 no. cables of 50/95 sq mm with cable glands(fire proof) of dowell make then termination on both side cables .cubical box made of 16 SWG MS sheet sheet in double shutter with indoor locking arrangements complete with wiring of proper size and phase indicator and earthing terminal. Fixing of Cubical will also done by supplier at is own cost.
Supply of 2 tonn split air conditioning unit with stabalizer(Rating not less then 5 KVA) in the control room make Ogeneral / Mitishubushi complete with all associated accessories having 2 year comprehensive and 5 year compressor warrenty due to not availibilty of air conditining in new extended control room. Fixing of Air Conditioner will also done by supplier at is own cost.
Supply of outdoor high beam flood light with power 150 Watt (LED) as light Sourse and versitile pressure Die-cast aluminium body with poly carbonate fitting having potted type power driver suitable for 220 AC input supply of IS marked havels/philips/Syska with warrenty of 2 year. Fixing of LED Lights will also done by supplier at is own cost.
Earthmat extention and strenghtening work
Laying of earthmat in the exitended switchyard of the substation alomg with connecting the newly laid earthmat with existing earthmat as per details below:-
Fabrication of 3 mtr long electrode with 40mm dia Ms Round bar having 150mm long conical shape by due cutting straighting etc. and then piercing it vertically inside the ground with top 700mm below the ground level including shifting of MS round bar from the storage place at substation to switcyard
Laying of 40mm Dia MS round bar, 700mm below the ground level by due cutting straighting welding,painting excavation of trenches,backfilling of trench after laying of earthmat include shifting of MS round bar from storage place to switchyard
Making of 150mm long lap joint of above laid 40mm dia round bar to conect with existing earth mat of substation by due cutting straighting welding etc.
Making of cross joint of above laid 40mm dia MS round bar 700mm below the ground level by due welding at all four corners including provifing and welding od suitable size 4 No of MS angle pieces on opposite corner of cross joint
Making of MS joint of above laid 40mm dia MS round bar with top of already vertically peirced MS electrode 700mm below ground level by due welding
Erection work
33 KV Bay and bus bar erection work
Erection/Fabrication/Dismantling (if needed) of Lattice type main gantry and auxillary structure their respective beams as per drawing /BOM is to be carraied out by contractor .All the duly stacked members of structure are to be shifted from store to work site ,tightining of nut ,bolts washer,fastening of beams applying standard practise .Beams are to be fastened on the proper alignment with exting coloum including latest cost of all labour ,T&P etc
Laying and stringing of 33 KV 3 phase bus bar including hoisting of disc insulator, suspension and tension fitting etc. along with shifting of the conductor/material place at that substation to the erection site
Stringing of 33 KV 3 phase Jack bus/Main bus bar of single ACSR panther/moose conductor(1 JOB for each phase of bus bar per section)
Erection of equipment in proper alignment with complete adjustment in switchyard on the erected structure as per manufacture drawing or as per direction of supervising engineer after levelling including shifting the equipment from store to working site etc, alonf with their junction box, control cubical and accessories including the latest cost of labour T&P cranes for proper completion of work
33KV Tripple feeder control panel
33 KV VCB with structure and modification if necessary
33 KV CT with junction box
33 KV PT with junction box
33 KV Line isolator with PI ,earth switch and adjustment
33 KV Bus isolator with PI ,earth switch and adjustment
33 KV Post insulator on ALP structure
Installation of new 3P 4W 0.2S Class Energy Meter
Opening of trench cover ,Laying and dressing of following size control cable on the cable racks in the trenches from crontrol and relay panel to various equipments for AC/DC connection of CT,PT,CB, isolator,junction box incude shifing of cables drums from store to erection site &shifting back the balanced material to store again placing back the opened trench cover including latest cost of labour,,T&P,etc. to complete the works
2C*2.5 sq mm
4C *2.5 sq mm
6C*2.5 sq mm
Termination of various sizes above laid control cable as per schedule and connection diagram ,extending DC supply from DCDB and AC supply from ACDB ,Contro & relay panel,Equipment,CT,PT, including Drilling of holes wherever required ,fixing of performated cable tray ,fixing different sizes of cable gland ,ferrul,&crimping type ,lugs,including latest cost of required skilled material ,Technician,T&P for proper completion of work.
Earthing of main and auxillary structure equipment,trench and panels with the help of specified size MS flat along with cutting ,bendind and straigtining of MS flat to give it proper shape Two coat if Enamel based paint of green colour above red oxide primer layer at joint ,riser strips in all sides of surface as per drawing of earthing and standard practise incuding latest cost of consumable material,T&P ,lobour Etc.
Earthing with 75*10mm MS Flat
Earthing with 50*6mm MS Flat
Earthing with 25*6mm MS Flat
Jumpering of equipment of 33 KV bay with the help of ACSR Moose or panther conductor to connect main bus bar and tranfer bus bar with equipment and eqipment to equipment with help of suitable clamp /connector including ,cutting ,bending,shaping,etc,of the conductor as per site requirment
Providing ,fixing and installation of Sign board of 3ft*2ftduly made of 2mm thick GI plate painted with red oxide promer with 2 coatinf and then yellow bright and shiny yellow paint and panted with black letter as direction of site engineer.board shall be provided with back support frame of size 35mm*35mm*5mm with provision of 2 leg for grouting duly painyed with black enamel paint complete with all repect to be grouted with casting of C.C founadation
Work of loading, safe carriage and unlaoding of any equipment, structure or any other material from any substation of UPPTCL to JE store of 132KV S/S Cantt,Agra. Every Equipment for carriage to 132KV S/S,Cantt ,Agra will be considered as one job.
Supply and fixing of junction box of size 280X22X150mm made of 16 SWG sheet duly painted on cloumn by fixing GI flat and its earthing with 12 SWG GI wire and fixing 1 no of 6 amp MCB for connection to the LED with 3 phase backalite terminal block and cooper neutral link complete in all respect with all material,labour and T&P
laying and termination of 2C/4C/6C 2.5 sq mm size of cable 500mm below the ground including excavation of trench of appropriate size ,laying cable termination proper dressing and all assocated work to complete the job as per specification.
Supply and fixing of outdoor 3 phase Lightining AC Subdistribution box of size 450x450x250mm duly painted with one coat of red oxie primer and two coat of synthetic enamel paint .4 No almunium insulated bus bar for AC distributional and 1 no. of 100AMP TPN SFU with SS of haevells /L&T make/C&S.It should have 4 no. of bakalite fuse with fuse base of 100 Amp and hole should be provided for 4 no. cables of 50/95 sq mm with cable glands(fire proof) of dowell make then termination on both side cables .cubical box made of 16 SWG MS sheet sheet in double shutter with indoor locking arrangements complete with wiring of proper size and phase indicatora nd earthing terminal
Re-erction after dismentalling of Street lighting pole with complete accessories which include main pole body ,lightining fixture ,cable and termination box.The work include erection of street ligting pole after digging pit and casting M25 RCC mix founadation of pole and then laying the cable below the ground in he deph of 300mm and proper temiantion the cable at pole and nearby power supply .after that hosting the tlighting box and stree light such that proper alignment and tighting is ensure.Each pole dismentalling and re erection will be considered as one job.
supply and Laying of A, grade hot dip GI Pipe of following size inside the trench and laying of Control cable of 4x2.5 sq. mm, 2x2.5 sq. mm inside the pipe. Work includes cutting of thread, fixing of Elbow/Band, T-joint, four bay cross joint and other associated material required to complete the pilpher proofing work including all labour and T&P required as per site condition to complete the job satisfactrorily as per direction of Supervising engineer.
GI Pipe 2 inches
GI Pipe 1 inches
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tech.pdf
Tender Documents • 1.02 MB
BOQ_2041940.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid