Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | ₹42.2 L Quoted ₹42.7 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹45.0 L+₹2.3 L (5.41%)Rejected-Finance | ₹45.0 L+₹2.3 L (5.41%) | L2 | Rejected-Finance Higher bidder |
| 3 | L3₹46.1 L+₹3.5 L (8.15%)Rejected-Finance C2 PAIXOMONTIRO APTS BEHIND NSD ALTO DABOLIM VASCO DA GAMA GOA 403 801 | SOUTH GOA | GOA | 403801 | ₹46.1 L+₹3.5 L (8.15%) | L3 | Rejected-Finance Higher bidder |
| 4 | L4₹46.7 L+₹4.0 L (9.44%)Rejected-Finance | ₹46.7 L+₹4.0 L (9.44%) | L4 | Rejected-Finance Higher bidder |
| 5 | L5₹47.5 L+₹4.8 L (11.3%)Rejected-Finance FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | ₹47.5 L+₹4.8 L (11.3%) | L5 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
8 Jun 2021, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO BUILDING NO P15 P16 AND KA28 STORE HOUSE BUILDING NO P28 AT MO GOA UNDER GE GOMANTAK VASCO
2021_MES_438481_1
85377/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE GOMANTAK VASCO
₹84,000
Yes
29 Jun 2021
26 Apr 2021
10 Jun 2021
26 Apr 2021
8 Jun 2021
1 Jun 2021
Amount
Schedule 'A' Part I - B/R portion
Demolition of cement concrete (Un reinforced) in ground floors n.exc 15cm thick above or below ground level all as specified and as directed.
M & L for 75 mm thick PCC 1 : 4 : 8 type D2 using 40mm graded stone aggregate cement concrete as in Sub base all as specified and as directed.
M&L for Plain Cement concrete Type B-2,1:2:4 using 20mm graded stone aggregate, 100mm thick as in of floorings, finished even and smooth and laid in bays of 1500 x 1500mm all as specified and as directed.
M&L for providing cement concrete type C-1, 1:3:6 using 20mm graded stone aggregate, 50 mm thick , 75cm wide as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight) all as specified and as directed.
M&L for glass dividing strips,3mm thick and width of strip in 38mm flooring of slab work etc all as specified and as directed.
Removing loose concrete/plaster upto sound stratum of ceiling chajjas, columns and beams and cleaned the surface with water using water jet etc complete all as specified and as directed.
M&L for apply one coat of chemicals as approved to old rusted reinforcement after necessary preparation of surfaces by brush application as per mistric 100 all as specified and as directed.
M&L for priming the old/new steel reinforcement bars with one coat of primer (Protective coating) as approved by brush application all as specified and as directed.
M & L for previously prepared steel/concrete surfaces surface and apply concrete penetrating corrision inhibitor complete all as specified. After few minutes wipe the concrete/steel surface with moist cloth to remove residual materials from the surface and follow up the application all as specified and as directed.
M&L for providing and applying approved bonding agent prior to application of any type of mortar plaster to ensure bond between old concrete and new concrete all as specified and as directed.
M&L for apply one layer of SL concrete 20mm thick compress composition 1:2:1 plain cement concrete ie one part of cement, two part of course aggregate & One part of 10mm & down size trap stone aggregate mixed with spray set SL 2 TO 2.5% by weight on concrete surfaces all as specified and as directed.
M&L for cutting out cracks to 'V'section not exceeding 5mm in existing roofs walls by using machine cleaning the groove to remove all loose laitance & washing with water applying crack fillet with the aid of a putty blade compete all as specified and as directed.
S&F Welded steel wire fabric (not exc 4 kg) complete to wood or steel members all as specified and as directed.
M&L for CRS TMT bars of 8 mm dia and above cut to length bent to shape as required all as specified and as directed.
Supply , assembly and erection of GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of size 26 Gauge all as specified and as directed.
Removing building materials etc.to a distance of 1.00 Km beyond the lead included in the rates, including loading, unloading and stacking at the destination all as specified and as directed. Note : 6 cum shall be considered as one load.
Taking down chowkhat or frames of door/ window / ventilators with shutter without taking off shutter from the frame n.exc 1.50 sqm each all as specified and as directed.
Taking down chowkhat or frames of door/ window with shutters without taking off shutter from the frame exc 1.50 sqm and n.exc 4.00 Sqm each all as specified and as directed.
S&F aluminium powder coated frame and shutters for windows/ventilators sliding/fixed/openable type complete with necessary fittings such as two concealed lock for each window, roller etc and fixing all as specified and as directed. Notes : (a) Weight of aluminium three track section and tubes for windows/ventilators shall not be less than 0.55 Kg/RM and not more than 1.00 Kg/RM. (b) The weight of rubber gasket beading shall not be measured with the weight of aluminium shutters. Glass shall be measuerd and paid separately. (c) The rate quoted by the contractor shall also include necessary wheels for sliding shutters and hinges for side hung/top hung shutter as required at sight and concealed locks for windows. (d) The colour of powder coating shall be as approved by GE.
S & F Mild steel 4 levers Mortice lock type, size 100mm all as specified and as directed.
S&F aluminium anodised barrel tower bolt 200 mm, extruded section all as specified and as directed.
S& F aluminium anodised sliding door bolts with hasp and staple extruded section or cast aluminium alloy 300 mm long all as specified and as directed.
S&F 100 mm butt hinges, medium weight cold rolled mild steel all as specified and as directed.
S&F aluminium handle cast type anodised 150 mm long all as specified and as directed.
S&F glazing with 4 mm thick sheet glass ordinary type including rubber beadings/gasket around glass panes all as specified and as directed.
Hacking out old broken glass (any thicknes, size, quality or description) from wooden frames or stone, concrete or brick surroundings, glazed with putty or fixed with beads all as specified and as directed.
S&F aluminium anodised wire mesh of size 1.5 mm x 3 mm mesh 20 Gauge thick all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as a gap insert for top rail and bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S frame welded / sealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side as per specification and drawings.
S&F Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing.
Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed..
All as per item No 31 here in before, but plain steel sheet all as specified and as directed.
Dismantling of false ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets all as specified and as directed.
S&F 605x605mm anodised aluminium snap grid frame work for false ceiling using standard anodised aluminium T section of size 45mm x 25mm x 1.5mm thick and 45 x 25 x 1.5mm thick angle section, including necessary 'J' bolts fixed with hangers 6mm dia, G.I. (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out G.I. flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long complete all as specified and as directed.
S&F Gypsum board of 12 mm thick for false ceiling 60cm x 60cm with staples on snap grid all as specified and as directed.
Taking down cement plaster from brick or stone walls including racking out joints hacking for key, scrubbing down with water etc. all as specified and as directed.
M&L for rendering 15mm thick cement plaster with cement mortar 1:4 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement with using water proofing compound. Note : WPC shall be measured and paid separately.
M&L for rendering 15mm thick cement plaster with cement mortar 1:6 on other than fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement all as specified and as directed.
M&L for rendering 5mm thick cement plaster with cement mortar 1:3 on concrete surface as in ceiling finished even and smooth without using extra cement all as specified and as directed.
Supply only Integral waterproofing compound.
M&L for applying two coats of Anti fungal paint over a coat of primer to match the existing colour including preparation of newly plastered surface all as specified and as directed.
M&L for applying one coat of Anti fungal paint over a coat of primer to match the existing colour including preparation of old plastered surface all as specified and as directed.
M&L for preparation of new treated surfaces and apply three coats of white wash to walls all as specified and as directed.
M&L for preparation of old treated surfaces and apply one coat of white wash to walls all as specified and as directed.
M&L for preparation of new treated surfaces and apply three coats of white wash to ceiling all as specified and as directed.
All as per item No.45 here in before, but two coats of white wash on old ceiling surface all as specified and as directed.
M&L for applying two coats of anti-fungal paint over a coat of primer on old plastered surface including complete removal of existing treatment all as specified and as directed.
M&L for two coats of oil bound distemper including preparation of old plastered surfaces complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
M&L for one coat of synthetic enamel paint to old steel surface over 10 cm width or girth including preparation of surfaces all as specified and as directed.
Supply & fixing for 1.25mm thickness of laths Steel Rolling shutters, without ball bearing gear operated type with bevel gear box and crank handle as specified including top cover, anchoring rod,hasp and one shop coat of primer, erected in position as indicated,complete all as specified and as directed.
S&F Glazing with figured glass(Frosted), pin head type, 3mm thick, and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane all as specified and as directed.
Dismantling water tanks exc 500 but n exc 1000 ltr. capacity all as specified and as directed.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 500 Ltrs ISI Marked
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 1000 Ltrs ISI Marked.
Supply and fixing Ball Valve for CPVC pipe of 25 mm outer diameter all as specified and as directed.
S & F 15mm Bib taps, fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and as directed.
Supply and fixing 20 mm dia. stop valve fancy type brass C.P all as specified and as directed.
S&F in repair bib tap cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe 15 mm dia all as specified and as directed.
S&F in repair stop valves cast copper alloy CP screwed down high pressure with crutch or butterfly handle 20mm dia bore all as specified and as directed.
S&F in repair ball valve high pressure PTMT with epoxy coated aluminium rod & high density plastic ball for 20mm dia bore all as specified and as directed.
S&F in repair vitrous china wash hand basin white flat back, size 550x400mm including waste pipe , chromium plated waste coupling 32mm dia , bracket etc complete all as specified and as directed.
S&F in repair pillar tap, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe for 15 mm bore dia of pipe all as specified and as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store in 20 mm dia all as specified and as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store in 15 mm dia all as specified and as directed.
Supplying and laying of 20 mm dia. CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of 15 mm dia Mild steel galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed.
All as per the description of item No.67 here in before, but re-fixing old steel tubing complete all as specified and as directed.
Supplying and laying of 20 mm dia Mild steel galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed.
All as per the description of item No.69 here in before, but re-fixing old steel tubing complete all as specified and as directed.
M&L for repairs to existing railing, MS Grill of spiral stair cases and shafts including welding to existing fixing with fasterner anchoring in adjacent wall/column/slab etc complete all as specified and as directed.
M & L for hardcore with broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and as directed.
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specified and as directed.
M & L for precast cement concrete block masonry with solid block exc 10 cm in width and setting in cement mortar 1:6, grade C-5 using 20mm graded stone aggregate all as specified and as directed.
Dismantling/taking down existing hessian base felt or clay tiles or any other water proofing treatment from roof/chajja including cement plaster, cleaning the surface and removing the dismantled debris to a distance exceeding 1.50 Km but not exceeding 5 Km to outside the MD land all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar 1:3 as in roof slab, Chajja drops, roof on brick or concrete surfaces including roughning surfaces of old concrete by picking, sweeping clean and washing down with water to remove dust etc all as specified and as directed.
M&L for water proofing treatment using 4mm thick APP modified membrane consisting five layer membranes with features as specified weighing not less than 3.5 kg/sqm reinforced with oven polyester fiber @ 160gm/sqm laid over a coat of cold applied bituminous primer @ 0.40kg/sqm by torching the membrane and sealing the overlap by 100mm length side 150mm width side all as per manufacturer instructions including joints and changes in direction be curved with cement mortar 1:3 mixed with SBR latex@ 200ml bag of cement curved well before laying membrane all as per manufacturer instructions and to the satisfaction of Engineer-in -Charge. Notes : (i) Irrespective of lap the net covered area shall only be measured for payment. (ii) Rate is inclusive of APP membrane ,SBRlatex.ii and M&L for bituminous aluminium paint @ 200gm/sqm (min) in two coats .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises all as specified and as directed.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 sqm, in floors etc,set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:4 all as specified and as directed.
M&L for glazed ceramic tile 300 x 200 x 06-7mm thick (coloured) on vertical surfaces such as dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick backing coat in cement and sand mortar 1:4 all as specified and as directed.
M & L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cement mortar 1:4 all as specified and as directed.
S&F plain, aluminium sheeting, alloy 31000H4 (0.56mm thickness) in ridges,hips, valley gutter, drip and straight flashing (length and girth asfixed) etc all as specified and as directed.
Supply and fixing 75 mm dia PVC (SWR) pipe single socketed in any length with rubber ring joints and laid in trenches or in wall all as specified and as directed.
Dismantling wrought iron or mild steel work of any description all as specified and as directed.
Schedule 'A' Part II - INTERNAL ELECTRIFICATION
Taking down carefully aluminium point wiring (light, fan, socket, bell or power) complete including all fittings and fixtures, removing, materials from site and making good disturbed surfaces of wall, ceilings etc. all as specified and as directed.
M & L for point wiring complete with 1100 V grade PVC insulated and unsheathed multistranded 1.5 sqmm single FRLSH core copper conductor cable drawn through and including PVC concealed conduit of size not less than 20 mm with all accessories including 1.5 sqmm PVC insulated and unsheathed FRLSH copper conductor cable as earth continuity wire all as specified for one light, fan, 5 Amps socket outlet in same board, etc and making good disturbed surface of walls and floors to match with existing surfaces all as specified and as directed.
All as per item No 86 here in before, but for 2/3 pin socket out let 5 Amps with 1.5 Sqmm on independent board all as specified and as directed.
All as per item No 86 here-in-before, but for 2 in 1 three pin socket outlet 15/20 Amps on independent board with 4 Sqmm cable FRLSH copper conductor multistranded including 4 sqmm PVC insulated and unsheathed FRLSH copper conductor cable as earth continuity wire all as specified and as directed.
Supply & Fixing modular switch 1 way 6A, 1 module, 230 volts all as specified and as directed.
Supply & Fixing modular switch one way 16 Amps, 1 module, 230 volts all as specified and as directed.
Supply & Fixing modular socket 6 Amps-2/3 pin combined, 2 module all as specified and as directed.
Supply & Fixing modular socket 6A/16A-2/3 pin combined, 2 module all as specified and as directed.
Supply & fixing modular metal flush box 3 module all as specified and as directed.
Supply & fixing modular metal flush box 8 module all as specified and as directed.
Supply & fixing modular metal flush box 12 module all as specified and as directed.
Supply & fixing modular white cover plate with frame, 3 module all as specified and as directed.
Supply & fixing modular white cover plate with frame, 8 module all as specified and as directed.
Supply & fixing modular white cover plate with frame, 12 module all as specified and as directed.
Supply and fix ceiling rose surfaces bakelite 65 x 50 mm three terminals including supply and fix PVC plate or square blocks all as specified and as directed.
Supply & Fixing stepped type 2 module modular electronic fan regulator flush type including removal of old one all as specified and as directed.
Supply & fixing MCB, 6 to 32 Amps, single pole, C Series, 10 KA, 240 volts all as specified and as directed.
Supply & fixing MCB, 6 to 32 Amps, single pole neutral, C Series, 10 KA, 240 volts all as specified and as directed.
Supply and fixing MCB 32 Amps TPN, C Series, 10 KA, 415 volts all as specified and as directed.
Supply and fixing MCB 40 Amps TPN, C Series, 10 KA, 415 volts all as specified and as directed.
Supply & Fixing sheet metal enclosure DB, 8 way, SPN, double door factory made powder coated including neutral and earth link connector flush fixed in wall complete including dismantling of old one complete all as specified and as directed.
Supply & Fixing sheet metal enclosure DB, 4 way, TPN, double door factory made powder coated including neutral and earth link connector flush fixed in wall complete including dismantling of old one all as specified and as directed.
Supply & Fixing sheet metal enclosure for insulated plug and socket of 03 Phase, 01 Neutral and 1 earth, 32 Amps, 415V flush fixed in wall complete all as specified and as directed.
Supply & Fixing submain wiring with 2 Runs of 2.5 Sqmm, PVC insulated, unsheathed, single core, multistranded, 1100 volts, FRLSH copper conductor cable drawn in and including 25/32mm wide PVC conduit concealed with all accessories as required along with 1 run of 2.5 sqmm PVC insulated, unsheathed, single core, multi stranded copper conductor cable as continuous earth wire and connecting to existing main switch board/Distribution Board and testing on completion all as specified and as directed. Note :- 02 run of 2.5 sqmm and 01 run of 2.5 sqm including 01 run of PVC conduit shall be measured as one length.
Supply & Fixing submain wiring with 2 Runs of 4 Sqmm, PVC insulated, unsheathed, single core, multi stranded, 1100 volts, FRLSH copper conductor cable drawn in and including 25/32mm wide PVC conduit concealed with all accessories as required along with 1 run of 4 sqmm PVC insulated, unsheathed, single core, multi stranded copper conductor cable as continuous earth wire and connecting to existing main switch board/Distribution Board and testing on completion all as specified and as directed. Note :- 02 run of 4.0 sqmm and 01 run of 4.0 sqm including 01 run of PVC conduit shall be measured as one length.
Supply & Fixing submain wiring with 4 Runs of 6 Sqmm, PVC insulated, unsheathed, single core, multi stranded, 1100 volts, FRLSH copper conductor cable drawn in and including PVC conduit concealed with all accessories as required along with 1 run of 6 sqmm PVC insulated, unsheathed, single core, multi stranded copper conductor cable as continuous earth wire and connecting to existing main switch board/Distribution Board and testing on completion all as specified and as directed. Note :- 04 run of 6.0 sqmm and 01 run of 6.0 sqm including 01 run of PVC conduit shall be measured as one length.
Supply & fixing brushless direct current (BLDC) ceiling fan 1200mm sweep (ISI Marked), 230 volts, 26 Watt including connection rod as per existing size of length of GI pipe medium grade including dismantling of old one and depositing in MES store yard all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI wire 4mm dia by means of bolts, nuts, check nuts & washers of GI or steel, and earth lead connected to main DB panel/meter box panel including necessary earth work and excavation of in any type of strata, chamber in PCC 1:2:4 type B-2 with CI cover, GI tubing 15mm dia light grade for protection of GI wire, GI tubing 20mm dia for watering etc all as per electrical plate no 3 of SSR part-I including provision of earthing test point & connecting to electrical equipment and testing on completion all as specified and as directed. Note : GI earth wire upto 7.5 RM is included in the unit rate quoted.
Supply & Fixing GI pipe with suitable clamps on existing pole made of MS flat 40x5mm and 40mm dia GI pipe (light grade) bend to 1.2 mtr in length & in any shape with all fixing arrangement, nuts, bolts and washers etc and including 2.5m copper conductor cable multistranded of 2.5 Sqmm PVC cable from overhead line to fitting connecting box etc complete all as specified and as directed and including dismantling the rusted/ broken U/S old one.
Supply & Fixing LED street light fitting of 45 Watts Powder coated pressure die cast aluminium High Power LED as light source with heat resistant toughened glass with lens having IP66 protection, taking down the old one complete all as specified and as directed.
Schedule 'A' Part II- EXTERNAL ELECTRIFICATION
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in hard/dense soil for UG cable any size all as specified and as directed.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 in depth getting out soft / disintegrated rock for UG cable of any size all as specified and as directed.
M & L for sand cushion in trenches for cable protection complete all as directed and specified.
Supply and lay PCC cable cover class LV type I flat size 250mm x150mmx40mm with ISI mark all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed all as specified and as directed.
Supply & fixing UG LT cable XLPE insulated armoured heavy duty 1100 volts grade with aluminium conductor multistandarded of size 35 sqmm 3.5 core including centre gland, lugs, jointing materials etc laid in trenches or fixed it to wall and taking down old unserviceable cable all as specified and as directed.
Supply and laying GI Pipe light grade of 50 mm dia laid in trenches or fixed in walls complete all as specified and as directed.
JINTECH
M/S P S BABU
K M SUBHANAIAH
M/S jvsr constructions
CVs CONSTRUCTIONS
Super Construction
sapna enterprises
SHREE THATWAMASSY CONSTRUCTIONS PRIVATE LIMITED
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .