Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAdmitted-Finance JHARIA BENIGANJ HARDOI | BENIGANJ | HARDOI | UTTAR PRADESH | ₹2.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.6 Cr+₹22.3 L (9.58%)Admitted-Finance | ₹2.6 Cr+₹22.3 L (9.58%) | L2 | Admitted-Finance |
| 3 | L3₹2.9 Cr+₹56.0 L (24.0%)Admitted-Finance | ₹2.9 Cr+₹56.0 L (24.0%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | INDIA SUPPY CORPORATION L3 | M/s Anil kumar singh L1 | M/S SHUKLA ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00Part A (Materials Provided by contractor) | ||||||
| 1.01 | ST Pole 9 m long | 44 | No | 12,500 ₹5,50,000 | 9,660 ₹4,25,040 Lowest | 12,000 ₹5,28,000 |
| 1.02 | ST Pole 11 m long | 8 | No | 15,500 ₹1,24,000 | 12,180 ₹97,440 Lowest | 15,500 ₹1,24,000 |
| 1.03 | ACSR weasel Conductor | 600 | Mtr | 20 ₹12,000 Lowest | 20 ₹12,000 Lowest | 40 ₹24,000 |
| 1.04 | ACSR Dog Conductor | 200 | Mtr | 78 ₹15,600 | 70 ₹14,000 Lowest | 85 ₹17,000 |
| 1.05 | 3x300 mm² ‘XLPE’ cable 33 KV | 9,315 | Mtr | 1,950 ₹1,81,64,250 | 1,800 ₹1,67,67,000 Lowest | 1,800 ₹1,67,67,000 Lowest |
| 1.06 | 3x120 mm² ‘XLPE’ cable 11 KV | 4,008 | Mtr | 800 ₹32,06,400 | 730 ₹29,25,840 | 715 ₹28,65,720 Lowest |
| 1.07 | 3x120+1x95+1x16 mm² LT AB Cable | 100 | Mtr | 400 ₹40,000 | 243 ₹24,300 Lowest | 350 ₹35,000 |
| 1.08 | 33 KV ‘XLPE’ C/J Kit 3x300mm² Outdoor | 54 | No. | 9,000 ₹4,86,000 | 3,780 ₹2,04,120 Lowest | 4,700 ₹2,53,800 |
| 1.09 | 33 KV ‘XLPE’ C/J Kit 3x300mm² St. Through | 5 | No. | 20,000 ₹1,00,000 | 13,020 ₹65,100 | 13,000 ₹65,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
12 Feb 2024, 4:00 pmClosed
Superintending Engineer
Srirampuram Colony Mohaddipur Gorakhpur.
Line Shifting work Naya savera Deoria bypass road Gorakhpur
2024_PVVNV_890847_1
36/EWC(G)/2023-24
Open Tender
Electrical Works
Item Rate
15 days
Gorakhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
SE EWC
₹5 L
Yes
14 Feb 2024
5 Feb 2024
13 Feb 2024
5 Feb 2024
12 Feb 2024
5 Feb 2024
Amount
Part A (Materials Provided by contractor)
ST Pole 9 m long
ST Pole 11 m long
ACSR weasel Conductor
ACSR Dog Conductor
3x300 mm² ‘XLPE’ cable 33 KV
3x120 mm² ‘XLPE’ cable 11 KV
3x120+1x95+1x16 mm² LT AB Cable
33 KV ‘XLPE’ C/J Kit 3x300mm² Outdoor
33 KV ‘XLPE’ C/J Kit 3x300mm² St. Through
11 KV ‘XLPE’ C/J Kit 3x120mm² Outdoor
11 KV ‘XLPE’ C/J Kit 3x120mm² St. Through
Number Plate
Danger Board with Clamp
Barbed wire
Bolts, Nuts, & Washers
MS Earthing Rod 20x2500 mm
GI wire 5 mm
Al. Paint
Red oxide Paint
11 KV Polymer Pin Insulator
11 KV Top channel
11 KV Cross Bracing Angle
11 KV Top channel/Bracing angle clamp with nut bolt for ST Pole with nut bolt by 50x6 mm MS flat Iron make
Extra angle for cable support (suitable as 11 KV)
Clamp for extra angle support (suitable as 11 KV)
11 KV Polymer Disc Insulator
11 KV Polymer Disc fitting
Wire for jumper
11 KV Stay Rod 16x1800 mm
11 KV Stay clamp for ST Pole with Nut and Bolt by 50x6 mm MS Flat Iron make.
Stay wire 7/10 SWG
33 KV. Top channel (125x65mmX3200 mm (10.7 Kg/m)
33 KV Top channel clamp with nut bolt for ST Pole with nut bolt by 50x8 mm MS flat Iron make
33 KV Stay Clamp for ST Pole with Nut and Bolt by 50x8 mm MS Flat Iron make.
Stay Rod 20x1800 mm
Stay wire 7/8 SWG
P.G. Clamp for DOG as per requirement
33 KV M.S. Angle Iron 65x65x6mm bracing
33 KV M.S. bracing Angle clamp with nut bolt for ST Pole with nut bolt by 50x8 mm MS flat Iron make
Extra angle for cable support (suitable as 33 KV)
Clamp for extra angle support (suitable as 33 KV)
33 KV Stay Rod 20x1800 mm
33 KV Stay clamp for ST Pole with Nut and Bolt by 50x8 mm MS Flat Iron make.
Stay wire 7/8 SWG
33 KV Polymer Disc Insulator B& S type
33 KV Polymer Disc fitting for Dog conductor
33KV Al. binding wire
ST pole stud clamp with nut bolt for ST Pole with nut bolt by 50x8 mm MS flat Iron make
11 KV LT T-Off clamp
11 KV MS channel T-off 125x65x1300mm
LT cable 4x16 sqmm
Distribution box
Clamp for Distribution box
Clamp for T/F
Eye bolt for service cable
LT cable 1x16 sqmm
Al. Lug for Temporary line
Al. Lug for Permanent line
Stay complete with grouting for Temporary line (Stay clamp, wire And Stay rod)
PART - B- WORK
Erection of Double pole structure on 9 mtr ST Pole for 11 KV cable rising only including all works of evocation of pit, pole erection, making plinth for poles 30 cm above, grouting in the ratio 1:4:8 (cement, sand, 40 mm brick ballast), back filling of earth, proper ramming & fitting of all accessories for (M.S. angle iron 65 x 65 x 6 mm bracing with clamps, top channel 125 x 65 x 2028 mm with clamps, danger board with clamp, Aluminium paint, red oxide paint, barbed wire earthing, etc. complete) .
Erection of Double pole structure on 9 mtr ST Pole for 33 KV cable rising only including all works of evocation of pit, pole erection, making plinth for poles 30 cm above, grouting in the ratio 1:4:8 (cement, sand, 40 mm brick ballast), back filling of earth, proper ramming & fitting of all accessories for (M.S. angle iron 65 x 65 x 6 mm bracing with clamps, top channel 125 x 65 x 3200 mm with clamps, danger board with clamp, Aluminium paint, red oxide paint, barbed wire earthing, etc. complete) .
Erection of Double pole structure on 11 mtr ST Pole for 33 KV one side overhead and one side cable rising including all works of evocation of pit, pole erection, making plinth for poles 30 cm above, grouting in the ratio 1:4:8 (cement, sand, 40 mm brick ballast), back filling of earth, proper ramming & fitting of all accessories for (M.S. angle iron bracing with clamps, top channel 125 x 65 x 3200 mm with clamps, danger board with clamp, Aluminium paint, red oxide paint, barbed wire earthing, etc. complete) .
Erection of Single pole as stud pole structure on 11mtr ST. (SP-55) Pole including all works of evocation of pit, pole erection, making plinth for poles 30 cm above, grouting in the ratio 1:4:8 (cement, sand, 40mm brick ballast), back filling of earth, proper ramming & fitting of all accessories (clamps with bolt and nut, danger board with clamp, Aluminium paint, red oxide paint, barbed wire earthing, etc. complete).
Erection of Double pole structure on 11 mtr ST Pole for Transformer installation including all works of evocation of pit, pole erection, making plinth for poles 30 cm above, grouting in the ratio 1:4:8 (cement, sand, 40 mm brick ballast), back filling of earth, proper ramming & fitting of all accessories for (M.S. angle iron bracing with clamps, top channel 125 x 65 x 3200 mm with clamps, danger board with clamp, Aluminium paint, red oxide paint, barbed wire earthing, etc. complete).
Laying, spreading, lifting and final sagging of 1 wire of ACSR weasel Conductor in accordance parallel with AB Cable as a neutral wire. fixing of Clamp as per requirement.
Laying, spreading and jumpring of ACSR Dog conductor and Cable rising.
Open Cable Duct slab & laying of 33 KV 3x300 mm² ‘XLPE’ cable(D/C) in Cable trench (Cable trench already constructed by Jal Nigam with hanger) with proper Laying on cable hanger and filling sand if require.
Laying of 33 KV 3x300 mm² ‘XLPE’ cable(D/C) by digging pit & making trench in Proper size (1.2M depth x1M wide) below ground level by fixing bricks(4½˝) on both side of trench wall and 9˝ brick work at the centre of the trench along the cable. Fixing brick slab on top after filling sand around both the cable including cost of bricks and sand/HDD Method as per site require.
Laying of 11 KV 3x120 mm² ‘XLPE’ cable(D/C) by digging pit & making trench in Proper size (1.2M depth x1M wide) below ground level by fixing bricks(4½˝) on both side of trench wall and 9˝ brick work at the centre of the trench along the cable. Fixing brick slab on top after filling sand around both the cable including cost of bricks and sand/HDD Method as per site require.
Road restoration charges during 33 KV cable laying under the road crossing
Road restoration charges during 11 KV cable laying under the road crossing
Open Cable Duct slab & laying of 11 KV 3x120 mm² ‘XLPE’ cable(D/C) in Cable trench (Cable trench already constructed by Jal Nigam with hanger) with proper Laying on cable hanger and filling sand if require.
Rising of 33 KV ‘XLPE’ cable in air after providing 6” dia. M.S pipe 3 m long Complete work.
Rising of 11 KV ‘XLPE’ cable in air after providing 6” dia. M.S pipe 3 m long Complete work.
Providing GI Pipe Earthing Complete for Cable jointing Kit with materials
Shifting, loading, Carriage and re-installation of Existing 10/16 kVA T/F From Existing place to Shifted Place.
Installation of distribution Box
Labour charges for Hanging of LT AB Cable on new erected pole with LT AB Cable clamp complete.
Cable jointing charges of 33 KV XLPE Cable Outdoor/ Straight Through
Cable jointing charges of 11 KV XLPE Cable Outdoor/Straight through.
Temporary line work
Erection of 9 M long ST pole for cable rising and fitting of cross arm and clamp with nut & bolt.
Lifting, spreading and cable hanging on new erected ST pole as temporary line
Grouting of stay complete
Dismentling of old and used temporary Line materials with complete fitting and Shifting, Loading Carriage & Unloading from Work site to store centre Gorakhpur at the end of final shifting.
Dismentling charges of existing Single Pole 8.5 mtr. PCC Pole.
Dismentling charges of existing Single Pole 11 mtr. ST Pole.
Dismentling charges of existing Double Pole 11mtr. ST Pole.
Dismentaling charges of old ACSR Dog conductor and rolling in pieces.
Dismentaling charges of old ACSR Weasel conductor and rolling in pieces.
Dismentaling charges of existing Al. cable scrap and rolling in pieces.
Shifting, Loading, Carriage & Unloading of old and damaged 33/11 KV/LT Line materials from work site to Store centre Gorkahpur Distt. Gorakhpur.
M/S SHUKLA ENTERPRISES
INDIA SUPPY CORPORATION
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .