Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.2 LAdmitted-Finance | +12.00% | ₹7.2 L | L1 | Admitted-Finance |
Tender Value
₹7.5 L
EMD Value
₹15,100
Closing Date
11 Jun 2026, 6:00 pmClosed
US MEENA SE TNC BARMER
Office of SE tnc rvpn barmer
Construction of 03 Nos. 132KV bays (01 No. each at 132KV GSS Siwana, 132KV GSS Panoriya and 220KV GSS Sheo) for erection of 132KV equipment, structures, Jumpering and Earthing work, laying, termination and joining of cables on labour contract basis.
2026_RRVPN_563183_1
1410002606
Open Tender
Electrical Works
Percentage
WORK
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
AO TNC BARMER
₹15,100
Yes
16 Jun 2026
28 May 2026
12 Jun 2026
28 May 2026
11 Jun 2026
28 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | EARTH MESH WORK
Laying of earth mesh with 25mm/28mm dia M.S Rod at a depth of 0.80 meter from top level of foundations, including excavation of trench of required depth and backfilling of the same, transportation of M.S Rods from site store to locations, welding of M.S Rod to M.S Rod along the length, at crossings and with earth electrodes as per drawing, application of bitumen compound and covering with bitumen impreganated tape on all welding joints, for the type of soil prevalent at 0.80 mete below top level of foundations (M.S Rod of above size & M.S flat as required shall be made available by RVPN).
(a) In case electricity is made available by RVPN without charges
i) Any soil, soft Rock other than Hard Rock | - | MTR | 35 | - |
| 1.02 | Laying of earthing risers of 50x6mm/50x10mm/50x12mm size M.S Flat at a depth of 0.80 meters from top level of foundations, including excavation of trench of required depth and backfilling of the same, transportation of M.S Flat from site store to locations, preparation of risers bending as per requirement ( after heating if necessary), fixing on and welding / bolting to equiopment/ structure and peaks of structures, laying in the trench, welding to the earth mesh of M.S Rods as per drawing, including welding of extra length of M.S Flat of required, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, painting of all surface of risers above ground level with red oxide and green paint, for the type of soil prevalent at 0.80 meter below top level of foundations ( M.S Rod of above sizes & M.S Flat as required shall be made available by RVPN)
(a) In case electricity is made available by RVPN without charges
i) Any soil, soft Rock other than Hard Rock | - | MTR | 39 | - |
| 1.03 | Placing / Driving of earth electrode of 25 / 28mm dia. M. S. Rod of length 3.30 meters (approx.) to a depth of 3.80 meters from the top level of foundations, including excavation of pit as required and back filling of the same, transportation of M. S. Rod from site store to locations, cutting of M. S. Rod to desired length, preparation of one end as spike if necessary, welding of earth electrode to earth mesh of M. S. Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 3.80 metres below top level of foundations (M. S. Rod of above sizes & M. S. Flat as required shall be made available by RVPN).
(a) In case electricity is made available by RVPN without charges
i) Any soil, soft Rock other than Hard Rock | - | Nos | 374 | - |
| 1.04 | ERECTION OF SUB STATION STEEL STRUCTURES columns, beams lighting mast and equiopemtn structures ( excluding Circuit Breakers and Capacitors Banks ) of all types including transportation of structure members nuts & bolts, washers etc from site store to locations , their assembly, placing on foundation, fxinmg of template, with foundation bolts as required, levelling and preparing for grounding as required but excluding grouting erection after grouting and tightening & punching of nuts & bolts. ( Maximum height of structures upto 20 meters). | - | MT | 3,176 | - |
| 1.05 | BUS - BAR WORK
STRINGING OF 220 KV , 132 KV, 33 KV & 11KV Bus Bar of ACSR conductor, including transportation of counductor, disc insulators and tension hardware from site stores to location, laying and cutting required length of conductor, cleaning and assembly of disc of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available fitting of bolted type or compression type tension hardware as made available ( compression machine shall be provided by RVPN on rent free basis ) making up at one end, stringing of conductors between the beams with specified sag and tension, also equalizing sag and fitting spacers and spacer T-clamps for twin conductor for three phases of conductors in each bus section (Per Jumper Basis)
i) Any Single Conductor | - | SEC. | 1,594 | - |
| 1.06 | BUS - BAR WORK
STRINGING OF 220 KV , 132 KV, 33 KV & 11KV Bus Bar of ACSR conductor, including transportation of counductor, disc insulators and tension hardware from site stores to location, laying and cutting required length of conductor, cleaning and assembly of disc of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available fitting of bolted type or compression type tension hardware as made available ( compression machine shall be provided by RVPN on rent free basis ) making up at one end, stringing of conductors between the beams with specified sag and tension, also equalizing sag and fitting spacers and spacer T-clamps for twin conductor for three phases of conductors in each bus section (Per Jumper Basis)
i) Any Double Conductor | - | SEC. | 2,406 | - |
| 1.07 | JUMPERS OF ACSR conductor (3 nos Y type) between bus to equipment or between equipment to equiopment or between bus to bus, including transportation of conductor, disc insulatros and hardware from site stiores to locations, cleaning and assembly of disc insulators as required along with fitting of suspension hardware and erection as required, cutting required length of conductor, making connections,fixing of spacers & spacer T clamps as required tightening of clamps / connectors, dressing etc for three phases (Per Jumper Basis)
i) Any Conductor | - | SET | 152 | - |
| 1.08 | STRINGING OF Earth wire (size 7/3.15mm or 7/4.00mm), including transportation of eathwire, tension hardwares, etc from site store to locations lasying and cutting required length of earthwire, fitting of bolted type or compression type hardware as made available ( comppression machine shall be provided by RVPN on rent free basis), making up at one end stringing of earthware between structure peaks with specified sag and tension, jumpering and connecting earth bonds for single earthwire. | - | EACH | 400 | - |
| 1.09 | ERECTION OF SUB-STATION EQUIPMENTS
Erection of C.T / P.T /CVT/ Series Reactor / RVT / NCT with clamps & connectors on already erected steel structure including transportation from site stores to locations, fabrication of base frme, fixing of terminal connectors, tightening of nuts & bolts etc complete in all respect.
ii) 132KV CT / PT/CVT | - | NOS | 1,936 | - |
| 1.1 | Erection of Lightening Arrestor on already erected steel structure including transportation of Lightening Arrestor, clamps & connectors, Surge counter, etc. from site store to locations, fabrication of base frame, fixing of terminal connectors, surge counter, tightening of nuts and bolts etc. complete in all respect.
ii) 132 KV | - | NOS | 1,946 | - |
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
biddoc.pdf
Tender Documents • 0.63 MB
BOQ_1002357.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .