Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.9 LAccepted-AOC 107 1F TOLLYGUNGE ROAD KOLKATA 700026 WB | KOLKATA | WEST BENGAL | 700026 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹42.8 L+₹2.2 L (5.32%)Rejected-Finance 107 1A TOLLYGAUNG ROAD KOLKATA 700026 WB | KOLKATA | WEST BENGAL | 700026 | L2 | Rejected-Finance Being higher bid value | |
| 3 | Rejected-Technical NOT FOUND | - | Rejected-Technical Insufficient documents |
Tender Value
₹38.2 L
EMD Value
₹76,400
Closing Date
3 Mar 2023, 6:00 pmClosed
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
SPL REPAIR TO BLDG NO P-124 (MT GARAGE), ROOF TREATMENT OF BLDG NO P-10 (ADM BLOCK) OF TRANSFUSION CENTRE (EC), ADDN/ ALTN OF ROOM NO A-119 IN ADM BLOCK AND SPL REPAIR TO NURSING OFFRS MESS (P-94), PROVN OF RO PLANT ROOM IN NEPHROLOGY AT CH (EC)
2023_MES_578935_1
GE/ALP (8157B) OF KOLKATA 2022-23
Open Tender
Civil Works
Item Rate
120 days
GE ALIPORE KOLKATA
Class D and category a (i)
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹76,400
Yes
GE ALIPORE
20 Mar 2023
3 Feb 2023
4 Mar 2023
3 Feb 2023
3 Mar 2023
17 Feb 2023
3 Feb 2023 - 10 Feb 2023
11 Feb 2023
Amount
Taking down cement plaster on brick or stone walls(concrete or masonry surfaces), etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete in all respect as specified.
Chipping of unsound /weak concrete materials from slabs , beams,columns ,lintel,chajja, fin , facia etc. by any means as directed by engr-in-charge including tapering all edges, making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting incl foreign matrials , loose concrete/aggregate etc and disposal of all debris out of MOD land and complete in all respect as specified for 60 mm average thickness Coloumn
Add or deduct for every 10 mm thickness extra complete all as specified. (against item No 2 here in before)
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm clear air gap)by manual methods (using wire brushing ,chiselling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area throughly by water and allow it to dry all as per manufacturer,s instruction to give it a totally rust free finished steel surface complete in all respect as specified (Make : SIKA/FOSROC/Hindcon) upto 12 mm dia bar
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm clear air gap)by manual methods (using wire brushing ,chiselling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area throughly by water and allow it to dry all as per manufacturer,s instruction to give it a totally rust free finished steel surface complete in all respect as specified (Make : SIKA/FOSROC/Hindcon) above 12 mm dia bar
M & L for providing single coat of epoxy bond adhesive of prepared non metallic surface (existing surface) and applying by brush all as per manufactures instruction/specification. The bonding agent shall have minimum compressive strength of 40 N/Sqmm and complete all as specified & directed.
Supply and application of Epoxy Zinc rich primer on the prepared steel surface by brush the primer shall have a minimium specific gravity 1.75 minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 complete in all respect as specified. (Make : SIKA/FOSROC)
M & L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc . The micro concrete shall have a minimium 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minium tensile strength 5N/mm2 @ 28 days, minimium flextural strength 5N/mm2 @ 28days and complete in all respect as specified (Make : SIKA/FOSROC/Hindcon) 60 mm average thickness of Column (upto 4 storey High).
Add or deduct for every 10 mm thickness extra (against item No 8 here in before)
Use and waste of formwork to sides of column, pillars, posts, stanchions for rough foinished surface complete in all respect as specified by the Engr-in-Charge
Demolition of cement concrete of any description and in any position not other wise specifiy provided for complete in all respect as specified.
M&L Cement concrete (1:3:6) using 40 mm graded stone aggregate as in Cement concrete in foundations, filling and mass concrete complete all as specified and as directed by the Engr-in-Charge.
Demolition of Brickwork quoins,arches,pillars etc but excluding ashlar cings,dressed all store work and precast concrete articles built in cement mortar complete all as specified and as directed by the Engr-in-Charge.
M&L for brick work with sub class 'B' bricks built in cement mortar (1:6) straight or curved on plan exceeding 6 mtr mean radius and all as directed (upto 04 storey High of building)
M&L for Rendering 15 mm thick in CM (1:6) on other than fair face of brick work or concrete surfaces and finished the surface even and smooth without using extra cement to match the existing surface all complete in all respect as specified
M&L for Rendering 15mm thick in two layers (Top 10mm thick rendering coat mixed with water proofing compound shall be laid over 10mm thcik plastered surface) with CM (1:4) on of brick work or concrete surfaces finished the surface even and smooth without using extra cement to match the existing surface complete in all respect as specified Note: WPC shall be measured and paid separately under relevant items.
Supply only Integral water proofing compound
M&L for preparation of wall surfaces and applying two coats of cement base paint (white or coloured as per site requirement) over a coat of alkali resistant primimg paint on new wall surfaces complete all as specified and directed.
M & L for one coat of Cement base paint in (white or coloured as per site reqmt) old surfaces with complete removal of existing treatment complete in all respect as specified.
M&L Preparing new plastered surfaces of wall and applying 3 coats of white wash on walls complete in all respect as specified
M&L preparation of old surface and applying one coat of white wash on ceiling to match with the new one all complete in all respect as specified.
Material & labour preparation of old steel and iron surfaces of any description area exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide and zinc chrome primer, complete in all respect as specified
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete in all respect as specified
M&L Rolled Mild Steel Fe- 290 (Gde E- 165)Framed work (in Mumty Door) as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete complete in all respect as specified.
S & F Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) 0.71 mm thickness complete in all respect as specified.
S&F Cast iron or malleable cast iron handles, cast type, stove enamelled black 150 mm length complete in all respect as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete in all respect as specified.
S & F rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., quality conforming to Gde Fe 410-S complete all as specified and as directed
S & F Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. quality conforming to Gde Fe 410-S complete all as specified and as directed
Preparing new or previously untreated steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over & including a coat of red oxide primer complete.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings
S & F Pre painted galvalume aluminium Zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding fixed with self taping screws as specified.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M&L for PCC (1:2:4) type B-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed
All as per item No 35 above Add or deduct for each 25 mm girth or part thereof over or under 30cm -ditto-
Dismantling floor hearth or wall tiling including cement motor bedding incl backing, removing serviceable tiles to stone and rubbish off the premises complete all as specified and directed.
Demolation of cement concrete (reinforced) in ground floor,chajjas,fins and paving not exceeding 15 cm thick (below or above G.L) all as specified and directed
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walling built in cement mortar (1:4) complete all as specified and directed.
Taking out/Stripping of old Roof treatment membranes/Tar felt incl layer of cement mortar of any type carefully from roof surfaces (without damaging roof) and including preparation of old roof surfaces by picking, sweeping, cleaning and washing down with water to remove dust & receive new treatment complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type 'B-0' using 12.5 mm graded crushed stone aggregate finished with even and smooth without using extra cement for padding concrete with minimum thickness of 25 mm with a slope of (1:40) complete all as specified and directed.
M&L for 10 mm thick rendering in cement mortar 1:4 mixed with Water Proofing Compound as per manufacture's instructions and top surface of rendering finished even and smooth to recieve water proofing treatment complete all as specified and directed. Note : Water Proofing Compound shall be measured and paid separately.
M&L for applying evenly a tack coat of industrial bitumon 85/25 at the rate of 1.2 kg per sqm including cleaning surface on roof surface for fixing APP membrane complete all as specified and directed.
M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid over bitumen coasted surface of roof applied with proper torch flames all as per manufactures instruction. NOTE:- The APP membrane will have an overlaping of 100 mm on the end laps and 150 mm on side laps. The overlaping and joints will be thermo sealed with the propare torch complete all as specified and directed.
M&L for applying protective coating with aluminium paint @ 0.2 kg/sqm complete all as specified and directed.
M&L cutting out cracks to "V" section in existing roofs of terracing cleaning out, wetting, grouting, with cement sand slurry (1:3) complete all as specified and directed.
M&L for cement concrete tiles size 20cmx20cmx25mm thick set, jointed and pointed in neat cement slurry in roof with grey cement and no pigment with 20 mm thick screed bed complete all as directed
Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. beams, columns etc. 50 mm average thickness including tapering all edges, making square shoulders of cavities air and cleaning of exposed concrete surface of lightly picking materials by manual method including foreign materials , loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and as directed upto 8 storey bldg.(INCL necessary scaffolding)
Removing of concrete all around reinforcement bar upto 16 mm dia and over from behind the reinforcing bars average 25mm (but not less than 15mm air gap)by manual methods (using wire brushing ,chiselling etc) and applying chloride free rust removing chemical on rusting steel reinforcement bar and removing all rust from steel reinforcement bar by emery paper and cleaning the area throughly by water and allow it to dry and totally rust free of reinforcement bar all as complete as per manufacturer's instruction as specified and as directed. upto 8 storey bldg. Make (Rust removing chemical) :- Reebaklens RR of FOSROC or quivalents solutions SIKA/STP as approved by GE.
Material, labour and prepared existing reinforcement surface by brush and application two component epoxy zincrich primer on existing reinforcement surface of minimum specific gravity 1.75, adhesive bond strength with steel is 1.50N/mm2 and maximum coverage area 5.00 Sqm per litre complete all as specified and directed.upto 4 storey bldg.(INCL necessary scaffolding) Make- Nitozinc primer of FOSROC or equivalents chemical given in approved make list of PS.
Material and labour for introducing new reinforcement bars upto 12 mm dia and over for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling,fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed.upto 4 storey bldg.(INCL necessary scaffolding)
Material , labour and placing in position free flow shrinkage cementitious micro concrete of compressive strength, flexural strength shall not be less than 50 MPa at 28 days , 5MPa at 28 days respectively for strengthening of beams, columns & other structural elements of average thickness 25 to 50 mm and including surface preparation & suitable type formwork etc. as per manufacturers instruction and 15 mm thick plaster complete all as specified and as directed. upto 4 storey bldg.Make (micro concrete):-Renderoc RG of FOSROC or equivalents solutions SIKA/STP as approved by GE.
Taking up or down 40 mm or 50 mm bore steel water tubing /CPVC pipe and connections of following bore complete all as specified and as directed
S&F galvanised 40 mm bore steel water tubing (GI pipe), medium grade with all fittings and fixed to wall, floor and ceiling of following bore complete all as specified and as directed
S&F in repair 20 mm bore (Outer dia) CPVC pipes (concelead)of SDR 11and plain CPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete all as directed by Engr-in-Charge .
S&F in repair 25 mm bore (Outer dia) CPVC pipes of SDR 11and plain CPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete all as directed by Engr-in-Charge .
S&F in repair 50 mm bore (Outer dia) UPVC pipes of (SCH-40)and plain UPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete all as directed by Engr-in-Charge .
M&L for applying Finishing walls in new surfaces with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete in all respect all as specified and directed by the Engr-in-Charge.
S & F in repair 100mm bore spun cast iron pipes on soil waste pipes, in any length with or without ears, with cement joints, fixed to walls complete in all respect as specified and directed.
S & F in repair 100 mm bore spun cast iron soil waste pipes bend fixed with cement joints, fixed to walls complete in all respect as specified and directed.
S & F in repair 100 mm spun iron branch pieces, single (equal or unequal), ordinary or inverted(spigot or socket type) or with parallel branches, complete all as specified and directed.
Dismantling of plain or corrugated aesbestos sheet any gauge, thickness in roof coverings complete all as specified and directed.
Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Dismantling of timber scantlings 40 sq. cm and over in section, in any position framed in roof complete all as specified and directed.
M&L for PCC (1:2:4) type B2 using 20mm graded stone aggregate as in foundation base, pedestal etc complete all as specified
M&L for preparing surfaces new decorated plastered or unplastered surfaces of wall, pillasters, cornices etc and applying two coats of acrylic distemper etc complete all as specified and as directed.
M&L for preparing new plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm etc complete all as specified.
M&L for applying 3mm thick wall care putty on newly plastered surfaces to make smooth and even to receive wall finishes etc complete all as specified.
M&L for preparing old decorated plastered or unplastered surfaces of wall, pillasters, cornices etc and applying one coat of acrylic distemper with wall care putty complete all as specified and as directed.
M&L for 100mm thick cement concrete type C2, (1:3:6) (40mm graded stone aggregate) in sub base in floors complete all as specified.
M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl 15mm thick screed bed in CM (1:6) complete all as specified.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed in CM 1:4 complete all as specified.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified.
S&F Steel work in tubular trusses, posts,rafters, struss etc including special shaped washers etc. complete using ERW or induction butt welded tubes incl preparation surfaces and applying one shop coat of Zinc chromate primer paint etc.
Supply & Fixing for Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/chadding to wall, fixed with self tapping screws as specified.
Supply & Fixing for Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/chadding to wall, ficed with self tapping screws as specified as in ridges.
M&L for two coats of synthetic enamel paint over a coat of red oxide on new steel surfaces of any description, not otherwise described over 10cm width or grith after preparation complete.
M&L for plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping, etc., including necessary form work all as specified and directed.
S&F for Powder coated aluminium sliding windows for three track with rubber gasket, stopper powder coated aluminium standard beads/glazing clips ,locking arrangement etc and aluminium frame of size 80mmX25mmX1.55mm and shutter of section 20mm X20mm X1.55mm (two shutter of 4.8mm thick glass and one shutter of wiremesh 0.36 mm dia of wire and average width of aperture 1.40 mm) including aluminium grill of aperature hole 50x50 mm 6 mm thick with necessary all fittings complete all as per manufacturer's instructions and all as specified and as directed by the Engr-in-Charge.
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete(Fe-290(Gde E-165).
M&L for coloured, glazed ceramic tiles size 450mmx300mmx 6-7mm thick, in dado/skirting etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, laid with and including over10 mm thick rendering in CM (1:3) all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed.
Removing excavated material (soil) n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for providing cement concrete (1:4:8) type D2 (Using 40mm graded stone aggregate) in foundation, mass concrete and filiings complete all as specified and directed.
M & L, providing RCC M-25 (Design mix), using 20 mm graded stone aggregate as in footing and plinth beams and the like complete all as specified and directed.
M & L, RCC M-25 (Design mix), using 20 mm graded stone aggregate, as in columns and the like complete all as specified and directed.
M & L, RCC M-25 (Design mix), using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed.
M & L, RCC M-25 (Design mix), using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed.
M & L, mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L,mild steel TMT bars 6 to 8 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L, use and waste of form work to flat rough finished surfaces of concrete in fdns, footing and plinth beam and simillar work complete all as specified and directed.
M & L, use and waste of form work to square / rectangular / polygon side of columns complete all as specified and directed.
M & L, use and waste of form work to flat rough finished surface of soffits of floor beams. Lintel beam, roof beam , landing, waist slabs, chajja railing and similar work.
M & L, use and waste of form work to flat rough finished surface of soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for Rendering 10mm thick in CM (1:6) on other than fair face of brick work or concrete surfaces and finished the surface even and smooth without using extra cement to match complete all as specified and as directed.
M&L hardcore of gauge n.exc. 63mm deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to surface etc complete all as specified and directed.
M&L providing cement concrete (1:4:8) type D2 (Using 40mm graded stone agg) , 100mm thick as in sub base in floor/paving etc.
M&L providing cement concrete (1:2:4) type B0 (Using 12.5mm graded stone agg) , 40mm thick as in floor/paving finishing used extra cement etc.
M&L silver sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed by the Engr-in-Charge.
M & L for 60 mm thick coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-35 Grade with grey cement and no pigment complete all as specified and as directed.
M & L for brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar (1:4) complete all as specified and directed.
M&L for Rendering 5mm thick with CM (1:3) on or concrete surfaces and finished the surface even and smooth without using extra cement as in ceiling complete all as specified and as directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M&L preparation of new plaster surface and applying three coats of white wash on ceiling complete all as specified and as directed by Engr-in-Charge.
M&L for 15mm thick plastering on other than fair faces of wall surfaces in CM (1:4) surface finished even and fair complete all as specified and directed.
M&L for 15mm thick plastering on fair faces of brick wall and concrete surfaces in CM (1:6) surface finished even and fair complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for light shade double chareged Virified Ceramic tiles 9-10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry over a bedding layer of screed bed 15 mm thick and CM 1:4 and pointed in white or coloured cement to match complete all as specified and directed.
M&L for complete removal of existing treatment of old decorated wall surfaces complete all as specified and directed.
M&L for old decorated walls surfaces to take 2mm thick wall care putty complete all as specified and as directed.
M&L for old decorated walls take a two coat of acrylic oil emulsion distemper complete all as specified and directed by Engr-in-Charge.
M&L for complete removal of existing treatment of old decorated ceiling surfaces complete all as specified and directed by Engr-in-Charge.
M&L for old decorated ceiling surfaces take 2 mm thick wall care putty complete all as specified and directed by Engr-in-Charge.
M&L for old decorated ceiling take a two coat of acrylic oil emulsion distemper complete all as specified and directed by Engr-in-Charge.
M&L for preparing surfaces new decorated plastered or unplastered surfaces of wall, pillasters, cornices etc and applying two coat of acrylic distemper with 3 mm thick wall care putty complete all as specified and directed by Engr-in-Charge.
M&L for preparing new decorated plastered or unplastered surfaces of ceiling , pillasters, cornices etc applying coat of 2.0 mm thick wall care putty with two coat acrylic distemper complete all as specified and directed by Engr-in-Charge.
M&L for preparing of plastered and un plastered surfaces of old decorated walls take a one coat of acrylic oil emulsion distemper complete all as specified and directed by Engr-in-Charge.
M&L for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed
5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing.
Taking down carefully aluminium/copper point wiring (all type) (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendent, regulators, sockets, bell push, bell, light fittings etc. removing serviceable materials to store for keeping in safe custody for reuse at site or for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces.
M & L for point wiring (modular fittings) complete with 1.5 Sqmm single core multi stranded copper conductor PVC (FRLSH) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked in and including PVC rigid conduit (thickness 1.6mm) MMS ISI marked with accessories concealed in wall / roof / ceiling etc and including sunken pressed steel terminal boxes for modular in wall and 1.50 sq mm PVC insulated unsheathed stranded copper conductor for common earth and connecting to earth dolly material and labour for one light/fan/bed point controlled by one way switch.
All as per item No 122 here-in-before but for 3 pin 6 Amps socket outlet on the same board with 1.5 sqmm cable complete all as specified and as directed.
All as per item No 122 here-in-before but for 3 pin 6 Amps switch socket on the independent board with 1.5 sqmm cable complete as specified and directed.
All as per item No 122 here-in-before but for switch socket 2 in 1,3 pin 5/15 Amp on independent board with single core 2.5 Sqmm PVC unsheathed copper cable and single core 2.5 sqmm copper conductor cable as earth continuity conductor complete all as specified and as directed.
Supply and fixing of modular socket outlet 2 in 1, 5 pin 5 Amp,230 Volts complete all as specified and as directed. Make : Indo Asian/Havells/Legrand.
Supply and fixing modular socket 2 in 1,5/15 Amps, 230 Volts, including boxes , cover plate etc universal complete all as specified and as directed by the Engr-in-Charge. Make : Indo Asian/Havells/Legrand.
Supply and fixing of switch modular type 5/6 Amps 230 Volt single pole, one way including boxes , cover plate etc complete all as specified and as directed by the Engr-in-Charge. Make : Indo Asian/Havells/Legrand.
Supply and fixing of switch modular type 16 Amps 230 Volt single pole, one way including boxes , cover plate etc complete all as specified and as directed by the Engr-in-Charge. Make : Indo Asian/Havells/Legrand.
Supply and fixing of modular Fan regulator upto 100 watt ,230 volt complete all as specified and as directed. Make : Indo Asian/Havells/Legrand.
Supply & Fixing of Modular White cover plate with frame, 2 module complete all as specified and as directed. Make : Indo Asian/Havells/Legrand.
Supply & Fixing of Modular White cover plate with frame, 4 module complete all as specified and as directed. Make : Indo Asian/Havells/Legrand.
Supply & Fixing of Modular White cover plate with frame, 8/12 module complete all as specified and as directed. Make : Indo Asian/Havells/Legrand.
Supply & Fixing of Modular Metal flush box 2 module complete all as specified and as directed. Make : Indo Asian/Havells/Legrand.
Supply & Fixing of Modular Metal flush box 4 module complete all as specified and as directed. Make : Indo Asian/Havells/Legrand.
Supply & Fixing of Modular Metal flush box 8/12 module complete all as specified and as directed. Make : Indo Asian/Havells/Legrand.
Supply and fixing ceiling rose surface bakelite three terminal 65 x 50mm, PVC/Polycarbonate,isolated body complete all as specified and as directed by the Engr-in-Charge. Make : Indo Asian/Havells/Anchor/Legrand.
Supply and fixing in repairs main stream battens fitting LED 20 watt with tube 4 feet long fixing on PVC/wooden round block complete with all accessories, prewired and flexible wire twin core from ceiling rose to terminal block complete all as specified and as directed. Make: Havells Cat No LUMILINEBS20WLED865SPCWH/Philips/Crompton as specified.
Supply and Fixing LED Square Light 36 W of size 2 feet x 2 feet, occupation senson type, lP54, lumen output 100lm/w, 50 Hz, color temp 5700-6500K, CRI>80, THD<10%, PF>0.9, operating voltage 120-300V, surge protection >3KV, lumen 1800, dust free & zero maintenance LED clean room bottom opening luminaire with CRCA powder coating housing, anti glare diffuser with potentiometric integrated energy electronic driver, with all accessories prewired and connecting electrically, after dismenteling of existing light, complete all as specified and directed. Make: Havells Cat Part No. VENUSNEOHE2X2R36WLED857PIRSENSOR /Crompton/Bajaj.
Ceiling fan of 1200mm sweep, suitable to work on single phase, AC 230 volts, 50 hz supply complete with and including down rod , PVC insulated and overall sheathed 3 core flexible copper conductor cable of size 23/0.0076 size from ceiling rose to ceiling fan and testing complete all as specified and directed. Make : Bajaj/Havells/Crompton.
Supply and fixing sub-main wiring (concealed) for main DB's to sub DB's with PVC (FR-LSH) insulated & unsheathed two runs of 6 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 6 sq mm PVC FR-LSH insulated & unsheathed copper conductor cable, 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through and including PVC rigid conduit with all accesseries carefully complete all as directed by the Engr-in-Charge. Make :- Anchor/Havells/Polycab. Note : Three runs of 6 sqmm cable and one run PVC Conduit shall constitute one unit.
Supply and fixing sub-main wiring (concealed) for main DB's to sub DB's with PVC (FR-LSH) insulated & unsheathed two runs of 4 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 4 sq mm PVC FR-LSH insulated & unsheathed copper conductor cable, 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through and including PVC rigid conduit with all accesseries carefully complete all as directed by the Engr-in-Charge. Make :- Anchor/Havells/Polycab. Note : Three runs of 4 sqmm cable and one run PVC Conduit shall constitute one unit.
Supply and fixing of MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed by the Engr-in-Charge. Make :- Havells/Legrand/L&T.
Supply and Fixing of MCB, single pole, 240 Volts, of capacity (6-32 Amps) 'C' series breaking capacity 10 KA. complete all as specified and as directed. Make :- Havells/Legrand/L&T.
Supply and fixing of MCB SPN, 40 to 63 Amps, 240 Volts, 'C' series, breaking capacity 10KA complete all as specified and as directed. Make :- Havells/Legrand/L&T.
Material and labour for power supply unit consisting of starter with 20 Amps over load protection, MCB-20 Amps, 2 Pin & Earth plug socket including MS/PVC box & top cover for AC. Make : Legrand/Crabtree/Cona.
All as per item No 122 here-in-before but for switch socket combination 2 in 1,3 pin 5/15 Amp on independent board with 2.5 Sqmm PVC unsheathed copper cable and 2.5 sqmm copper conductor cable as earth continuity conductor complete as directed.
Supply and fixing of flush switch socket combination 3 pin 15 Amps, 230 Volts, including boxes , cover plate etc universal complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing of flush switch socket combination 3 pin 5 Amps Amps, 230 Volts, including boxes , cover plate etc universal complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing of switch flush type 5/6 Amps 230 Volt single pole, one way including boxes , cover plate etc complete all as specified and as directed by the Engr-in-Charge
Supply & fixing bldg security lighting of LED 36 watts high efficennt lighting solution anodised with heat resistance with accessories provided including necessary electric connection with all accessories required for fixing/mounting with nut bolt washer & clamp support on GI pipe1.5 meters of suitable diameter complete all as specified and as directed. Havells Cat No: SL36WLED757PASYBOPCWOSPD or equivalent in other Crompton/HPL/Surya etc
Supply and fixing as in repair MCB DB SPN (double door) 12 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised lead wire of size 4.0 sqmm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 15 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.
Taking down ceiling fan of any type, any make and any sweep for repairing,opening the body and blade, checking for repalcement of unserviceable spares,cleaning, overhauling, greasing, replacement of unserviceable spare by new one, re-assembling of all components in original position, testing and hanging up the same as directed
Taking down exhaust fan/wall mounted of any type, any make, by opening of body carefully checking for repalcement of unserviceable spares, including replacement of spares by new one, re-assembling of all components in original position, cleaning, oiling greasing, testing and fixed in original position complete all as specified and as directed.
M & L in repair for switch socket combination 2 in 1, 5 pin 5 Amps, 240 V Flush type, all as specified. Make: Anchor/Indo Asian/Havells.
Supply and fix in repair switch socket combination 2 in 1,5/15 Amps, 230 Volts, flush type universal complete all as specified and as directed by the Engr-in-Charge. Make: Anchor/Indo Asian/Havells.
Supply and fixingin repair switch piano, flush type 5 Amps 230 Volt single pole, one way complete all as specified and as directed by the Engr-in-Charge. Make :- Anchor/Philips/Legrand.
Supply and fixing in repair of exhaust fan AC 230/240V, heavy duty metal body, 300mm sweep complete with louvers including provision of hole for fixing of exhaust fan all as specified and directed by the Engr-in-Charge. Make : Usha/ CG/Havells/Bajaj
Supply and fixing of MCB DB SPN (double door) 6 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed by the Engr-in-Charge. Make :- Havells/Legrand/L&T.
Taking Down Carefully Submain wiring of size upto 10 Sqmm including making good disturbed surface of wall ceiling etc complete all as specified and as directed
Material and labour in repair for point wiring for Modular fitting, with 1.5 sqmm PVC insulated FRLSH unsheathed copper cable multistranded conductor 1100 volts grade, concealed type, controlled by one way switch including 1.5 sqmm PVC FRLSH insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through non metallic rigid PVC heavy duty concealed conduit of size 25mm dia with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc including 1.5 Sq mm, single core PVC insulated unsheathed multi stranded copper conductor FRLSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, complete complete all as specified and as directed.
All as per item No 162 here-in-before but for socket modular type 2 in 1,3 pin 5/15 Amp on independent board with 4.0 Sqmm PVC unsheathed copper cable and 4.0 sqmm copper conductor cable as earth continuity conductor complete as directed.
Supply & Fixing in repair modular switch single pole, one way, 6 Amp, 1 module, complete all as specified and directed. Make :- Carbtree/Legrand/Indo Asian.
Supply & Fixing in repair modular switch single pole, one way, 16 Amp, 1 module, complete all as specified and directed. Make :- Carbtree/Legrand/Indo Asian.
Supply & Fixing in repair modular Socket, 6 Amp, 2/3 pin combined 2 module, complete all as specified and as directed. Make :- Carbtree/Legrand/Indo Asian.
Supply & Fixing in repair modular Socket, 6/16 Amp, 2/3 pin combined 2 module, complete all as specified and as directed. Make :- Carbtree/Legrand/Indo Asian.
Supply & Fixing in repair modular Bell push 6 Amp, single pole, 1 module, complete all as specified and as directed. Make :- Carbtree/Legrand/Indo Asian.
Supply & Fixing in repair Bell ding dong type, complete all as specified and as directed.
Supply & Fixing in repair Modular step type fan regulator, 120W, 2 module, complete all as specified. Make :- Carbtree/Legrand/Indo Asian.
Supply and fix in repair 2' x 2' energy efficient recess mounting 24 watt LED lumanaries fixing for POP ceiling housing including LED lamps other accessories and necessary electric connection after and including taking down of old unservicable fitting complete all as specified and directed. Make : Havells Model No Octane+ LED Panel Square, Cat No PLANO2X2PLR24WLED840S or equivalent in Philips/CG.
Supply and Fixing in replacement MCB, single pole, 240 Volts, of capacity (6-32 Amps) 'C' series breaking capacity 10 KA. Make Havells/Legrand/L&T.
Supply and fixing in repair MCB SPN, 40 to 63 Amps, 240 Volts , breaking capacity 10KA complete all as directed. Make Havells/Legrand/L&T.
S&F in repair Down rod of size 60 CM with suitable arrangment for cealing fan hanging from S fram hook complete all as specified and directed.
M & L for dismantling of split AC 1.5/2.0 Ton capacity indoor unit by reversing of gas in compressor completly and reinstall the same after completion wall paneling work (B/R Work) complete with servicing of AC, testing all as specified and directed by Engr-in-Charge.
Supply, installation, commissioning and testing of wall split air conditioner comprising of indoor and outdoor units complete with cordless remote control unit and in-built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating of capacity 1.5 TR including electrical connection and heat insulated copper refrigerant tubing from outdoor to indoor unit all as specified and as directed. Make :- Hitachi/O General/Daikin.
Material and labour for framed brackets of angles or tees for fixing of outdoor unit of Split air conditioner including drilling, rivetting, welding as necessary and painting with one coat of red oxide primer and two coats of synthetic enamel paint all as specified and as directed.
M & L for Submain wiring with two run of 4.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through existing PVC conduit on walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 2.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly all as specified and as directed. Make :- RR Kabel/Havells/ Polycab.
M & L for copper tube 5/8" including jointing with existing copper tube for installation of outdoor unit of split AC all as specified and as directed.
M & L for copper tube 3/8" including jointing with existing copper tube for installation of outdoor unit of split AC all as specified and as directed.
M & L for Modular type mini MCB SP 3 kA 'C' series suitable for fixing in Modular Switch board, Make: Legrand/Havells all as specified and as directed.
M & L for MCB protected power unit for Air conditioner with MCB double pole 16-25 Amp, Starter unit 16-25 Amp and socket 16-25 Amp with plug top Cat No: DHDUCDP0253016-25 Havells/Legrand all as specified and as directed.
S & F Modular Socket 6A/16A - 2/3 pin combined 2 module in existing metal flush box complete all as specified and as directed. Make :- Havells/Legrand.
Material and Labour for Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3.0 KVA .Make V Guard/ Mircotek.
ARJUN DAS VALECHA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .