Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹14.7 L+₹49,890.70 (3.50%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹14.9 L+₹61,495 (4.32%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹14.9 L+₹63,434.50 (4.45%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹15.5 L+₹1.3 L (8.80%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹35,200
Closing Date
5 Apr 2022, 6:00 pmClosed
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
SPL REPAIR TO BLDG NO P 52 Ors LIVING OF WKSP COY UNDER GE SOUTH PATHANKOT
2022_MES_512259_1
GES/PKT/T-61/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹35,200
Yes
6 May 2022
7 Mar 2022
7 Apr 2022
7 Mar 2022
5 Apr 2022
22 Mar 2022
Amount
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) n exc. 1.50 Sqm each incl taking out hold fast.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exc. 1.50 Sqm but n exc. 4 Sqm each all as specified.
S&F pressed steel frames for door made out of MS Sheet 1.25mm thick of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc all as specified and directed.
S&F 35mm thick plain framed panelled door shutters of 2nd class hard wood (Factory made) two panel with lock rail and panel of 9mm thick BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 Part-I, Kiln seasoned and chemically pressure treated, fitted to chowkats complete all as specified and directed.
S&F 35mm thick 2nd class hard wood plain framed factory made glazed and skelton shutters open rebated and prepared to receive glass/ wire gauge etc (without sas bars)edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for secring glass,etc size of members of shuters as specified in SSR Part-I,Section 8, clause 8.24 (a) all as specified.
S & F floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed in floor over all length of cover plate 140mm thick complete all as specified and directed.
S&F factory made solid PVC door frame of size 50mmx47mm made out of 5mm plain colour sheet reinforcement with MS square tube. All as specified .
S&F factory made solid PVC door shutter, 28 to 30mm thick (style) with 2,4 or 6 raised panel design with 5mm moulded prelam PVC sheet on on the front face and 5mm plain colour PVC sheet on back face with wood free EPS all aws specified.
S&F 150mm size, extruded aluminium alloy handles, fabricated type, anodised.
S&F 150mm long aluminium tower bolts (ISI Marked) extruded type all as specified.
S&F in repair, 300mm, Mild steel spring for door, ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified.
S&F 300mm long Aluminium alloy, anodised,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F steel window/ventilator with tubular frame factory made double shutters of size 79mmx39mm,16 guage rectangular tubular frame with side hung shutter glazed and guaged with glazing bars 12x3mm flat iron incl projecting type hinges with steel handles and steel peg stay dovetailed or welded incl incluing necessary locking arrangment complete, incl two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed & shown on Drg No. CEPZ/TD-245/01 and 246/02 sheet 1/2 &2/2. (wire guage and glass shall be measured and paid seperately)
S&F Mild steel framed work such as grills, gratings using square/round bar with ends of bars shoulders/welded drilling holes for fixing of guard bars all as specified.
S&F Galvanised mild steel wire cloth 0.56mm of nominal dia of each wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples/wodden bedding
S&F in repair Galvanised mild steel wire cloth 0.56mm of nominal dia of each wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
M&L for Preparing the new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint all as specified.
M&L for Two coats of synthetic enamel paint on new wooden surfaces including preparation of surface and one coat of pink primer all as specified.
M&L for preparation of old painted steel surface of any description exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted wooden surface of any description exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Demolition of Brickwork or stone/ boulders masonry built in cement or cement lime mortar incl all quions, arches, pillars, etc but excluding ashlar facing, dressed stone work and precast concrete articles,
M&L for Brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cm (1:6)
M&L for Brickwork with old size fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built incm (1:6)
M&L Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces
Taking down cement plaster on brick or concrete surface and description including raking out joints hacking for key scrubbing down with water, M&L Rendering 5mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement as in ceiling and applying two coats of white wash complete all as specified.
Taking down cement plaster on brick or concrete surface and description including raking out joints Hacking for key scrubbing down with water, M&L Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement mixed with and including water proofing compound including two coats of cement base paint over a coat of primer on newly plastered surface of wall including preparation of surface and curing after applying each coat complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for keys scrubbing down with water, M&L Rendering 10mm thick in cement mortar 1:6 on fair aces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement including preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
Dismantling of floor tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, M&L non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick in CM 1:6 complete all as specified and directed.
Dismantling of wall tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, M&L Glazed ceramic coloured tiles of size 450 x 350 x 7mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4, all as specified and directed.
Dismantling of floor tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, M&L Vitrified Ceramic light shade tiles 9 to10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm laid over screed bed 15 mm thick in CM 1:6 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
Taking up or down GI pipes 15mm bore and connection including cleaning for refixing or removal un-serviceabl pipe, S&F GI tube 15mm bore medium grade galvanised ISI marked with all fittings complete on walls complete all as specified and directed.
Taking up or down GI pipes 20mm bore and connection including cleaning for refixing or removal un-serviceabl pipe, S&F GI tube 20mm bore medium grade galvanised with all fittings and fixed to short length complete all as specified and directed.
M&L PCC 1:5:10, type E-2, (using 40mm graded crushed stone aggregate) in foundation filling/sunken floor and mass concrete, all as specified & directed.
S&F Doctor fixit Pidifin 2k high performance 2 component flexible Acrylic polymer modify cement base water proofing coating in two coat 1mm thick dry film mixed in ratio 2:1 by weight or 1.5:1 by volume.
S&F in repair vitreous china wash down water closet pan (Orissa patern) white with integral foot rest of of size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe), including connection to trap, and to flushing pipe, anty syphonage pipe etc. and including 'P' and 'S' trap complete incl making good to floor complete all as specified and directed.
S&F for wash hand basin white colour, ceramic over counter ,oval shape,size 45x45x20cm, complete all as specified and directed.
S&F for SS Tubular towel rail of chromium plated, 20mm dia, D type, 60cm long between flanges, fixed in repairs complete.
S&F in repairs low level 10 ltrs capacity PVC valveless symphonic action type flusing cistern low level white with inlet ball valve float ovel handle including 32mm dia PVC flushing pipe complete all as specified and directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repair bib taps, fancy type, chromium plated, cast copper aloy ISI marked with crutch or butter fly handle high pressure screwed down for iron pipe of 15mm bore complete all as specified and directed.
S&F in repairs 15mm bore angle valve chromium plated screwed down fancy type high pressure screwd both ends for iron pipe of 15mm bore complete all as specified and directed.
S&F in repairs concealed type 15mm bore angle valve chromium plated screwed down fancy type high pressure screwd both ends for iron pipe of 15mm bore complete all as specified and directed.
S&F grating round 100 mm size of stain less steel as in repair, complete all as specified and directed.
S&F in repair chromium plated shower rose 75mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and directed.
M&L in repairs 100mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement type B-1 1: 2:4 and making good wall or floor tiling to match existing surface.
M&L 75mm CI Bends (any radius), with ovel acess door diminishing pieces or tapers (larger bore measured)
M&L 75mm CI Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches
S&F 100 mm dia sand Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall
All as per Srl item No 49 as above but 75mm
M&L 100mm CI Bends (any radius), with ovel acess door diminishing pieces or tapers (larger bore measured)
Taking down eaves gutters and rainwater pipes (any size or pattern),CI pipe including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
S&F mild steel curtain rods 25mm dia pre-laminated synthetic enamel paints of wooden finish fixed all as directed.
Supply and fxing wooden (turned, weathered & mitred) brackets pre polished with french polish with cut hole suitable for 25 mm dia rod fixed with screws and gutties in wall, including end caps with wall ornament and fixed to curtain rod with screws of design/shape complete all as specified and directed.
M&L for 18- 20 mm thick Granite ( table rubbed and polished) of any type work on cooking platform and like in cement mortar(1:4) including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite.
M & L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works; not exceeding 200 mm thick
M&L for one coat of white wash on ceiling incl preparation of old plastered surfaces complete all as specified and directed.
Complete removal of existing treatment from internal surfaces of walls by wire brushing and washing, rubbing down and stopping of surfaces , applying 1mm wall care putty on walls and make the surface of level, clean and repair disturbed edgs of bricks/concrete walls finish to even and smooth and applying two coat of oil bound distemper over a coat of primer all as spd and directed.
Hacking out old brocken glass (any thickness, size, quality or description) from wooden frame or stone, concrete or brick surrounds, gazed with putty or fixed with beads.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n exc. 0.50 Sqm in each pane all as specified.
Demolition of cement concrete ( unreinforced) in ground floors and pavings n exe 15 cm thickness. ( below or above ground level) all as specified.
M&L for TMT bars 10mm dia and over cut to length, bend to shape required including cranking, bending, spirally for hooping columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
S&F in repair SS chromium plated, plated peg set of four fixed with screw complete all as specified and directed.
M&L for 20mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed in repairs
Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including fillets. S&F in position suspended false ceiling system using E-grid suspended ceiling grid system. The size of grid shall be 600 x 600mm with GI frame work main runner 38 x 24mm cross tee 25 x 24mm and wall angle 24x24mm, using 8-9mm thick ceiling panel laminated with PVC film on front face and foil back availabel in due drop texture as per IS-2095, part-I-1996, fixid in the grid of E-grid suspended ceiling grid system duly suspended by 4mm dia GI wire and Fastener with RCC roof
Supply only Integral waterproofing compound
Dismantling water tanks (Capacity of tank exc 500 Ltr but n exc 1000 Ltr) and removing from site, S&F Rotational moulded polyethelyne water storage tank three layered (cylindrical vertical with closed top hoisted fixed in position all as specified in SSR part-I, capacity of tank 1000 ltr incl inlet and outlet connection 20mm dia and 15mm dia GI pipes medium grade respectively 20mm GI pipe medium grade over flow pipe 15cm long and brass valve 20mm high pressure with polyethelyne float and fly nuts complete all as specified.
M & L for hard core broken stone of gauge n.exc 63 mm deposited , spread and levelled in layers n.exc 15 cm thick, watered rammed to a true surface complete all as specified and directed.
M&L 75mm thick plain cement concret type C-2 1:3:6 (using 20mm graded crushed stone aggregate) as in flooring/Sub base/Plinth protection all as spd and directed.
Sand filling under floors or in foundations including watering and consolidation
M&L for Machine pressed precast concrete interlocking paver block 60 mm thick (Factory made rubber moulded) with grey cement and pigment any shape and size conforming to IS-15658-2006 of 60mm thickness, M-35 Grade fixed all as specified and directed .
M&L for preparation of old plastered or unplastered surfaces of wall including cornices plasters by brooming down with steel wire brushing, scrapping down smoke soot moulds, moss and efflorescent salt and trading oil & gressy spots etc and applying two coat of oil bound distemper on wall complete all as specified & directed.
M&L for preparation of old plastered or unplastered surfaces of wall including cornices plasters by brooming down with steel wire brushing, scrapping down smoke soot moulds, moss and efflorescent salt and trading oil & gressy spots etc and applying two coat of cement base paint on wall including curing after applying each coat complete all as specified & directed.
Providing and laying of water proofing treatment on roof with APP modified prefabricated five layer 3mm thick water proofing membrane super thermo lay with non woven polyster mat reinforement of 160 gsm weight of membrane @ 3.6 Kg/sqm over a solvent based bitumen primer or equivalent @ 0.3Ltr/Sqm by same manufacturer conforming to IS : 3384-1986 .The membrane shall be laid using butane torch .The end lap should be 100mm and the side lap must be minimum 75mm .The membrane shall be first laid up to the parapet wall junction and then shall be overlapped with another membrane(flashing) with an overlap covering upto a distance of 300mm .In case parapet height is less than upto 500mm,membrane shall be terminated at the top of parapet.All rain water pipes opening shall be suitable sealed with APP membrane complete all as specified and directed.
Dismantaling of old brick tile as in roof traetment and Cleaning of existing treatment of any description completely & washing rubbing with water
M&L 40mm thick brick tiles laid on cement mortar 15mm thick in CM 1:6 and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed.
All as per item No 77 but except brick tiles laid on cement mortar 15mm thick in CM 1:6 and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed.
PCC padding in roof slabs/chhajjas in PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate with and incl integral water proofing compound @ 3% weight of cement and providing necessary slope towards outside.
M&L rendering 10mm thick on concrete in CM 1:3 in facia or ediging of chajjas, ceiling and roof projection etc incl taking taking out pealed off plaster/concrete and making good to crackes in RCC surfaces in true line/shape by providing RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate including all necessary from work to thickness at required at GF and FF finish even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge. NOTE - The rate will inclussive of scafolding for single or double story including making holes in brickwork and making good in cement mortor.
Taking down carefully point wiring of any type, size and description from hard/ teak wood batten/through pipes/casing capping (light, fan, sockets and socket outlets etc) including removal of battens, pipes, plug sockets, socket outlets, switches, shades, ceiling roses, light fittings etc. complete and making good the disturbed surface to match with existing all as directed.
Taking down main switches, distribution boards and cut outs etc. of any type and capacity along with the existing boards and removing the same from site and making good the disturbed surface/portion of walls all as directed.
Taking down carefully sub main wiring of any nos of wire and size with earth wire from wooden batten/surface conduit/casing caping complete with its all accessories
M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories on surface wiring with top cover of 03 mm thick plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting & making good disturbed surface & applying finishes to match existing surface etc. all as specified for the following :-
One light/fan point controlled by one, one way switch single pole.
One 3 pin 5 Amps socket point on the same board.
One 3 pin 5 Amps socket point on independent board.
One light point controlled by two,two way switch .
One buzzer/bell point controlled by one, one way bell push.
All as per item No. 83 above but point wiring with 2.5 sqmm cable and 1.5 sqmm earth continuity conductor for 3 pin / 5 pin 15 Amps socket and all as specified and directed.
All as per item No 83 above but point wiring with 4 sqmm cable and 2.5 sqmm earth continuity conductor for 3 pin / 5 pin 15 Amps socket and all as specified and directed.
S&F switch piano, single pole one way 5 Amps 240 Volt capacity flush type all as specified and directed.
S&F Switch socket combination2 in 1 , 5 pin , 5 Amps flush type all as specified and directed.
S&F 3 pin 15Amps switch socket combination flush type multi purpose 2 in 1 type (3 pin 5 Amps and 15 Amps) all as specified.
S&F in repair ceiling rose of size 65 x 50 mm surface bakelite 240 Volts three terminal as specified and directed.
Supply and fixing sheet metal enclosure single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
S&F in repair stepped type electronic fan regulator flush type AC 230 volt suitable for any type of ceiling fan all as specified and directed.
S&F in repair Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
M & L for replacement of existing un-serviceable bell push with Modular bell push 6A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
S&F electric bell ding dong type AC 230 volt 50 Hz single phase single pole all as specified and directed.
Supply & Fix LED bulkhead fittings luminaires with opal diffuser including (LED lamp type 10W LED 6000K) lamp holder etc. complete all as required or directed.
Supply & Fix inverter type LED fitting 1 x 20W, including LED tube 4' long having bipin holder, connector blosk, driver etc 230 Volts, duly prewired and electrical connections upto ceiling rose using PVC insulated overall sheathed flexible copper conductor cable of size 0.5 Sq mm 03 core complete all as required or directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F LED Lamp 230 volts,50 Hz,inverter LED 12/15 watt ,lumen 900 lm, rated current 0.045A, CRI less than 80, Charging time 8 to 10 Hours, operating temperature -10 to 50 degree celcius,back time 04 Hours, complete all as specififed and direccted.
Supply & Fix in replacement ceiling fan AC single phase 230/240 volts of size 1200 mm sweep complete type BEE rated BLDC rated complete with blade set ,down rod, copper wound fan motor , canopy set, shackle kit etc including connecting to ceiling rose with 3 core 0.5 sqmm flexible copper wire all as required or directed . Note: Old retrieved fans shall be deposited to MES store yard by contractor
Supply & Fix Exhaust fan AC sinlge phase 230/240 volts of size 300 mm sweep steel body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
Supply and fixing in repair LED inverter street light 45W with RTC having luminium housing with clear toughened glass front coveer, IP 66 protection, operating voltage of 140V to 270V, having an efficiency of upto 02 hrs backup, reserve polarity protection , hight voltage cut off at 300V+- 10V and 5 KV internal surge protection with a power factor greater than 0.95 complete making connection with street light box or OH line using PVC insulated and sheathed single core multi stranded alumn conductor cable of size 2.5 Sqmm,all as directed.
Supply fixing and testing storage type electric water heater of 25 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc including dismantiling old unservicable geysers complete all as specified and directed.
Supply fixing and testing storage type electric water heater of 50 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc including dismantiling old unservicable geysers complete all as specified and directed.
Supply and draw sub main wiring in repairs of two run 6.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduit medium duty and accessories of not less than 25 mm size ISI marked including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of 2.5 sqmm single core PVC insulated unsheathed copper earth continuity conductor all as specified and as directed. (NOTE : Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length.) including making good disturbed surface all as specified and directed.
M & L for LT underground Cable XLPE insulated, heavy duty armoured sheathed 1100 volts grade 16Sq mm, 4 core, with aluminium conductor, ISI marked as per IS : 7098 (Part-1) complete with all as specified.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep hard /dense type of soil getting out and levelling of bottom surface to required level for poles/stay assebly/cable all as specifed and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25m thick all as specified and directed.
Removing excavated material from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point all as directed.
M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
Supplying & Laying in trenches clear sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified.
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 72 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 15000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 150 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
S&F in replacement iron clad, with double door 4 way IP-54, 1K-09 protection, cement sprill prptector sutable for MCCB as incommmer AC 415 Volts three pole with thermal release adjustable type (80% to 100%) and MCB as outgoing complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 ple 415 Volts 125 Amps rating with rupturing cap 25 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at sit or directed. (Outgoing MCB will be measured speparately)
Supply and fixing sheet metal enclosure for double door MCB DBs, phosphatised, powder coated, Single Pole & Neutral (SPN), suitable for 8 way, 240 volts, IP 43 & IK 09 fixed on wall with din rail, neutral and earth bar, in proper position and takingdown old one all as directed.
Supply & fixing MCB Single Pole and Neutral (SPN) of capacity 32 to 63 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position and takingdown old one all as directed.
Supply & fixing in repair MCB Single Pole (SP) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position all as directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
v k engineers and builders
VIKRAM SINGH MANHAS
M/S BISHAN DASS AND SONS
VIJAY CONSTRUCTION CO
BUILDEX CONSTRUCTION CO
M/s gurdial singh and co
M. C. ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .