Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
27 Oct 2026, 3:00 pm
Medical Superintendent IGH Shimla
Committe Room IGMC Shimla
Expression of Interest is hereby invited from the manufacturer or their authorized stockiest/distributors for empanelment of vendor to provide artificial appliances implants for Orthopedics procedures on credit basis in IGMC
2026_IGMC1_144880_1
HFW-MS-IG-EOI-Implants-9756
Open Tender
Miscellaneous Goods
Item Wise
365 days
The Medical Superintendent
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,500
IGMC
₹1 L
Yes
Committe Room IGMC Shimla
1 Oct 2026
1 Oct 2026
27 Oct 2026
1 Oct 2026
27 Oct 2026
17 Oct 2026
8 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Orthopedic Trauma, External Fixator, Paediatric Orthopaedic, Orthopedics Oncology, Spine, Pelvi Acetabular Fracture and Infected Non Union, Arthroplasty (Knee and HIP), Revision Knee and HIP Replacement System - Instrumentation and Implants required as per Bureau of Indian Standards "BIS"
NOTE:- As per BOQ Sr. No.001 to 259 for "STAINLESS STEEL" as per BIS Standard, item Sr. No.261 to 510 for "TITANIUM" as per nomenclature of Stainless Steel all Trauma Implant should be Titanium and all Arthroplasty Implants should be Imported but packaged in India and item Sr. No. 512 to 844 for "IMPORTED" as per nomenclature of Stainless Steel, must be USFDA, European CE Certified and approved. | - | - | - | - |
| 2 | TRAUMA | - | - | - | - |
| 3 | PROXIMAL FEMUR FRACTURE :- PROXIMAL FEMORAL NAIL (PFN) (All Sizes: Short/ Long) | 1 | Nos | - | - |
| 4 | PROXIMAL FEMUR FRACTURE :- PROXIMAL FEMORAL INTEGRATED SCREW and NAIL SYSTEM-INTERTAN NAIL (All Sizes: Short/ Long) | 1 | Nos | - | - |
| 5 | PROXIMAL FEMUR FRACTURE :- PROXIMAL FEMORAL HOOK PLATE | 1 | Nos | - | - |
| 6 | PROXIMAL FEMUR FRACTURE :- PROXIMAL FEMORAL LOCKING PLATE WITH SCREWS | 1 | Nos | - | - |
| 7 | PROXIMAL FEMUR FRACTURE :- ANGLED BLADE PLATE 95, 120, 135 DEGREE WITH INSTRUMENTATION | 1 | Nos | - | - |
| 8 | PROXIMAL FEMUR FRACTURE :- DOUBLE ANGLED BLADE PLATE 95, 120, 135 DEGREE WITH INSTRUMENTATION | 1 | Nos | - | - |
| 9 | PROXIMAL FEMUR FRACTURE :- TROCHANTER STABILISATION PLATE WITH INSTRUMENTATION | 1 | Nos | - | - |
| 10 | PROXIMAL FEMUR PLATE:- FOR PERIPROSTHETIC FRACTURE WITH CLAMP AND CABLE SYSTEM ALL SIZES WITH COMPLETE INSTRUMENTATION | 1 | Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
tenderdocuments.pdf
Tender Documents • 0.79 MB
BOQ_215588.xls
BOQ • 1.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .