Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹13.7 L+₹11,582 (0.86%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹15.5 L+₹1.9 L (14.2%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BANGALORE | BANGALORE | KARNATAKA | 560085 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹15.7 L+₹2.1 L (15.8%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L4 | Rejected-Finance Being not L1 |
Tender Value
₹14.8 L
EMD Value
₹29,500
Closing Date
5 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Neeraj Mehrotra, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
MAINTENANCE AND REPAIRS TO HT SYSTEM AND CNNECTED ITEMS AT AFS YELAHANKA
2023_MES_613127_1
86151/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Yelahanka
As per tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Yelahanka
₹29,500
30 Sept 2023
10 Aug 2023
7 Sept 2023
10 Aug 2023
5 Sept 2023
24 Aug 2023
10 Aug 2023 - 17 Aug 2023
Amount
Supplying and jointing in repair straight through jointing kit (Heat shrinkable) with all accessories suitable for HT 11 KV XLPE earthed UG cable of size 3 core, 95 Sqmm aluminum conductor and testing complete all as directed by the engineer-in-charge. (Make: Birla 3M/Denson/M Seal/Raychem)
Supplying and jointing in repair straight through jointing kit (Heat shrinkable) with all accessories suitable for HT 11 KV earthed XLPE earthed UG cable of size 3 core 120 to 185 Sqmm aluminum conductor and testing complete all as directed by the engineer-in-charge. (Make: Birla 3M/Denson/M Seal/Raychem)
Supplying and jointing in repair straight through jointing kit (Heat shrinkable) with all accessories suitable for HT 11 KV earthed XLPE earthed UG cable of size 3 core 240 to 400 Sqmm aluminum conductor and testing complete all as directed by the engineer-in-charge. (Make: Birla 3M/Denson/M Seal/Raychem)
Supply and fix in repair Indoor type cable terminations (heat shrinkable) with all accessories suitable for 3 core 11KV HT U/G XLPE earthed cable of size 95 sqmm Sq.mm including testing complete all as specified and as directed by Engr-in-charge. Make - M-Seal/Denson/Raychem or equivalent.)
Supply and fix in repair Indoor type cable end terminations (heat shrinkable) with all accessories suitable for 3 core 11KV U/G XLPE earthed cable of size 120 to 185 sqmm Sq.mm including testing complete all as specified and as directed by Engr-in-charge.(Make: M-Seal/Denson/Raychem) or equivalent.
Supply and fix in repair outdoor type cable terminations (heat shrinkable) with all accessories suitable for 3 core 11KV U/G XLPE earthed cable of size 95 Sq.mm including testing complete all as specified and as directed by Engr-in-charge.Make - M-Seal/ Denson/Raychem/Birla 3M or equivalent.
Supply and fix in repair outdoor type cable end terminations (heat shrinkable) suitable for 3 core 11KV U/G XLPE earthed cable of size 120 to 185 Sq.mm including testing complete all as specified and as directed by Engr-in-charge. (Make:M-Seal/Denson/Raychem/Birla 3M) or equivalent.
M & L for fault finding of HT 11 KV 3 core, XLPE cable of size 95/120/185 sqmm by thumping and echo instrument/ computer aided fault finding kit, and finding out exact location of the fault complete all as specified and directed by Engr-in-charge. Note :(i) Necessary excavavation, reterning refilling and removal of soil shall be measured and paid separately under relevant items of the schedule.
Dismantling insulators of any type and any size all as directed.
M/L for pin type porcelain vitreous white, brown or green insulators including one galvanised mild steel spindle two galvanised iron washers one GI nut 150mm height 150mm dia for 11 KV complete all as specified and directed by Engr-in-charge.
M/L disc insulator porcelain vitreous 145 mm high and 255mm dia ball and sockent type, white brorwn or green single disc assembly complete all as specified and directed by Engr-in-charge.
Taking down GOD alongwith dropout fuse assembly of any capacity all as directed by Engr-in-charge
Supply and fix TNC switch suitable for existing 11KV VCB 630 Amps/800Amps complete all as directed by Engr-in-Charge.
M & L for gang operated device (GOD) HT 11 KV outdoor type suitable for vertical mounting fixed type complete with insulators and frame with operating mechanism (including GI pipe medium grade 25mm dia pipe, necessary supports) worked from ground level complete with locking arrangements including pad locks with key of rating 400 Amps all as specified and directed. (Make Jayashree/Jayapuria/BHEL/GODREJ)
M&L for expulsion fuse unit assembly, out door type, single pole 50 Amps capacity including fuse element 25 Amps to 50 Amps and insulator conforming to IS specifications suitable for HT 11KV all as specified and directed.
M&L for jumper connections between GOD and drop out fuses and transformers with ACSR conductor 6/1X3.35 mm (rabbit) not exe. 2 mtr long including necessary lugs where ever required /aluminum heavy duty PG clamps / binding properly without any loose contact all as directed after removing the old jumpers including PVC sleeve not more than 1.70 Rm all as specified and as directed.
All as per item No. 16 above length exceeding 2 mtr but not exe. 3.5 mtr long including PVC sleeve not more than 3.2 Rm
Supply and fix tripping coil box assembly with coil 30V DC for HT 11KV VCB 630 Amps/800Amps of make Crompton/ ABB all as specified and as directed.
Material and labour for repair and servicing of HT 11KV four pole structure by repalcing galvanized PG clamps, GI bolts and nuts,pieces of ACSR conductor with insulation of any size as jumpers including lubricating the moving parts of AB switch and cleaning of all disc/pin insulators and applying silicon compound for prevention of arcing due to dust/salt deposits over the surfaces including applying one coat of red oxide primer on rusted portions after preparation of surfaces & applying a coat of aluminium paint to the entire steel structure complete all as specified and directed.
Material and labour for repair and servicing of HT 11KV two pole structure by repalcing galvanized PG clamps, GI bolts and nuts, pieces of ACSR conductor with insulation of any size as jumpers including lubricating the moving pars of AB switch and cleaning of all disc/pin insulators and applying silicon compound for prevention of arcing due to dust/salt deposits over the surfaces including applying one coat of red oxide primer on rusted portions after preparation of surfaces & applying a coat of aluminium paint to the entire steel structure complete all as specified and directed.
Supply and refilling SF6 gas in cylinder of RMUs/VCBs/HVDB complete all as specified and directed by Engr-in-Charge.
Checking & testing of DI-electric strength of transformer/servo controled voltage stabilizer/isolation transfomers and sutmit to Engr-in-Charge all as specified and directed.
Online Centrifuging (filteration/dehydration) of transformer oil including checking initial and after filteration Dielectric Strength of oil for transformers, Isolation transformers and voltage stabilizers located in various places of technical and domestic area with suitable machine having filteration, heating and pumping facility to improve the dielectric strength/insulation value of oil. Note :- (i) Di electric strength of oil after filteration/dehydration shall not be less than 60 KV at 2.5 mm gap. (ii) Oil for toping up shall be measured and paid separately under relevant item of this schedule (iii) The contractor will take shut down orders in writing atleast two days before from Engr-in-charge before commencement of work. (iv) The dielectric strength of oil shall be tested before and after filtration and necessary test certificates shall be submitted to the Engr-in-chaerge.
Supply & topping up of new transformer oil conforming to IS-335/1983 for transformer/VL unit/Isolation transformer/Servo Voltage Stabilizer, up to the marked level all as specified & as directed by Engr-in-charge Note: (i) Mineral oil grade shall be used. (ii) The transformer oil should have a IR value of the oil should not less than 60KV/Min (iii) The quoted rate shall be deemed to cost of filtration and testing etc.
Supply and fix the silica Gel container (breather) including silica Gel suitable for the transformers of capacity 50 KVA to 200 KVA after dismantling the old U/S breather complete all as specified and directed.
Supply and fix the silica Gel container (breather) including silica Gel suitable for the transformers of capacity 250 KVA to 500 KVA after dismantling the old U/S breather complete all as specified and directed.
Supply and fill silica Gel for 11KV/415V Transformers rated of various capacities by replacing the contaminated one from the transformer
Supply and fix free trip mechanism suitable for existing 11KV VCB 630 Amps/800Amps of make Kirloskar/ABB all as directed.
Material and labour for repairs to transformer at various locations of technical and domestic area after removing nuts and bolts of transformers of capacity 200 to 500 KVA and taking out the leaked portion such as bushes, joints, and replace the gaskets after cleaning the surface and refixing the nuts and bolts and ensure no leakagre complete all as specified and directed by Engr-in-charge.
All as per item No. 29 above but transformer of capacity 50 to 160 KVA
Opening carefully and replace the clear acrylic sight window cover along with gasket of oil level indicator of the transformer of capacity 100 KVA to 400 KVA all as specified and as directed.
M&L for painting distribution transformers/Isolation Transformers/Voltage stablizers with two coats of synthetic enamel paint after neatly cleaning and preparing the surface all as directed for the transformers of 50 to 200 capacity including writing SM/MES No. with white colour synthetic enamel paint all as specified and directed.
Checking & testing of out door transformers of any type / capacity for IR value by applying 5000 V / 500 V by means of HT / LT meggar after removing primary / secondary terminal connections including reconnecting and charging back the transformer all as specified and directed by Engr-in-charge. Note : Test results obtained shall be recorded and produced to Engr in Charge in proper format duly signed by the contractor.
Supply & fix porcelain vitreous HT 11 KV bushings with copper/brass studs suitable for out door distribution transformers of capacity upto 400 KVA after removing the old unserviceable studs / bushings and draining out the transformer oil from the top level up to conservator of the transformer and removing the top cover of the carefully and refixing and refilling the oil all as directed.
All same as per item No. 34 here in before but LT bushings.
Supply and fix Tap changeover mechanism for 400/500 KVA step down transformer as per existing make.
Supply and fix Tap changeover mechanism for 125 to 300 KVA step down transformer as per existing make.
Supply and fix Tap changeover mechanism for 50/100 KVA step down transformer as per existing make.
Repairs/Servicing of VL switch 11KV including cleaning of complete system taking down old ruptured fuse units replace with new fuse and filteration of existing oil and making good of the fixed and moving contacts, connecting the switch for operation and testing including painting with two coats of synthetic enemel paint complete all as specified and directed by the Engr- in-Charge all as specified and as directed.
M&L for Servicing to vaccum circuit breakers (Make: KIrloskar/ABB) of rating 630/800 Amps, 11 KV, 3 Phase of different Make by removing incoming and outgoing cable connections, moving and fixed contacts cleaning the parts with CTC, servicing contacts, checking the VCB panel healthiness of faults tripping system by using secondary injection method and checking breaker, closing coils, improving the insulation resistance and re-assembling the same with new or old spares and checking the proper functioning of the whole VCB all as specified and as directed. Note :- (i) New spare shall be measured and paid separtely under relevant items of schedule 'A'. (ii) Hiring of technician/service engineer from Kirloskar/ABB is the responsibility of contractor and rate for the same deemed to be included in the quoted rate.
Disconnect and taking out the Numeric/ Microprocessor based relay including earth fault and over current relays of any type of any Make from 11 KV HT panel, cleaning the contacts, calibrating the relay by conducting secondary injection tests, checking of current transformer, rectification of defects in control wiring for proper tripping of circuit breakers through CTs and relay and tripping coils, adjustment/setting to plug and time multiplier settings of the relay to achieve the discrimination in tripping, tune/synchronies upstream breaker relay settings, re-installation of relay, testing & commissioning etc complete all as specified and as directed. Note: The Contractor has to arrange necessary testing Kits, testing equipments, tools etc and shall also submit detailed test reports, panel wise, duly spiral bound. Rental rates for the testing/calibration kits & connected equipments are deemed to be included in the quoted rate. Testing & tuning shall be carried out in the presence of representative of the Department, to the satisfaction of the Department.
Supply and fix Earth fault relay (Electro Mechanical) complete all as specified and directed by Engr-in-charge.
Supply and fix Over Current Relay (Electro Mechanical) complete all as specified and directed by Engr-in-charge.
Supply only LED Indication Lamps 24 V DC/AC Neon type (R/Y/B) complete all as specified and directed by Engr-in-charge.
Supply and fix surge arrestor(set of 3) suitable for existing 11KV HT VCB/ VCBs/RMUs panels of capacity 800A/630A for protection of installations from external surge including testing complete all as specified and directed by Engr-in-charge.
Supply and replacement of PT 3 phase 3 limb single ratio 11KV/110V, 150VA per phase, 2 core & accuracy Class-1 for 11 KV, 630 Amps RMU of Siemens make complete all as specified and directed by Engr-in-charge.
Supply and fix closing coil box assembly with coil suitable for existing VCB of make (Kirloskar/ABB) 30 V DC for HT 11 KV VCB 630 Amps all as specified & directed.
M & L for servicing of servo controlled volatge stabilizer of capacity 100 KVA of make : Powerone, situated at AF NET SITE-II by disconnecting the LT cables and draining out oil complete and taking out the core and checking the continuity and insulation values of all three phases, reinsulating if required and inspecting and replacing the PCB in case of repair, repair and servicing of breaker, removing and cleaning the sludge from the tank, refilling the oil after filtering by using online centrifuge machine and obtain the dielectric strength of oil not below 100 KV at 2.5 mm gap including testing of the volatge stabilizer by reconnecting the disconnected cables and calibrating complete all as specified and as direcrted. (Filtration of oil by using online centrifuge machine and top up of oil will be measured and paid separately under relevant items of the schedule). Note : The rate shall also deemed to be included the rate for (i) Technician, Electrician,and labours (ii) Supply and fixing of drain valve to the voltage stabilizer suitable for of make : Power one.
M & L for servicing of Servo Controlled Voltage Stabilizer of capacity 50 KVA of Make : Power one situated at Signal Section by disconnecting the HT/LT cables and draining out oil complete and taking out the core and checking the continuity and insulation value of coils for all three phases, inspecting and reinsulating coils if required, repair and servicing of breaker, replacing the wornout parts if any, removing and cleaning the tank, refilling the oil after filtering by using online centrifuge machine and obtain the dielectric strength of oil not below 60KV incliuding testing of the voltage stabilizer by reconnecting the disconnected cables and calibrating complete all as specified and as direcrted.(Filtration of oil by using online centrifuge machine and top up of oil will be measured and paid separately under relevant items of the schedule). Note : The rate shall also deemed to be included the rate for (i) Technician, Electrician,and labours (ii) supply and fixing of drain valve to the voltage stabilizer.
M&L for Servicing to Ring main unit (Make: Seimens) of rating 630/800 Amps, 11 KV, 3 Phase by removing incoming and outgoing cable connections, the control circuit wiring, checking of oprerating, spring charging and interlocking mechanism and ascertaining the RMU healthiness of faults tripping system by using secondary injection method and checking breaker, closing coils, improving the insulation resistance and connecting all cable connections and checking the proper functioning of the whole RMU including replacement of minor items all as specified and as directed. Note :- (i) Hiring of technician/service engineer from Seimens is the responsibility of contractor and rate for the same deemed to be included in the quoted rate.
Supply and fix cable termination bushing for 11 KV, 630 Amps RMU of Siemens make complete all specified and directed by Engr-in Charge.
Supply and fix cable termination booting for 11 KV, 630 Amps RMU of Siemens make complete all specified and directed by Engr-in Charge.
Supply and fix fault failure relay for 11 KV, 630 Amps RMU of Siemens make complete all as specified and directed by Engr-in-charge.
M&L for SS tank cutting and rewelding and gas leakage checking of 11 KV, 630 Amps RMU of Siemens make complete all as specified and directed by Engr-in-charge.
Supply and replacement of PT 3 phase single ratio 11KV/230V, 150VA per phase, 2 core & accuracy Class-1 for 11 KV, 630 Amps RMU of Siemens make complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in deep and getting out in hard/dense soil for laying underground cable, foundation etc all as specified and as directed.
Returning and filling of trenches in two parts (i) using riddled soil obtained from excavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note: - Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning.
Removing excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 flat of size 300mm x 180mm x 40mm complete all as specified and directed.
Supply, Lay, testing and commissioning of HT UG cable XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor, 11000 volts grade of size 3 core 95 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed.
Supply, Lay, testing and commissioning of HT UG cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored electric power cable (heavy duty earthed) with stranded aluminium conductor,11000 volts grade of size 3 core 120 Sqmm complete laid in trenches or fixed on walls /floors etc.all as specified and as directed.
RAMESH BABU CO
Lucky Enterprises
M/S SRI BALAJI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .