Tender Value
₹20.0 L
EMD Value
₹39,903
Closing Date
15 Sept 2026, 4:00 pmClosed
EE(E) C-V
Office of EE(E)C-V, Room No. 1802, 18th Floor Palika Kendra, New Delhi-110001
Replacement of DG Room Ventilation system (AIR washer)17000 CFM at Block C NDCC Phase-II Building
2026_NDMC_297752_1
01/EE(C-V)/2026-27
Open Tender
Electrical Works
Percentage
60 days
NDCC phase-II building, Block-C NDMC area.
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹39,903
Yes
9 Oct 2026
31 Aug 2026
15 Sept 2026
31 Aug 2026
15 Sept 2026
31 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, installing, testing and commissioning of cellulose fill air washer. Air washer shall be factory assembled and complete with 16 gauge Gl sheet casing, fans section, FRP steel reinforced tank of 3 mm thick, DIDW centrifugal forward curved fan, cellulose filling and water distribution header, Gl piping with braze valves and fittings between pumps and air washer, 50 mm thick HDPE /Aluminum filters. Capacity 17000.CFM | 4 | Nos | 3,25,326 | ₹13,01,304 |
| 2 | Supply, fabrication, installation and testing of galvanized sheet metal ducts including splitter damper, duct flanged and supports in accordance and as required by the GI sheet shall be of class VIII construction (1.00mm, 20gauge) | 160 | Sq. metre | 2,999.56 | ₹4,79,929.6 |
| 3 | Supply, installation and testing and commissioning of fire control Damper made of heavy gauge GI sheet /galvanized steel frame with motorize fire controller and multiple aerofoil blades , designed to automatically close in case of fire to prevent the spread of flame and smoke through HAVC ducts. Damper shell is fitted with automatic Operation and manual reset arrangement | 4 | Sq. metre | 14,799.56 | ₹59,198.24 |
| 4 | Supplying and installation of acoustic/thermal insulation of ducts with 19 mm thick closed cell elastomeric nitrile rubber insulation of tissue fabric, finally cover with 28 gauge Al sheet as per specifications | 220 | Sq. metre | 514.48 | ₹1,13,185.6 |
| 5 | Supply, installation, testing and commissioning of GI medium class water piping for fresh water and drain, including all necessary fittings, supports and necessary accessories (for Ventilation and Cooling Tower , Size 40 mm or as site requirement) | 160 | metre | 259.6 | ₹41,536 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.94 MB
BOQ_396788.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .