Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹18.0 L+₹18,838.50 (1.06%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹21.1 L+₹3.3 L (18.4%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹24.7 L+₹6.9 L (38.6%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 |
| Sl No | Description | Qty | Unit | CHINAR CONSTRUCTION TRADERS L4 | M/s Alam-i-Afroz L2 | M/S NEW FAROOQ TRADERS L1 | M/S UTA MOTORS L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down unservicable faulty under ground cable of all sizes from trenches/pipes including taking out bricks and complete all as specified and directed. | 1,155 | RM | 5 ₹5,775 | 10 ₹11,550 | 10 ₹11,550 | 2 ₹2,310 Lowest |
| 2.00 | M&L in replacement of Supply, jointing and testing, HT cable 11000 volts grade of cross sectional area 95 Sqmm 3.5 Core as per IS-7098 (Part-I) 2011, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes, security lights, LT panels etc) for incoming and outgoing cables complete all as specified and as directed. | 60 | RM | 913 ₹54,780 | 1,100 ₹66,000 | 890 ₹53,400 Lowest | 1,070 ₹64,200 |
| 3.00 | M&L in replacement of Supply, jointing and testing, LT cable 1100 volts grade of cross sectional area 240 Sqmm 3.5 Core as per IS-7098 (Part-I) 2011, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes, security lights, LT panels etc) for incoming and outgoing cables complete all as specified and as directed. | 615 | RM | 2,100 ₹12,91,500 | 1,300 ₹7,99,500 Lowest | 1,440 ₹8,85,600 | 1,700 ₹10,45,500 |
| 4.00 | M&L in replacement of Supply, jointing and testing, LT cable 1100 volts grade of cross sectional area 95 Sqmm 3.5 Core as per IS-7098 (Part-I) 2011, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes, security lights, LT panels etc) for incoming and outgoing cables complete all as specified and as directed. | 180 | RM | 900 ₹1,62,000 | 600 ₹1,08,000 | 605 ₹1,08,900 | 550 ₹99,000 Lowest |
| 5.00 | M&L in replacement of Supply, jointing and testing, LT cable 1100 volts grade of cross sectional area 50 Sqmm 3.5 Core as per IS-7098 (Part-I) 2011, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes, security lights, LT panels etc) for incoming and outgoing cables complete all as specified and as directed. | 75 | RM | 520 ₹39,000 | 400 ₹30,000 | 300 ₹22,500 Lowest | 350 ₹26,250 |
| 6.00 | M&L in replacement of Supply, jointing and testing, LT cable 1100 volts grade of cross sectional area 25 Sqmm 3.5 Core as per IS-7098 (Part-I) 2011, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes, security lights, LT panels etc) for incoming and outgoing cables complete all as specified and as directed. | 115 | RM | 300 ₹34,500 | 250 ₹28,750 | 210 ₹24,150 Lowest | 270 ₹31,050 |
| 7.00 | M&L in replacement of Supply, jointing and testing, LT cable 1100 volts grade of cross sectional area 16 Sqmm 4.0 Core as per IS-7098 (Part-I) 2011, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes, security lights, LT panels etc) for incoming and outgoing cables complete all as specified and as directed. | 110 | RM | 270 ₹29,700 | 170 ₹18,700 | 150 ₹16,500 Lowest | 210 ₹23,100 |
| 8.00 | Excavation in trenches n.exc 1.5 M wide and n.exc 1.5 M depth and getting out for laying of underground cable etc in any type of soil complete all as specified and directed Engineer-in-Charge. | 229.5 | Cum | 150 ₹34,425 | 100 ₹22,950 | 100 ₹22,950 | 80 ₹18,360 Lowest |
| 9.00 | Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25 cm thick in any type of soil complete all as specified and directed by Engineer-in-Charge. | 145 | Cum | 50 ₹7,250 | 50 ₹7,250 | 25 ₹3,625 Lowest | 40 ₹5,800 |
| 10.00 | Removing of excavated soil to a distance n.exc 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed Engineer-in-Charge. | 84.5 | Cum | 50 ₹4,225 | 25 ₹2,112.5 Lowest | 25 ₹2,112.5 Lowest | 40 ₹3,380 |
Tender Value
₹19.8 L
EMD Value
₹39,560
Closing Date
17 Oct 2025, 6:00 pmClosed
CWE AF SRINAGAR
CWE AF SRINAGAR
SPECIAL REPAIR TO E/M INFRASTRUCTURE OF KV SCHOOL AT 1 WG, AF STN SRINAGAR
2025_MES_731309_1
CWE(AF)SGR/AWA-25/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF SRINAGAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF SRINAGAR
₹39,560
Yes
13 Nov 2025
17 Sept 2025
22 Oct 2025
17 Sept 2025
17 Oct 2025
3 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.56 MB
Tender Documents
Tender Documents • 0.75 MB
BOQ
BOQ • 1.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .