Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC KOTWALI STREET MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MP | 474006 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹15.7 L+₹1.4 L (9.95%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹16.0 L+₹1.8 L (12.4%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹16.1 L+₹1.8 L (12.5%)Rejected-Finance NARMADA COLONY BARADARI CHOURAHA MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹16.1 L+₹1.8 L (12.9%)Rejected-Finance C O PRAMOD KUMAR SHAH BUS STAND NANDPRAYAG NANDPRAYAG CHAMOLI UTTARAKHAND 246429 | NANDPRAYAG | CHAMOLI | UTTARAKHAND | 246429 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
12 Feb 2024, 6:00 pmClosed
Garrison Engineer Gwalior
Garrison Engineer Gwalior Morar Cantt
8928/GWL/E8 SPECIAL REPAIR WK OF BLDG NO T-29 AND PROVN OF GUARD POST AT STN HQ GATE IN THE AREA OF AGE B/R-I UNDER GE GWALIOR
2024_MES_637489_1
8928/GWL/E8
Open Tender
Civil Works
Works
180 days
Garrison Engineer Gwalior
Please refer tender documents
9 documents required · 9 mandatory
₹500
Garrison Engineer Gwalior
₹42,000
Yes
9 Mar 2024
15 Jan 2024
16 Feb 2024
15 Jan 2024
12 Feb 2024
30 Jan 2024
Amount
Demolition of cement concrete of any description and in any position (unreinforced) in ground floors/ paving not exceeding 15 cm thick (below or above GL) complete all as specified and directed.
M&L for 75mm thick PCC 1:2:4 type BO (using 12.5 mm graded BT stone aggregate) as in floor complete all as specified and directed .
M&L for 75mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection/Path/paving ect surface even and smooth without using extra cement complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry built in cement or cement lime mortar including all quoins, arches, pillars etc. and removing the same outside MOD land complete all as specified and as directed.
M&L for walling of random rubble uncoursed, well bonded,bedded and solidly hearted built in CM 1:6. complete all as specified and directed.
Taking down cement or cement lime plaster incl wall tiles, any description, on brick ,stone and concrete surface walls including chhajja of any floor and roof projection etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed .
M&L for 15 mm thick rendering in cement mortar 1: 6 on fair faces of brick work or concrete surfaces, finished fair and smooth complete all as specified and directed.
M&L for 15mm thick rendering on brick or stone/concrete any surfaces in cement mortar 1: 4 on mixed with WPC @ 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured & paid seperately.
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed .
M&L for complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrapping or any other means, complete all as specified and as directed.
M&L for applying three coats of white wash on wall surface complete all as specified and as directed.
M&L for applying two coats of cement base paint over a coat of primer including preparation of newly plastered surface of walls complete all as specified and as directed.
M&L for complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrapping or any other means, includind removing vegetable/plants root from walls/chajja's complete all as specified and as directed.
M&L for applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
Taking down chowkhat with shutter (without taking off shutters from the frame) exc 1.5 Sqm but n.exc 4.00 Sqm each complete all as specified and as directed.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S&F for 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane complete all as specified and as directed.
M&L for preparation or new steel and iron surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer on old steel surfaces including preparation of surfaces complete all as specified and directed.
Demolition of cement concrete unreinforced in Roofs, floors (other than ground floors),beams,stair cases,landing,chajja,s and similar suspended work complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in roof kerbs/coping/ bed block complete all as specified and directed.
Taking down eaves gutters and rain water pipes (any size 75mm to 110mm of any pattern) of any description and in any position, including all fittings , heads, shoes, bends, swan necks, etc., (measured overall as fixed along the centre line over fittings and accessories)complete all as specified and directed.
S&F for 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and directed.
M & L fixing of precast RCC bond stone 50mm thick in brick /stone walls complete all as specified and directed.( note Reinforcement shall be measaured and paid in separate item)
M&L for TMT bars 10 mm dia and over as in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hoping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
S & F chicken wiremess with tack screws of galvanised mild steel wire cloth of 0.56mm nominal dia of wire and average width of aperture 1.18mm complete all as specified and directed.
M&L for preparation surfaces for building Nos and applying one coat of synthetic enamel paint and writing letters or figures (Block, Roman, Italic or Indian) of n exc 10cm height, width of letter shall not be less than 15mm, including stops, commas, lines, brackets and making outer boarder with approved tint of synthetic enamel thick paint complete all as specified and as directed.
Dismantling of AC (corrugated / semi-corrugated) sheets in roof covering including any type of ridges complete all as specified and as directed.
S&F Pre painted galvalum aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having aluminum zinc coating 150 gms/ sqm steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F Pre painted galvalum aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having aluminum zinc coating 150 gms/ sqm steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall, valley gutter fixed with self tapping screws complete all as specified and directed.
S & F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering. Doors,etc. to be prepaired for having or sliding with and including either hooks and hinges or steel hanging door fittings (excluding of steel sheeting or other covering, running rails and guiders) and hanging, valley gutter also fastening and fixing complete all as specified and directed.
S&F for flat iron of size 50x5mm thick wind ties fixed to CGI/Galvalume sheets on roof including or necessary drilling, bolting or riveting etc confirming to Fe- 290 grade E-165 complete all as specified and directed.
S&F for 4mm thick Fibre glass reinforced translucent plain sheeting with side lap fixed with coach screw and washer in roof, wall cladding etc complete all as specified and directed.
S&F for in repairs Steel rolling shutters, thickness of lathing 1.25mm, with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete gear operated type with bevel gear box and crank handle complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 deep and getting out in soft/ loose soil complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in loose/soft soil complete all as specified and directed.
Earth filling under floor spreading, levelling in layer n exc. 25cm thick incl well raming and watering as required all as specified and directed.
M&L for Cement concrete (1:4:8) type D2 (using 40mm graded stone agg) as in fdn, filling and mass concrete complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C1 (using 20mm graded stone agg), finished even and smooth without using extra cement as in plinth protection including forming of joints 10mm wide and 75mm deep and joint filled with bitumin and sand mixture in 1:1 ratio complete all as specified and directed.
M&L for Hard core of gauge exc 63mm but n.exc.100mm size, deposited, spread and levelled in layer n.exc. 15cm thick, watered and rolled/ rammed to a true surface complete all as specified and directed.
M&L for reinforced cement concrete (1:1 1/2:3) type A-1 ( using 20 mm graded stone aggregate ) as in beams , cantilevers bressummers ,Chajja, lintel over 1.5 m span etc. complete all as specified and directed.
M&L for Formwork to sides of concrete, in foundations, footings, columns , beams and Chajja, etc in flat for rough finshed surfaces of concrete complete all as specified and directed.
M&L for mild steel TMT bars ,10mm dia and over, cut to length bent to shape required including cranking bending spirally for hoping for coloumns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
M&L for Brick work with sub class `B' bricks straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed..
M&L for Brick work with sub class `B' bricks straight or curved on plan exc 6m mean radius, built in CM 1:4, in half brick thick walls complete all as specified and directed.
M&L for vitrified ceramic tiles 8 to 10 mm thick, light shade (square/rectangular) polished,area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 as in floors complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface of size 350mm x 250mm x 7mm/ 450 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10 mm thick rendering on fair faces brick work or concrete surface in cement plaster 1:4 complete all as specified and directed.
M&L for Granite slab 18 mm to 20 mm thick machine cut, bedded and joined with cement and pointed with white cement with admixture of pigment to match over and including 20 mm thick screed bed CM (1:3) .the shade of granite stone including cutting and polishing type as in cill and jamb/skirting, steps cooking plateforms includigng rounding off the exposed edges and polishing all as specified and directed..
S& F for anodised aluminium snap grid frame work for false ceiling consists of powder coated aluminium angle of size 22x22x1.3 mm and Tee of size 35x25x1.3 mm and grid of size 605x605 mm with Hanger 3-4 mm dia G I (upto reqd length) adjusting level fixed to roof slabs by means of ceilling cleats complete all as specified and directed.
M&L for 6 mm thick non asbestos fibre cement building boards fixed or laid/ inserted to Aluminium anodised frame and hanges frame work fixed complete all as specified and directed.
M&L for Rotational moulded polyethylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position with ball walves 20mm PTMT complete all as specified and directed (min weight 210 gms).
S&F for 20 mm bore gun metal globe / gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S & F for 75 mm dia out let PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified & directed.
S & F for Bib taps, cast copper alloy chromium plated with crutch or butterfly handle (Long body), screwed down, screwed for iron pipe of bore 15mm complete all as specified and directed.
S & F for Stop valves, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe 15mm bore complete all as specified and directed.
S & F for PVC connection 600mm long with CP nuts with washers ends 15mm bore complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring jointsfixed on walls complete all as specified and directed.
S & F for tubes medium grade GI with all fittings 15mm bore fixed walls complete all as specified and directed.
S & F for tubes medium grade GI with all fittings 20mm bore fixed walls or laid in floors as in over flow pipes complete all as specified and directed.
S & F for Anodised powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors , windows , ventilators, partitions with one or more rebates including jointing cleat for fixing etc complete all as specified and directed.
S & F for anodised powder coated aluminium door shutters, windows, ventillators aluminium section weighing not less than 0.55 kg/m including necessary jointing cleats, Glazing clips , rubber neoprene packing, 150mm long handles two numbers in each door, 100mm long brass hinges, 200mm long aluminium tower bolts, anodised aluminium snap beading screws etc including M&L for fixing godrej lock in each door & minimum six Nos keys with each lock complete all as specified and directed.
S&F for 9 mm thick prelaminated particle board exterior grade prelamilated both sides with decorative choice lamination and other side balancing white lamination fixed with screws complete all as specified and directed.
S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe 290,Gde E-165 complete all as specified and as directed .
S&F for flat iron of size (40x3)mm thick wind ties fixed to CGI/Galvalume sheets on roof including or necessary drilling, bolting or riveting etc confirming to Fe- 290 grade E-165 complete all as specified and directed.
M&L for Preparation of new steel surfaces over 10cm width or girth and applying 02 coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and directed.
M&L for Preparation of new plastered surfaces of walls and applying 02 coats of oil bound distemper over a coat of suitable primer complete all as specified and directed.
M&L for Preparation of new plastered surfaces of walls and applying two coats of weather proof water based emulsion paint ( Acrylic paint exterior grade) over one coat of primer complete all as specified and directed.
M&L for 100 mm thick, PCC (1:4:8) type D-2, (using 40 mm graded stone aggregate), as in sub base for floor, finished even and rough complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
M&L for 60 mm thickness machine pressed precast concrete interlocking paver block M-35 any shape and size confirming to IS 15658-2006 in grey cement glossy finish rubber mould casted laid dry over sand cushioning complete all as specified and directed.
Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed.
Taking down Wall fan of any sweep,removing blades, cleaning the fan completely of dust and dirt and Re-hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including renewal of old unserviceable fan hook rubber pad, nut bolts and washers etc, complete all as specified and as directed by Engr-in-charge.
Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten complete all as specified and directed.
Taking down unserviceable Sheet metal box & MCB DB SPN with MCB's of any make/capacity, complete, all as specified and directed .
Taking down unserviceable TPN DB with MCB's of any make/capacity complete all as specified and directed.
M&L for conduit point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade( ISI marked with valid CML No) not less than 20 mm dia with all fitting and fixing accessories and 1.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes factory made for mounting switch, regulators etc with and including 2.8 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches. sockets etc complete all as specified and directed.
One light point controlled by one switch.
One Ceiling fan point controlled by one switch.
One 3 pin socket outlet 5 Amps controlled with one switch on the same board.
One 3 pin socket outlet 5 Amp controlled by one switch on independent board complete all as specified and directed.
Description all as per item No. 79 here in before but point wiring with 2.5 sqmm FRLSH confirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire complete all as specified and directed.
S&F for switch piano, flush button single pole one way 5 Amp complete all as specified and directed.
S&F for Switch socket outlet, 5 Pin, 6 Amp 2 in 1, flush type, universal complete all as specified and directed.
S&F for switch piano, flush button single pole one way 15 Amp complete all as specified and directed.
S&F for socket out let multipurpose flush type, 2 in 1 6 Pin 15 amps complete all as specified and directed.
S&F for Ceiling rose 3 terminal/pvc/polycarbonate, isolated body complete all as specified and directed.
S&F for PDC housing integrated LED flame proof highbay with 200 watt capacity luminaire with heat resistant toughened glass with IP 66 protection rating & T 6 temperature class compatible including necessary clamp and bolts with suitable size complete all as specified and directed..
M&L for sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed.
M&L for sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 2.5 sqmm size drawn in and including non metallic rigid PVC conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 2.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed.
S&F in renewal sheet metal enclosure double door distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incomer, 125 Amp,4 pole & Including MCCB 125 amps 4 pole 16 KA complete. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F for MCB DB, sheet metal enclosures double door SPN 8 way with bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
S&F for MCB SPN 32 Amps to 40 Amps, 240 volts 'C' series 16 KA including connection with suitable size copper lugs complete all as specified and directed.
S&F for MCB SP 240 volts, 6 to 32 Amps, 'C' series 10 KA including connection with suitable size copper lugs complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
M&L for Point wiring with PVC insulated 1.5 sqmm multi stranded FRLS copper conductor cable 1100 volts grade drawn into and including concealed rigid nonmetallic PVC conduit medium grade not less than 20mm (ISI marked) with all conduit fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside) with 2.8 mm thick HYLAM brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators, etc and 1.5 sqmm multi strand copper conductor cable as continuous earthwire complete all as specified and directed for the following :-
One light point controlled by one switch.
For one Ceiling fan point controlled by one switch
One 3 pin socket outlet 5 Amps controlled with one switch on the same board.
One 3 pin socket outlet 5 Amp controlled by one switch on independent board.
All as per item No 94 here in before but with cable 2.5 sqmm (nominal area) multi stranded copper wire unsheathed for one 5 pin socket out let 5 amps on independent board including continuous earth wire PVC insulated 1.5 sqmm copper multistranded conductor connecting to common earth and earth dolly complete all as specified and directed.
S&F for Socket 2 in 1 5 pin 5 /15 Amps flush type complete all as specified and directed.
S&F for Lamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings non ISI Marked complete all as specified and directed.
S&F for LED Lamp 09/10 watt complete with 5 star rating luminous efficiency > 130 lm/watt complete all as specified and directed.
S&F for Decorative ultra slim round profile LED Tubelight fitting of LED with extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt,130lm/watt, 6500K fitting, incluing reqd length of 1.5 Sqmm PVC multistranded copper conductor ro electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed.
M&L for sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 4 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 4 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. (NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface.
S & F for security light fittings better optics for uniform distribution IP 65 protection LED of 130 lm/watt ,30 watt, Heat resistance glass, pressure die cast aluminium housing including 25mm dia galvanised iron pipe light grade bracket bent to shape over all length 0.60mtr fixed to wall with 02 Nos FI clamps made of flat iron of size 40 x 6 mm alongwith 15 cm long, 8 mm dia bolts and nuts with washers grouted in wall complete including reqd length of 1.5 Sqmm PVC multistranded copper conductor for connection from ceiling rose to light fittings incl testing on completion all as specified and directed.
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size) in steel body complete all as specified and directed.
Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and directed.
S&F for MCB SPN 40 to 63 Amps, 240 volts 'C' series 16 KA including connection with suitable size copper lugs complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using manual method and necessary machine including HDPE pipe of 50 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete all as specified and directed.
Supplying and laying un reinforced precast concrete cable cover Class LV, Type I, flat size 250mm x 150mm x 40mm complete all as specified and directed.
S&F for tube 'Light' grade galvanised with all fitting laid in trenches, fixed to wall and floor of 50 mm dia for cable protection complete all as specified and directed.
M/s NILAY ENGINEERS
M/s Subhash Construction Co.
M/s Tirupati construction
M/S SANJAY AGARWAL
BHAGIRATH CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .