Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L1 | Accepted-AOC Offered lowest rate | |
| 2 | L2₹16.0 L+₹27,575.26 (1.76%)Rejected-Finance 18 DHRUBESH CHATTERJEE LANE UTTARPARA HOOGHLY 712258 | UTTARPARA | HOOGHLY | WEST BENGAL | 712258 | L2 | Rejected-Finance Higher than L1. | |
| 3 | L3₹16.1 L+₹43,350.98 (2.76%)Rejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | L3 | Rejected-Finance Higher than L1. |
Tender Value
Refer Docs
EMD Value
₹32,500
Closing Date
14 Jul 2021, 2:30 pmClosed
EXECUTIVE_ENGINEER_MALDA_MECHANICAL_DIVISION_PHEDD
Office of the Executive Engineer, Malda Mechanical Division, PHE Dte. Doulatpur PHE complex, P.O. Maliha, Dist. Malda, PIN 732102
Providing Pre Gaseous Chlorination arrangement at Dariapur water treatment plant under Southern Sector of Malda Arsenic Area Water Supply scheme in the district of Malda under MLMD, PHE Dte.
2021_PHED_333879_2
WBPHED/EE/MLMD/NIeT_05 of 2021-2022
Open Tender
Electrical Work/ Equipment
Item Rate
30 days
Doulatpur PHE complex, P.O. Maliha, Dist. Malda
Please refer Tender documents.
4 documents required · 4 mandatory
₹32,500
Yes
27 Jan 2023
28 Jun 2021
16 Jul 2021
28 Jun 2021
14 Jul 2021
28 Jun 2021
Amount
Supply & delivery of gaseous chlorination spares at site 0-5Kg/hr. capacity of Capco water solution make. As follows :-- A) Super™ Series 200 Vacuum Regulator Capacity: 05 Kg/hr…………. 2 Nos. B) Ejector Assembly, Capacity: 5 kg/hr. …. 2 Nos C) 3/8" Vacuum tubing. ………. 12 mtrs D) 3/8" Vent tubing ………. 12 mtrs E) Flexible copper coil …………. 2 Nos. F) Isolation Valve for Header Line ……. 2 Nos. G) 15 mm NB-CS Sch-80 ASTMA 106 Grade B Chlorine Gas Pipe ………. 12 mtrs H) Liquid Trap with out pressure gauge …. 2 Nos. I) 1-1/2" PVC solution Line ………. 12 mtrs J) 1-1/2" Ball Valve on solution line …… 2 Nos. K) Booster Pump Set Coupled with adequate HP 3 phase electric motor ……… 2 sets L) 1-1/4" PVC Water Line ……...... 12 mtrs M) Pressure Indicator with isolation line on water line ……………. 2 nos. N) 1-1/4" 'Y' type strainer on water line....2 nos. O) 1-1/4" Ball valve on water line ……. 4 nos. P) 1-1/4" Non return valve on water line....2 nos. Q) 1-1/2" PVC diffuser tube ……. 1 no. R) Local Control Panel ……. 1 no.
TC & GC to be submitted at the time of delivery of materials. (Make and drawing to be approved from EIC before placement of order)
Installation the all component as described in Sl. No. 1.00 as per technical specification at existing position part by part including supply of all erection materials providing dosing point on the rising main by making required size of hole clamping the dosing unit by expert mechanic and also making plat form with civil work for installation the booster pump in existing position including drawing of power line to booster pumps with necessary earthing as per IE rules and commissioning the entire system for leak proof operation of the gaseous chlorination plant as per direction of EIC.
MAKE AS PER DEPARTMENTAL APPROVED VENDOR LIST CIRCULATED VIDE MEMO NO.PHE/IV/2277/W-181/19 DATED- 25/09/2019
Add GST @ 12%
Add Cess @ 1%
R.N.S.TRADING
WEST BENGAL ENGINEERING CO.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .