| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC OPPOSITE MERCEDES SHOWROOM NALAPARA BIHARBARI GUWAHATI 781029 ASSAM | RI BHOI | MEGHALAYA | 781029 | L1 | Accepted-AOC Lowest Biddder | |
| 2 | L2₹27.1 L+₹5.4 L (25.1%)Rejected-Finance MOHANPUR PT LL HOUSE NO 00 CITY TOWN SILCHAR P O KATIRAIL P S KATIGORAH DISTRICT CACHAR PIN 788804 | CACHAR | ASSAM | 788804 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹28.2 L+₹6.6 L (30.3%)Rejected-Finance H NO 18 BY LANE NO 09 SATGAON PRAGATI NAGAR GUWAHATI ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹28.3 L+₹6.6 L (30.7%)Rejected-Finance OIL INDIA LTD GATE NO 02 PO UDAYAN VIHAR GUWAHATI ASSAM | KAMRUP METRO | ASSAM | 781001 | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹25.6 L
EMD Value
₹51,300
Closing Date
26 Jun 2023, 6:00 pmClosed
GE Narangi
GE Narangi C/o 99 APO
PROVN OF PERMANENT RETAINING WALL FOR EXISTING DITCH 60 X GEYSER 25 LTR AND EXHAUST FAN UNDER GE NARANGI
2023_MES_599722_1
8882/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE Narangi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Narangi
₹51,300
Yes
11 Aug 2023
31 May 2023
28 Jun 2023
31 May 2023
26 Jun 2023
13 Jun 2023
Amount
M&L Excavating over areas not exceeding 1.5 metre deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each in soft / loose soil etc complete all as specified and as directed.
Removing of surplus excavated material not exc 50m and depositing where directed at a level n. exc 1.5 m above the starting point etc complete all as specified and as directed.
M & L for plain cement concrete 1:4:8, type D2, (using 40 mm grade stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed.
M & L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate ) as in copping and the like including weathering slightly rounded /chamfered angles bed plates etc of man holes including necessary form work complete all as specified and as directed.
M&L Walling of random rubble masonry ,uncoursed, well bonded, bedded and solidly hearted and brought upto course built in CM 1:6 complete all as specified and as directed. bonded, bedded solidly hearted, built in ®PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) in foundation filliing and mass concrete complete all as specified and as directed.
M&L flush pointing to random rubble masonry wall in CM 1:3 complete all as specified and as directed.
S & F 75 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and laid in trenches or in floor as in waste / soil pipe complete all as specified and as directed
S & F GI Water tubing 15 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Cutting existing steel tubing 15 mm dia for additions /insertion now tees/elbows by screwing exsiting pipe for complete all as specified and directed.
S&F bib taps 15mm dia, cast copper alloy, chromium plated, fancy type with crutch or butter-fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S&F stop valves/ angular stop valve, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and directed.
M&L for point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in concealed/surface conduit including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one 5 Amps switch one way complete all as specified and directed.
M&L for point wiring with 2.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 2.5 Sqmm cable (including connecting to earth dolly) laid/fixed in and including surface casing caping on walls/ceiling, and also including sunk type PVC terminal box and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan point controlled by one number one way 15 Amp switch complete all as specified and as directed.
S & F switch, Piano type, 5 Amp, 240 Volts single pole one way (ISI marked) complete all as specified and as directed.
S & F ceiling rose surface bakelite 65x50mm three terminal complete all as specified and as directed..
S & F switch socket combination, 5 in 1, 5A / 16A amp flush type complete all as specified and as directed.
S & F MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia non metallic PVC grey conduit conforming to IS-9537 with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including conduit any type and size complete all as specified and as directed. Note : Three runs of cable and one run of PVC conduit will be measured as one Rm unit.
S&F of Exhaust fans AC single phase 230/ 240 V ,50 Hz metallic heavy body of size 300 mm sweep, 1400 RPM with louver fixing with 4 no hold fastener nut and bolt with washer and connecting with flexiable PVC insulated multistranded copper conductor cable of size 1.5 sqmm including civil work opening on wall of suitable size and 400 X 400 X 6 mm thick BWR graded plywood making suitable hole for fixing stainless steel wire cloth 0.36 mm nominal dia of wire and making good surface complete all as specified and directed.
Supply, fixing and testing of vertical wall mounted Storage type electric water heater of capacity 25 ltrs with BEE 5 star rated, 230 V, maximum power consumption 2 KW, Drypowder Fero Glass coating Technology for inner container with Heavy Duty seamless Incoloy 800 Glass lined heating element, and 2 Nos PVC connecting pipe of whirl technology 15 mm bore 450mm long for hot and cold water supply complete with all accesories and complete all as specified and directed. Note; The contractor shall submit two years warranty on product, seven years warranty on inner container and four years warranty on heating element.
M/S Bharat Construction
SHANKAR ENTERPRISE
S. R. TRADING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .