| Sl No | Description | Qty | Unit | M/S Sonu Traders L2 | GS Engineers L1 |
|---|---|---|---|---|---|
| 1.00 | Servicing of solar water heating plant capacity upto 1500 Ltr capacity at site complete, opening of all tubes descaling and replacing broken/ u/s panel , fixing float valve of suitable size ,making good surface and fixing in original position, opening of water heating tank cleaning, replacing heating element of 3 x 3KW as per existing model/size and making leak proof and testing to the entire satisfaction of Engr-in-Charge. | 3 | Each Job | 18,500 ₹55,500 | 2,000 ₹6,000 |
| 2.00 | S&F in replacement heating element with capacity 3/4 KW suitable or as per site requirement for upto 1500 Ltr capacity solar water heating plant, complete all as specified and directed by Engineer-in-charge. | 10 | Each | 1,500 ₹15,000 | 2,000 ₹20,000 |
| 3.00 | M&L for MS pipe 40mm dia connecting, welding , smoothing and making leak proof and including insulation with puff slab 30mm thick with wire mesh to bound the puff and including applying CRPX compound and cladding with 24 gauge aluminium super quality sheet including clamping/ binding material as per site requirement/directed and testing entire work to be carried out providing material strictly of existing specifications and to the entire satisfaction of Engineer-in Charge, including dismantling of old MS pipe, complete all as specified and directed by Engr-in-Charge. | 25 | RM | 1,250 ₹31,250 | 300 ₹7,500 |
| 4.00 | Taking down existing old unserviceable puf insulation from MS pipe and M&L for insulation over a existing MS pipe of size upto 80mm dia with puff slab 30mm thick with wire mesh to bound the puff and including applying CRPX compound and cladding with 24 guage alluminium super quility sheet including clamping/ binding material, testing as per site requirment and directed by Engr-in-charge. | 3 | kg | 1,500 ₹4,500 | 500 ₹1,500 |
| 5.00 | Taking down and servicing of ceiling fan 1200/1400 mm sweep at site and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt/ washer, rubber real bush, canopy alongwith all suitable items as per site requirment and reassembling the fan complete and hanging on its original/ new position as directed by Engr-in-charge.
Note: MS nut bolts with split pin, Ball bearing and Gun metal bush will be paid and measured seperately. | 125 | Each Job | 50 ₹6,250 | 130 ₹16,250 |
| 6.00 | Taking down and servicing of BLDC ceiling fan 1200/1400 mm sweep at site and removing of damaged / old parts i.e electronic parts, rotor, stator , shaft including all damaged parts of BLDC Fan and re-filling new grease including replacement of parts i.e electronic parts, rotar, stator , copper winding shaft including all damaged parts of BLDC Fan as per site requirment and reassembling the fan complete and hanging on its original/ new position as directed by Engr-in-charge. | 200 | Each Job | 650 ₹1.3 L | 200 ₹40,000 |
| 7.00 | Taking down and servicing / cleaning of exhaust fan 230 to 450 mm sweep at site and removing of old grease from bearing of exhaust fan and re-filling new grease including replacement of worn out nut bolt, rubber real bush, gun metal ball bearing, capacitor, split pin alongwith all suitable items as per site requirment etc and reassembling the fan complete and hanging on its original/ new position as directed by Engr-in-charge. | 150 | Each Job | 100 ₹15,000 | 150 ₹22,500 |
| 8.00 | Supply only MS Nut bolts with split pin as per sample for hanging of any capacity of Ceiling Fans and as directed by Engineer-in-Charge. | 100 | Each | 40 ₹4,000 | 15 ₹1,500 |
| 9.00 | Supply only Ball bearing , Rubber shackel suitable size of ceiling fan / pedastal and exhaust-fan of any type and size, complete all as specified and directed by Engineer-in-charge. | 200 | Each | 70 ₹14,000 | 80 ₹16,000 |
| 10.00 | Supply only gun metal clamp with bush suitable for ceiling fan of any type and size including removing old one, complete all as specified and directed by Engineer-in-charge. | 100 | Each | 25 ₹2,500 | 30 ₹3,000 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
22 Nov 2025, 6:00 pmClosed
AGE(I) DAPPAR
AGE(I) DAPPAR
REPAIR AND MAINT OF SUMMER APPLIANCE AND CONNECTED EQUIPMENT AT MIL STN DAPPAR UNDER AGE (I) DAPPAR
2025_MES_733024_2
CA No AGE(I)/DPR/T-19/2025-26
Open Tender
Civil Works
270 days
AGE (I) DAPPAR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE(I) DAPPAR
₹30,000
Yes
8 Jan 2026
3 Nov 2025
24 Nov 2025
3 Nov 2025
22 Nov 2025
10 Nov 2025
Amount
Servicing of solar water heating plant capacity upto 1500 Ltr capacity at site complete, opening of all tubes descaling and replacing broken/ u/s panel , fixing float valve of suitable size ,making good surface and fixing in original position, opening of water heating tank cleaning, replacing heating element of 3 x 3KW as per existing model/size and making leak proof and testing to the entire satisfaction of Engr-in-Charge.
S&F in replacement heating element with capacity 3/4 KW suitable or as per site requirement for upto 1500 Ltr capacity solar water heating plant, complete all as specified and directed by Engineer-in-charge.
M&L for MS pipe 40mm dia connecting, welding , smoothing and making leak proof and including insulation with puff slab 30mm thick with wire mesh to bound the puff and including applying CRPX compound and cladding with 24 gauge aluminium super quality sheet including clamping/ binding material as per site requirement/directed and testing entire work to be carried out providing material strictly of existing specifications and to the entire satisfaction of Engineer-in Charge, including dismantling of old MS pipe, complete all as specified and directed by Engr-in-Charge.
Taking down existing old unserviceable puf insulation from MS pipe and M&L for insulation over a existing MS pipe of size upto 80mm dia with puff slab 30mm thick with wire mesh to bound the puff and including applying CRPX compound and cladding with 24 guage alluminium super quility sheet including clamping/ binding material, testing as per site requirment and directed by Engr-in-charge.
Taking down and servicing of ceiling fan 1200/1400 mm sweep at site and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt/ washer, rubber real bush, canopy alongwith all suitable items as per site requirment and reassembling the fan complete and hanging on its original/ new position as directed by Engr-in-charge. Note: MS nut bolts with split pin, Ball bearing and Gun metal bush will be paid and measured seperately.
Taking down and servicing of BLDC ceiling fan 1200/1400 mm sweep at site and removing of damaged / old parts i.e electronic parts, rotor, stator , shaft including all damaged parts of BLDC Fan and re-filling new grease including replacement of parts i.e electronic parts, rotar, stator , copper winding shaft including all damaged parts of BLDC Fan as per site requirment and reassembling the fan complete and hanging on its original/ new position as directed by Engr-in-charge.
Taking down and servicing / cleaning of exhaust fan 230 to 450 mm sweep at site and removing of old grease from bearing of exhaust fan and re-filling new grease including replacement of worn out nut bolt, rubber real bush, gun metal ball bearing, capacitor, split pin alongwith all suitable items as per site requirment etc and reassembling the fan complete and hanging on its original/ new position as directed by Engr-in-charge.
Supply only MS Nut bolts with split pin as per sample for hanging of any capacity of Ceiling Fans and as directed by Engineer-in-Charge.
Supply only Ball bearing , Rubber shackel suitable size of ceiling fan / pedastal and exhaust-fan of any type and size, complete all as specified and directed by Engineer-in-charge.
Supply only gun metal clamp with bush suitable for ceiling fan of any type and size including removing old one, complete all as specified and directed by Engineer-in-charge.
Taking down and opening the body cover of ceiling fan any type and make and cutting the existing worn out winding with out damaging the stator removing the coil insulation and putting new insulation of polyster paper, winding with super enameled copper wire of suitable gauge with correct number of turns of auxillary and main winding and varnishing and baking complete including soldering new lead of copper wire testing complete including transportation to work shop and back, complete all as specified and directed by Engineer-in-charge.
Ceiling fans 1200/1400 mm sweep
Exhaust fan Upto 230 to 300mm sweep
Wall mounted fan 400mm sweep
M&L in replacement of Exhaust fan louvers metal body of suitable for 250 to 350 mm sweep exhaust fan fix at a its existing position, complete all as specified and as directed by Engineer-in-charge.
M&L in replacement of Exhaust fan louvers metal body of suitable for 450 mm sweep exhaust fan fix at a its existing positiomn, complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of unserviceable capacitor 4/ 5 MFD or as per the site requirement, complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of unserviceable capacitor 2.5 / 3.15 MFD or as per the site requirement, complete all as specified and as directed by Engineer-in-charge.
M&L for painting one coat after cleaning all dust painting with MES NO /SM NO on fans etc to ceiling fan complete, with synthetic enamel paint by spray painting including filling cavities with filler, and hanging at original locations, complete all as specified and directed by Engineer-in-charge.
S&F in replacement M.S rod of length of 1.5 and suitable dia including clamp , nut & split pin suitable for 1200/1400 /1500mm sweep fan, complete all as specified and directed by Engineer-in-charge.
S&F in replacement fan blade set suitable for Exhaust fan 300 to 450 mm sweep, complete all as specified and directed by Engineer-in-charge.
Taking down desert cooler of any make & size at different site / location and carrying out necessary repairs as to stop leakage and replacement of rusted nuts bolts ,washers etc and scrapping of old paint and removing scales from internal & external surfaces top and bottom complete and providing two coats of synthetic enamel (hammer tone) paint by spray machine over one coat of red oxide primer including writing of MES/SM NO in 3 cm height and re fixing in existing position after greasing ,oiling and servicing of fan motors pumps and making good and serviceable condition, complete all as specified and directed by Engineer-in -Charge.
M&L for rewinding to desert cooler motor of 450/500 mm sweep winded with winding machine with super enamelled copper winding wire of existing size gauge & design including insulated sleeves , paper , varnishing with ‘B’ class insulation varnish, thimbles, connection with flexible cable of copper conductor of size 23/.0076 up to connector block complete all as specified and directed by Engineer-in-charge. the above shall be done at the MES store yard.
S&F in replacement desert cooler fan motor of copper winding of capacity 200W, 1300 RPM 50HZ 240 Volts, winding material- Copper, single phase, 500 mm sweep as per existing suitable size , and approved make, complete all as specified and directed by Engineer-in-charge.
S&F in replacement pump 18 watt or as per suitable site condition , 220 volts AC electric driven suitable for 4 meter head, complete all as specified and directed by Engineer-in-charge.
S&F in replacement dusty/worn out wool/grass pad (set of 3 nos) complete all as specified and directed by Engineer-in-charge.
S&F in replacement Honey bee pad (set of 3 nos) synthetic, complete all as specified and directed by Engineer-in-charge.
S&F in replacement polyethylene pipe of 15mm bore high density of existing specifications, complete all as specified and directed by Engineer-in-charge.
S&F in replacement PVC elbow (Set of three) and tee (One) right angle of existing specifications, complete all as specified and directed by Engineer-in -Charge.
S&F in replacement PVC top plug 3 pin 5Amp 230 Volts, complete all as specified and directed by Engineer-in -Charge.
S&F in replacement flexible copper conductor size 23/0.0076 3 core PVC insulated sheet, complete all as specified and directed by Engineer-in -Charge.
S&F in replacement of capacitor 4 mfd 230 Volts (+-) 5 % or suitable size as per the site requirement dry type complete suitable for desert cooler, complete all as specified and directed by Engineer-in -Charge.
Taking out of unserviceable MS part body of any capacity including existing fan, motor, blades, water lifting pump and electric wiring, fitting switches etc, complete all as specified and directed by Engineer-in –Charge
S&F fan blade of suitable size and make for desert cooler, complete all as specified and directed by Engineer-in-charge
S&F metallic frame with set of 4 legs as per model suitable for fixing/mounting fan motor of desert cooler with nuts, bolts, rubber etc., complete all as specified and directed.
Disconnecting to unserviceable sealed compressor of 1.5/2 Ton capacity window type AC and M& L replaced with new company sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system & testing the leaking with gas charging all as per site requirment etc, complete all as specified and directed by Engineer-in-charge.
Disconnecting to unserviceable sealed compressor of 1.5/2 Ton capacity split type AC and M& L replaced with new company sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system & testing the leaking with gas charging all as per site requirment etc, complete all as specified and directed by Engineer-in-charge.
M&L recharging of gas R-22 or as per site requirments in air conditioner unit window type and split type 1.5/2 ton complete including testing of leakage and testing for satisfactory performance, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement thermostat switch suitable for existing capacity of window and split type AC (1.5/2 Ton capacity), complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement starting capacitor upto 100 mfd suitable or as per site requirments for window/split type AC of any capacity, complete all as specified and as directed by Engineer-in-Charge.
S&F replacement running capacitor 36 MFD suitable or as per site requirment for window/ split type AC of any capacity, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement over load protector suitable as per site requirment for split/window type AC 1.5/2 ton capacity, complete all as specified and directed by Engineer-in-Charge.
Supply only front grill of window/split type AC with shutters as per existing model/capacity, complete all specified and directed by Engineer-in-Charge.
Supply only 1/2'' and 1/4'' reverse valve for window / split AC valve as per existing model/capacity, complete all as specified and directed by Engineer-in-Charge.
Supply only suction valve size 3/8'' for 1.5/2 TR window/split AC or as per existing model / capacity, complete all as specified and directed by Engineer-in-Charge.
Supply only delivery valve size 1/2'' for 1.5/2 TR window / split AC or as per existing model / capacity complete all as specified and directed by Engineer-in-Charge.
Supply only swing motor for 1.5/2 TR window / split AC indoor unit for any existing make, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of fan motor for split type Air Conditioner of capacity 1.5/2.0 ton as per existing model of approved all as per directed by Engr-in-Charge.
S&F in replacement of rolling type PVC blower for indoor unit of split AC 1.5 / 2.0 ton capacity make as per existing make model, complete all as specified and directed by Engineer-in-Charge.
S&F fan blade for out door unit of split AC 1.5 /2.0 Ton Capacity make as per existing size & model, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PCB assembly of existing make for window/split type ACs 1.5 to 2.0 ton any type, complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of fan blade of existing size / model of window Acs, complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of drain pipe for AC any type of existing size/model of window Acs, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement new fan motor of existing size / model of Window AC, complete all as specified and directed by Engineer-in-Charge.
Supply only remote control hand set for existing capacity / model of Window type/ split type air conditioner with requred pencil cells as per sample, complete all as specified and directed.
Supply and replacement of copper pipe heavy duty of size 5/8" complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of copper pipe heavy duty of size 3/8" complete all as specified and directed by Engineer-in-Charge.
S&F pipe insulation for copper pipe of size 5/8" and 3/8" complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out worn out/unserviceable sealed compressor of water cooler of capacity 40/80/120 ltrs and M& L replacing with new sealed compressor of existing capacity and size including soldering of suction and discharge line gas pipe and flushing the complete system and making leak proof, complete all as specified and directed by Engineer-in-Charge.
Cleaning the system with CRC and charging the refrigerant gas as per site requirment (R-22/M22) including replacement of strainer filter suitable for water cooler of 40/80/120 litres capacity, complete all as specified and directed by Engineer-in-charge.
S&F in replacement Starting relay assembly suitable for water cooler of 40/80/120 ltr capacity, complete all as specified and directed by Engineer-in-Charge.
M&L internal wiring for water coolers 40/80/120 ltr capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers etc required for fastening with body etc, complete all as specified and directed by Engineer-in-charge.
S&F in replacement starting capacitor suitable as per site requirment (40-60 mfd) assembly for water cooler, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement running capacitor 10 mfd assembly or as per site requirment for water cooler, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement over load protector for water cooler suitable, complete all as specified and directed by Engineer-in-Charge
S&F in replacement drain hose pipe 40mm dia suitable for water cooler of 40/80/120 liter capacity, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement clamp for fan motor of 1/16 to 1/32 hp hose pipe of water cooler, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement fan blade plastic for fan motor 1/32 hp for water cooler, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement clamp for hose pipe, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement fan motor with new one suitable for water cooler of capacity 40/80/120 ltrs, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement self closing tap push type 15 mm bore of cast copper alloy chromium plated fixed to water cooler as in repair, complete all as specified and directed by Engineer-in-Charge.
Dismantling of unsv float valve assy and S&F PVC float valves complete assy 15 mm size or as per the site requiremenrt, complete all as specified and directed by Engr-in-Charge.
S&F in replacement thermo-stat switch with new one complete for water cooler, complete all as specified and directed by Engineer-in-Charge.
S&F in renewal, condensing coil for water cooler capacity 40/80/120 Litres of existing make of 22 Gauge MS sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
M&L for detecting any leakage from cooling and condensing coil fin of water cooler any capacity of any make with the help of high pressure nitrogen gas and repairing the leakage by welding/brazing of cooling and condensing coils by disconnecting inclusing renewal of new filter, new capillary tube and testing the unit, complete all as specified and directed by Engineer-in-Charge.
Disconnecting to unserviceable sealed compressor for upto 310 ltr capacity of refrigerator and M&L replaced with new company sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system arresting the leaking etc, complete all as specified and directed by Engineer-in-charge.
M&L cleaning the system with CRC and charging the refrigerant gas R-134 or as per site requirment , including replacing strainer and rectification of leakage in the system from refrigerator upto 310 litres capacity, complete all as specified and directed by Engineer-in-charge.
S&F in replacement starting relay assembly suitable for refrigerator upto 310 litres capacity, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement starting capacitor of suitable size or 40-60 mfd assembly suitable for refrigerator upto 310 litres capacity, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement over load protector suitable for refrigerator upto 310 litres capacity, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement thermo-stat switch suitable for refrigerator any capacity, complete all as specified and as directed by Engineer-in-Charge.
S&F timer for refrigerator of capacity upto 310 Ltrs or existing size, complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of fan motor of freezer of refrigerator upto 310 ltr existing size, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement heating element with capacity 2KW suitable for existing make / model of geyser 50ltrs capacity, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement heating element with capacity 1KW suitable for existing make / model of geyser 25ltrs, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement thermostat suitable for existing make / model of geysers 25 to 50 Ltrs, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement pressure release valve of existing specification & make for geysers of cap 25 to 50 Ltrs, complete all as specified and directed by Engineer-in-Charge.
Preparation surface for painting and painting of geysers cap 25/50Ltrs with 2 coats of synthetic enamel painting with MES NO /SM NO in situ, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement gun metal non return valve size of 15 mm of existing make for geysers of cap 25 / 50 Ltr, complete all as specified and directed by Engineer-in-Charge.
S&F in PVC connection pipe with male female sockets length as per site requirment long for geyser 25/50 ltrs capacity, complete all as specified and directed by Engineer-in-charge.
S&F in replacement sheet metal enclosure with socket plug top and MCB SPN cap 32 Amps with a 2 pin, earth plug and socket, complete all as specified and directed by Engineer-in-Charge.
Dismaintling of voltage stablizer and M&L various components of automatic voltage corrector of any rating but cap not exceeding 5 KVA, single phase , 50 Hz including locating the faults, complete all as specified and directed by Engineer-in-Charge.
Dismaintling of burnt unserviceable main transformer copper wound and stamping and M&L for re-assembling the stemping and re-winding of main transformer, single phase, 50 Hz with super enamelled copper winding wire of existing size, design & weight SWG turns / tapping and varnishing complete of voltage stablizer cap up to 5 KVA, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement voltage regulator PCB for voltage stabliser for power rating upto 5KVA, complete all as specified and directed by Engr -in-Charge.
Disconnecting to unserviceable sealed compressor of deep freezer of capacity 300 - 350 Ltrs and M&L replaced with New sealed compressor of existing capacity & model including soldering of liquid /gas pipeline,cleaning the system arresting the leaking etc, complete all as specified and directed by Engineer-in-charge.
M&L cleaning the system with CRC and charging the refrigerant gas R-134 or as per site requirment including replacing strainer and rectification of leakage in the system from deep freezer of 300-350 litres capacity, complete all as specified and as directed by Engineer-in-charge.
M&L for Cleaning to internal surfaces of deep freezer of 300-350 litres capacity suitable repairs to body to stop leakage etc, replacing unserviceable nuts bolts & washers etc including preparation of external surfaces of body and painted with anticorrosive synthetic enamel paint with help of spray gun machine over a coat of red oxide and writing SM / MES No in 3cm height, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement starting relay assembly suitable for deep freezer of 300-350 litres capacity, complete all as specified and as directed by Engineer-in-Charge.
M&L internal wiring for deep freezer of 300-350 litres capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers etc required for fastening with body etc, complete all as specified and as directed by Engineer-in-charge.
S&F in replacement starting capacitor 40-100 mfd assembly or as per the site requirment suitable for deep freezer of 300-350 litres capacity, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement running capacitor 10-20 mfd or as per the site requirement suitable for deep freezer of 300-350 litres capacity, complete all as specified and as directed by Engineer-in-charge.
S&F in replacement over load protector suitable for deep freezer of 300 -350 litres capacity, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement drain hose pipe suitable size / dia with suitable clamp for deep freezer of 300 -350 litres capacity, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement fan blade plastic for fan moter 1/32 hp suitable for fan blade plastic for fan moter 1/32 hp deep freezer of 300 - 350 litres capacity, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement fan motor suitable for deep freezer of 300 - 350 litres capacity with suitable clamp, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement condensor coil suitable for deep freezer of 300 - 350 litres capacity, complete all as specified and as directed by Engineer-in-charge.
S&F in replacement thermostat switch with new thermostat switch suitable for deep freezer any capacity, complete all as specified and as directed by Engineer-in-charge.
S&F in replacement MCB SP 6 -32 Amps,10 KA, 'C' series 240 V ISI marked, complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB SPN 06-32 Amps,10 KA 'C' series 240 V ISI marked, complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB TPN 63 Amps,10 KA 'C' series 240 V ISI marked, complete all as specified and directed by Engineer-in-charge.
M/S Sonu Traders (BID ID -3471380)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.73 MB
Tender19.pdf
Tender Documents • 0.98 MB
BOQ_826582.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid