Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹3.3 L
Closing Date
27 Aug 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
15 conditions · 2 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: (a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows:
The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract, with prior approval of Chief Engineer in writing. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.[Ref:- GCC April 2022 Para 10.1 of Tender Form (Second Sheet) of Annexure I of ITT. Further 'Explanation for Para 10 of the Tender Form (Second Sheet) including Para 10.1 to 10.5 - Eligibility Criteria' shall be as per GCC April 2022].
Defination of Similar Work :- Any work involving outdoor or Indoor signalling work. Signalling work-All works which are directly related to the interlocking of the core Signaling System. OR Any MACLS work involving outdoor & indoor work or alteration in existing Indoor/outdoor signaling system. OR Any work involving outdoor/indoor signalling works including MACLS/EI/PI/RRI/IBS/IBH/LC Gate/DAC/ELD and ELD for Signalling Cable, Quad Cable, Fuse Auto Changeover system etc.
48 conditions · 1 needing a document upload
The bidder has to submit the Annexures attached with tender:- I/A,I/B,II, III,IV/A,IV/B , tender first Sheet duly fill-up and signed (As applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Mode of Payment from Railway through a "Letter of Credit(LC)" arrangement. If yes, attach beneficiary Bank details. Details available in Special condition.
The Balance Sheet and all other Financial documents attested/certified by the Chartered Accountant (CA) to substantiate fulfilment of Financial Eligibility Criteria should be with UDIN failing which the offer shall be considered as incomplete and will be summarily rejected without any further reference.
(Special Condition of Contract for mandatory updating of Labour data on Railway's shramikkalyan portal by Contractor (Ref:- Railway Board letter no.-2018/CE-I/CT/4, Dated 17.10.2018.)
A. Contractor is to abide by the provisions of Payment of Wages act &Minimum Wages act in terms ofclause 54 and 55 of Indian Railway GeneralCondition of Contract. In order to ensure the same, anapplication has beendeveloped and hosted on websitewww.shramikkalyan.indianraihwars.gov.in'.Contractor shall register his firm/company etc. and uploadrequisite details oflabour and their payment in this portal. These details shall be available inpublicdomain. The Registration' updation of Portal shall be done as under:(a) Contractor shall apply for onetime registration of his company/firm etc. inthe Shramikkalyan portal with requisite details subsequent toissue of Letter ofacceptance. Engineer shall approve the contractor's registration within 7 daysof receiptof such request. (b)Contractor once approved by any Engineer, cancreate password with login ID (PANNo.) for subsequent use of portal for allLOAs issued in his favour. (c) The contractor once registered onthe portal,shall provide details of his Letter of Acceptances (LOA)/Contract Agreementson shranikkalyanportal within 15 days of issue of any LOA For approval ofconcerned engineer. Engineer shall update (ifrequired) and approve thedetails of LOA filled by contractor within 7 days of receipt of such request.(d)After approval of LOA by Engineer, contractor shall fill the salient details ofcontract laboures engagedin the contract and ensure updating of each wagepayment to them on shramikkalyan portal on monthlybasis. (e) It shall bemandatory upon the contractor to ensure correct and promt uploading of allsalientdetails of engaged contractual labour & payment made thereof aftereach wage period. B. Whileprocessing payment of any 'ON account bill' or'Final bill' or relese of 'Advance ' or 'PerformanceGuarantee/Security deposit' contractor shall submit a certificate to the Engineer orEngineer'srepresentative that " I have uploaded the correct details of contract laboursengaged inconnection with this contract and payment made to them during the wage period in Railway'sShramikkalan portal at www.shramikkalyan.indianrailways.gov.in till _____, month,______ Year.".
Special Conditions for inclusion of 'Letter of Credit' as Mode of Payment in works Tender or Service tender. (Authority: - Railway Bd. letter no.2018/CE-I/CT/9, dated: 04.06.2018).
For all the tenders having advertised cost of Rs.10 lakh or above, the contractor shall have the option to take payment from Railways through a letter of credit (LC) arrangement.
This option of taking payment through LC arrangement has to be exercised in IREPS (Indian Railway Electronic Procurement System - the e-application on which tenders are called by Railways) by the tenderer at the time of bidding itself, and the tenderer shall affirm having read over and agreed to the terms and conditions of the LC option.
The option so exercised, shall be an integral part of the bidder's offer.
The above option of taking payment through LC arrangement, once exercised by tenderer at the time of bidding, shall be final and no change shall be permitted, thereafter, during execution of contract.
In case tenderer opts for payment through LC, following shall be the procedure to deal release of payment through LC:
The LC shall be a sight LC.
The contractor shall select his Advising/Negotiating bank for LC. The incidental cost towards issue of LC and its operation thereof shall be borne by the contractor.
SBI, New Delhi, Main Branch will be the nodal branch for issue of LCs based on online requests received from Railway Accounts Units for tenders opened in financial year 2018-19. SBI branches where the respective Railway Accounts Office has its Account (local SBI branch) will be the issuance/reimbursing branch for LC issued under this arrangement. The Bank shall remain same for this tender till completion of contract. The incidental cost @ 0.15% per annum of LC value, towards issue of LC and operation thereof shall be borne by the contractor and shall be recovered from his bills.
The LC shall be opened initially for duration of 180 to 365 days in consultation with contractor. The LC shall be extended time to time as per the progress of the contract, on the request of the contractor. The value of LC to be opened initially as well as extended thereafter shall be finalised by the engineer in consultation with the contractor on the basis of expected progress of work.
The LC terms and conditions shall inter-alia indemnify and save harmless the Railway from and against all losses, claims and demands of every nature and description brought or recovered against the Railways by reason of any act or omission of the contractor, his agents or employees, in relation to the Letter of Credit (LC). All sums payable/borne by Railways on this account shall be considered as reasonable compensation and paid by contractor.
The LC terms and conditions shall inter-alia provide that Railways will issue a Document of Authorisation (format enclosed as Annexure 2) after passing the bill for completed work, to enable contractor to claim the authorized amount from their bank.
The acceptable, agreed upon document for payments to be released under the LC shall be the Document of Authorisation.
The Document of Authorisation shall be issued by Railway Accounts Office against each bill passed by Railways.
On issuance of Document of Authorisation, a copy of Document of Authorisation shall be posted on IREPS for download by the contractor. A digitally signed copy of Document of Authorisation shall also be sent by Railway Accounts Office to Railway's bank (Local SBI Branch).
The contractor shall take print out of the Document of Authorisation available on IREPS and present his claim to his bank (advising Bank) for necessary payments as per LC terms and conditions. The claim shall comprise of copy of Document of Authorisation, Bill of Exchange and Bill.
3.5.11 The payment against LC shall be subject to verification from Railway's Bank (Local SBI Branch).
The contractor's bank (advising bank) shall submit the documents to the Railway's Bank (Local 3.5.12 SBI Branch).
The Railway's bank (issuing bank) shall, after verifying the claim so received w.r.t. the digitally 3.5.13 signed Document of Authorisation received from Railway Accounts Office, release the payment to contractor's bank (advising bank) for crediting the same to contractor's account.
Any number of bills can be dealt within one L.C, provided the sum total of payments to contractor is within the amount for which LC has been opened.
The LC shall be closed after the release of final payment including PVC amount, if any, to the 3.5.15 contractor.
The release of performance guarantee or security deposit shall be dealt directly by railway with the contractor i.e., not through LC.
Payment Terms:
For Purely Supply Items:-90% of the value of each Supply Item of Schedule of Works will be Paid after supply of Items and on production of the following documents: - (i) Receipt of Material at Consignee's depot. (ii) Original inspection certificate / waiver of inspection issued by Inspecting Officer.(iii)Manufacturers' inspection certificate that the materials are in accordance with the specifications of the contract. Invoice in duplicate. A certificate that the materials supplied are as per the contract and the amount claimed in the invoice is correct as per terms of the contract. (vi) (a) Store receipt certificate issued by Railway official/Representative as per format as Annexure - R of existing Tender document(Copy enclosed). 5% percent payment for purely Supply Items against tender schedule of works will be made after successful commissioning of the Station. (b) The balance 5% percent payment for purely Supply Items against tender schedule of works will be made after Completion of Work, with Final Bill of the Contract.
For Purely Execution/Installation items: - 90% of the value of each Purely Installation Item of Schedule of Works will be paid after Installation & Testing of the Item. (a)5% percent payment for Purely Execution /Installation items against tender schedule of works will be made after successful commissioning of the station. (b)The balance 5% percent payment for purely Execution /Installation Items against tender schedule of works will be made after successful commissioning of the Station. Note: In case commissioning of station is delayed by more than 06 months on Railway Account and the physical work has been completed by the contractor in totality then 5% payment on account of commissioning of the station shall be released to the contractor.
For Supply & Installation items: - 90% percent payment for Supply &installation Items against tender schedule of works will be made after successful installation & testing and on production of the documents mentioned above in Para 1. on account bill shall be paid only on production of certificate by the site Engineer that relevant portion of installation has been completed. (a) 5% percent payment for Supply &Installation Items against tender schedule of works will be made after successful commissioning of the Station. (b)The balance 5%percent payment for supply & installation items against tender schedule of works will be made after completion of work with final bill of the contract.
All payments shall be made on the certificate of the Engineer within a reasonable time of the submission of the necessary bills by the contractor. Payment shall be made through cheques/NEFT/RTGS/LC payment in the name of the Contractor.
Scope of Work(i) S&T Work: (i) S&T works in connection with Interlocking of 03 Nos. of L.C. Gate having TVU more than 20000 in SHC-PRNA section of Samastipur division . (ii) Proposed Site/Location for Execution of Work: LC No. 4 (PRNA-PRNC), 13 (KTNR-PRNC) & 92 (BYP-DMH), ECR, SPJ Division. Note: Railway reserves the right to change, alter, add, or delete any site/location based on operational requirements, feasibility, availability of site, site conditions, or any other reason deemed necessary. (iii) The latest specifications and amendments thereto shall apply to all drawings and specifications. (iv) Technical Specifications, Inspection, Terms and Conditions: The detailed technical specifications, inspection requirements, term, and conditions for execution and supply shall be as per the tender document and applicable technical specifications (as applicable). Inspection for each item are specified in the schedule. However, for any safety item requiring Third-Party Inspection (TPI) by RDSO/RITES, shall be supplied with such TPI inspection, irrespective of the inspection agency mentioned in the schedule. (Inspection-Consignee, subject to total item value < 05 Lakh, Non safety critical items). TPI (RITES) inspection charge to be borne by contractor. Note: All the materials (schedule items) shall be supplied as per railway requirement. There should be no any compatibility/suitability issues for supplied materials to the existing/New equipment. (v) The work shall be executed and materials supplied as per the instructions of the site engineer. (vi) The quantities/items indicated in the schedule may vary according to Railway or site requirements. Railway reserves the right to change, alter, add, or delete any item or quantity at any stage of the contract. Railway does not guarantee execution of work under every item or the quantities specified in the schedule. (vii)The rates quoted by the tenderer shall include the cost of materials and all incidental charges, including transportation, loading, unloading, handling, and any other associated expenses. The quoted rates shall also include all applicable taxes (including GST), duties, royalties, levies, octroi, and other statutory charges (as applicable). (viii) Recovery of taxes from bills shall be made as per the extant rules in force. (ix) The contractor shall be responsible for the carriage, safe transportation, loading, unloading, storage, protection, and safe handling of all materials required for the execution of the work. (x) All relevant standard guidelines and instructions issued by Railway Board,HQ/East Central Railway regarding contract management, technical aspects/requirements, execution of work, and prevailing Railway practices, E. C. railway practice inforce etc. shall be apply in this contract (as applicable).
Transportation of Materials:-
All materials specifically supplied by contractor to be supplied to the SSE/Signal or Tele/Store/SPJ or as specified by competent authority.
Contractor will carry all the materials (contractor supplied) from SSE/Signal or Tele/Store/SPJ or as specified by Competent authority to the site of work at his own cost and arrangement.
Execution of AMC:- Not applicable.
S&T works in connection with Interlocking of 03 Nos. of L.C. Gate having TVU more than 20000 in SHC-PRNA section of Samastipur division
SPJ-SnT-S-07-2026~ECR
SPJ-SnT-S-07-2026
Open
Works - General
12 Months
Samastipur, Bihar
₹0
₹3.3 L
27 Aug 2026
6 Aug 2026
13 Aug 2026
60 days
161 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,47,45,929.57 | ||
| — | 3.00 | — | — | ||
| "Supply, transportation, installation & commissioning electrically operated lifting barrier set as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest each consisting of 2 nos. of lifting barrier pedestals, each with min. 6 contact circuit controller with top roller type limit switches, hand crank, 2 electric motors, 110VAC of capacity suitable to operate barriers upto 32' long booms, 2 nos. of steel octagonal booms of 32' length with 2 nos. stop boards. Boom light boxes, ms counter weights and 2 nos. of boom support with suitable boom locking but without fringes along with control panel with buttons and indicating lamps, motor connectors and mcb to operate 2 barriers of 1 set. this includes supply and installation of gate hooter - 1 no. and horn ( 8 watt) - 1 no. with all fixing arrangements. All of the above items including supply of cement, civil work materials etc. shall be done by the contractor for commissioning. 230vac supply only shall be arranged by the railway in near by relay room.(Complete set )(i) Supply"(Insp:-RDSO) | — | — | — | 13,30,018.47 | |
| — | 3.00 | — | — | ||
| "Supply, transportation, installation & commissioning electrically operated lifting barrier set as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest each consisting of 2 nos. of lifting barrier pedestals, each with min. 6 contact circuit controller with top roller type limit switches, hand crank, 2 electric motors, 110VAC of capacity suitable to operate barriers upto 32' long booms, 2 nos. of steel octagonal booms of 32' length with 2 nos. stop boards. boom light boxes, MS counter weights and 2 nos. of boom support with suitable boom locking but without fringes along with control panel with buttons and indicating lamps, motor connectors and MCB to operate 2 barriers of 1 set. this includes supply and installation of gate hooter - 1 no. and horn( 8 watt) - 1 no. with all fixing arrangements . All of the above items including supply of cement, civil work materials etc. shall be done by the contractor for commissioning. 230vac supply only shall be arranged by the railway in near by relay room.(complete set )(ii) Execution" | — | — | — | 1,70,392.23 | |
| — | 3.00 | — | — | ||
| Supply of Sliding boom gate as per E.Rly signal workshop/HWH dwg no. BSA/29/ 730 BSA/29/731 & BSA/29/737. this includes supply of 8 nos. 'e' type lock with key as per irs spec. irs:S-30/64 with latest amendment . key lock e type as per drawing no. sa-3376/m with latest amendment, key for e type lock as per drawing no. 3377/m with latest amendment ward no. to be fixed on MS plate as mentioned in the drawing.(Insp:-RITES) | — | — | — | 8,04,887.34 | |
| — | 3.00 | — | — | ||
| "Installation & commissioning of sliding boom gate. This includes levelling , fixing of sliding boom with fixing of e type lock etc. note all materials except sliding boom gate to be supplied by the contractor.Installation" | — | — | — | 17,423.49 | |
| — | 3.00 | — | — | ||
| Casting concreting & curing of foundation (1:3:6) for sliding gate as per dwg. no. SGW-SDAH / sliding gate foundation / 2012 including supply & fixing of holding down bolts with washers and nuts , MS plates of size 350 mm x 350mm x 8 mm, cement etc. 10 foundations required in each set of gate | — | — | — | 1,97,317.17 | |
| — | 3.00 | — | — | ||
| Supply, Installation and commissioning Electronic LC gate telephone systems with voice recorder as per RDSO Spec.no. RDSO/SPN/TC/51/ 2011 rev 1.0. a) Master telephone with in-built voice logger.(Insp:-Consignee). | — | — | — | 91,121.97 | |
| — | 18.00 | — | — | ||
| Supply, Installation and commissioning Electronic LC gate telephone systems with voice recorder as per RDSO spec.no. RDSO/SPN/TC/51/ 2011 rev 1.0. b) Slave telephone.(Insp:-Consignee) | — | — | — | 1,25,365.32 | |
| — | 3.00 | — | — | ||
| " Supply, Installation and commissioning Electronic lc gate telephone systems with voice recorder as per RDSO spec.no. RDSO/SPN/TC/51/ 2011 rev 1.0. c) 24v power pack with mf battery - 7 AH for lc gate telephone".(Insp:-Consignee) | — | — | — | 25,843.26 | |
| — | 10000.00 | — | — | ||
| "Excavation of Trench in all kinds of soil and refilling of trenches (1.2 Mtr, Depth, 300 mm Width) - without bricks. Note:-(I) Payment will be made as per actual work done on pro ratabasis, if required depth is not available at site. (II) If the depth of trench is not uniform in a span of 100 mtr.or shorter length, if site condition demands along the cable run minimum depth will be taken for that particular stretch for payment" | — | — | — | 14,63,700 | |
| — | 40.00 | — | — | ||
| "Laying cables of different sizes as per cable route planapproved by Railway and meggering of all main & tail cablesas per technical specification of tender.2 core to 12 core signalling cable" | — | — | — | 4,70,276.8 | |
| — | 6.00 | — | — | ||
| " Laying cables of different sizes as per cable route planapproved by Railway and meggering of all main & tail cablesas per technical specification of tender. Telecom cable 5 Prs./10 Prs./Quad" | — | — | — | 76,377.66 | |
| — | 600.00 | — | — | ||
| "Supply of G.I. Pipe with threaded collars of 100 mm nominalbore specn. No. IS 1239 medium grade. Perforated of required length on bridge / below metaled road/ L-xing /Culvert as per technical specification of tender.A) Supply portion for the G. I. Pipe & collars".(Insp:-RITES) | — | — | — | 7,45,038 | |
| — | 600.00 | — | — | ||
| "Fixing of G.I. Pipe with threaded collars of 100 mm nominalbore specn. No. IS 1239 medium grade. Perforated of required length on bridge / below metaled road/ L-xing /Culvert as per technical specification of tender.B) Execution with remaining miscellaneous materials" | — | — | — | 56,232 | |
| — | 375.00 | — | — | ||
| "Supply of galvanized iron trucking with cover of samematerials as per DRG. No. SGW/MGS/C7/91 and fixing ongirder bridges including supply of channel, angle iron, bracketunits, nuts and bolts of proper size & fitting of support at aninterval of 1mtr including laying of cables inside the trough &filling with bitumen compound as per spec. no. IRS:TC-25/76after cable is laid. Bitumen compound and other materials asrequired for the work shall be supplied by the contractor.a) Supply portion".(Insp:-RITES) | — | — | — | 8,20,957.5 | |
| — | 375.00 | — | — | ||
| " Fixing of galvanized iron trucking with cover of samematerials as per DRG. No. SGW/MGS/C7/91 and fixing ongirder bridges including supply of channel, angle iron, bracketunits, nuts and bolts of proper size & fitting of support at aninterval of 1mtr including laying of cables inside the trough &filling with bitumen compound as per spec. no. IRS:TC-25/76after cable is laid. Bitumen compound and other materials asrequired for the work shall be supplied by the contractor. b)Execution Portion." | — | — | — | 3,04,057.5 | |
| — | 1500.00 | — | — | ||
| "Transportation of HDT machine with accessories including handling of stores materials, preparation of site and boring of110mm dia or above to suit site requirement and placing HDPE pipe of size 63 to 50 mm in single / double /triple etc required for crossing/laying of RailwayS&T cables in acombination of quad & signalling cables etc. as per required comprising upto 72 cores in any HDD section on land/bridges / culverts / track /pucca road crossing and blowing pulling of Quad /S&T cables within HDPE pipe. Boring of trench shall be minimum 3 (three) meter or more below the river bed, 01 (one) Mtr below or more the track and 1.5 (one point five) meter below or more other lands including road /pucca road crossing area. This includes supply of permanently lubricated HDPE pipe of size 63 to 40 mm dia& its accessories suitable for HDT as per Specification No.RDSO/SPN/TC/45/2013 Rev.2.0 with Amdt. 3 or latest amendment & cost of the fuel and all other items which will be required for laying of cable through it.Inspection : Consignee for HDPE pipe NOTE: The number of HDPE pipes (of any dia as mentionedabove) to be pulled in any HDD section will depend upon thenumbers of S&T cables to be pulled through that HDD section as per site requirement. At a particular site, the second /additional HDD is to be done only after completing thepullingof 72 cores of cable through 1st HDD other wise thesecond / additional HDD will not be counted as anew/additional HDD for the purpose of billing. Only S&Tcables to be supplied by Railway. Printed Cable sketch planshowing dirversion& depth, which shall be generated bymachine to be submitted by firm just after every boring & to be submitted while billing. " | — | — | — | 25,97,970 | |
| — | 600.00 | — | — | ||
| " Excavation of trench less trench/manual boarding paring size up to 110 mm) up to a depth of minimum 1.0 meter along withlaying of HDPE/DWC pipe and its accessories, all other itemswhich will be required for laying of cable throughHDPE/DWC Pipe (Track/Road Crossing) as per requirementat site."(Insp:-Consignee). | — | — | — | 5,40,462 | |
| — | 18.00 | — | — | ||
| Supply of full size location box as per design of GKP signal workshop.(Insp:-Consignee) | — | — | — | 4,88,244.06 | |
| — | 18.00 | — | — | ||
| "Casting, Concreting and Curing of foundation and erection for full apparatus case(GKP- type) as per DRG No. SGW/MGS/L1/91 including cost of all materials required for fixing holding down bolts, casting, concreting and fixing of""E"" type lock.Note :i) The contractor will provide holding down bolts, ii) Bottom of apparatus cases should be filled with sand and the top surface covered with masonry work and neat cementing" | — | — | — | 1,28,362.86 | |
| — | 90.00 | — | — | ||
| Supply of Bakelite Strip/Sheet of size (950 x 75 x 12) mm. For fixing 30 nos. ARA terminals/Fuse base terminals/Fuse base.(Insp:-Consignee) | — | — | — | 57,545.1 | |
| — | 18.00 | — | — | ||
| "Fixing, wiring of terminal strips, Bakelite strip, transformers, relays fuses with base and supply and fixing of shelves for full apparatus case with termination earthing of cable and wiring with lettering as required including supply of wires and miscellaneous materials, sand filling and plastering over sand filling per location.(All materials except transformers, relay,terminal strips, Bakelite strip and fuses with base to be supplied by the contractor.) | — | — | — | 80,878.68 | |
| — | 36.00 | — | — | ||
| "Supply of E-type lock without key, spec .no.IRS-S-30, Drg.no.S-3376/M key-S-3377/M. Individual number of miniature E locks and Normal size of locks required at site to be decided by the site engineer as per site requirement."(Insp:- RDSO) | — | — | — | 59,399.64 | |
| — | 6.00 | — | — | ||
| Key for E type lock supplied above.(Insp:-Consignee) | — | — | — | 1,486.56 | |
| — | 36.00 | — | — | ||
| Supply of slotted angle (40 x 40 x 2 mm).(Insp:-Consignee) | — | — | — | 10,705.32 | |
| — | 6.00 | — | — | ||
| "Supply of paper base hylum sheet 12 mm thick."(Insp:-Consignee) | — | — | — | 50,473.62 | |
| — | 40.00 | — | — | ||
| Supply and transportation of Earth Electrode as per Drg.Nos.RE/33/P/7021 (MOD.''F'') or latest.(Insp:-Consignee) | — | — | — | 2,08,880 | |
| — | 75.00 | — | — | ||
| Supply and transportation of Earth Leads 50mmx6mm mild steel for earthing as per Drg. Nos. RE/33/P/7021 (MOD. ''F'') or latest.(Insp:-Consignee) | — | — | — | 13,425 | |
| — | 40.00 | — | — | ||
| "Excavation of earth pit, placing & fixing of Earth electrode with construction of cement enclosure to SEM Drawing Nos. 19-D6 and drawl of 6 SWG GI/Copper cable from earth electrode to goomties/relay room/cabin/station, etc. and drawl of MS flat 35mm x 6mm for signal post/Location box shall be used as the case may be, including fixing at both ends of the wire/MS flat. This includes transportation of materials. Note: Materials such as charcoals, salt, sal ammoniac, 6 SWG GI wire, copper lugs with Steel bolts & nuts etc. shall be supplied by the contractor. MS flat 35mm x 6mm/Copper cable shall be supplied by Railway." | — | — | — | 61,600 | |
| — | 18.00 | — | — | ||
| Supply of CLS Post 4.5 mtr. and Ladder 4.5 Mtr. With bases as per RDSO DRG.No.SA.5533/ADV and RDSO Spec.No.S6-81.(Insp:-Consignee) | — | — | — | 4,34,076.84 | |
| — | 18.00 | — | — | ||
| Casting, concreting and curing of foundation for Main signal and as per DRG.No. SGW/MGS/S1/91 including COST of all materials required for casting and concreting and provision of holding down bolts & nuts | — | — | — | 1,69,628.94 | |
| — | 1.00 | — | — | ||
| " Supply, Installation, erection and wiring of CLS unit (NonMetallic (FRP) colour light signal housing multi-unit type), LED unit including paying out of tail cable from Location Box and earthing of CLS (LED type).This includes supply of Non Metalic (FRP) Color light signal housing multi unit type for Railway signalling suitable for RE area, FOUR aspectcomplete (without lenses, lamps and signal transformer) as per RDSO Drg. No. SA- 23002/A/M/ADV,ALT-8 and as per Spec No RDSO/SPN/194/2006 (version 1.0) with latest amdt. and FRP material as per RDSO Spec No. RDSO/SPN/151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only.NOTE:- Installation, erection & wiring of signalling unit includes LED signal lightning unit including current regulator. This also includes protection of unit from Rain water. Signal unit should be compatible to 'LED type. .(i) Supply"(Insp:-Consignee) | — | — | — | 44,356.08 | |
| — | 1.00 | — | — | ||
| " Installation, erection and wiring of CLS unit (Non-Metallic (FRP) colour light signal housing multi-unit type) LED unit including paying out of tail cable from Location Box and earthing of CLS (LED type).This includes supply of Non Metalic (FRP) Color light signal housing multi unit type for Railway signalling suitable for RE area, FOUR aspectcomplete (without lenses, lamps and signal transformer) as per RDSO Drg. No. SA-23002/A/M/ADV,ALT-8 and as per Spec NoRDSO/SPN/194/2006 (version 1.0) with latest amdt and FRPmaterial as per RDSO Spec No. RDSO/SPN/151/1997 or latest.All drawings should be as per latest. Material to be procured from RDSO's approved firm only. NOTE:- Signal unit should becompatible to 'LED type. NOTE:- Installation, erection & wiringof signalling unit includes LED signal lightining unit includingcurrent regulator. This also includes protection of unit from Rain water.(ii) Execution" | — | — | — | 3,391.47 | |
| — | 12.00 | — | — | ||
| "Installation, erection and wiring of CLS unit (Non-Metallic (FRP) colour light signal housing multi-unit type), LED unit including paying out of tail cable from Location Box and earthing of CLS (LED type).This includes supply of Non Metalic (FRP) Color light signal housing multi unit type for Railway signalling suitable for RE area, Two aspectcomplete (without lenses, lamps and signal transformer) as per RDSO Drg. No. SA-23003/A/M/ADV,ALT-8 and as per Spec No RDSO/SPN/194/2006 (version 1.0) with latest amdt and FRP material as per RDSO Spec No. RDSO/SPN/151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only.NOTE: - Installation, erection & wiring of signalling unit includes LED signal litghtening unit including current regulator. This also includes protection of unit from Rain water. Signal unit should be compatible to 'LED type.(i) Supply"(Insp:-Consignee) | — | — | — | 4,05,333.12 | |
| — | 12.00 | — | — | ||
| "Installation, erection and wiring of CLS unit (Non-Metallic (FRP) colour light signal housing multi-unit type), LED unit including paying out of tail cable from Location Box and earthing of CLS (LED type).This includes supply of Non Metalic (FRP) Color light signal housing multi unit type for Railway signalling suitable for RE area, Two aspect complete (without lenses, lamps and signal transformer) as per RDSO Drg. No. SA-23003/A/M/ADV,ALT-8 and as per Spec No RDSO/SPN/194/2006 (version 1.0) with latest amdt and FRP material as per RDSO Spec No. RDSO/SPN/151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only.Note: - Installation, Erection & wiring of signalling unit includes LED signal litghtening unit. This also includes protection of unit from rain water. Signal unit should be compatible to LED type(ii) Execution" | — | — | — | 25,352.16 | |
| — | 5.00 | — | — | ||
| "Supply Installation, erection and wiring of CLS unit (Non-Metallic (FRP) colour light signal housing multi-unit type),LED unit including paying out of tail cable from Location Box and earthing of CLS (LED type).This includes supply of Non Metalic (FRP) Color light signal housing multi unit type for Railway signalling suitable for RE area, THREE aspect complete (without lenses, lamps and signal transformer) as per RDSO Drg. No. SA-23002/A/M/ADV,ALT-8 and as per Spec NoRDSO/SPN/194/2006 (version 1.0) with latest amdt and FRP material as per RDSO Spec No. RDSO/SPN/151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only.NOTE:- Signal unit should be compatible to 'LED type.NOTE:- Installation, erection & wiring of signalling unit includes LED signal lightining unit including current regulator. This also includes protection of unit from Rain water.(i) Supply".(Insp:-Consignee) | — | — | — | 1,83,091 | |
| — | 5.00 | — | — | ||
| "Installation, erection and wiring of CLS unit (Non-Metallic (FRP) colour light signal housing multi-unit type),LED unit including paying out of tail cable from Location Box and earthing of CLS (LED type).This includes supply of Non Metalic (FRP) Color light signal housing multi unit type for Railway signalling suitable for RE area, THREE aspect complete (without lenses, lamps and signal transformer) as per RDSO Drg. No. SA-23002/A/M/ADV,ALT-8 and as per Spec NoRDSO/SPN/194/2006 (version 1.0) with latest amdt and FRP material as per RDSO Spec No. RDSO/SPN/151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only.NOTE:- Signal unit should be compatible to 'LED type.NOTE:- Installation, erection & wiring of signalling unit includes LED signal lightining unit including current regulator. This also includes protection of unit from Rain water.(ii) Execution" | — | — | — | 12,876.4 | |
| — | 200.00 | — | — | ||
| Supply of PBT ARA terminal as per IRS SPECN No .IRS:S-75-91 1) 6 way.(Insp:-RDSO). | — | — | — | 1,21,694 | |
| — | 40.00 | — | — | ||
| "Supply of PBT fuse block with inserts cartridge type, to be mounted inside the location Box/Relay Rack.i) Fuses (2A, IRS : S 78/92(latest))."(Insp:-RDSO). | — | — | — | 6,510 | |
| — | 140.00 | — | — | ||
| " Supply of PBT fuse block with inserts cartridge type, to be mounted inside the location Box/ Relay Rack. Fuse Base (DRG No. SA - 23748, IRS: S-75/91)"(Insp:-RDSO). | — | — | — | 36,695.4 | |
| — | 20.00 | — | — | ||
| Supply of Non deteriorating type low voltage cartridge fuse as per Spec. No. IRS/S/78/92. Round head type.ii)6 Amp. Capacity.(Insp:-RDSO). | — | — | — | 2,425.8 | |
| — | 20.00 | — | — | ||
| Supply of Non deteriorating type low voltage cartridge fuse as per Spec. No. IRS/S/78/92. Round head type.iv)16 Amp. Capacity.(Insp:-RDSO). | — | — | — | 2,262.6 | |
| — | 1200.00 | — | — | ||
| "Termination of cable cores on ARA terminals or on 8 wayterminals in the cable termination rack" | — | — | — | 22,776 | |
| — | 900.00 | — | — | ||
| "Supply of Disconnect type Terminal, screwless, 2 IN 2 OUT (as per spec. no. RDSO/SPN/189/2004 or latest) along with allaccessories including separators for fixing on Cable Termination Rack/Location boxes for Cable Termination Purpose"(Insp:- RDSO). | — | — | — | 94,275 | |
| — | 120.00 | — | — | ||
| "Supply of screwless end stop, 10mm/0.394 in wide carmer rail din35, grey similar to Wago part No. 249-117". (Insp:-Consignee) | — | — | — | 2,474.4 | |
| — | 40.00 | — | — | ||
| "Supply of steel carrier rail 35 x 7.5mm, 1mm/0.039 in thick,unslotted similar to 23 Wago part No. 210- 229/PW11- 0000."(Insp:-Consignee) | — | — | — | 7,084.8 | |
| — | 900.00 | — | — | ||
| Fixing installation of disconnect terminal (Wago or Similar) on relay rack/ctr/location with steel carrier rail. | — | — | — | 1,368 | |
| — | 36.00 | — | — | ||
| "Supply of PVC wire coil of size of colours as per instruction of site engineer in 100 mtr. Coils. Spec.no. IRS S-76/89 material to be procured from RDSO approved firm only withperformance guarantee. (a) 16/0.2 mm. (Unit Qty. Numbers ,means per coil.)"(Insp:-RDSO) | — | — | — | 42,647.04 | |
| — | 6.00 | — | — | ||
| "Supply of PVC wire coil of size of colours as per instruction of site engineer in 100 mtr. Coils. Spec.no.IRS S-76/89 material to be procured from RDSO approved firm only withperformance guarantee. (b) 3/0.737 mm. Inspection RDSO. (Unit Qty. Numbers means per coil.)".(Insp:-RDSO) | — | — | — | 15,905.52 | |
| — | 6.00 | — | — | ||
| "Supply of PVC wire coil of size of colours as per instruction of site engineer in 100 mtr. Coils. Spec.no. IRS S-76/89 material to be procured from RDSO approved firm only withperformance guarantee. (c) 7/0.75 mm. Inspection RDSO. (Unit Qty. Numbers means per coil.)".(Insp:-RDSO) | — | — | — | 32,969.52 | |
| — | 6.00 | — | — | ||
| " Supply of enamelled number plate of size 8"" Dia (letter inblack on white background with complete clamping arrange-23476 (ADV.) G-Marker".(Insp:-Consignee) | — | — | — | 2,983.26 | |
| — | 6.00 | — | — | ||
| " Supply of enamelled number plate of size 8"" Dia (letter inblack on white background with complete clamping arrange-23476 (ADV.).ii) P- Marker".(Insp:-Consignee) | — | — | — | 2,667.96 | |
| — | 18.00 | — | — | ||
| "Supply of MS number plate (200mmx300mmx3 mm ) with fixing calmps. Letter shall be of black colour in the white background. Details of description shall be given by site engineer.The plate & clamps shall be painted before lettering of signal numbers".(Insp:-Consignee) | — | — | — | 17,188.02 | |
| — | 6.00 | — | — | ||
| " Supply & Erection of passenger/Goods Warning Boards as perDrg.No.SA 2380 ADV with reflecting strips."(Insp:- Consignee) | — | — | — | 56,680.98 | |
| — | 3.00 | — | — | ||
| "Supply of Micro Processor based Remote Terminal Unit(RTU) with 128 digital input & 16 analog input with A4 Laserprinter 22 ppm (Only baranded HP/Brother/Canon) as per RDSOSpec. No. IRS (S) 99/2006 with Amdt. 3.0 or latest. It includessupply of all the items required for complete indoor relay roomwiring from RTU to relay rack tag blocks, drawing/extension of power supply up to RTU. It includes supply of relay room doorlock checking arrangement, commercial power supply monitoringarrangement & monitoring of DG sets, ELD (if installed), IPS,interlinking and networking of RTU. It also includes supply ofleased line MODEM, suitable online UPS (minimum 6 hoursbackup) and other interfacing cards, if required for networking ofData Logger. Note (1) Total numbers of relays and other signallingfunctions/gears required to be wired as per list circulated videRDBO Letter No..STS/E/Data logger dtd.12.09.2011 or latestguidelines of Railway Board/RDSO/Zonal Railway. (2)Exceptional reports are to be generated by a computer connected todatalogger at the station and at a central location in Control Room.Datalogger software should be able to generate exceptional reportsfor maintenance, safety and operations as per latest guidelines ofRailway Board/RDSO/Zonal Railway. Datalogger to be installed atSite by OEM. Manufacturing date of RTU and printer should be ofcurrent year at the Inspection:"(Insp:-RDSO). | — | — | — | 6,17,281.83 | |
| — | 3.00 | — | — | ||
| "Installation, wiring, testing & commissioning of MicroProcessor based Remote Terminal Unit (RTU) with 128/64digital input & 16 analog input as per RDSO Spec. No. IRS (S)99/2006 with Amdt. 3.0 or latest. It covers complete indoor relay room wiring from RTU to relay rock tog blocks, drawing/extension of power supply up to RTU. It includes relay room door lock checking arrangement. commercial power supply monitoring arrangement & DO sets, ELD (if installed), IPS, interlinking and networking of RTU. All material required for wiring, networking. power supply monitoring, door locking arrangement etc. will be supplied by contractor. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd. 12.09.2011 or latest guidelines Board/RDSO/Zonal of Railway Railway Networking of data logger includes extraction of data report from Control room. Exceptional reports are to be generated by a computer connected to datalogger at the station, El Huts, LC Gates, AFTC Huts etc. and at a central location in Control Room. Datalogger software should be able to generate exceptional reports for maintenance, safety and operations as per latest guidelines of Railway Board/RDSO/Zonal Railway. Datalogger to be installed at Site by OEM. For networking, required communication channel (Quad/ OFC cable) will be arranged/provided by Rly in SM/ASM's room or in OFC/AUTO/EI Huts/LC Gates etc. and it will be extended by contractor up to location of data logger by using CAT-5/6 telecom cable with proper casing and capping. The contractor will supply all the material like CAT-5/6 telecom cable, casing & capping, nuts, bolts etc. The final commissioning will be done after filling up of Pre Commissioning checklist (circulated by RDSO) with the OEM representative. Datalogger to be validated and commissioned before simulation test and put in network, validation statement should be jointly signed by railway engineer (open line), railway engineer (construction) & OEM'S engineer before simulation test with name, designation and date. Payment for this item will be released only after submission of duly signed pre-commissioning checklist of data logger in standard RDSO format, joint signature of validation statement. OEM'S engineer will also impart training to rly staff at site for proper functioning/working and applications of data logger.Installation" | — | — | — | 42,157.8 | |
| — | 3.00 | — | — | ||
| " Supply of CT rack (DRG.N0.S&T/C-19/ 2001/ER) complete withall fittings including 6 way/8 Way PBT Terminals as per Spec No.IRS-79/92.or Wagoo terminals as decided by site in charge. (Insp:PBT terminals to be inspected by RDSO and CT- Rack, Wagoo by Consignee.") | — | — | — | 1,79,829.18 | |
| — | 3.00 | — | — | ||
| "Installation of cable termination Rack with scaffolding materials;ladder for supporting outdoor cable; wire guide; complete withother necessary hardwares as per requirements of Rly. & erectionmaterials. (Station Wise Qty. to be specified by the tenderer.)Upto 4 to 5 Line Station" | — | — | — | 17,982.93 | |
| — | 60.00 | — | — | ||
| "Carrying out alterations to the existing relay wiring at relayrack/location as per the circuit diagram. The work includesreleasing the existing unused wires and wiring the relays usingwire PVC 16/0.02 mm copper. (Wire PVC 16/0.02 mm copper,paint, soldering materials and all other miscellaneous materialsrequired for the work shall be supplied by the contractor." (Unit 'Each' stands for 'Per Relay'). | — | — | — | 30,193.2 | |
| — | 3.00 | — | — | ||
| "Preparation and supply of laminated one set of all the completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75 micron polyester film for Mid-Section Interlocked LC Gate (OSL) on Auto CAD. 6 (Six) sets xerox copies will be provided for each of the documents mentioned below: Cable Route Plan, Cable Core Chart, Location details plan for all the locations, Cable termination details, Signalling Plan, SWR Diagram, Wiring Diagrams, Contact Analysis, Fuse and Tag Block Analysis of Relay Rack and CT Rack, Control Cum Indication Panel/VDU Diagram, Power Panel Diagram, Track Circuit Plan, RackErection Plan and Junction Box details etc".(Insp :-Consignee.) | — | — | — | 31,366.05 | |
| — | 18.00 | — | — | ||
| "Painting of two coats of enamel paints lover one coat of red oxide primer and there after numbering on the following itemsafter scraping and cleaning of the surface where ever necessary. Primer and paints both Asian paint make are to be supplied by the contractor. Numbering is to be as per practiceof the ECR and directives of the site Engineer. (i) Location boxes inside and outsided surfaces with Aluminum paint.(a) Single case" | — | — | — | 16,638.3 | |
| — | 18.00 | — | — | ||
| "Painting of two coats of enamel paint over one coat of red oxide primer and there after numbering on the following itemsafter scraping and cleaning of the surface where ever necessary. Primer and paints both Asian paint make are to be supplied by the contractor. Numbering is to be as per practiceof the ECR and directives of the site Engineer.Main signal post, signal unit, Surface base and complete fitting as per E.C.Rly standard practice" | — | — | — | 19,951.56 | |
| — | 12.00 | — | — | ||
| "Supply of electrical key transmitter for crank handle interlocking arrangement siding control, LC Gate control as peryard diagram, approved circuit diagram and IRS Spec.No.IRSS-21/64.and IRS S-23 (latest)".(Insp:-RDSO). | — | — | — | 1,19,886.12 | |
| — | 6.00 | — | — | ||
| "Supply of basic material to construct unit Maintenance FreeEarth for Single Earth consisting as per Spec. Nos.RDSO/SPN/197/2016 Ver 1.0 or latest, bondingconnections drawing Nos. SDO/ RDSO/E&B/002 or latest areas under,(a) Copper bonded steel electrodes of 3.0 m long,17.0 mm diameter with copper bonding thickness of min 250micron and UL listed and marked -1 Nos. (b) EarthEnhancement compound supplied in sealed bags of min 30-35Kg.- 1 Nos. (c ) Copper Strip of 200mm x 25mm x6mm toexothermically welded to Earth electrode- 1 Nos.(d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1 Nos. (e)Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 Nos. Italso includes supply of (i) 35 Sq. mm Multi-strand SingleCore PVC insulated Copper Connector as per IS:694 forconnecting Main Earth Electrode to MEEB in the equipmentroom in duplicate.-10 meter (ii) 16 Sq. mm Multi-strandSingle Core PVC insulated Copper Connector as perIS:694 for connecting MEEB to SEEB and SPDs toMEEB.-10 meter (iii) 10 Sq. mm Multi-strand Single CorePVC insulated Copper Connector as per IS:694 forconnecting various equipment to SEEB- 10 meter".(Insp:-RDSO). | — | — | — | 1,25,292 | |
| "Installation of Single Maintenance Free Earth pit as per RDSODrawing Nos. SDO / RDSO/ E&B/001 which includes thefollowing,a) Digging/Auguring/Boring of single earth pit of100mm to 125mm dia. to the depth of approx. 3 meter.b) Insertion of 3.0 meter electrode and penetrating itminimum 150 mm by pushing gently with sledgehammer where the natural soil is assumed. (c) Filling of earthpit with Earth Enhancement Compound (EEC) in slurryform and backfilling. (d) Carrying out exothermic weldconnection on single earth electrode to a copper tape of 200x 25 x 6 mm. (e) Carrying out exothermic weldconnection on the copper tape of 200 x 25 x 6 mm on EarthElectrode for connecting two 35 Sq. mm cables forredundancy. (f) The exothermic welding material for bondingthe earth system shall be procured from RDSO approvedfirms, which includes graphite modules, clamps, weldmetal powders etc. (g) The dimension of the chamber willbe of 300 x 300 x 300 mm (inside dimension) of RCCwith 50mm thick and fine finish, Inspection chambershould be as per IEC 62561-5 or latest. The top RCCcover size shall be 400 mm X 400 mm X 50mm. The date oftesting and earth resistance value shall be written on the coverwith black base with yellow paint or as per instruction of siteengineer.Installation" | — | 6.00 | — | — | |
| — | 30.00 | — | — | ||
| " Providing and laying in position cement concrete of 1:3:6 (1cement 3 sand: 6 graded stone aggregate 20 mm nominal size)Including cement." | — | — | — | 1,61,773.8 | |
| — | 6.00 | — | — | ||
| "Supply of Thermo-shrink jointing (TSF) kits for jointingunderground Quad cable of size 0.9mm/1.4mmdiameter conductor for straight/condenser/Y-(Derivation)/Loading Coil/Transformer Joints as perSpecification Nos. IRS-TC-77/2012 Rev.3 with Amd. 3.0or latest. "(Insp:-RDSO) | — | — | — | 19,560 | |
| — | 6.00 | — | — | ||
| "Execution of Straight joint on Quad cable/ jelly filledTelecom cable using Thermo-shrink/Universal jointing kit(RTSF). This includes excavation of cable joint pit of size1.5 m X 1.5 m X 1.2 m for jointing of cables, back fillingand ramming after jointing. After jointing, the cablethrough test such as insulation test, continuity test etc.to be carried out jointly with Railway Engineer. If anydefect or any damage is observed during jointing thecontractor has to redo the joint free of cost.Note: In casejointing is required to be done in the Location boxes,then 80% payment will be released" | — | — | — | 8,988 | |
| — | 6.00 | — | — | ||
| "Supply & installation of OFC joint closure as per Tech.Spec. No.G/OJC-02/01Mar'99 with latest amendments &splicing of 24 Fibre Optic Fibre Cable this includes ofjointing pit (RCC & Pre-fabricated) & testing and keepingin the pit then filling the pit with sand. The work will bedone as per technical specifications and as advised by siteengineer"(Insp:-Consignee) | — | — | — | 1,89,536.94 | |
| — | 300.00 | — | — | ||
| — | — | — | 3,48,060 | ||
| double walled with IS and inner dia | : - "Supply of power/communication/Signal/OFCprotection outer dia 175mm | DWC pipe 16205 part-24:2018 148mm"(Insp:-Consignee) | for and T-Joint | ||
| — | 300.00 | — | — | ||
| Installation of Double Wall Corrugated (DWC) pipe with socket coupler. This includes trenching 1.2 mtr. Depth and back filling | — | — | — | 32,754 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderNotice.pdf
ATTACHMENT
Tender_1stsheet.pdf
ATTACHMENT
Annexures.pdf
ATTACHMENT
GCC2022WithACS_101.pdf
ATTACHMENT
ACS-11-GCC-2022.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .