| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC 2ND FLOOR PLOT NO 338 UDHYOG VIHAR PHASE IV GURUGRAM 122015 HARYANA | GURUGRAM | HARYANA | 122015 | ₹2.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.9 Cr+₹7.1 L (2.50%)Rejected-Finance 104 105 SUNEJA TOWER 1 DISTRICT CENTRE JANAKPURI NEW DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | ₹2.9 Cr+₹7.1 L (2.50%) | L2 | Rejected-Finance L2 |
| 3 | Not Admitted-Fee/PreQual/Technical UNIT NO 1005 10TH FLOOR JMD MEGAPOLIS SOHANA ROAD SEC 48 GURGAON 122018 | GURUGRAM | HARYANA | 122018 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹2.6 Cr
EMD Value
₹5.2 L
Closing Date
17 Mar 2025, 5:30 pmClosed
NAVIN KUMAR
ED - Gurgaon
Providing DG sets and Independent Feeder in the Construction of New Judicial Courts Complex (Tower Of Justice) Gurugram (Providing Additional Court Room Display System)
2025_HRY_432331_1
20256FB9786A DAFF 452B AA44 A26660372667664BAR
Open Tender
Electrical Works
Works
210 days
Gurugram
2 documents required · 2 mandatory
₹15,000
₹5.2 L
Yes
27 Jun 2025
7 Mar 2025
18 Mar 2025
7 Mar 2025
17 Mar 2025
7 Mar 2025
7 Mar 2025 - 8 Mar 2025
Amount
COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLs copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C
Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfactionPVC pipe of 25 mm dia. of Engineer-in-Charge of work.
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp, 25 KA
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
Supplying and drawing of 1 no UTP 4 pair CAT 6a LAN Cable in the existing surface/recess MS/PVc conduit as required
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe complete in all respect upto the entire satisfaction of Engineer in charge of the work 2.5 sq.mm
Supply and erection of Double door sheet, steel Vertical distribution boards suitable for FP MCCBs. MCCB upto125 amp as incomer (but without cost of MCCBs) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (loadline) 4 way load line
8 way load line
Supply Installation Testing & Commissioning of 50'' or better with 700 NITS Professional LED Display with Media Player for Inside / Outside Court Halls with Mounting Arrangements, As per specification & at site of work in line with the Engineer in Charge instructions. Including cost of labour and material for errection the same on wall/ceiling . Make: SAMSUNG/PROMARK/PROMINE other specifications as per DNIT in PDF.
Supply Installation Testing & Commissioning of 85” 500 NITS Professional LED Display with Media Playe for building Reception with Mounting Arrangements, As per specification & at site of work in line with the Engineer in Charge instructions. Including cost of labour and material for errection the same on wall/ceiling . Make: SAMSUNG/PROMARK/PROMINE other specifications as per DNIT in PDF.
Supply Installation Testing & Commissioning of Server 2 x Intel® Xeon® E5-2620v4 (2.1GHz/8-core/20MB/85W) 2 x 16 GB DDR4-2400 R Memory 8 x HPE 1.8TB SAS 10K SFF SC 512e DS HDD HP H240 12Gb 2-ports Int Smart HBA HP SATA 9.5 JB Optical HDWR 2 x HP 900W AC 240VDC Power Module Make: HP/Dell/IBM other specifications as per DNIT in PDF.
Supply Installation Testing & Commissioning of 55'' LED display, As per specification & at site of work in line with the Engineer in Charge instructions. Make: Samsung/Promark/Promine
Supply, Installation, Testing & Commissioning of 24 Port Access Switch with 24x 1G Base-T& 4x1G SFP Slots/2 nos stacking port, with switching capacity 56 Gbps, Should support for ACLs based on L3 and L4 headers, DHCP snooping, DHCPv4 (Snooping, client), Dynamic ARP Inspection (DIP), RADIUS, TACACS+, SSL, SSH, SSL v2 and v3, SFTP, SNTP, NTP, Port Mirroring, Dynamic VLAN assignment and Tri-authentication such as MAC-based , web-based and IEEE 802.1x port based authentications and NAC for managing endpoint security, SNMPv1, v2c and v3, TFTP, Web GUI, CLI, USB or equivalent memory card, IPv4 and IPv6 management features and Control plane prioritization, Management stacking supports up to minimum 8 devices to be managed from a single console, Should support for centralized management, auto-backup, auto-upgrade, auto-provisioning and auto-recovery for seamless and simplified network operations and management and open flow v1.3, Non-blocking switching and wire speed forwarding rate, Standards: UL60950-1, CAN/CSA-C22.2 No. 60950-1-03, EN60950-1, EN60825-1, AS/NZS 60950.1 Certifications: UL, cUL, UL-EU, EMC: EN55022 class A, FCC class A, VCCI class A, Immunity: EN55024, EN61000-3-levels 2 (Harmonics) and RoHS, Operating Temperature- 0°C to 45°C (32°F to 113°F) complete in all respect upto the entire satisfaction of Engineer-in-charge of work. Make: Alcatel Lucent / Cisco / Allied Telesis
Supply, Installation, Testing & Commissioning of 24 port Core Switch (L3 switch) with 24x1G 1000 Base-T ports and 4x1G SFP slots with minimum switching capacity of 56Gbps , should support stacking up to 8 switches with stacking bandwidth of 16Gbps. It should have internal single Power Supply, AC voltage: 90 to 260V (auto-ranging), IPv6 logo ready, Tri-authentication: MAC-based, web-based and IEEE 802.1x, Access Control Lists (ACLs) based on layer 3 and 4 headers, Operating temperature range: 0°C to 45°C (32°F to 113°F) Derated by 1°C per 305 meters (1,000 ft), Certification: UL, cUL, TUV, FIPS 140-2, Stacking cables and associated accessories will be provided with switch complete etc. as required. Make: Alcatel Lucent / Cisco / Allied Telesis
Supply Installation Testing & Commissioning of 12U (600x550)mm rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit. As per specification & at site of work in line with the Engineer in Charge instructions. Make: Comrack/Hive Networks/Rittal
Supply Installation Testing & Commissioning of 22U (600x600)mm rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit. As per specification & at site of work in line with the Engineer in Charge instructions. Make: Comrack/Hive Networks/Rittal
Supplying, installing, testing and commissioning of 24 port Cat 6A patch panels available with block of four equipped with tool less IO, Rack Mountable. 19" Modular Patch Panel, loaded CAT6A U/UTP 24 port LCS2 rack mountable to be compatible in 4nos of 6 X RJ 45 Tool less connector U/UTP unit in a block complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer -incharge of work. Make : Legrand / Corning / R&M
Supply installation ,testing and commisioning of 30 KVA UPS invertor on Line With 30 mins Backup complete in all respect upto the entire satisfaction of Engineer-in-charge of work MAKE APC / EMERSON / EATON
Supply Installation Testing & Commissioning of 6 core mm fibre cable (per meter) complete with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer - in - charge of work. Make : Legrand / Corning / R&M
Supply Installation Testing & Commissioning of 12F, 1U, LC, LIU Loaded with Pigtails, Splice tray, Couplers As per specification complete in all respect upto the entire satisfaction of Engineer-in-charge of work Make : Legrand / Corning / R&M
Supply Installation, testing and commissioning of PATCH CORD LC-LC SM DUPLEX LENGTH- 7ft. As per specification complete in all respect upto the entire satisfaction of Engineer-in-charge of work Make : Legrand / Corning / R&M
Supply, Installation, Testing and comissioning of 1G SFP module as required (For All Switches) complete in all respect upto the entire satisfaction of Engineer-in-charge of work Make: Cisco / Alcatel Lucent / Allied Telesis
Supplying, installing, testing and commissioning of following length of Cat - 6a patch cord. 4 Feet : CAT6A UTP 23 AWG Patch Cord - 1 mtr - Rack End. Factory crimped LCS2 Patch cord. Make : Legrand / Corning / R&M
Supplying, installing, testing and commissioning of Cat 6A , Tool less Information outlet for Voice/Data. Cat6A U/UTP built in crimping hands-free, minimum 5 times reconnection possibilities. LCS2 Toolless RJ45 Information outlet where insertion test (in & out) must be 2500 times (I/O) along with front side Label holded and transparent shutter for category white in colour, including front plate and anodised GI box in concealed manner of adequate sizes,including all fixing accessories complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer -in-charge of work. Make : Legrand / Corning / R&M
Infosoft Digital Design and Services Pvt Ltd (BID ID -1224811)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .