| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-Finance PP 32 MAURYA ENCLAVE PITAMPURA CHAITANYA CONSTRUCTION CO PP 32 MAURYA ENCLAVE PITAMPURA DELHI NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | L1 | Accepted-Finance ok | |
| 2 | L2₹7.7 L+₹46,780.80 (6.47%)Accepted-Finance 2 MORE SARAI CH CHOWK DELHI CENTRAL DELHI DELHI 110006 | NORTH DELHI | DELHI | 110006 | L2 | Accepted-Finance ok |
Tender Value
Refer Docs
EMD Value
₹14,800
Closing Date
28 Jan 2022, 11:15 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (EnM) M-8
C-2A Block Janakpuri BPS New Delhi-110058.
Improvement of Electrical and Mechanical System at LSC E-Block BPS in Vikaspuri AC-31.
2022_DJB_215227_19
e-NIT No.03 / (EnM) M-8/ 2021-22
Open Tender
Miscellaneous Works
Works
30 days
C-2A Block Janakpuri BPS New Delhi
Please refer Tender Document
3 documents required · 3 mandatory
₹500
Yes
DJB Account No. 50448339804
₹14,800
Yes
23 Feb 2022
21 Jan 2022
28 Jan 2022
21 Jan 2022
28 Jan 2022
21 Jan 2022
120 days
Dismantling of existing old Pump-sets from the M.S base frame and valves, Bends, pipes etc. of both side (suction & delivery side) and panel with all accessories by doing all such work as per site requirement & taking out all the equipments from the base frame/foundation. The job also includes Removing of rusted base frame from the RCC foundation by cutting with gas cutter etc., breaking of foundation and fixing of dead flanges in suction line by welding etc. by taking all precautions as per site requirement.
Dismantling of old /existing starter panel, Kit-kat, changeover switches etc. from site after disconnecting the main incoming & out going electric supply by taking all precautions at site.
S/O Mono Bloc pump-set, 15 HP,Discharge 22 LPS (approx.), at approx. 32 meter head.Make: Kirloskar/ CG/DJB APPROVED.
S/O MS Black pipe 100 mm dia. Medium (B Class).Make: - Jindal/Tata.
S/O C.I.D.F. Non rising with SS spindle sluice valve of size 100mm. PN: 1.0 IS: 14846.Make: Kirloskar / IVC
S/O C.I.D.F. NRV without bye pass swing type of size 100mm, PN: 1.0 IS: 5312.Make: Kirloskar / IVC.
S/O MS D/F Bend of size: 100mm Φ (90⁰), thickness of 15 mm.
S/O MS Flange, of size: 100mm Φ, (Heavy Duty ‘R’ Brand).
S/O Vacuum pump, MOC: SS-rotor, C-40 Shaft, Gland packing-sealing, with 1500 RPM, TEFC motor IP – 55, of 5 HP rating.Make: Kirloskar/DJB Approved
S/O Nut bolt with washers of good quality (off size), as per site requirement.
S/O Neoprene Rubber Packing sheet with 75% neoprene.
Supply of Pressure gauge having 0 to 10 Kg/sq. cm with GI fitting and bib cock Make:- Guru / Feibig
Re-casting/strengthening of RCC foundation, plastering and making wet layer of cement of the foundation i/c. Shuttering etc. as required. Making / fabrication and supply of MS base frame/angle suitable for mono-block pump set. Grouting the foundation nut-bolts, Drilling/ machining and painting as per site requirement or direction of engineer-in-charge ( As per sample)
Supply & Installation of LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire, size 1200MM X 1000MM X 400MM. Having following components make.
MCCB 415V, TP 3phase 50Hz, 160 Amp with handle & spreader - Make L&T
MCCB 415V, TP 3phase 50Hz, 63 Amp with handle & spreader - Make L&T
MCB Single pole 6 Amp. Make L&T/Havells
MCB Triple pole 32 Amp. Make L&T/Havells
MCB Triple pole 40 Amp. Make L&T/Havells
Power capacitors 415V unit of 10 Kvar Make: Epcos
Over load relay 20-33 Make: L&T/siemens
Over load relay 4.5-7.5 Make: L&T/siemens
Digital Amp. Meter Make AE/L&T
Digital Volt Meter0-500V -Make AE/L&T
Motor protection Relay Make: L&T/Siemens/Protech
Power contactor 220V 3 phase 50Amp. Make L&T/siemens
Power contactor 220V 3 phase 32 Amp. Make L&T/siemens
Power contactor 220V 3 phase 18 Amp. Make L&T/siemens
Star delta timer on delay Make: L&T/Siemens
Indicating lights LED type RYB & On/OFF Make : L&T /Havells
Current Transformer 200/5 Make: AE /Advance / Saviour
Current Transformer 250/5 Make: AE /Advance / Saviour
On load change over switch 200 Amp. Open execution type Make: L&T
Fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hard wares complete in all respect.
Supply and laying of PVC/XLPE insulated (HEAVY DUTY),electrical cable for working voltage up to andincluding 1100v polts to IS :1554(part-I) 1988/7088/7098(part-I) 1988 with Copperconductor, unarmored of following sizes:- 3 Core x 10 Sqmm
Loading, Unloading, Cartage and Transportation charges for taking all dismantled equipments from site to store and new equipments at site including charges of heavy labour etc. as per requirement.
Installation and Fitting of above Pumps & Motors on the Base-Frame/Foundation. The job also includes installation & fixing of Valves, pipes, Bends, Reducers, Flanges etc. of both side (suction & delivery side) including primer & paint on complete equipments as per the site requirement & proper-alignment of pump-sets after taking all safety precaution arrangements, all Tools & Tackles etc including painting of all E&M equipments. The work shall be completed on turn-key basis and job also includes testing of Pump-sets on full load condition as per site requirement.
CHANDERA BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .