Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83,220Accepted-AOC 223 3 S V ROAD RAMKRISHNAPALLY BARASAT DIST NORTH 24 PARGANAS PIN 700124 | BARASAT | NORTH 24 PARGANAS | WEST BENGAL | 700124 | L1 | Accepted-AOC Stands Lowest | |
| 2 | L2₹1.1 L+₹29,038 (34.9%)Rejected-AOC 32A RANI HARSHAMUKHI ROAD KOLKATA 700002 | KOLKATA | KOLKATA | WEST BENGAL | 700002 | L2 | Rejected-AOC Stands 2nd Lowest | |
| 3 | L3₹1.2 L+₹38,486 (46.2%)Rejected-Finance 19B PANKAJINI CHATTERJEE ROAD CHARU MARKET KOLKATA 700 033 | KOLKATA | KOLKATA | WEST BENGAL | 700033 | L3 | Rejected-Finance Stands 3rd Lowest | |
| 4 | Rejected-Technical 118 A CHITTARANJAN AVENUE KOLKATA 700073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | - | Rejected-Technical TECHNICALLY NOT QUALIFIED |
Tender Value
Refer Docs
EMD Value
₹2,313
Closing Date
12 Jul 2022, 1:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Office of the Executive Engineer, Purba Medinipur Electrical Division, P.W.Dte, Tamluk, Hospital More
Electrical Installation work for District Statistics Office , Bureau of Applied Economics and Statistics at 2nd floor, Old Collectorate Building, Tamluk, Purba Medinipur----SITC of FDA system.
2022_WBPWD_386847_1
WBPWD/EE/PMED/eNIQ-12/22-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Tamluk
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,313
Tamluk
26 Aug 2022
24 Jun 2022
14 Jul 2022
24 Jun 2022
12 Jul 2022
29 Jun 2022
28 Jun 2022
SITC of 2 Zone Conventional Main Fire Alarm Control Panel complies with UL/ LPCB approved, along with 2 nos 12V, 7AH Battery, Battery Charger and all accessories. (Make : System Sensor / GST / Eaton/Morley)
SITC of Conventional type Multicriteria detector complies with UL/ LPCB approved with mounting base and all other required accessories. (Make : System Sensor / GST / Eaton/Morley)
SITC of Manual call Point Operates on 24DC with all accessories . (Make : System Sensor / GST / Eaton/Morley)
SITC of Conventional Hooter Cum Strobe, Strobe Light Should be 90cD flashing rated, along with All Fittings as per requirement. (Make : System Sensor / GST / Eaton/Morley)
SITC of Conventional type Response Indicator and all other required accessories (Make : System Sensor / GST / Eaton/Morley)
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (for Zone Wiring and 24V DC Supply to Hooter CumStrobe) (Make. Finolex/Havells/ RR Kable/Polycab ) with 20 mm NB PVC rigid conduit pipe (Make: Precision /AKG/ATUL /VIP/ Universal /BEC/Polycab) on the surface of the wall.
SITC of 24V DC 10 amps Power Supply for Strobe Cum Hooter .
NOTE : The Fire Alarm system shall comply with latest requirements of -- 1. IS 2189 2. National Fire Protection Association (NFPA) Standards. 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm & Signaling Code 5. Local Statutory Regulations 6. Manufacturer Recommendation.
TESTS: 1.The system shall be tested and commissioned by a qualified competent,trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done.
Terms and condition 1. The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. 2. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
NRD Global
BALAJI FIRE PROTECTION SYSTEMS
technical_756930.pdf
PDF • 0.23 MB
techsummary_756930.pdf
PDF • 0.02 MB
finance_756930.pdf
PDF • 0.27 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_756930.pdf
PDF • 0.30 MB
FWO.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .