Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.4 L+₹16,188 (0.89%)Rejected-Finance | L2 | Rejected-Finance L1 Being accepted | |
| 3 | L3₹18.4 L+₹23,701 (1.30%)Rejected-Finance | L3 | Rejected-Finance L1 Being accepted | |
| 4 | L4₹18.6 L+₹35,978 (1.98%)Rejected-Finance | L4 | Rejected-Finance L1 Being accepted | |
| 5 | L5₹18.6 L+₹36,004 (1.98%)Rejected-Finance | L5 | Rejected-Finance L1 Being accepted |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
30 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 867 EWS
GE 867 EWS C/O 99 APO PIN 913867
REPAIRS TO GEYSERS, EXHAUST FANS, COOLING APPLIANCES AND CONNECTED ALLIED WORKS AT KALIMPONG UNDER GE 867 EWS
2021_MES_466736_1
CA NO GE / 867 / TOKEN / 39 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Kalimpong
refer tender documents
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹34,000
Yes
18 Sept 2021
10 Aug 2021
31 Aug 2021
10 Aug 2021
30 Aug 2021
25 Aug 2021
10 Aug 2021 - 16 Aug 2021
60 days
Amount
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping, medium grade of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 1.5 Sq mm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one light /fan point controlled by one switch/one bell / buzzer point controlled by one bell push/one 3 / 5 -pin switch socket outlet 5 amps on independent board including taking down existing unserviceable point wiring including switches, sockets, regulators, ceiling roses, terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 2.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping, medium grade of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 2.5 Sqmm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one 5 / 6 -pin switch socket outlet 15 amps on independent board including taking down existing unserviceable point wiring including switches, sockets, regulators, ceiling roses, terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge. Make for Item No. 1 & 2 Cable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor Casing&Caping: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza
S&F in repairs switch piano, flush button, single pole, 5 amps, one way complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs switch socket combination 2 – in – one 6 Pin , 5 / 15 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs ceiling rose 3 terminal /PVC/Polycarnonate, isolated body complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 3 to 5: (i) Anchor (ii) Plaza, (iii) Havells (Crabtree) (iv) ABB (v) Shalabh
S&F sheet metal AC earth plug and socket of 3 pin with neutral with MCB SP 20 Amps 240 Volts including taking down existing unserviceable fitting complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosure DB SPN 4 way 240 V with 200 Amp rated bus bar, powder coated, double door including taking down old unserviceable DB complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosure DB SPN 8 way 240 V with 200 Amp rated bus bar, powder coated double door including taking down old unserviceable DB complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SPN 32 Amps, 10 KA breaking capacity, 240 volts, 50 Hz including taking down old unserviceable MCB complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SP 6 to 32 Amps, 10 KA breaking capacity, 240 volts, 50 Hz including taking down old unserviceable MCB complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 6 to 10: Legrand / Siemens/Schinder/L&T.
M&L for sub main wiring complete with 2 runs of 6 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor and drawing through and including non metalic rigid PVC casing & caping of 25mm size fixed on wall/ceiling and connecting terminal ends including provision of 1 run of 6 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor as earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring and making good disturbed surfaces complete all as directed by Engr-in-charge. Note: 2 runs of 6 Sqmm and one run of 6 Sqmm and one run of Casing&Caping shall be measured as one unit length.
M&L for sub main wiring complete with 2 runs of 4 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor and drawing through and including non metalic rigid PVC casing & caping of 25mm size fixed on wall/ceiling and connecting terminal ends including provision of 1 run of 4 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor as earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring and making good disturbed surfaces complete all as directed by Engr-in-charge. Note: 2 runs of 4 Sqmm and one run of 4 Sqmm and one run of Casing&Caping shall be measured as one unit length. Make for Item No. 11&12 Cable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor Casing&Caping: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza
Taking down carefully electric storage type water heater (Geysers) of any make and any capacity from its mounting place opening for inspection compete including back plate, heating element, inner copper tank etc., de-scaling back plate and heating element by cleaning with Sulfuric acid/ de-scaling compound and re-assembling of Geysers after repairs carrying out and re-fixing in same position (Replaced items such as spares measured and paid separately under relevent items) including making good to disturbed portin of walls with CM (1:3) or PCC (1:2:4 Type B1) and plastering the wall surfaces with CM 1:6 and replacement of old nuts, bolts and rubber gasket etc., complete all as specified and as directed by the Engineer-in Charge. Note :- Any type of rubber gasket , rubber washer, screws , insulating tape required shall be deemed to be included in the quoted rate.
All as per item No. 13 herein before but for descaling / cleaning the inner tank including denting and brazing the leakage joints / points till the leakage stops including carrying out minor repair of outer body surface, bottom and top cover complete all as specified and as directed by Engineer-in-charge. Note :- Any damage caused during the process of cleaning the geysers shall be made good by contractor at no extra cost department.
Supply & Fix in repairs 2 KW capacity Heating Element, Push/ Screw type with triangle cup/'O' ring including making electrical connection complete all as directed by Engineer-in-Charge.
Supply & Fix in repairs 1.5 KW capacity Heating Element, Push/ Screw type with triangle cup/'O' ring including making electrical connection complete all as directed by Engineer-in-Charge. Make for Item No. 15&16: Bajaj/Venus/Racold/Havells/Crompton/Power pack or equivalent as approved by GE
Supply & Fix in repairs Thermostat switch auto cut type for geysers 25/ 50 Ltr capacities including making connection complete all as directed by Engineer-in-Charge.
Supply & Fix in repair glass wool for insulation of geyser 25/50 Ltrs capacity and any make all as directed by Engineer-in-Charge.
Supply and fixing in replacement indicator lamp round /rectangular and making electric connections (Red/Green) 220 Volts AC as per site requirement suitable for geysers complete all as directed by Engineer-in-Charge.
Supply and fixing in replacement safety valve spring locked type with inlet coupling all as specified and directed by Engineer-in-Charge.
S&F in replacement plug top 15 Amps 240 Volts complete all as specififed and directed by Engineer-in-Charge.
S&F in replacement fuseable plug suitable for any capacity geyser complete all as specififed and directed by Engineer-in-Charge.
S& F in replacement 2.5 Sqmm 3 core PVC insulated unsheathed stranded copper wire complete all as specified and directed by Engineer-in-Charge. MAKE:- ANCHOR/FINOLEX/PLAZA/ HAVELLS/ HPL/ POLYCAB
Dismantling of exhaust fans of 300mm sweep AC single phase 230/240 volts of any make / model except old vintage, dismantling stator, rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish, cleaning of bearing housing and shaft, replacing spares such as split pins, blade screws etc., as required and reassebling and refixing complete all as specified and directed by Engineer-in-Charge. NOTE: Supply only bearings and capacitors shall be paid seperately under relevent Items.
All as per item No 24 here-in-before but 200/225/250mm sweep all as specified and directed by Engineer-in-Charge.
All as per item No 24 here-in-before but 150mm sweep all as specified and directed by Engineer-in-Charge.
Supply only ball bearing suitable for exhaust fan of any sweep anf any make/ model complete all as directed by Engineer-in-Charge. Make:- NBC/ TATA/ SKF
Supply only capacitor of 2.5 mfd complete all as directed by Engineer-in-Charge. Make:- CAPCO/ TIBCON/ CROMPTON
S&F heavy duty stainless steel inner tank suitable for 25 Ltrs capacity Geyser having high pressure bearing capacity including taking down existing copper / steel inner tank complete all as specified and as directed by Engineer-in-charge.
S&F heavy duty stainless steel inner tank suitable for 50 Ltrs capacity Geyser having high pressure bearing capacity including taking down existing copper / steel inner tank complete all as specified and as directed by Engineer-in-charge.
S&F in replacement top cover made of MS sheet 18 SWG duly painted with two coats of super enamel paint by spray painting suitable for 25 Ltrs geysers complete all as specified and as directed by Engineer-in-charge.
S&F in replacement top cover made of MS sheet 18 SWG duly painted with two coats of super enamel paint by spray painting suitable for 50 Ltrs geysers complete all as specified and as directed by Engineer-in-charge.
S&F in replacement bottom cover made of MS sheet 18 SWG duly painted with two coats of super enamel paint by spray painting suitable for 25 Ltrs geysers complete all as specified and as directed by Engineer-in-charge.
S&F in replacement bottom cover made of MS sheet 18 SWG duly painted with two coats of super enamel paint by spray painting suitable for 50 Ltrs geysers complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of outer body fabricated of 1.6 mm MS Sheet for geysers of 25 Ltrs capacity duly painted with spray point with clamps 02 Nos of with necessary nut bolts complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of outer body fabricated of 1.6 mm MS Sheet for geysers of 50 Ltrs capacity duly painted with spray point with clamps 02 Nos of with necessary nut bolts complete all as specified and as directed by Engineer-in-charge.
Supply only of geyser assembly suitable for 25 ltr capacity ISI marked including dismantiling of old unserviceable geyser assembly complete all as specified and directed by Engineer-in-Charge.
Supply only of geyser assembly suitable for 50 ltr capacity ISI marked including dismantiling of old unserviceable geyser assembly complete all as specified and directed by Engineer-in-Charge.
Taking down exhaust fan of any size and cleaning all type dust, oil stains etc., painting with one coat of syntatic enamemel paint by spraying including writing SM No. Etc., and refixing properly in the same location complete all as specified and directed by Engineer-in-Charge.
Fixing only exhaust fan of any type sweep and connecting including provision of 3 core flexible cable of 1.5 sqmm from ceiling rose to fan including all necessary fixing arrangements including taking dowm existing exhast fan and removing to MES store yard complete all as specified and directed by Engineer-in-Charge. NOTE: Exhast fan shall be issued under Schedule B "Free for fixing only".
Supply and fixing in replacement PVC connection heavy duty with brass /PTMT nuts of reqd |ength not exceeding 300 mm with rubber/ PVC washer suitable for 15 mm bore GI pipe for cold water complete all as specified & directed by Engineer-in-Charge. Make:- PRAYAG/POLYTUFF or equivalent as approved by GE.
Supply & fixing in replacement 15mm dia 300mm long chromium plated copper pipe connection (Heavy Duty) with two numbers brass adopters for fixing one end at geyser & other end at water outlet point for hot water complete all as specified and directed by Engineer-in-Charge.
Taking down carefully electric storage type water heater (Geysers) of any make and any capacity from its mounting place cleaning all type dust, stains etc, painting with one coat of synthetic enamel paint by spraying and refixing properly in the same location complete all as specified and directed by Engineer-in-Charge
M & L for shifting of exhuast fan from one place to another including making hole at new place and filling hole at old place including all necessary electric connection, brick work, plastering and 2 coat of painting of size 150, 200, 250 and 300 mm dia all as specified and as directed by Engineer-in-Charge.
Taking out for maintenance, Servicing and overhauling indoor unit of various capacity split type AC including cleaning of cooling coil, blower motor, fan blades, water tray, air filter, replacement of minor parts such as screws, nuts, bolts etc., and wiring kit refixing complete all as directed by Engineer-in-Chare.
Taking out for repairs outdoor unit of various capacity split type AC including cleaning of Air filter checking of wiring and rectification of defects including necessary dismantling and taking out for reparing and refixing and replacing spares as required complete all as directed by Engineer-in-Chare. Note:- Accessories / spares/ Gas charging required for replacement shall be measured and paid separately under respective items of schedule ‘A’ as supply only.
Supply only Starting relay suitable for split AC.
Supply only Running capcitor 45 mfd + 06 mfd suitable for split AC.
Supply only Condenser fan blade suitable for split AC.
Supply only Starting capacitor 100/120 mfd suitable for split AC.
Supply only sealed unit compressor (replaced with original company repaired) for Capacity 1.5 Ton to 2 Ton suitable for split AC.
Gas Charging R22 to split AC of any capacity.
Supply only Drain pipe suitable for split AC.
Supply only Blower motor suitable for split AC.
Dismantling the blower motor of any capacity split AC, cleaning completely all the parts, taken out burnt out winding and fresh winding with super enamelled copper wire of existing size including varnishing, re-assembling of the motor by repacement of ball bearings including painting with two coats of synthetic enamel paint of approved colour and testing complete all as specified and as directed by Engineer-in-charge
Transporting of defective refrigerator of any make and capacity from MES store yard ro Contractor workshop for carrying out necessary repair and rectification of defects including necessary dismantling and taking out for reparing and refixing and replacing spares as required including bringing back to MES storeyard/ directed location after repair and testing complete all as directed by Engineer-in-Chare. . Note:- Accessories / spares/ Gas charging required for replacement shall be measured and paid separately under respective items of schedule ‘A’ as supply only.
Supply only Starting capacitor suitable for 190 to 230/250 to 345 Ltr capacity refrigerator.
Supply only Termostat switch suitable for 190 to 230/250 to 345 Ltr capacity refrigerator.
Supply only Freezer chamber (Evaporator coil) suitable for 230 to 345 Ltr capacity refrigerator.
Supply only Compressor suitable for 190 to 230/250 to 345 Ltr capacity refrigerator.
Charging of refrigerant gas R-134A/R22 for refrigerator/deep freezer.
Transporting of defective Deep freezer of any make and capacity from MES store yard ro Contractor workshop for carrying out necessary repair and rectification of defects including necessary dismantling and taking out for reparing and refixing and replacing spares as required including bringing back to MES storeyard/ directed location after repair and testing complete all as directed by Engineer-in-Charge. . Note:- Accessories / spares/ Gas charging required for replacement shall be measured and paid separately under respective items of schedule ‘A’ as supply only.
Supply only Capacitor 3 mfd suitable for 150 to 205/300 to 335 Ltr capacity deep freezer
Supply only Starting capacitor suitable for 150 to 205/300 to 335 Ltr capacity deep freezer
Supply only Filter strainer suitable for 150 to 205/300 to 335 Ltr capacity deep freezer
Supply only Expansion valve suitable for 150 to 205/300 to 335 Ltr capacity deep freezer
Supply only Compressor suitable for 150 to 205/300 to 335 Ltr capacity deep freezer
Sub Total of Schedule 'A'
Schedule of Credit (Minus) Rs. 23,756.00 B/F from Ser page No. 28 NOTE: Bidder shall insert credit amount as rate Rs. 23,756.00 in Green field under Col-M. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender.
Sub Total of Schedule of Credit
PRASAD PRADHAN AND SON
ANTHONY PRADHAN
RAJU TAMANG
G K SUTHAR
SANJAY MITTAL
GEETA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .