Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹45.8 L+₹3.8 L (9.07%)Rejected-Finance 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹48.6 L+₹6.6 L (15.7%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹50.3 L+₹8.4 L (20.0%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
12 Nov 2022, 6:00 pmClosed
SHRI PRAVEEN KUMAR, IDSE
GE NDA Khadakwasla
REPAIR, SERVICING AND PERIODICAL MAINT OF PACKAGE TYPE AND CENTRAL AC PLANTS WATER COOLER CASSETTE TYPE AC WINDOW TYPE AC SPLIT TYPE AC REFRIGERATOR DEEP FREEZER COLD ROOM ICE MAKING MACHINE AND WATER CHILLER PLANT INCL ALLIED WORKS AT NDA KHADAKWASL
2022_MES_553298_1
8645/E8
Open Tender
Civil Works
Works
330 days
GE NDA Khadakwasla
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NDA Khadakwasla
₹98,000
Yes
23 Dec 2022
21 Sept 2022
14 Nov 2022
22 Sept 2022
12 Nov 2022
1 Oct 2022
23 Sept 2022 - 30 Sept 2022
Amount
Periodical Servicing of water cooler/ Split AC / Window AC /Cassatte AC/ Package AC/ Refrigerator/ Deep Freezer of any capacity & make installed at various location of NDA in situ as and when due and making cooling appliences servicible in all respect with replacement of any minor parts if found U/S and obtained signature of users & JE E/M of MES all as specified and directed. The Periodical Services comprises the following and all as directed:- (a) Servicing of cooling appliences unit outer and inner side complete with vaccume cleaner, soap water, caustic soda, colin etc of any capacity any make and any type in situ by replacing unserviceable parts from the machine checking/repairs to sensor unit and cooling effect of cooling appliences for proper functioning complete all as specified and as directed. (b) Drainout water from inner tank of cooling applience and cleaning the tank thoroughly. (c ) Servicing & cleaning of condensing unit/all filters, dryers complete with vaccume clenear, soap water, castic soda, colin etc of any capacity , any make and any type in situ including, leak testing, brazing the suction / discharge tubes as directed. (d) Any other required Scheduled servicing as recommended by OEM. Note: (i) Contractors rep will report to JE E/M / Engr-in-charge as and when called upon for scheduled servicing of cooling Appliences with all necessary tool and plant. (ii) All job work recieved on complaint slip will be Serviced then obtain signature of user for satisfactorily completion of Job and then returned to JE E/M / Engr-in-charge on same day of receipt. (iii) Incase of delay in attending the said Job for more than 2 days, the contractor shall be liable to pay the penalty of Rs 500/ per day on account of delay. (iv) Parts required for replacement shall be measured and paid seperately under appropriate items.
Supply and fix in repair/replacement Blower motor with blade, single phase, 230V 50Hz, RPM - 1325, suitable for 40/80ltr, 60/80 Ltr water cooler complete all as directed.
Supply and fix in repair/replacement blower motor with blade, single phase, 230V 50Hz, suitable for 120/150 Ltr water cooler complete all as directed.
Supply and fix in repair/replacement Running capacitor 8MFD/suitable for 40/80 or 60/120 ltr water cooler, Plastic casing , Copper wire terminal complete all as directed.
Supply and fix in repair/replacement Running capacitor 15MFD/suitable for 40/80 or 60/120 ltr water cooler, Plastic casing , Copper wire terminal complete all as directed.
Supply and fix in repair/replacement Starting capacitor 40/60 MFD suitable for 60/120 to 150 ltr water cooler Plastic casing , Copper wire terminal complete all as directed.
Supply and fix in repair/replacement thermostat switch as in repair suitable for water cooler 40/80ltr, 60/120 to 150 Ltr complete all as directed.
Supply and fix in repair/replacement Thermostat suitable for water cooler of capacity 40 to 300 ltrs for 230V 50HZ AC all as specified and directed
M&L for Brazing of copper tubing after leakage test of Evaporator/ Condensing coil of water cooler of any cap all as directed.
Supply and fix for PVC connections heavy duty 15 mm size with PTMT nuts of length 900 mm long complete all as directed.
Supply and fix of wire heater for cold room as per existing length and size for defreezing of blocked tubing all as directed.
M & L for Rigid Non-metalic PVC conduit 40mm dia medium grade with all fittings and fixing accessories such as coupler, lock nut, saddle, pipe hook and laid on floor (For wash out line).
Supply and fix in repairs single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as directed.
Supply and fix single pole and neutral enclosure with two pin and earth plug and socket complete with one double pole MCB 20 Amp complete all as directed.
Supply and fix stop cock 15 mm cast copper alloy, screwed down, high pressure with crutch or butterfly handle, external/internal threads,screwed both ends for GI pipe complete all as directed.
Supply and fix push cock as in repair chromium plated 15 mm (Inner/outer thread) of any type as directed and to suit with existing water cooler
Supply and fix in repair/replacement Float valve 15mm dia high Pressure with Polythene float and flynut complete screwed for iron pipe rod upto 6 " length PVC ball with all connecting items as in repair complete all as directed.
Supply and fix PTMP extension nipple, min 15mm dia and 25mm length as in repair complete all as directed.
M & L for PTMP extension flange, min 15mm dia and 25mm length as in repair complete all as directed.
Supply and fix in repair/replacement Over load protector device for 120/150 Ltr Cap. Water Cooler complete all as directed.
Supply and fix in repair/replacement Over load protect device for 40/80 Lts Cap. Water cooler complete all as directed.
Supply and fix in repair/replacement compressor sealed unit type KCJ461/KCJ467/2612/KCE-443/444 suitable for 40/80 & 60/120 ltr water coolers including charging of Refrigerant if required complete all as directed.
Supply and fix in repair/replacement Compressor sealed unit type KCJ513/HR-13 suitable for120 or 150 ltr water coolers including charging of Refrigerant complete all as directed.
Supply and fix in repair/replacement rotary Compressor sealed unit type KCJ513 HAE suitable for 170/400 water coolers including charging of Refrigerant complete all as directed.
Supply and fix box type relay cat no 85001/02 suitable for 40/80/120/150ltr water cooler as in repair complete all as directed.
Supply and fix of Mild steel/Stainless steel legs with nut bolts/duly welded for water cooler of any size and make as per site requirment complete all as directed
Supply and fix of Stainless steel waste water collection tray,class-1, min 1.2mm gauge, 500mm to 600mm length, 150mm width flat and arc type as per existing size suitable for with all necessary drain pipe connecting items i.e screw/nut bolt arc/gas welding reqd etc for water cooler of any capacity and make as per site requirement complete all as directed.
Supply and fix of plug top 15A, 3 Pin for water cooler of any capacity and make as per site requirement complete all as directed.
Supply and fix of modular switch socket combination outlet ,6 pin, 16 amp flush type 3 module incl PVC back boxwith cover platecomplete all as specified and directed.
Supply and fix & fix in repairs voltage stablizer for automatic opration. single phase naturally air cooled indoor type & designed for Input variation beetween 170V to 250 V with output voltage stablized at 230 V with accuracy of (± ) 2.5% and of capacity 4 KVA.wall mounted.
M&L for sub main wiring 3x2.5 sqmm ( phase , neutral and earth) PVC insulated (heavy duty) 1100 volts grade, FRLS, with multi stranded copper conductor conforming to IS 694 in & including PVC casing caping of suitable size not less than 25mm ( 3 run of 2.5 sqmm cable and one run of PVC casing caping will be measured as one unit) including taking down of Old U/S wiring (from distribution board to metal clad switch socket point near water cooler) all as specified and directed.
Supply and fix & fix three core 1.5 sqmm copper conductor cable lead of not less than 1.5 mtr including 5/15A plug top attached with one end and other end solenoid with thimble suitable for compressor any size.
M & L for prepartion of old painted metal surfaces of any description, with scrapping removing, dusting, and applying one coat red oxide primer and two coats synthetic enamled paint as per existing existing colour with spray gun of different tint as appoved by Engr-in-Charge (external surface of water cooler capacity 60 to 120 ltr/ completer all as specified and directed
Supply and fixof compressor suitable to fixed with outdoor unit of Carrier Make Cassete type Air conditioner of capacity 4.0TR. Make of Compressor Copeland Scroll complete all as directed.
Supply and fix in repair/replacement electronic Sensor unit (PCB) with RC suitable for 4.0TR Casete type AC complete all as directed.
Supply and fix in repair/replacement blower motor for indoor unit, single phase, 50 Hz, 220 Volts 820RPM,0.90A 6P ,suitable for Carrier Make 4.0 TR Casete type Air conditioner complete all as directed.
Supply and fix and fix in repairs fan motor for out door unit with fan blade, single phase 230 Volts 1050 RPM, 1/6 HP,suitable for outdoor unit of Carrier Make 4.0 TR Cassete type Air conditioner complete all as directed.
Supply and fix and fix in repairs fan blade made of HD PVC suitable for Carrier make 4.0 Ton outdoor unit including lock nut complete all as directed.
Supply and fix Air brake power contactor 3 phase AC 50 Hz 415V, 15Amps (as per existing) suitable for 4.0 TR Cassete type Air Conditioner complete all as directed.
Supply and fix water condenser drain pump assy suitable for carrier make casset type indoor unit (as per existing) complete all as directed.
Supply and fix sensor unit for water pump of carrier make casset type AC indoor unit (as per existing) complete all as directed.
Taking out existing unserviceable Street light fittings from wall/ceiling and Supply and fix and fix in repairs new LED 40 W street light fitting IP-66 with required size GI bracket and fixed on wall /ceiling with necessary MS clamps, bolts, nuts etc required for proper fixing complete all as directed.
M & L for prepartion of old painted metal surfaces of any description, with scrapping removing, dusting, and applying one coat red oxide primer and two coats synthetic enamled paint as per existing colour with spray gun of different tint as appoved by Engr-in-Charge (External surfaces of pipe, shell, tube type condensser any size ) complete all as specified and directed
Taking out existing unserviceable 'V' belt of compressor and Supply and fix and fix in repairs new 'V' belt Make Fenner type C-3000/ 116 or equivalent make as approved.
Taking out existing unserviceable 'V' belt of AHU blower and Supply and fix and fix in repairs new 'V' belt Make Fenner type B- 1882/LP/B70 or equivalent make as approved.
Dismantling of compressor of Central typy Air conditioner of capacity upto 55TR installed at Hubibullah Hall (Make :KIRLOSKAR , Model : AC870) and over haulling the same by replacing unserviceable / worn out parts including necessory machine work to the crank shaft, discharge valve plate etc for proper repair.Servicing of Oil pump by replacing oil pump repair kit. Reassembling the compressor unit with existing serviceable parts and new parts given here in after(as Supply and fix only), rectifying other deffects if any, Charging of Refrigerant gas (R-22) and Compressor Oil upto the required level to achive desired cooling effect, Connecting the compressor with the lines and testing commissioning complete all as directed. Notes: ii) Parts required for replacement shall be measured and paid seperately. iii) Unit rate includs retrieving existing refrigerant & Compressure oil from the plant, preserve carefully and re use the same after overhauling of Compressure. iv) Additional quantity of Refrigerant Gas & compressure oil required for the job for satisfactory running of plant shall be measured and paid seperately. v) Any Minor repair or small parts (costing up to Rs 1000/) those are not covered in item above shall to be done by the contractor and rate for the same is included with the unit rate.
Cleaning of shell and tube type condenser of Central type Air conditioner 55 TR Capacity (Installed at Hubibullah Hall ) with dilute hydrochloric acid and brushing to internal portion of condenser includin replacement of gasket,testing after cleaning complete all as directed.
Supply and fix Piston assy cast Aluminium including Piston rings, scraper rings & Seeger rings complete of compressor
Supply and fix Piston sleeves of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and fix Plunger for unloading mechanism of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and fix Piston pin of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and fix bush for Piston pin of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and fix Half section of bearing of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and fix Suction and discharge rid with valve plate of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and fix set of shaft seal complete of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and fix Gasket set complete of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and fix Oil heater complete of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and fix oil pump repair kit complete of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and fix connecting rod of compressor Make Kirloskar Model : AC 870 complete all as directed.
M&L for Refrigerant Gas Leakage Testing with Nitrogen Gas Leak test including all equipememt and necessary brazing and replacement arrengement for arresting leakage and Charging the required quantity of similar Gas as per existing refrigerant and reconfirmation of leakage removal for various cooling appliences at different places all as directed.
Supply and fill compressor oil of suitable grade POE complete all as directed
Taking out existing unserviceable 'V' belt of compressor and Supply and fix and fix in repairs new 'V' belt Make Fenner type SPC-4000 or equivalent make as approved.
Taking out existing unserviceable Pressure control device and Supply and fix and fix in repairs new Pressure control device(High pressure cut off with indicator) type MP-5 complete all as directed.
Taking out existing unserviceable Pressure control device and Supply and fix and fix in repairs new Pressure control device (low pressure cut off with indicator) type MP-1, complete all as directed.
Taking out existing unserviceable Pressure control device and Supply and fix and fix in repairs new Pressure control device(High pressure cut off with indicator) type MP-15 complete all as directed.
Taking out existing unserviceable Oil Pressure control device and Supply and fix and fix in repairs new Oil Pressure control device (Oil pressure cut off with indicator) type MP-35 complete all as directed.
Taking out existing unserviceable Oil Pressure control device and Supply and fix and fix in repairs new Oil Pressure control device (Oil pressure cut off with indicator) type MP-55 complete all as directed.
Taking out existing unserviceable Loading/unpoading soloniod Valve three way 1/4BSP, 22 bar pressure, 100 degree C, 230 Volt and Supply and fix and fix in repairs new Loading/unpoading soloniod Valve three way 1/4BSP, 22 bar pressure, 100 degree C, 230 Volt complete all as directed.
Taking out existing unserviceable High Pressure gauge and Supply and fix in repairs new high Pressure gauge 0-25 Kg/cm square as per existing size complete all as directed.
Taking out existing unserviceable Low Pressure gauge and Supply and fix in repairs new Low Pressure compound gauge 0-16/0-(-760) Kg/cm square suitable for R-22 as per existing size complete all as directed.
Taking out existing unserviceable monometer gauge and Supply and fix in repairs new Monometer water suction gauge 0-10.6 Kg/cm square as per existing size complete all as directed.
Taking out existing unserviceable monometer gauge and Supply and fix in repairs new Monometer water Discharge gauge 0-21 Kg/cm square as per existing size complete all as directed.
Taking out existing unserviceable water pressure switch and Supply and fix in repairs new water pressure switch (IPS) for oil air water stem as per existing size complete all as directed.
Taking out existing unserviceable liquid soloniod valve and Supply and fix in repairs new liquid solenoid valve/pilot solenoid valve MAG-2, 208-240V, 50-60 Cy, 15W as per existing size complete all as directed.
Taking out existing unserviceable filter dryer 1/4 inch outer thread, C-032F and fix of new filter dryer 1/4 inch outer thread, C-032F as per existing size complete all as directed.
Dismentiling carefully all water connections, decoping of pumps from electric motor taking out from foundation and transporting pump body to workshop for necessary machining works as directed and reqd and reinstalling the pump to its original position and commissioning etc instaled at Habbibullah hall/ATT Plant for diffrent capacity
S&F in replacement coupling made of MS cast block suitable for existing pump & motor of make Kirloskar model suitable for 15HP/10 HP including nut, bolts & rubber bushings etc complete.
Repair and rewinding of electric induction motor by using super enamelled copper wire (Class-F) as per existing gauge, heating and varnishing complete. The repair work involves taking out burntout winding coiles from stator, cleaning of slots throughly , removing all dirt grease an other unwanted particle, replacmement of UNSV parts where reqd (as directed) capacity of motor 75/50 HP complete all as direced. NOTE : (i) Unit rate is deem to be included for taking out otor from its position, shifting of motor from pump housed to workshop, getting back to plant house, reinstalling at site, connecting up, couple with the pump and testing complete, retrieved windg wire will be the contractors property and necessary credit amount is deemed to be included in the quoted rate, hence no credit has been considered in credit schedule. (ii) Spare parts other than rewinding job required for replacment shall be measured and paid speeratly as Supply and fix only.
Repair and rewinding of electric induction motor by using super enamelled copper wire (Class-F) as per existing gauge, heating and varnishing complete. The repair work involves taking out burntout winding coiles from stator, cleaning of slots throughly , removing all dirt grease an other unwanted particle, replacmement of UNSV parts where reqd (as directed) capacity of motor 20/15/10 HP complete all as direced. NOTE : (i) Unit rate is deem to be included for taking out otor from its position, shifting of motor from pump housed to workshop, getting back to plant house, reinstalling at site, connecting up, couple with the pump and testing complete, retrieved windg wire will be the contractors property and necessary credit amount is deemed to be included in the quoted rate, hence no credit has been considered in credit schedule. (ii) Spare parts other than rewinding job required for replacment shall be measured and paid speeratly as Supply and fix only.
Dismantling/opening the pump part by part without damaging any other parts , descaling and cleaning of all parts for inspection and finding serviceability/unserviceability of the parts and carefully assembling of pumps by using existing serviceable parts including replacement of PTFE gasket packing greasing all bearings, bushing,etc and replaement of unserviceable parts as directed installed at Habbiullah Hall/ATT Plant 10/15/20 HP ( Cooling water pump/ Blower motor of AC plant ), thoroughly, complete refix at their existing position reinstall the pumpr at existing position, complete all electric connections and testing complete all as directed. .
Preventive maintenanc of AC, 3 Phase induction motor of capacity 20/15 HP by dismantiling the motor completely without damaging any parts and applying air dry insulating varnish, of appropriate grade (make doctor bake/appex), cleaning bearing refix at their existing position with bearing grease, checking terminals and thimbles tighting the all terminal joints replace terminal plates where necessary/reinstall the motor at existing position, connecting electric connections and testing complete all as directed.
Preventive maintenanc of AC, 3 Phase induction motor of capacity 7.5/10 HP by dismantiling the motor completely without damaging any parts and applying air dry insulating varnish, of appropriate grade (make doctor bake/appex), cleaning bearing refix at their existing position with bearing grease, checking terminals and thimbles tighting the all terminal joints replace terminal plates where necessary/reinstall the motor at existing position, connecting electric connections and testing complete all as directed.
Taking out existing burnt contactor from panel and Supply and fix connecting 3 Pole power contactor, 415 Volt, AC 3 Phase,AC3 rating 45 Amps, AC 3 Phase, AC1 rating 50 Amps, with 400/230 Volt coil,(as per existing ) Make L&T / Telemecaniqee /C &S/BCH/Schneider.( Power contactors may be of different make as fitted in existing pannel so that the contactors can be accommodated in its position) complete all as directed.
Taking out existing burnt contactor from panel and Supply and fix connecting 3 Pole power contactor, 415 Volt, AC 3 Phase, AC3 rating 18 Amps AC1 rating 20 to 32 Amps, with 400/230 Volt coil,(as per existing ) Make L&T / Telemecaniqee /C &S/BCH/Schneider.( Power contactors may be of different make as fitted in existing pannel so that the contactors can be accommodated in its position) complete all as directed.
Taking out existing Thermal over load relay and Supply and fixing of new relay type AUR1 make Schneider or equivalent of L&T/ C&S/ L&T/BCH/Schneider/ Telemecaniqee.(Relays may be of different make as fitted in existing pannel so that the relays can be accommodated in its position) complete all as directed.
Taking out existing burnt Add on auxilary contact block from panel and Supply and fix,fix and connecting new Add on auxilary contact block with 2 NO + 2NC, front mounted ,415 Volt, Make C&S / L&T/BCH/ Telemecaniqee/ schneider.(Add on block may be of different make as fitted in existing so that theblocks can be accommodated in its position) complete all as directed.
Taking out existing burnt timer from panel and Supply and fix in repairs new Timer 0-30/60Sec pluse time 50-100 msec, 800 SD 2-230 selce,415 Volt, reqd for star delta Make L&T, C&S / BCH/ Telemecaniqee/ schneider.(Timer may be of different make as fitted in existing so that the timer can be accommodated in its position) complete all as directed.
Supply and fix in replacment of of Miniature circuit breaker tripple pole 415 volt, 25-63 Amps having rupturing capacity 10kA 'C' Series complete all as directed.
Cleaning of cooling coil fins and filters complete of AHU of 55 TR capacity installed Habibullah hall by caustic soda and Nylon brush as per direction of Engineer-in-charge and refix at their existing position
M&L for servicing the Air handling units capacity 40/55 TR, with and including cleaning complete units, sheet metal parts, blowing out the dust, chemical cleaning by spraying the organic based scale removing agent Vaniklin at the appropriate ratio till removal of complete dust & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across the coil, cleaning of expansion valve; greasing of blower motor, checking of electrical connection, cleaning of air filters,prefilters & fine filters box type with washable nylon filters media having 90% efficiency to control dust particles up to 10 microns fitted in aluminum framed with both side wire mesh of size 610x610x50mm of class EU-4 and for fine filters 99% efficiency to control dust particles up to 10 microns 610x610x500 mm EU-7 as per sample suitable for 55 TR AHU plant,greasing of blower motor,replacement of unserviceable bearings, water drain lines, renewal of rusted sheet metal screws, and testing & commissioning the unit all as specified and as directed.
M & L for taking out Exisitng damaged 250A MCCB 4Pole and Supply and fix and Fix New MCCB 4 Pole MCCB 250 A 50 Hz 415 V, with rupturing capacity 36 KA as specified and directed.
M&L for Demolition existing cement Concrete Blocks , taking down and refixing carefully of standing Cooling tower approx 750 Kgs and taking out all electric and Mechancial fittings of Cooling tower of airconditioning Plant machine carefully complete etc and make the surface clean, complete all as directed.
M&L for cement concrete (1:3:6) type C2 (Using 40mm grade stone aggregate) foundation/resting platform in foundation filling and mass concrete complete all as directed.
M &L for rendering 10 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) connected to galvanized Iron strip 25x 4mm by means of bolts, nuts and washers of galvanized iron or steel, GI light grade protection pipe 15mm dia, GI medium grade water pipe 20mm dia with funnel all as shown in electric plate No 3 of SSR-2020 pt-I and testing complete including earth work excavation in any type of strata /soil PCC 1:2:4 as in earthing pit, 50 mm PCC pit cover with 6mm iron handle attached , common salt charcoal all as specified including testing on complete. Note : GI Strip beyond 7.5 mtr shall be measured and paid for sperately.
M&L for Duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation 25 mm as specified and including the following:- (a) Cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Applying rubber based adhesive CPRX compound. (c) Sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) Securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
Supply and fix 10A Digital thermostat of dual mode, Temperature Regulating device of range from -50 degrees to 999 degree Centigrade of K type thermocouple,and alarm mode type required if it exceeds the set temperature value as specified.Model:ZFX-7016K
M&L for preparation of old painted surfaces of AC plant cooling water pump/condenser water pump sets up to 10 HP including base frame and condenser water pipe line from condenser to cooling tower including cooling tower frame by scrapping and removing rust, accumulated grease/dust etc and applying two coats of synthetic enamel paint over a coat of zinc chrome primer on rusted portion and marking machine numbers all as directed for central AC plant,.
S&F Pre-filter made up of GI sheet frame size 65x 25cm with Nylon wire mesh 10 Micron grade with efficiency more than 90% suitable of AHU of 55TR Cap Central AC Plant
Dismantling and taking out serviceable/ unservicable split type airconditioning machine/ Cold Room Machine/ Pakage type Machine carefully complete of capacity upto 4TR with outdoor unit, indoor unit, copper pipes, cables etc and depositing AC unit to MES store for repair and reinstall at site after carring out necesary repair work.
M & L for making holes by core cutting machine on stone/concrete / brick walls.Dia of hole not exc.50mm and thickness of wall 50cm to 70cm for entry of suction and discharge pipes of AC and making good distarbed surfaces with cement morted and finally finished with plaster of parise and painted the distrubed surfaces with existing type of paint and tint complete all as directed.
Supply and fix in replacement of Starting capacitor of 80-100 Mfd, AL Casing, Copper wire terminal suitable for 1.5 TR split AC.
Supply and fix in replacement of Starting capacitor of 100-120 Mfd, AL Casing, Copper wire terminal suitable for 2.0 TR split AC,
Supply and fix in replacement of rotary compressor suitable for 3.0 Ton split Air conditioner 3 phase, 415 volt and fixed in out door unit complete all as specified and as directed.
Supply and fix in compressor suitable for 2.0 Ton split Air conditioner working on R-22/R410/R404 refrigerant, single phase, 230 volt and fixed in out door unit complete all as specified and as directed.
Supply and fix in rotary compressor suitable for 1.5 Ton split Air conditioner working on R-22/R410/R404 refrigerant, single phase, 230 volt and fixed in out door unit complete all as specified and as directed
Supply and fix in four pole power contactor 25Amps, with standard coil voltage suitable for 3.0TR split Air conditioner complete all as directed.
Supply and fix in replacwement single pole contactor Type MR 25 Amps, with coil voltage 230 volts for spilt type AC 1.5/2.0 TR complete all as directed.
Supply and fix in replacement electronic auto sensor unit (PC card with all component) suitable for AC/DC Supply and fix of make LG/Sumsung/Carrier /Bluestar Make for Split AC 2.0/1.5/3.0 Ton capacity complete all as directed.
Supply and fix of air blower motor with shaft suitable for indoor unit of 1.5 TR split type AC of any approved make (as per existing make of AC) complete all as directed.
Supply and fix of air blower motor with shaft suitable for indoor unit of 2.0 TR split type AC of any approved make (as per existing make of AC) complete all as directed.
Supply and fix of fan motor with fan blade suitable for outdoor unit of 1.5 TR split type AC of any approved make (as per existing make of AC) complete all as directed.
Supply and fix of fan motor with fan blade suitable for outdoor unit of 2.0 TR split type AC of any approved make (as per existing make of AC) complete all as directed.
Supply and fix in replacement copper tube of suction line of split AC 1.5/2.0/3.0 TR 5/8", 3/8" dia including necessaring flearing/soldering and provn of flair nut for jointing complete all as directed
Supply and fix in replacement copper tube of suction line of split AC 1/4" dia including necessaring flearing/soldering and provn of flair nut for jointing complete all as directed.
M & L for providing insulation of copper pipes of split AC with 19 mm thick nitrile foam insulation tube and finally wraping with heatlon taps, binding with PVC tag complete all as directed.
Supply and fix of of Runing capacitor 45/4 Mfd, AL Casing, Lug terminal 440 volt, 50Hz for split or window type AC of capacity 2.0TR.
Supply and fix of of Runing capacitor 36/4 Mfd , AL Casing, Lug terminal 440 volt, 50Hz for split or window type AC of capacity 1.5TR.
Supply and fix of in replacement of box type relay suitable for window type AC. Make SRIRAM Model SR 1622 or Emerson.
Supply and fix of replacement thermostat suitable for window type AC 1.5/2.0 TR complete all as directed.
S&F PVC Insulated FR, PVC Round Sheathed, copper conductor flexible cable ,2.5 sqmm ,3 core, multi stranded, 1100V grade, conforming to IS 694 all as specified and directed
Supply and fix of universal/Strainer filter cum dryier suitable for 1.5/2.0 TR AC/Water cooler/Refrigerator.
Supply and fix of universal/Strainer filter cum dryier dcl 304 suitable for 3/4TR AC Cold Room
Supply and fix of blower motor with blade, single phase, 230V 1500 RPM, 1/5 HP, Suitable for 1.5/2.0 TR window type Air conditioner.
Supply and fix of in replacement of capacitor 4 MFD,Plastic casing , Copper wire terminal 230 volt, 50 Hz
Supply and fix in replacement electronic sensor unit (PCB) suitable for 1.5/2.0 TR window AC of any make as ordered.
Supply and fix of compressor hermetical sealed reciprocating type/Rotary type suitable for 1.5 Ton AC.
Supply and fix of compressor hermetical sealed reciprocating type/Rotary suitable for 2.0 Ton AC.
Supply and fix only thermostat suitable for 1.5 T/2T for Window AC suitable capacity for 230 V 50 HZ AC Supply and fix all as directed.
Supply and fix for cooling coil made out of copper tube of size as per existing coil capacity and specification suitable for 1.5 T/2T window AC of any make and type as per existing complete all as directed
Supply and fix only Remote control for AC as per sample of any make ,type capacity all as specified and directed
M &L for refixing only split AC indoor/outdoor unit complete with copper tubing of any type size and make for shifting at other place after making necessary opening in existing wall any type /thickness and fixing of AC with copper tubing and drain out pipline after necessary servicing complete all as specified and directed. Note:Transportation of AC is included in this quoted rate
M &L for refixing only Cold Room & Package Type AC upto 6 TR complete with copper tubing of any type size and make for shifting at other place after making necessary opening in existing wall any type /thickness and fixing of AC with copper tubing and drain out pipline after necessary servicing complete all as specified and directed. Note:Transportation of AC is included in this quoted rate
S&F for flexible pipe 40mm dia heavy duty from oudoor unit to indoor unit including taking down of old unsv complete all as specified and directed
Supply and fix of compressor suitable for 310/320 ltr Refrigerators complete all as directed.
Supply and fix of compressor suitable for 190/215/220 ltr Refrigerators complete all as directed.
Supply and fixt of thermostat suitable for refrigerator of any capacity up to 320 ltr.
Supply and fix of Relay suitable for Sumsung / Godrej/ LG/ Voltas make refrigerator as directedand to match as per existing refrigerator complete all as directed.
Supply and fix of defrost timer for refrigerator of capacity 215 /310/320 Ltr to match as per existing refrigerator.) complete all as directed.
Supply and fix & fix in replacement of bimetal contactor for refrigerator of capacity 215/310/320 Ltr to match as per existing refrigerator complete all as directed.
Supply and fix of magnatic gasket for door suitable for Refrigerator of any type and capacity complete all as directed.
Supply and fix of chiller door of approved brand for refrigerator of any make and type capacity 165/180 ltrs as ordered and suitable for fitted with existing cooling chamber of refrigerator including taking down of existing unsv one as specified and directed
Supply and fix of chiller door of approved brand for refrigerator of any make and type capacity 220/250/310 ltrs as ordered and suitable for fitted with existing cooling chamber of refrigerator including taking down of existing unsv one as specified and directed
Supply and fix of compressor sealed unit including relay suitable for 325/200 Ltrs Deep freezers complete all as directed.
Supply and fix of thermostat suitable for Deep Freeze of any capacity suitable to set with the existing compressor complete all as directed.
Supply and fix of blower motor with blade, single phase, 230v 50 Hz, RPM-1325 suitable for deep freezer
S& F in replacement of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type, ISO certified & designed for input variation between 130 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA Make one of the following :V-Guard/ Brent Ford/ Vinitec/ Automatic Electric.
Supply and fix Over load protector device suitable for existing deep freezer as specified and directed
Supply and fix relay device suitable for 325/200 Ltrs Deep freezer as specified and directed
Supply and fix in replacement including connection 3 pole AC power contactor, AC1 Rating 32 Amps nd AC 3 rating 18A, 415 Volt with auxilary contact 1NO + 1NC, having coil voltage 380 to 400 Volts complete all as directed. Make Simens cat No C4NE22 or equivalent
Supply and fix in replacement of connecting in replacement Intigrated circuit board with all electronic components suitable for 8.5 TR capacity Carrier Pakage type Air conditioner complete all as directed.
Supply and fix in replacement of connecting in replacement high pressure cut off valve 275 lbs suitable for 8.5TR capacity package AC of make Carrier complete all as directed.
S& F in repairs connecting in replacement low pressure cut off valve 25 lbs suitable for 8.5TR capacity package AC of make Carrier complete all as directed.
S& F in repairs connecting in replacement SPPR Circuit board suitable for 8.5TR capacity Package type AC complete all as directed
Supply and fix in replacement of only electronic sensor unit (PCB) suitable for 8.5 TR Package type AC of any make as ordered.
Servicing & maintenance (as and when directed) of Cold room/walk -in-freezer out door/indoor unit outer and inner side cleaning of condensing unit/all filters, dryears complete with vaccume clenear, soap water, castic soda, colin etc of any capacity of any make in situ including, leak testing, brazing the suction / discharge tubes checking electric connection from DBs to machine , sensor unit/cooling effect of airconditioner etc any time during period of the contract for proper functioning complete all as specified and as directed.
Taking out unserviceable Controller circuit board and Supply and fix new electronic Controllercircuit board (PCB Kit) for walk -in - cooler/walk -in- freezer suitable for Carrier / Blue Star make unit, fixinx and connecting to existing system complete all as directed.
Taking out unserviceable defrosting timer and Supply and fix in repairs new defrosting timer with sensor suitable for 3/4Ton AC , cold room 40Amps rating suitable for Carrier / Blue Star make Walk-in-cooler/freezer including connecting complete all as directed.
Taking out burnt power contactor from the panels and Supply and fix in repairs new 3 pole, 415 Volt power contactor with NO & NCs and AC3 current rating 12 Amps complete all as directed. Make L&T, type MNX 12. Cat Ref CS94108/ CS94109 or equivalent
Ditto all as per item No 159 above but AC3 current rating 18 Amps complete all as directed make L&T, type MNX 18. Cat Ref CS94100/CS94101 or equivalent make of ABB/GE power.
Ditto all as per item No 159 above but AC current rating 22 Amps complete all as directed make L&T, type MNX 22. Cat Ref CS94980/CS94981 or equivalent make of ABB/GE power.
Ditto all as per item No 159 above but AC3bcurrent rating 25 Amps complete all as directed make L&T, type MNX 25. Cat Ref CS94110/CS94111 or equivalent make of ABB/GE power.
Taking out burnt power contactor from the panels and Supply and fix, fix & connecting new 3 pole, 415 Volt power contactor of AC3 current rating 25 Amps, 2 NO + 2NC complete all as directed make L&T, type ML 1.5, equivalent make of ABB/GE power.
Taking out burnt Single Phase Prevntor from the panels and Supply and fix, fix in repairs new Single Phase Prevntor Relay (Type SDz5 415V) and testing complete all as directed.
Taking out unserviceable solenoid valve of cold room and Supply and fix, fix in repairs new solenoid valve as per existing type complete all as directed.
Disconnecting and taking out unserviceable fan motor of evaporator with blade and Supply and fix and fix in repairs new eveporator fan motor with blade as per existing sweep and r.p.m, single phase, 230 volts, 1/2HP including necessary adjustment, fixing and connecing complete all as directed.
Disconnecting and taking out unserviceable fan motor with blade of any sweep and make fixed in out door unit of Cold room and Supply and fix and fix in repairs new fan motor as per existing sweep and r.p.m, single phase, 230 volts, 1/5HP including necessary adjustment, fixing and connecing complete all as directed.
S&F in repairs Strip heater not less than 6-8 mtr length for cold Room Door as per existing specication and as direted.
Taking out existing unserviceable door locks of cold room and Supply and fix in repairs new door locks along with all fittings and fixing accessories as per the existing to suit with the ystem complete all as directed.
Taking out burnt connector blocks from machine and Supply and fix connector in repairs block 32 Amps rated with 4 terminals and connecting complete with replacement of cable lugs. (connector blocks made of bakelite/epoxy).complete all as directed.
Taking out existing damagad magnetic gasket for door of walk-in-cooler/walk-in-freezer and Supply and fix and fixing new rubber gasket of suitable size and fixed on doors/frames with fixing media to make cold room leak proof.
Supply and fix SS-304 equal angle of size 25mm x 25mm x 3mm, fixing with door frame of cold room by means of counter shunk screw/rivets as directed to make good the deshaped door frame including taking out damaged angles from the frame.
Supply and fix of temprature indicating unit in automatically defrosting control monitor sensor display suitable for any type and any capacity for different cold room (as per existing make of Cold room)
Taking down burnt compressor from its position and Supply and fix, install, conecting and testing of hermetically sealed compressure of capacity 3.5 HP, suitable for R-22 refrigerant, AC 3 phase, 415 volt, 50 Hz, having capacity of cooling 4 C suitable for cold room
Taking down burnt compressor from its position and Supply and fix, install, conecting and testing of hermetically sealed compressure of capacity 3 HP, suitable for R-404/410 A refrigerant, AC 230/415 volt, 50 Hz, having capacity of cooling (-) 22 C suitable for walk -in-freezer
S&F in replacement SS-304 Strip of size 150mm and thickness not less than 3mm as per exixting specication and as directed.
S&F machine/hand cut kota stone slab flooring 20-25mm thick over cement screed base CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
Material and Labour for taking down of old u/s UPVC Pipe and S&F of UPVC pipe 25mm dia bore with all fittings (Such as bends, elbow, tees, short pieces, connector,cap, plug ,Socket,Reducer Socket,Reducer Nipple,Reducer Tee,Reducer Elbow and union) and fixed to wall, floor with clip, wall hook, saddles etc.. complete all as specified and directed .
Supply and fix and install Hi wall split type AC units indoor/outdoor complete with cordless remote control unit and with in built air ioniser dual invertor type compressor,copper tube condensing unit with CFC free gas for better indoor air quality with minimum 5 star rating of capacity 2TR single phase including additional copper piping, cabling work, insulation between indoor unit to outdoor unit and provision of MS Brackets for resting of outdoor units (where reqd) or making resting platform of outdoor unit by brick works complete all as directed. Make of Split AC unit : Pansonic/Bluestar/ Carrier/ Voltas/Usha-Daikin/Hitachi.
Supply and fix, installation, commissioning and testing of Water cooler fully stainless steel, electric driven single phase having approx storage capacity 120 Ltr and nominal cooling capacity 60 Ltrs/hour with Refrigerant R-134(a).Make : USHA, Model : SS 120/60G or equivalent of Bluestar/ voltas/uSHA.
Servicing & maintenance (as and when directed) of Child water storage unit outer and inner side cleaning of condensing unit/all filters, dryears complete with vaccume clenear, soap water, castic soda, colin etc of capacity 4.5 HP of any make and any type in situ including, leak testing, brazing the suction / discharge tubes checking electric connection from DBs to machine , sensor unit/cooling effect of airconditioner etc any time during period of the contract for proper functioning complete all as specified and as directed.
Taking down burnt compressor from chilled water plant and Supply and fix, install connecting and testing of hermetically sealed compressure of capacity 4.5 HP, suitable for R-22 refrigerant, AC 3 phase, 415 volt, 50 Hz, having capacity of cooling 4 C suitable for chilled water plant installed at cadet mess.
Tank Down burnt motor from chiller plant and Supply and fix And Fix of Fan Motor suitable for chilled water plant installed at cadet Mess
Supply and fix float valve 40mm dia high Pressure with Polythene float and flynut complete screwed for iron pipe or brass ferrule, rod of suitable length PVC ball with all connecting items as in repair complete all as directed.
Supply and fix of replacement of of solenoid valve- Type HM2
Supply and fix relay -Type LR1-D12316
Supply and fix of temperature indicator sub-O SZ 7510P
Supply and fix temperature indicator sub-T-72
Supply and fix relay MNX-12
Supply and fix relay MNX-A18
Servicing & maintenance (as and when directed) of Ice making/Ice Cube machine unit outer and inner side cleaning of condensing unit/all filters, dryears complete with vaccume clenear, soap water, castic soda, colin etc of any make and any type in situ including, leak testing, brazing the suction / discharge tubes checking electric connection from DBs to machine , sensor unit/cooling effect of airconditioner etc any time during period of the contract for proper functioning complete all as specified and as directed.
Supply and fix in replacement of solenoid valve suitable for ice making machine of make as per existing ice machine/super refrigerator Co Ltd
Supply and fix of replacement of fan motor of condensing unit suitable for ice making machine of 1/5 hp of make as per existing ice machine/super refrigerator co Ltd.
Supply and fix in replacement of Compressor sealed unit of capacity 1 TR suitable for ice making machine of cap 10 ltr hr of make as per existing ice machine/super refrigerator co Ltd.
Supply and fix & charging refrigerant gas R-410 to cooling appliances/cooling equipments complete all as directed.
Supply and fix & charging refrigerant gas R-134 (a) to cooling appliances/cooling equipments complete all as directed.
Supply and fix & charging refrigerant gas R-404 (a) to cooling appliances/cooling equipments complete all as directed.
Supply and fix & charging refrigerant gas R-22 to cooling appliances/cooling equipments complete all as directed.
Supply and fix & charging refrigerant gas R-32 to cooling appliances/cooling equipments complete all as directed.
Servicing/ maintenance (as and directed) of Air cooler/Desert cooler of any capacity type disconnected form water/electric connection and carry out to EM Store and after servicing and testing install the other location as per direction of of Engineer-in-charge . Note :Daily maint complaints in wirting given/handed over by this office shall be attend and rectified by the rep detailed by the contractor. The rate deem to be included in quoted rate. No extra claim on all this shall be entertained.
Supply and fix and fix of replacement of submersible pump suitable for 4000 cfm air cooler vertical/horizontal type as required at site.
Supply and fix and fix of fan blade suitable for plastic body air cooler.
Supply and fix and fix fan motor single shaft of air cooler having 105 watt out put, 1450 r.p.m, operating on 230 v AC
M & L for fan motor1/8 hp double shaft type suitable for air cooler, operating on 230 V AC Supply and fix
Supply and fix only capacitor 4 mfd Pastic casing Lug terminal complete all as specified and directed .
M&L for Sub main wiring two single core PVC insulated unsheathed cable 1100 volts grade, FRLSH, 4 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit including PVC insulated unsheathed FRLSH 4 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed.
M & L for mild steel rolled section connected with each other with welding (angle, tee, channel, beam, hollow sections etc) as in main and cross beams, hip verticle hollow sections and jack rafters, purlins where connected to common rafters and running rils where verticle suctions and fixed in welded in wallsin wall surface with plates and other verticle sections are fixed in ground level embedded in concrete fixed and horizontal sections fixed in wall with bolt completly, fixed with angle, cleats or other connecting plates conforming to Gde Fe -410-W (Gde E-250) quality-B complete all as specified and directed.
Pre painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall tixed with self tapping screws as specified and directed
Preventive Maintenance and servicing of servo voltage stabilizer oil cooled Indoor type of capacity 10KVA and 15KVA 415V 50Hz AC Supply and fix by disconnecting carefully its electric cable connection on primary and secondary side ,checking bothside brushing busbar connections, opening top cover of the voltage stabilizer by unscrewing its nuts bolts washers etc.rectify the oil leakage issues if noticed any during sevicing and refixing the top cover of transformer according to previous system.Servicing of the stabilizer must be done through OEM or authorized personnel including maintaining and submitting the inspection and testing records of each stabilizer to Engineer-In-Charge. Note:The rates quoted aganist the item is deemed to be included for cost of labour for lifting/transporting to civil workshop and restore it.
S&F in replacement Sensing Control Card 240Volts 50Hz AC suitable/Compatible to existing servo voltage stabilzer of Oil cooled type of capacity 10KVA and 15KVA complete all as specified and directed.
S&f in replacement of Suitable Power transformer of Voltage stabilizer of oil cooled type of capacity 10 KVA and 15KVA as directed
S &F in replacement of servomotor 1-ph 240V 50HZ AC suitable/compatible to existing servo voltage stabilizer oil cooled type of capacity 10KVA complete all as specified and directed.
Ditto all as per item no above but of capacity 15 KVA
S & F in replacement voltmeter digital type suitable/Compatible to existing stabilizer oil cooled type capacity 10KVA
M&L for rendering Plaster in CM 1:4 with two coat of wheather proof colour as per existing colour on Chiller plant Outside pipeline of size 100/150mm uo tp 5 mtr in lenth of installed at Habibullah AC Plant all as directed.
S& F in repairs swing type insulated door 900(W)x2000(H)x120 (thikness) mm incl frame of required size PUF insulated Panel cladded with both side SS Sheet, complete with strip heater of not less than 6mtr, kick plate and all acessories i.e locks, hinges, recets etc complete all as per directed.
Taking Down and supply and fix new 4TR Cassette indoor unit 4 way air throw compatible as per existing model and suitable for outdoor unit for R 410A with existing copper pipe properly all as specified and directed. Note : Gas Charging is included in this quoted rate
KESARI AND SONS
Tejas Enterprises
SUNIT TRADING CORPORATION
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .