Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.3 LAccepted-Finance E 172 CHAURA MAIDAN 103 TUNNEL SHIMLA HIMACHAL PRADESH 171001 | SHIMLA | HIMACHAL PRADESH | 171001 | ₹8.3 L | L-1 | Accepted-Finance Responsive |
| 2 | L-2₹8.7 LRejected-Finance | ₹8.7 L | L-2 | Rejected-Finance Not-responsive |
| 3 | L-3₹8.9 LRejected-Finance | ₹8.9 L | L-3 | Rejected-Finance Responsive |
| 4 | L-4₹9.0 LRejected-Finance VPO TAKARIA TEHSIL AMB DISTT UNA HP | ₹9.0 L | L-4 | Rejected-Finance Responsive |
Updated dates
Tender Value
₹10.0 L
EMD Value
₹19,900
Closing Date
30 Jan 2026, 11:00 amClosed
Executive Engineer Electrical Division HPPWD Una
Executive Engineer Electrical Division HPPWD Una
.
2026_PWD_126190_1
NIT No. 8318-8342 dated 13/01/2026
Open Tender
Electrical Works
365 days
Una
Please refer Tender documents.
7 documents required · 7 mandatory
₹350
₹19,900
18 Feb 2026
19 Jan 2026
30 Jan 2026
19 Jan 2026
30 Jan 2026
19 Jan 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modularswitch, modular plate, suitable GI box and earthing the pointwith 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Make :- Anchor (Roma classic ) / L&T(Entice) / Legrand(Myrius) as approved by Engineer-In-Charge.
Group B
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface /recess heavy class PVC conduit having wall thickness minimum 2 mm, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Make :-Anchor (Roma classic )/ L&T(Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge.
GROUP-B
wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recess heavy class PVC conduit having wall thickness minimum 2 mm, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.FRLS PVC insulated copper conductor single core cable etc as required.Make :-Anchor (Roma classic )/ L&T(Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
5/6 Amp Switch
5 pin 5/6 Amp Socket
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.Make :-Anchor (Roma classic )/ L&T(Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge.
Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.Make :- Anchor (Roma classic )/ L&T(Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge.
Wiring for circuit/submain wiring alongwithearthwirewith the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. Make:- Finolex/ Plaza/ Anchor as approved by Engineer -in -charge .
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVCconduit as required. Make:- Finolex/ Plaza/ Anchor as approved by Engineer -in -charge .
3 X 1.5 sq. mm
3x4.0 Sq. mm.
3x6.0 Sq. mm.
3x10 Sq.mm.
6x 6 Sq.mm.
Supplying and fixing of following sizes of PVC conduit along with accessories insurface/recess including painting in case of surface conduit, or cutting the walland making good the same in case of recessed conduit as required.Make:-Diplast/AKG/ BEC India as approved by Engineer-In-Charge..
Supplying and fixing of DLP 105x50 mmPVC adaptable trunking on the exiting wall at required height from lower level for power connection, light connection and net working connection including partition chip flexible cover end cap .Make:- Legrand / MK as required complete in all respect .
Supplying and fixing surface round recess type LED 18 watt, 4000k,with clear glass cover with die cast aluminium housing and it should be compatible with specification i.e. Power Factor > .9, Harmonic Distortion<10% and efficacy 100 Lumens per watt,& luminous flux 1800 lm suitable for input voltage: AC 220-240 V, 50/60Hz, life span >50000 hrs @L70,SPD 4KV complete with all accessories, connections, testing and commissioning etc. Make:- Jaquar/Philips/wipro as approved by Engineer-In-Charge.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
supplying and fixing D hook with 2 nos anchor fastner.as required.
Supplying and fixing of fancy wall bracket of chrome finish colour with opal glass diffuser made of mild steel, with single holder containing thread type LED lamp holder(s) of all sizes and shapes, complete with all accessories but excluding led lamp including making connections, testing etc. as required. Make:- Philips/ Jaquar/ Wipro as approved by Engineer-in -charge.( Five year warranty)
Supplying and fixing batten/ angle holder including connection etc. as required.Make :-Anchor (Roma classic )/ L&T(Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge.
Supplying and fixing Ding dong bell suitable for single phase, 230 volts, complete as required.
Providing and fixing of IP65 Bulkhead led fixture 10 W +/- 1 W Wall Mounted with minimum system lumen efficacy of 100 lm/W with Pressure Die Cast Aluminum housing, Polycarbonate Opal Diffuser and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 .The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K only with CRI of minimum 80.The Input voltage range shall be 140V to 280V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. Make:- Jaquar/Philips/wipro as approved by Engineer-In-Charge.
Providing and installation exhaust fan of 300 mm light duty (Domestic type) in the existing opening,including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: Make : Usha /Bajaj/ Crompton as approved by Engineer-In-Charge.
Providing and installation exhaust fan of following sizes in the existing opening,including making the hole to suit the size of the above fan, making good thedamages, connections, testing and commissioning etc. as required: Make:- Usha(S.PH TURBO HDEF 900 RPM )/ Bajaj/ Crompton as approved by Engineer-In-Charge.
Exhaust Fan, (Heavy Duty), 300 mm sweep
Supplying and fixing Aluminium batten LED 36 watt, 6500k, with clear glass cover with die cast aluminium housing and it should be compatible with specification i.e. Power Factor > .9, Harmonic Distortion<10% and efficacy >100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. Make:- Philips/ Jaquar/ Wipro as approved by Engineer-In-Charge. (Five YEAR WARRANTY )
Supplying and fixing Aluminium batten LED 12 watt, 6500k, with clear glass cover with die cast aluminium housing and it should be compatible with specification i.e. Power Factor > .9, Harmonic Distortion<10% and efficacy >100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. Make:- Jaquar /Philips/wipro as approved by Engineer-In-Charge. (Five YEAR WARRANTY )
Providing and Fixing of LED fixture 600mmX600mm 36 Watt +/- 1W Recess/surface mounted fixture with PC diffuser with minimum system lumen efficacy of 100 lm/W & Luminous flux 5040 lm with CRCA housing having P.F.>0.95 with THD<10% ,CRI 80.The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 5700 K with CRI of minimum 80. The Input voltage range shall be 150V to 270V, 50/60 HZ ,spd 4kv complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. Make:- Jaquar /Philips/ Wipro as approved by Engineer-In-Charge. (Five YEAR WARRANTY )
Supply and fixing of following watts LED Stree light 60 watt,IP 65 Alminum Die cast Pressure Housing, PC lens diffuser with Toughened Glass Cover having minimum system lumen efficacy of 100 lm/Watt with beam angle of 70 degree with P.F.>0.95 and THD<10% ,CRI >70. he LED shall be compliant with Useful L70 life of >50000 HrS The surge protection shall be 4 KV Driver (with SPD 10KV/5KA and overvoltage and short circuit protection inbuilt. The input voltage range of 140V to 300V with 5 KV internal surge protection and 10 KV external surge protection. Make:- Philips/ Wipro/ Jaquar/ as approved by Engineer-In-Charge. (five year warranty)
Supply and fixing exhaust fan louver shutter for 300/380mm exhaust fan on the existing wall painting etc. as required.
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation made from (50 mm x 50 mm x 6 mm thick) M.S. angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm thick M.S. angle iron each 60 cm long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-The panel should be approved /Tested from the CPRI lab.& should confirmed to IEC: 64139 I) , 300mm Deep.
Supplying and fixing copper strip bus-bars suitable for 100 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required.
Providing and fixing following rating and breaking capacity MCCB 4pole with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required (five year warranty). Make :-L&T/ Legrand/ Hagger /Schneider as approved by Engineer-in -charge.
40 amp ,18 KA.
63 amp,18 KA.
S/F indicator set R Y & B with 3 Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(five year warranty) Make :-L&T/ Legrand/ Hagger /Schneider as approved by Engineer-in -charge.
MCB 6 TO 32 AMP
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-(five year warranty) Make :-L&T/ Legrand/ Hagger /Schneider as approved by Engineer-in -charge.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.(five year warranty) Make :-L&T/Legrand/Hagger /Schneider as approved by Engineer-in -charge.
40amp, double pole, (single phase and neutral)
63amp, double pole, (single phase and neutral)
Supplying and fixing of MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator(five year warranty) Make :-L&T/ Legrand/ Hagger/ Schneider as approved by Engineer-in -charge.
8 way, Double door
12 way, Double door
16 way Double door
Supplying and fixing true power make advanced earthing system having copper pipe 3 meter long 50 mm dia with terminal size 50x6 mm ,internal strip size 25x3 with 50 Kg compound including exvation of pit and refiling the same and making earthing pit cover 12 inch dia as required complete in all respect. Make :- True power /Earth plus/ Ashloka as per best satisfaction of Engineer-in -charge.
Providing and fixing 6 SWG (4 mm dia.) Copper . wire on surface or in recess for loop earthing as required.
Supplying and fixing LED Lamp 9 watts 6500 K E-27 ,900 Lumens 240 volts AC.supply 50 HZ in the existing batten holder,pendent holder,wall bracket & bulk head fitting etc, as required. Make:- TISVA ( Cat no AL916611X) )/ Wipro/ Philips Make :-Tisva /Panasonic / Philips as approved by Engineer-In-Charge.( Five year warranty)
Supplying and fixing 4 pole MCCB Enclosure with all accessories including connections as required. Make:- L&T /Legrand/ Hager/ ABB as approved by Engineer-in charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.42 MB
SBD.pdf
Tender Documents • 4.25 MB
BOQ_186004.xls
BOQ • 0.31 MB
undertaking.pdf
Additional Documents • 0.38 MB
Download all tender documents and submit your bid