GE GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
REPAIR/MAINT TO DG SET/CAPACITOR PANEL, STREET LIGHT REPAIR, HIGH MAST LIGHT AND OTHER ALLIED WORKS AT BASISTHA AREA UNDER GE GUWAHATI
2022_MES_532452_1
GE/GUW/15/8209 OF 2022-23
Open Tender
Civil Works
Item Rate
270 days
GUWAHATI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE GUWAHATI
₹32,000
26 Aug 2022
21 Jun 2022
29 Jul 2022
21 Jun 2022
27 Jul 2022
5 Jul 2022
21 Jun 2022 - 28 Jun 2022
Amount
Taking down old unserviceable flood light/street light/ Post top lantern fittings etc any type including brackets, cable and connections complete all as specified and directed.
S&F Post top lantern LED type 40 Watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp and connecting up with and including two core PVC insulated cppper conductor cable of 2.5 Sqmm complete all as specified and directed
S&F LED street light fitting 60 Watt 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and connecting up with and including two core PVC insulated cppper conductor cable of 2.5 Sqmm complete all as specified and directed
S&F LED street light fitting 90 Watt 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and connecting up with and including two core PVC insulated cppper conductor cable of 2.5 Sqmm complete all as specified and directed
S&F LED flood light 120 watt 230 volts AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and connecting up with and including two core PVC insulated cppper conductor cable of 2.5 Sqmm complete all as specified and directed.
S&F LED flood light 210 watt 230 volts AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and connecting up with and including two core PVC insulated cppper conductor cable of 2.5 Sqmm complete all as specified and directed.
S&F 40mm bore GI pipe bracket (Light Grade) of length 2 mtrs bent to shape and fixed with 25mm x 4mm MS flat with necessary nuts, bolts, washers etc, as required and painting with two coats of syntheic enamel paint over a coat of primer anf fixed to pole complete all as specified & as directed.
S&F 50mm bore GI pipe bracket (Light Grade) of length 2 mtrs bent to shape and fixed with 25mm x 4mm MS flat with necessary nuts, bolts, washers etc, as required and painting with two coats of syntheic enamel paint over a coat of primer anf fixed to pole complete all as specified & as directed.
S&F in repair 4 Sq.mm size two core PVC insulated cppper conductor cable of for connection from junction box to street light fittings run through pole complete all as specified and as directed.
M&L thermpolastic cable junction box IP55 with metric knocknouts for cable entry and 4 way terminal of size 155mm x 210mm x 92mm fixed in position with aluminum clamps of size 25mmx 3mm and necssary nuts and bolts complete all as specified and directed.
M & L preparation of old painted surfaces of LT steel tubular pole 9.00 m long, cross arms, bracings, supports, clamps, back plate with nut bolts washers and providing one coat of aluminium paint including numbering and making strips in circular shape of diameter 150 mm black colour letter of hight 50 mm complete all as directed by Engr in Charge not exceeding 150 mm upto 1.5 mtr above ground level with alternate layer of yellow and black paint complete all as specified & as directed.
M & L preparation of old painted surfaces of LT steel tubular pole 11.00 m long, cross arms, bracings, supports, clamps, back plate with nut bolts washers and providing one coat of aluminium paint including numbering and making strips in circular shape of diameter 150 mm black colour letter of hight 50 mm complete all as directed by Engr in Charge not exceeding 150 mm upto 1.5 mtr above ground level with alternate layer of yellow and black paint complete all as specified & as directed.
Disconnecting electrically of Automatic power factor correcting panle (APFC panel ), of 125/100 kVAr capacity by taking out the enclosure including all components ,checking of power factor correction capacitors, APFC relay, capacitor duty contactors complete and refixing the same after duly repaied and replacement of unserviceable components/parts and testing of power factor after reparing complete all as specified and directed. Note:- New Spare/Parts shall be measured and paid separately under relevent items as “Supply only”)
Supply only power factor correction capacitors heavy duty cylindrical (Gas filled) 2.5 KVAr , 440 Volts complete all as specified and directed. Make: L&T /Schenider/Havells
Supply only power factor correction capacitors heavy duty cylindrical (Gas filled) 5 KVAr , 440 Volts complete all as specified and directed. Make: L&T / Schenider/Havells
Supply only power factor correction capacitors heavy duty cylindrical (Gas filled) 7.5KVAr , 440 Volts complete all as specified and directed. Make: L&T/ Schenider/Havells
Supply only power factor correction capacitors heavy duty cylindrical (Gas filled) 20 KVAr , 440 Volts complete all as specified and directed. Make: L&T or equivalent Schenider/Havells
Supply only Capacitor duty contactor 30 KVAr , 415V , 3 Ph , 50 Hz Type MO C33.5, built in auxiliary contacts 1 NO complete all as specified and directed. Make: L&T(Cat No CS96323) or equivalent Schenider/Havells
Supply only illuminated push button, red/green complete all as specified and directed.
Supply only LED type RYB indicating lamp(Set of three) complete all as specified and directed.
Supply only 6 Amps control fuse link and base complete all as specified and directed.
Supply only 16 Amps control fuse link and base complete all as specified and directed.
Supply only 32 Amps control fuse link and base complete all as specified and directed.
Supply only MPX 50, 50Amps TP, 415 Volts, power contactor complete all as specified and directed.
Supply only MPX 25, 25Amps TP, 415 Volts, power contactor complete all as specified and directed.
Supply only MPX 12, 12Amps TP, 415 Volts, power contactor complete all as specified and directed.
S&F malifunction meter of series 4110, Make L&T Cat Part No. WL 411020OOOO complete all as specified and directed.
M&L for trimming of tree branches (by taking proper shut down from Sub-Station) near LT/HT over head lines upto 3 m clearance around the line on all sides including removing from site all as required and directed. (Note : T&P and ladders will be arranged by the contractor at his own cost)
S&F Test point terminal block made of gun metal or phosphorusbronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw complete all as specified and directed.
M&L Earthing with Galvanised Steel Earth Plate Electrode 600x600x6 mm thick, buried directly in ground vertically to a depth not less than 2.25 METRE below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 METRE below normal ground level, connected to GI Earth Strip 32 x 6 mm drawn through and including GI Pipe 40 mm bore (dia) ‘light grade’ for protection upto 1.00 METRE above the Floor Level of the Building where Main Switch/DB situated, by means of Bolts, Nuts, Check Nuts and Washers etc., Earth Plate surrounded by a packed thickness of Char Coal or coke dust mixed with common Salt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6 (20 mm graded aggregate) and Pre-cast RCC 1:2:4 (20mm graded aggregate) Cover Slab 350x350 x50mm, reinforced with and including 8.0 mm dia TMT Bars @ 100 mm centre to centre both ways, GI wire mesh, Funnel with GI Watering Pipe 20mm bore (dia) ‘medium grade’, necessary excavation in soft/loose soil, returning, filling in and removal of Surplus Spoil upto a distance of 50 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion, complete all as specified and as directed.
Repair/Servicing of Diesel Engine Make : Kirloskar, Model No. KG 200 WS2 (Ser No F6 9623/1300028) directly coupled with alternator of 200 KVA capacity, draining out the existing engine oil from the bottom of the oil sump and checking the entire serviceablity system of DG set testing and commissioning the same at site complete all as specified and as directed.. Note: (i)New Spares as required shall be measured and paid separately under item nos 32 to 38 as “Supply only” and cost of repairing id deemed to be inclusive in the unit rate quoted) (ii) DG set shall be checked for servicing once in 6 months or 200 hour whichever is less (iii) Work shall be carried out through Original manufacturer or their autorized dealer, cetificate of the same shall be produced commencement of work (iv) Proper record of testing shall be maintained as directed by Engg-In-Charge (v) Quoted rate is inclusive of necssary oiling and greasing, cotton ware, brushes etc and T&P required for the same
Supply only Fuel Filter
Supply only Lub Oil Filter
Supply only Air filter (Inner + Outer)
Supply only Relay Card
Supply only ESU (Engine safety unit)
Supply only Temperature Sensor Device
Supply only Rubber hose pipe suitable for 200 KVA DG Set
Repair/Servicing of Diesel Engine Make : Cummins, Model No. NTA 855 G2 1 (Ser No 25391943) directly coupled with alternator of 320 KVA capacity, draining out the existing engine oil from the bottom of the oil sump and checking the entire serviceablity system of DG set testing and commissioning the same at site complete all as specified and as directed.. Note: (i)New Spares as required shall be measured and paid separately under item nos 32 to 38 as “Supply only” and cost of repairing id deemed to be inclusive in the unit rate quoted) (ii) DG set shall be checked for servicing once in 6 months or 200 hour whichever is less (iii) Work shall be carried out through Original manufacturer or their autorized dealer, cetificate of the same shall be produced commencement of work (iv) Proper record of testing shall be maintained as directed by Engg-In-Charge (v) Quoted rate is inclusive of necssary oiling and greasing, cotton ware, brushes etc and T&P required for the same
Supply only Fuel Filter
Supply only Lub Oil Filter
Supply only Air filter (Inner + Outer)
Supply only Rubber hose pipe suitable for 320 KVA DG Set
Repair/Servicing of Diesel Engine Make : Kirloskar, directly coupled with alternator of 63/62.5 KVA capacity, draining out the existing engine oil from the bottom of the oil sump and checking the entire serviceablity system of DG set testing and commissioning the same at site complete all as specified and as directed.. Note: (i)New Spares as required shall be measured and paid separately under item nos 32 to 38 as “Supply only” and cost of repairing id deemed to be inclusive in the unit rate quoted) (ii) DG set shall be checked for servicing once in 6 months or 200 hour whichever is less (iii) Work shall be carried out through Original manufacturer or their autorized dealer, cetificate of the same shall be produced commencement of work (iv) Proper record of testing shall be maintained as directed by Engg-In-Charge (v) Quoted rate is inclusive of necssary oiling and greasing, cotton ware, brushes etc and T&P required for the same
Supply only Fuel Filter
Supply only Lub Oil Filter
Supply only Air filter (Inner + Outer)
Supply only Feul injector of 63 KVA DG Set
Supply only injector claw of 63 KVA DG Set
Supply only Rubber hose pipe suitable for 63 KVA DG Set
Repair/Servicing of Diesel Engine Make : Kirloskar, directly coupled with alternator of 140 KVA capacity, draining out the existing engine oil from the bottom of the oil sump and checking the entire serviceablity system of DG set testing and commissioning the same at site complete all as specified and as directed.. Note: (i)New Spares as required shall be measured and paid separately under item nos 32 to 38 as “Supply only” and cost of repairing id deemed to be inclusive in the unit rate quoted) (ii) DG set shall be checked for servicing once in 6 months or 200 hour whichever is less (iii) Work shall be carried out through Original manufacturer or their autorized dealer, cetificate of the same shall be produced commencement of work (iv) Proper record of testing shall be maintained as directed by Engg-In-Charge (v) Quoted rate is inclusive of necssary oiling and greasing, cotton ware, brushes etc and T&P required for the same
Supply only Fuel Filter
Supply only Lub Oil Filter
Supply only Air filter (Inner + Outer)
Supply only Rubber hose pipe suitable for 140 KVA DG Set
Disconnecting and taking down carefully defective self starter of 24 volt capacity of 320/200 KVA DG Sets duly disconnecting all electrical cable connections and mechanical supports, transporting the same to civil authorised work shop and dismantling and opening into parts of self starter for assessing the defects and damaged parts and rectifying the defects by changing the defective spares including testing the same after replacement of defective spares and bring back the self starter from workshop to site and re-install the same to its original position and reconnect all disconnected connections and mechanical supports etc. all as specified and as directed..
Disconnecting and taking down carefully defective self starter of 24 volt capacity of 140/125/63 KVA DG Sets duly disconnecting all electrical cable connections and mechanical supports, transporting the same to civil authorised work shop and dismantling and opening into parts of self starter for assessing the defects and damaged parts and rectifying the defects by changing the defective spares including testing the same after replacement of defective spares and bring back the self starter from workshop to site and re-install the same to its original position and reconnect all disconnected connections and mechanical supports etc. all as specified and as directed..
Disconnecting and dismantling including taking down carefully radiator assembly from 140 KVA DG Set for cleaning soldering including servicing dully disconnecting all water hose and other mechanical supports, transporting the radiator assembly to work shop, opening into parts cleaning the radiator fans with cleaning such as cotton waste cotton rags and soda water etc. soldering/brazing the broken/leakage fins and reassembling the same after replacement of defective spares and transporting the same from workshop to site and mounting its to original position including testing etc. complete all as directed.
Supply only Engine Oil suirable for DG Set (K-Oil 15W/40) in 20 Ltrs Container complete all as specified and as directed.
Supply only Engine Oil suirable for DG Set (K-Oil 20W/40) in 20 Ltrs Container complete all as specified and as directed.
Supply only Coolent suirable for DG Set in 5 Ltrs Container complete all as specified and as directed.
S&F in repair, Battery, 12 Volts, AH-180, plate -25, suitable for DG Set including initial charging.complete all as specified and as directed. Make: Exide, Model No-IN1800 plus or equivalent as approved by GE from list of makes
S&F in repair, Battery, 12 Volts, AH-105, suitable for DG Set 63 KVA to 125 KVA including initial charging.complete all as specified and as directed. Make: Exide, Model No-GP 115E41L or equivalent as approved by GE from list of makes
Supply only distilled water in 1Ltr packed bottle suitable battery all as per sample of approved make, complete all as specified and directed.
Supply only brass battery terminals (Set of two) complete all as specified and as directed.
Disconnecting and dismantling including taking down carefully injector pump for 140/125/63 KVA DG Set for calibration and setting, and reassemble same after calibration and setting and mounting its to original position including complete testing etc. complete all as specified and as directed. Note:- Cost of transporation & any minor parts required is deemed to included in the Unit Rate
Disconnecting and dismantling including taking down carefully injector pump for 320/200 KVA DG Set for calibration and setting, and reassemble same after calibration and setting and mounting its to original position including complete testing etc. complete all as specified and as directed. Note:- Cost of transporation & any minor parts required is deemed to included in the Unit Rate
Discnnecting electrically and opening AMP Panel of 140/125/63 KVA capacity DG Sets and checking all electrical cable connection and power contactors, rectifying the defects complete and refixing the same after duly repair and replacement of unserviceable components/parts and testing of panel after reparing complete all as specified and directed. Note:- New Spare/Parts shall be measured and paid separately under relevent items as “Supply only”)
Discnnecting electrically and opening AMP Panel of 320/200 KVA capacity DG Sets and checking all electrical cable connection and power contactors, rectifying the defects complete and refixing the same after duly repair and replacement of unserviceable components/parts and testing of panel after reparing complete all as specified and directed. Note:- New Spare/Parts shall be measured and paid separately under relevent items as “Supply only”)
Supply only Power contactor 160 Amps 4 Pole with dust cover complete all as specified and as directed. Make: C&S Cat Part No. LC1FDP1154A
Supply only Power contactor 200 Amps 4 Pole with dust cover complete all as specified and as directed. Make: C&S Cat Part No. LC1FDP1154A
S&F in repair, MS angle/channel conforming to Fe 290 Gde E-165 fabricated to shape and size to support structure of feul tank/shed/fencing including necessary preperation of surfaces and applying one shop coat of red oxide, zinc chrome primer complete all as specified and as directed.
M.G. ENTERPRISE
M/S SEWAK SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .