| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.1 L+₹56,982 (2.53%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹25.5 L+₹2.9 L (13.1%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹26.1 L+₹3.6 L (15.9%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹28.2 L+₹5.7 L (25.1%)Rejected-Finance 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-Finance L5 |
Tender Value
₹39.0 L
EMD Value
₹77,960
Closing Date
12 Jan 2023, 6:00 pmClosed
GE JAIPUR
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
REPAIR/MAINT OF INTERNAL ELECTRIFICATION WORK IN HAMID VIHAR, JADUNATH VIHAR, AND ZONE - I AREA UNDER AGE E/M OF GE JAIPUR
2022_MES_569279_1
GE/J-59/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
JAIPUR
As per NIT
5 documents required · 5 mandatory
₹500
GE JAIPUR
₹77,960
Yes
2 Mar 2023
15 Dec 2022
14 Jan 2023
15 Dec 2022
12 Jan 2023
30 Dec 2022
15 Dec 2022 - 29 Dec 2022
Amount
Taking down carefully aluminum or copper point wiring including exisitng PVC casing caping /concealed conduit for (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified and directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including concealed rigid non metallic PVC condiut medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings/ fixing accessories and unwelded sunken galvanised pressed steel terminal boxes boxes of thickness not less than 1.0 mm and covered with 3mm thick phenolic laminated white sheet cover plate for switches, sockets as required for one light point controlled by one switch.
All as per item No. 02 here-in-before but one fan point controlled by one switch.
All as per item No. 02 above but one light point controlled by two, two way switch.
All as per item No. 02 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 02 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 02 here-in-before but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn into and including concealed conduit rigid non metallic PVC condiut medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings/ fixing accessories and unwelded sunken galvanised pressed steel terminal boxes boxes of thickness not less than 1.0 mm and covered with 3mm thick phenolic laminated white sheet cover plate for switches, sockets as required for one socket point 16 Amps controlled by one switch on independent board.
M&L for point wiring with 1100 volts grade PVC insulatd FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including PVC casing-capping not less than 32x16 mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3mm thick phenolic laminated white sheet cover/ PVC gang box for mounting sheet cover for mounting switches, sockets, fan regulators one light point controlled by one switch.
All as per item No. 09 here-in-before but one fan point controlled by one switch.
All as per item No. 09 here-in-before but one light point controlled by two, two way switch.
All as per item No. 09 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 09 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 09 here-in-before but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulatd FRLS multistranded copper conductor cable 4.0 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 4.0 Sqmm (Green) drawn into and including PVC casing-capping not less than 32x16mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0mm covered with 3mm thick phenolic laminated white sheet cover / PVC Gang box for mounting sheet cover for mounting switches, sockets for one 16 Amps socket outlet point controlled by one switch on independent board.
S&F angle holder, insulated polycarbonate body with back plate complete.
S&F switch piano flush button single pole one way 6 Amp complete.
S&F switch piano flush button single pole one way 16 Amp complete.
S&F flush type, 6 Amp, single pole, two way complete.
S&F bell push, flush type, 6 Amps 240 volts complete.
S&F socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type compete.
S&F socket outlet, 2-in-1, 3 pin 6 Amps flush type compete.
S&F hum free electronic stepped type fan regulator 120-280 volts of 100 watts capacity including connecting up complete.
S&F in repair switch piano flush button single pole one way 6 Amp complete.
S&F in repair switch piano flush button single pole one way 16 Amp complete.
S&F in repair socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type compete.
S&F in repair socket outlet, 2-in-1, 3 pin 6 Amps flush type compete.
S&F in repair hum free electronic stepped type fan regulator 120-280 volts of 100 watts capacity including connecting up complete.
S&F door bell AC 240 volts, single pole complete.
S&F ceiling rose 3 plates polycarbonate body complete.
Taking down carefully sub main wiring with PVC casing capping/PVC surface conduit and making good disturbed surfaces complete.
M&L for submain wiring with two runs of single core PVC insulated and unsheathed, multistranded FRLS copper conductor of size 6.00 sqmm, LT cable, 1100 volts grade and one run of 6 sqmm single core, multistrand copper conductor (green) as earth continuity conductor drawn into 20 mm dia concealed conduit complete all as specified and directed. NOTE: Two runs of 6 sqmm cable, one run of 6 sqmm cable along with conduit including acessories shall be measured as one running metre of submain wiring.
All as per item No. 32 above but 2x10 Sqmm + 1x10 Sqmm earth in 25mm dia conduit.
S&F in repair MCBs of 'C' series single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F MCBs of 'C' series single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F MCBs of 'C' series SPN 10 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F in repair MCCB four pole, 125 Amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs as required.
S&F in repair MCCB, 415 volts, 04 pole, 63 Amps, 35 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed
S&F in repair MCCB, 415 volts, 04 pole, 125 Amps, 35 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed.
S&F in repair LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 125 lumen per watt and total power consumption not more than 20 watt including driver. It has a rated system life time of 50000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete.
S&F LED bulk head fitting 10 watt IP 66 & IK 09 with pressure die cast aluminium housing & polycarbonate diffuser duly pre wired connection with 0.75 Sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable complete.
Taking down MCB distribution boards with incoming and outgoing controls any make any capacity after disconnecting complete.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 4 ways.
All as per item No 43 above but SPN, 240 volts, 8 ways.
All as per item No 43 above but SPN, 240 volts, 12 ways.
M&L for Labour for taking out old unservicable UG, LT cable of any size from trenches, wall, pipe etc complete all as directed.
S&F 1100 volt grade heavy duty XLPE insulated armoured cable with aluminum conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 25 Sqmm nominal cross section 4 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed.
All as per Item No. 47 above but of size 10 Sqmm nominal cross section 2 core.
All as per Item No. 47 above but of size 16 Sqmm nominal cross section 4 core.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in soft/ loose soil complete all as specified and directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil complete all as specified and directed.
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
M&L for sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying including gently punning around cable complete all as specified in SSR Part-I and directed.
M&L for bricks well burnt sub class 'B' laid in trenches flat with width equal to length of brick for cable protection laid across the cable complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick wall build on cement mortar 1:4 and 2 coats of white/colour washing to match the surface including 10mm thcik plaster in CM 1:4 complete.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6.0mm buried directly in ground, vertically to depth not less than 2.25mtr below normal ground level with top edge of the earth plate at depth not less than 1.5 metre below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI strip of size 32x6mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe medium grade 20mm bore for watering, 40mm bore GI pipe medium grade for protection of GI strip upto test point including providing funnel and wire mesh GI frame and 10cm thick suitably reinforced RCC pit cover, PCC chamber pit with PCC (1:3:6) type C2 using 40mm graded stone aggregates complete including excavation and earth work in any type of strata, disposal of surplus soil to a distance not exceeding 50 mtr, all as specified ans shown in Electrical plate No. 3 of SSR Part-1, PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit including testing on completion complete. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
S& F in repair integral LED flood light 100 W 3000 K with a nominal system lumes output of 7200 lumens and a minimum system efficacy of 90 lumes/ watt. The luminaire shall have rated system lifetime of 50,000 burning hours before reaching at L70. The liminarire should have cool white colour temperature (CCT > 3000K) and a CRI > 70. The luminair shall meet IP 66 rating & IK05 rating with THD <20% and PF >90. The luminaire housing should be made of pressure die cast aluminium with a flat glass optical cover. the total power consumption should not exceed 100W including driver complete all as directed.
Taking down carefully storage type water heater (geyser) any make and capacity from clamp/bolts including disconnecting water and electric connection including checking defects and replacement of u/s parts and re fixing the same and connecting up after cleaning of geyser and repair complete. (Note - U/s parts shall be meausred separately as supply only under relavent items of this BOQ)
Supply only geyser apparatus plate (any make, any type) copper alloy chromium plated suitable for geysers 25/50 litre capacity including rubber gasket, nuts / bolts etc complete.
Supply only heating element 2.0 KW, 230 volts, ISI marked suitable for 25/ 50 litre capacity geysers of any type as required.
Supply only thermostat ISI marked suitable for 25/50 litres geysers as required.
Supply only stainless steel inner tank suitable for 25 litre capacity geysers housing complete.
Supply only dis cut out switch suitable for 25 litre capacity geysers ( make of geyser MARC) complete.
Supply only capillary thermostat set suitable for 25 litre capacity geysers ( make of geyser MARC) complete.
Renewal of brass chromium plated, flexible pipe connection 15 mm bore 450 mm long heavy duty suitable for hot water supply with two numbers brass chromium plated nuts at end complete.
Renewal of PVC insulated over all PVC sheathed three core copper cable of size 2.5 sqmm complete.
S&F in repair hot water pipe duly insulated with glass wool and aluminium cladding 15mm bore.
Supply and fixing in replacement of LED indicator lamp Red , Yellow and Blue including wire and lugs etc complete
S&F in repair of LED fixture 10 watt having lumen output 100 lumens per watt including connection.
Dismantling and taking down unserviceable / defective street light fitting / Flood light fitting of any wattage alongwith mounting bracket, flat iron clamp, nuts bolts etc from Bldgs complete all as directed.
Supply and fixing in repair LED street light fitting 35/36 Watt minumum 100 lumens/watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, clamp bracket 1.2mtr long with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply, installation, testing and commissioning, in replacement, Junction box, cubical type, factory made, outdoor type of Size 45cm(l) x30cm(w) x60cm(h), dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, complete with openable shutters in front and rear having proper locking arrangement including including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC and aluminium bus bar of size 400 Amps capacity, Three phase and neutral bus bar, making hot and cold drilling holes to aluminium bus bar. Junction box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 160 Amps,240/415 Volt, 50Hz, 10 KA= 01 Nos (I/C) b) MCB SPN 63 Amps, 240 Volts - 04 Nos (O/G) Note : Unit rate quoted by the contractor here-in-before also includes for fixing and connecting of MCBs and installation of panel on PCC foundation complete all as per manufacturer instructions and as directed by the Engr-in-Charge.
Bluemax Associate
M/S TRADE LINKERS
M/s Radhey Enterprises
M/S SHARADA ASOCIATE
M/S Anil Enterprises
SHREE BHAGWATI ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .