| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-Finance | L1 | Accepted-Finance Qualified for 60 percent work | |
| 2 | L2₹5.1 L+₹5,369 (1.06%)Accepted-Finance | L2 | Accepted-Finance Qualified for 40 percent work | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Qualified in TC Bid Evalauation |
Tender Value
₹4.9 L
EMD Value
₹9,808
Closing Date
26 Aug 2024, 3:00 pmClosed
Executive Engineer (E), BSNL, Bhubaneswar
Door Sanchar Bhawan, Unit-IX, Bhubaneswar-751022
R and M of Pump sets
2024_BSNL_205118_1
NIT No- 14/BSNL-EDB/2024-25
Open Tender
Electrical Works
Item Rate
365 days
BSNL Bhubaneswar BA
3 documents required · 3 mandatory
₹590
A O (Cash), BSNL, O/o GMTD, Bhubaneswar.
₹9,808
Yes
21 Sept 2024
16 Aug 2024
27 Aug 2024
16 Aug 2024
26 Aug 2024
16 Aug 2024
16 Aug 2024 - 23 Aug 2024
Amount
Making conveyance arrangements for Pump Mechanics along with spare parts, tools and instruments etc. for attending the Pump set faults at different Telephone Exchange / staff quarters on need basis etc. as required.
Distance up to 50 Kms from Bhubaneswar
Distance above 50 Kms and up to 100 Kms from Bhubaneswar
Distance above 100 Kms and up to 150 Kms from Bhubaneswar
Attending minor faults in the pump sets/control panels/starters and restoration of the pump sets i/c replacement of starters, relays, switches, contactors and assessing the materials required/works to be carried out in case of major faults etc. as required
Withdrawing a 3HP/4HP/5HP submersible pump set from the Bore well along with delivery pipe lines after disconnection of power supply cable, delivery pipes etc. complete as required.
Withdrawing of 3HP/4HP/5HP open well submersible pump set from the UG sump after disconnection of power supply cable, delivery pipes etc. complete as required.
Transportation of the faulty pump set from site to nearest authorized service centre and bring back to site after repairing i/c loading and unloading etc. as required.
Dismantling the submersible Pump motor set, checking and fault finding, preparation of bill of materials/defect list etc. complete as required.
Servicing of the 3HP/4HP/5 HP, 3 phase 415 volts 50 Hz bore well submersible pump set i/c cleaning of mud depositions, servicing and re-assembling after rewinding and repairing/replacement of existing defective/worn out parts/components etc. as required.
Rewinding of the 3 HP/ 2.2 KW, 3 phase 415 volts, 8.4 Amps, 50 Hz vertical type submersible pump motor (Make :KSB CORA 100/12C+UMA100) with bright annealed high conducting electrolytic copper PVC insulated copper wire of suitable size and quantity etc. complete as required. (The dismantled materials may be retained by the Contractor)
Rewinding of the 4 HP/ 3 KW, 3 phase 415 volts, 8.4 Amps, 50 Hz vertical type submersible pump motor (Make :KSB CORA 100/12C+UMA100) with bright annealed high conducting electrolytic copper PVC insulated copper wire of suitable size and quantity etc. complete as required. (The dismantled materials may be retained by the Contractor)
Rewinding of the 5 HP/ 3.75 KW, 3 phase 415 volts, 50 Hz vertical type submersible pump motor with bright annealed high conducting electrolytic copper PVC insulated copper wire of suitable size and quantity etc. complete as required. (The dismantled materials may be retained by the Contractor)
Rewinding of the 5 HP, 3 phase 415 volts, 50 Hz horizontal type Open well submersible pump motor (Model: MR 5.0 HH, 3.7 Kw, 9.3A, Make- Kirloskar Brothers Ltd) with bright annealed high conducting electrolytic copper PVC insulated copper wire of suitable size and quantity etc. complete as required. (The dismantled materials may be retained by the Contractor)
Replacement of the following defective parts /components of 3/4/5 HP submersible pump set by new ones of approved make etc. as required.
Gun metal Bush i/c lathe works
Thrust Plate
Impeller
Stainless Steel Strainer with 3" Short piece pipe i/c lathe works
Oil seal
Tie Rods with nuts and washers etc.
Re-installation of the repaired 3HP/4HP/5HP submersible pump set along with delivery pipe lines etc. in the bore well i/c reconnection of delivery pipe, electrical power supply cable, testing and trial run etc. complete as required.
Re-installation of the repaired 3HP/4HP/5HP submersible pump set in UG sump i/c reconnection of delivery pipe, electrical power supply cable, testing and trial run etc. complete as required.
Replacement of the following damaged pipe lines with accessories by new ones of following sizes i/c all plumbing works etc. as required. (Sch-80)
40mm dia CPVC pipe
40mm dia CPVC Elbow
40mm CPVC Union
40mm dia CPVC Socket (Plastic Threaded)
40mm CPVC "T"
40mm MAPT
40mm FAPT
40mm MABT
40mm FABT
Replacement of the following damaged pipe lines with accessories by new ones of following sizes i/c all plumbing works etc. as required. (Sch-80)
50mm dia CPVC pipe
50mm dia CPVC Elbow
50mm CPVC Union
50mm dia CPVC Socket (Plastic Threaded)
50mm CPVC "T"
50mm MAPT
50mm FAPT
50mm MABT
50mm FABT
Replacement of the defective and damaged water line valves by new ones of the following types and sizes i/c fixing and testing etc. as required.
40mm CPVC Ball Valve
50mm CPVC Ball Valve
40mm CPVC Foot Valve
50mm CPVCFoot Valve
40mm dia Brass Ball Valve
50mm dia Brass Ball Valve
50mm CI Foot Valve
Replacement of the defective and damaged water line valves by new ones of the following types and sizes i/c fixing and testing etc. as required.
40mm dia Brass Non Returned Valve
50mm dia Brass Non Returned Valve
10mm thick MS bore well cover plate and MS flat clamps for holding the bore well pipe & pump
Replacement of the burnt out/faulty/damaged/worn out Submersible cable and nylon ropes by new pne of following types and sizes i/c fixing, connection and testing etc. as required.
3 core 1.5sqmm weather proof copper conductor submersible flat cable
3 core 2.5sqmm weather proof copper conductor submersible flat cable
8mm Nylon Rope
Replacement of faulty/burntout main switch for the pump sets by new one of 63Amps 415 volts 50 Hz Tripple pole and Neutral link main switch in SS enclosure with porcelain rewirable fuses and neutral link i/c connection, testing etc. as required. (Standard/havells/L & T/SS
Replacement of following sizes ISI marked HDPE pipes (PE80, SDR-11, PN-10 ) for the submersible pump sets by new one of approved make etc. as required.
40mm dia
50mm dia
Replacement of Stainless Steen Reducer Nipple for HDPE pipes etc. as required.
KISLAY KUMAR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .