REPAIR/ REPLACEMENT OF LT CONNECTION NETWORK INCLUDING LT PANEL IN TRG AREA AT DIV HQ IN URGENT BASIS UNDER GE SGNR
2025_MES_700110_1
3000/SGNR/47/E3
Limited
Job Works
Works
60 days
GE SRIGANGANAGAR
Please refer tender documents.
2 documents required · 2 mandatory
₹0
Exempted
13 Mar 2025
6 Mar 2025
12 Mar 2025
6 Mar 2025
11 Mar 2025
6 Mar 2025
Amount
REPAIR/REPLACEMENT OF LT CONNECTION NETWORK INCLUDING LT PANEL IN TRG AREA AT DIV HQ UNDER GE SGNR (a) Taking down old U/S /rusted junction box and LT Pannel complete all as specified and directed- Each job- 07 Nos. (b) Taking down old U/S LT cable any size all as specified and directed- RM-376 (c) Supply, install, test and commisioning of duly powder coated Sheet metal enclosure Bus bar chamber copper bus bar of 4 way capacity 100 Amp with MCCB 63 Amps Adjustable thermal and adjustable magnetic release, 415 volts having rupturing capacity 16 KA -01 No as out going and incoming connecting cables of new/existing cables with suitable sizes aluminum thimbles including suitable angle stand with foundation work as per directed by Engr -in Charge- Each job- 06 Nos. (d) Supply, install, test and commisioning of LT panel duly powder coated of suitable size outdoor cubical type factory made, weather & vermin proof made out of CRCA sheet 3.15mm (outdoor type) thick machine pressed with bottom frame made out of angle iron 50mm x 50mm x 6mm and 600mm long 4 legs grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over 100 mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete and suitable for 415 Volt AC 3 phase, 4 strip having insulated Mains Copper bus bar 400 Amps for three phases and neutral , Panel with openable double shutter on both sides (rear and front side) with locking arrangment duly pre-wired with suitable size of copper conductor cable fitted with Incoming proper size copper lugs/thimbless and connecting the incoming and outgoing MCCBs with suitable size strip duly bended and drilled and fixed with nuts, bolts & washers from bus bar to MCCBs etc duly fitted with and including the following accesories & all connected iems complete. Incoming i MCCB 315 Amps four pole with Adjustable thermal and adjustable magnetic release 415 V AC supply having rupturing capacity 36 KA - 01 No Outgoing ii MCCB 160 Amps Four pole with Adjustable thermal and adjustable magnetic release 415 volts having rupturing capacity 25 KA - 1 Nos iii MCCB 63 Amps Adjustable thermal and adjustable magnetic release 415 volts having rupturing capacity 16 KA - 6 No. iv MCB TPN - 01 Nos 25 Amp -01 Nos v Indicating lamps set RYB - 01 Set vi Digital Amp Meter 0- 315 A with CT Digital Voltmeter 0- 500 V (e) Supply, laying & testing of XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade cross-sectional area 25 Sqmm 4 Sqmm - 376 RM (f) Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all as specified and directed by Engineer-in-Charge- Cum - 95.04 (g) Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge- Cum- 56.71 (h) Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge- Cum - 38.33 (j) M & L for sand cushioning with dry coarse canal sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment- Cum - 28.51 (k) Supply and lay PCC block Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specifed and directed- Each - 2347 Note- Make of all items mentioned above will be as per command approved list of HQ SWC
THAKURJI ENTERPRISES (BID ID -3259861)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .