Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC 00 PANCHARIYA NEAR SANTOSHI MATA TEMPLE MAHARASHI GOUTAM MARG NEW LINE GANGASHAHAR BIKANER BIKANER BIKANER RAJASTHAN 334401 | BIKANER | RAJASTHAN | 334401 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹24.2 L+₹5.7 L (31.1%)Rejected-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | Rejected-Technical HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | - | Rejected-Technical Not enlisted in appropriate category c (i) as per NIT. | |
| 4 | Rejected-Technical 316 VIJAY NAGAR EXTENSION RANJHI MAIN ROAD JABALPUR MP | JABALPUR | MADHYA PRADESH | 482001 | - | Rejected-Technical Not enlisted in appropriate category c (i) as per NIT. |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
23 Sept 2021, 6:00 pmClosed
HQ CWE Jabalpur
HQ Commander Works Engineer, Supply Marg, P B No. 54, Jabalpur
REPAIR /MAINTENANCE OF CENTRAL AC PLANT UNDER GE ( EAST ) JABALPUR.
2021_MES_470418_1
82572/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jabalpur
As per NIT
7 documents required · 7 mandatory
₹500
GE (East) Jabalpur
₹40,000
Yes
28 Feb 2022
25 Aug 2021
25 Sept 2021
25 Aug 2021
23 Sept 2021
9 Sept 2021
26 Aug 2021 - 8 Sept 2021
Amount
M&L for Taking out /disconnecting and refixing after descaling of sluice valves and condensers for descaling and plugging it & providing 15mm' T' outlet for local circulation of mild acid solution in the condenser ( seprate container and small pump set to circulate diluted acid solution to be used ) correct ph value of solution to be circulated and it should be checked every hour during the operation . scalegon water solution (as approved by GE) to be used for descaling purpose after 2 to 3 hours of cleaning , if PH-value remains less than 7, flush water will be added in the sodium carbonate ,tubes to be cleaned with nylon brush and closing the end covers after circulated diluted acid solution as specified as above and ph value to be maintained and flushing the same with fresh water including cleaning of cooling tower and all of the sluice valves with lines in the system with diluted acid, recharging of stored refrigerant up to required pressure complete as specified and directed by Engineer – in- Charge,for the followings :
Complete AC Plant 2 X 10 TR Capacity
Complete AC Plant 3 X 12 TR Capacity
Complete AC Plant 2 x 17.5 TR capacity
Complete AC Plant 2 x 35 TR capacity
Taking down and refix after rewinding of monoblock pump motor of following capacity , 3 phase , 50Hz with super enameled copper winding wire ,make : Atlas / Devidyal / Finolex, including replacement of unserviceable accessories i.e bushes , impellers , locking key and nuts , washers etc to mono block pump including transportation of pump and motor for repair complete all as specified and directed by Engr-in-Charge:-
Mono block pump with motor complete set capacity 5.0 HP
Mono block pump with motor complete set capacity 7.5 HP
Mono block pump with motor complete set capacity 10 HP
Taking down and refix after rewinding of AHU/CT Fan motor of following capacity, 3 phase , 50 Hz with super enameled copper winding wire , make :Atlas / Devidyal/ Finolex, including replacement of unserviceable accessories i.e. bearing,nuts , washers etc including transportation of motor for repair complete all as specified and directed by Engr-in-Charge:-
Motor capacity 5.0HP
Motor capacity 10HP
Supply and fix, in replacement, AHU / BLOWER’S pedestal bearing complete all as specified and directed by Engr-in-Charge.
Replacement of unserviceable thermostatic expansion valves suitable for upto 80 TR Central AC Plant , make :-Sanlan/Danfoss/Avcon/Sporlan pilot solenoid control valve or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
M & L for replacement of unserviceable brass liquid line valve 25 mm PS25, make :-DANFOSS or equivalent to list of make as approved by GE complete all as specified and directed by Engr-in-charge.
S&F in replacement of unserviceable digital electronic type temperature meter with RH arrangement range of approx '0' degree centigrade to '50' degree centigrade complete all as specified and directed by Engr-in-charge.
M &L for replacement of old unserviceable water thermometer in range of approx '0' degree centigrade to '50' degree centigrade complete all as specified and directed by Engr-in-charge.
S&F in replacement of old unserviceable safety control valve ( pressure relief type ) size approx. "3/8“ , ½” at condenser unit, make : Accel / Indofoss / Danfoss or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
M& L for replacement of old unserviceable water pressure gauge of capacity approx 14 kg/cm2 complete all as specified and directed by Engr-in-charge.
Repair to LT electric control panel board, cleaning inside with blower, servicing, tightening all electrical connections/ contact points,replacing defective locking clips thimble and making it serviceable with interlocking wiring including replacement of defective parts and refixing back in its existing position complete all as specified and directed. Note:-spares / accessories of mains electric control panel are measured and paid for separately under relavant items of this schedule.
S&F, in replacement, unserviceable MCB 32 Amps ,3 Phase,415 Volt,50Hz, Make : L&T/C&S or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
S&F, in replacement, unserviceable contactors type ML2/ML1.5/ML.1.0, Make :L&T /C&S or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
S&F, in replacement unserviceable contactors type ML3, Make :L&T /C&S or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
S&F, in replacement, unserviceable ML 2/ML 3 relay range 28-42 A /20-32 A, Make L&T or equivalent to list of make as approved by GE complete all as specified and directed by Engr-in-charge.
S&F, in replacement unserviceable ML 1.5 /ML1.0 relays range 14-16/4-6.5 A, Make L&T or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
S&F, in replacement unserviceable electronic timers / GT-100 /MPR -500/SPP 240/360/415V, 50Hz range 3-10,9-30 , 30 -120 sec, make :L& T /GIC/ C&S or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
S&F, in replacement,unserviceable Volt meter / Ampere meter as suitable existing approx CT ratio-100/5 & 30/5 of make :- Essma / AE or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
S&F, in replacement, unserviceable toggle switch 16Amp : Make : L&T / C & S or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
S&F, in replacement, unserviceable indicator lamp (green , red , yellow ) 220V, 50Hz, MAKE : L&T /Bishnu/Bentex/ SCI or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
S&F, in replacement, unserviceable ON/OFF push button Make:- L& T / C&S / SCI or equivalent to list of make, as approved by GE, complete all as specified and directed by Engr-in-charge.
S&F, in replacement, unserviceable shaft seal assembly with completed accessories for SMC-4-65, Make :ACCEL or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
S&F, in replacement, unserviceable shaft seal assembly with complete accessories for SMC-4-100, Make :ACCEL or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
S&F, in replacement, unserviceable shaft seal assembly with complete accessories suitable for 20TR-30TR capacity of compressor of Make :- CARRIER / VOLTAS or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
S&F, in replacement, unserviceable shaft seal assembly with complete accessories for SMC-3-65 of Make :ACCEL or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
M & L, in replacement, unserviceable HP/LP cut out, make : Indofos / Danfoss/Accel or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
M&L, in replacement, unserviceable op cut out, make : Indofos/Danfoss/Accel or equivalent to list of make as approved by GE complete all as specified and directed by Engr-in-charge.
M&L, in replacement, old unserviceable solenoid valve (capacity control valve) suitable for upto 80 TR Central/Package AC Plant, Make :-Sanlan/Danfoss/Avcon/Accel/Sporlan or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
M&L, in replacement, unserviceable high pressure gauge/low pressure gauge/Oil pressure gauge for refrigeration system used refrigerant as R-22/F-22(pressure range approx 0-300 lb/sq inch ) all as specified, Make : Fiebig/Adarsh/Accel or equivalent to list of make as approved by GE, complete all as specified and directed by Engr-in-charge.
M&L, in replacement, old unserviceable chocked PVC fills/ Honey comb of cooling tower with new PVC fills/Honey combs in suitable existing size for upto 80 TR capacity cooling tower of AC plant complete all as specified and directed by Engr-in-charge.
S&F, in replacement, unserviceable float valve with brass stop cock in cooling towers water make up tanks suitable for existing size 1/2 “, 1/4 “, 1” including necessary suitable water supply fittings ie. Socket, nipple, reducer etc. complete all as specified and directed by Engr-in-charge.
S&F, in replacement, of FRP Eliminator sutaible for upto 80 TR AC Plant cooling tower of different size complete all as specified and directed by Engr-in-charge.
Replacement of A.H.U room strip heater suitable for air condition plant capacity 3 KW complete all as specified and directed by Engr-in-charge.
Taking down 5 HP to 40 HP motor with isolating rotor & stator,cleaning & greasing in the exiting bearing & reassembling of complete motor & fixing on same position complete all as specified and directed by Engr-in-charge.
M & L for cleaning,scrubing & painting of complete central/package type AC PLANT (Capacity 2 X 10 TR) with one coat synthetic enamel paint in existing/approved colour code including pumps ,motors, startors, LT panel board,fan blower,compressor,pipe line, condenser etc complete all as specified and directed by Engr-in-charge.
Supply and filling, in replacement, compressor oil complete all as specified and directed by Engr-in-charge.
S&F, in replacment, V Belt for AC plant size B-76/A 50/C 102/B 38/B 87 etc. complete all as specified and directed by Engineer-in-Charge.
S&F, in R-22 Refrigerant gas also vaccum and pressure leakage testing with nitrogen (N2) (if required) is deemed to be included under the unit rate quoted by the contractor for this item complete all as specified and directed by Engineer-in-Charge.
Supply & fix, in repairs, ball bearing (set of two Nos) suitable for capacity of 3 HP electric motor/ mono block motor complete all as specified and as directed.
Description all as per item No. 40.00 above but of capacity 5.0 HP.
Description all as per item No. 40.00 above but of capacity 7.5 HP.
Description all as per item No. 40.00 above but of capacity 10.0 HP.
Description all as per item No. 40.00 above but of capacity 12.5 HP.
Description all as per item No. 40.00 above but of capacity 15.0 HP.
Supply only MCB TP,'C' series 63 Amps, 240 Volts, 50 HZ, 10 KA for panel board to be fixed under respective items here in- above, of make :- L & T / Havells / HPL / Indo Asian/ Legrand as aproved by GE.
Supply only MCB TP,'C' series 40 Amps, 240 Volts, 50 HZ, 10 KA for panel board to be fixed under respective items here in- above, of make :- L & T / Havells / HPL / Indo Asian/ Legrand as aproved by GE.
Supply only connector 4 pole, 240 volts for panel board to be fixed under respactive items here in- above complete all as specified and directed.
Supply only CR bearing of existing make suitable for compressor of capacity SMC 3 X 65 series to be fixed under respective items here- in- above, complete all as specified and as directed.
Supply only main bearing of existing make suitable for compressor of capacity SMC 3 X 65 series to be fixed under respective items here- in- above complete all as specified and as directed.
S & F in repairs, strips heater 3 KW single phase complete all as specified & directed. Make : DAS PASS or equivalent to list of make as approved by GE .
Dismantling & taking out the uncerviceable crank shaft of compresseor of capacity SMC 3 X 65 series and supply & fixing new crank shaft of existing make and refixing the compressor in its original position and checking of leakage by Nitrogen gas and stoping the leakage by fixing required parts/ procedure with complete material & labour as required complete all as specified and directed.
Dismanting & taking out the uncerviceable crank shaft of compresseor of capacity SMC 4 X 65 serics and supply & fixing new crank shaft of existing make and refixing the compressor in its original position and checking of leakage by Nitrogen gas and stoping the leakage by fixing required parts/ procedure with complete material & labour as required complete all as specified and directed.
supply & fix, in repairs, automatic phase sequence corrector of rating 31.0 to 50.0 HP, RPC- 30 type complete all as specified and directed Make:-SECO or equivalent to list of make as approved by GE.
Supply & fix, in repairs, Neoprene 'O' ring of AC plant of capacity SMC 3x65 series of existing make complete all as specified and directed.
Supply & fix, in repairs, cooling tower fan motor of capacity 5.0 HP, 3 Phase, 1440 RPM with extended shaft including taking down old uncerviceable blower motor and deposited to MES store yard complete all as specified and directed. Make:- Kirloskar , Crompton Greaves, ABB or equivalent to list of make as approved by GE.
Supply & fix, in repairs, cooling tower fan monoblock pumping set completed with motor of capacity 3.0 HP, 3 Phase, 1440 RPM with extended shaft having minimum 22.0 Metre head including taking down old uncerviceable pumping set and depositing to MES store yard complete all as specified and directed. Make:- Kirloskar , crompton Greaves , ABB or equivalent to list of make as approved by GE.
Supply & fix, in repairs,thermostatic expansion valve flange type of size suitable for 3 X 70.0 TR (R-22) AC plant including making all necessary connections complete all as specified and directed.
Supply & fixing, in repairs, PVC water protection cover/jali for protection from birds, leaf etc to cooling tower tank complete all as specified and directed.
Supply and fixing, in replacement, PCB complete sutaible for package type 11 TR AC Plant complete all as specified & as directed by Engineer-in-Charge. (Make:Softhard, Voltas, Blue Star or equivalent to list of make as approved by GE)
Supply and fixing, in replacement, PCB complete sutaible for package type 17 TR AC Plant complete all as specified & as directed by Engineer-in-Charge. (Make: Softhard, Voltas, Blue Star or equivalent to list of make as approved by GE)
Supply and fixing, in replacement, PCB complete sutaible for package type 22 TR AC Plant complete all as specified & as directed by Engineer-in-Charge. (Make: Softhard, Voltas, Blue Star or equivalent to list of make as approved by GE)
Supply and fixing, in replacement, liquidline filter drier MWP 500-900 Psig Make-Sigma/Uniwel/Dryall/Danfoss or equivalent as approved by GE complete all as specified and directed by Engineer-in-Charge.
Supply and fixing, in replacement, compressor complete sutaible for package type 11 TR AC Plant complete all as specified & as directed by Engineer-in-Charge. (Make:Softhard, Voltas, Blue Star or equivalent to list of make as approved by GE)
Supply and fixing, in replacement, compressor complete sutaible for package type 17 TR AC Plant complete all as specified & as directed by Engineer-in-Charge. (Make: Softhard, Voltas, Blue Star or equivalent to list of make as approved by GE)
Supply and fixing, in replacement, compressor complete sutaible for package type 22 TR AC Plant complete all as specified & as directed by Engineer-in-Charge. (Make: Softhard, Voltas, Blue Star or equivalent to list of make as approved by GE)
Supply , install , commissioning and testing, in replacement, Cooling coil suitable for SMC-3-65 type ACCEL compressor AHU unit of 20 TR complete all as specified and as directed by Engr-in-charge.
S&F, in replacement, unserviceable butterfly valve conforming to IS 13095, 80 mm (3”) dia complete all as specified and as directed by Engr-in-charge.
S&F, in replacement, non return valve 80mm dia CI both ends flanged conforming to IS Make-Kirloskar or equivalent as approved by the GE, complete all as specified and as directed by Engr-in-charge.
S&F, in replacement, 80 mm C.I. Y Type Strainer conforming to IS Flanges End, Make- Divine/Kirloskar or equivalent make as approved by GE, complete all as specified and directed by Engr-in-charge.
S&F, in replacement, 80 mm GI pipe heavy grade conforming to IS Flanged End, Make- Kesoram/Jindal/Tata or equivalent make as approved by GE complete all as specified and as directed by Engr-in-charge.
Supply, installation, commissioning and testing in replacement of 20 TR induced draft top discharge counterflow type FRP Cooling Tower (Rectangular/Round bottle shape) with FRP body and base, water spray headers, cooling tower fills, fan with motor, supporting base frames, as per manufacturer's standard instructions complete all as specified and as directed by Engr-in-charge.
M&L for cross arm bracing supports clamps and back plate fabricated from structural steel section including nuts bolts in any type shape and size as indicated or directed and inclusive of two coat of Aluminium paints over a coat of red oxide complete all as specified and as directed by Engr-in-charge.
S&F, in replacement, copper pipe of size "7/8” complete all as specified and as directed by Engr-in-charge.
S&F, in replacement, copper Elbow of size "7/8” complete all as specified and as directed by Engr-in-charge.
S&F, in replacement, copper Socket of size "7/8” complete all as specified and as directed by Engr-in-charge.
S&F, in replacement, Hand set Valveof size" 5/8” , Make:- Denfos or equivalent as approved by GE complete all as specified and as directed by Engr-in-charge.
M&L for duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the followings :- (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of mill scale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide,to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr of size 25 mm."
Supply , assembly and erection of GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt,Gasket and appropriate sealant on longitudinal joints etc of size 26 Gauge complete all as specified and directed.
Material and Labour for complete leak testing the AC plant of 20 TR to 80TR cap, chiller / direct expansion type and rectify the leaks in the joints valves, gauge board, compressor gas & oil connections and pressure testing the system with Nitrogen gas, and holding the pressure for 48 Hrs. check for any drop, vaccumising the system as per the standard and charging only the gas, testing & commissioning the plant complete all as specified and directed.
Schedule of credit amount of Rs. 1,00,005.00 to be deducted during AOC
Uma engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .