Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L1 | Accepted-AOC Lowest quoted | |
| 2 | L2₹26.5 L+₹70,938 (2.75%)Rejected-Finance 02 RUDIA BIT MESRA ROAD NEORI VIKAS RANCHI JHARKHAND 835217 | RANCHI | JHARKHAND | 835217 | L2 | Rejected-Finance Other than lowest quoted | |
| 3 | L3₹30.5 L+₹4.7 L (18.4%)Rejected-Finance SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | L3 | Rejected-Finance Other than lowest quoted | |
| 4 | L4₹31.5 L+₹5.7 L (22.2%)Rejected-Finance VILL POST MANJHULI PS BAKHITIYARPUR KHUSRUPUR DIST PATNA BIHAR 803202 | NALANDA | BIHAR | 803202 | L4 | Rejected-Finance Other than lowest quoted | |
| 5 | L5₹34.7 L+₹8.9 L (34.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest quoted |
| Sl No | Description | Qty | Unit | M/S Sahib N Sahiba Enterprises L6 | BHARATI ENTERPRISES L3 | Raj Construction L1 | M/s Pramod Kumar Singh L5 | M/s Sri Narayan Info Ventures Private Limited L7 | K K GUPTA L8 | THE SUVASH AND SONS L2 | M/S JAI MATA DEE CONTRUCTION CO. L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully exising unserviceable aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed. | 1,119 | Per Point | 50 ₹55,950 | 15 ₹16,785 | 20 ₹22,380 | 115 ₹1,28,685 | 123.5 ₹1,38,196.5 | 25 ₹27,975 | 2 ₹2,238 Lowest | 73 ₹81,687 |
| 2.00 | Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed. | 300 | RM | 40 ₹12,000 | 5 ₹1,500 | 5 ₹1,500 | 15 ₹4,500 | 13.8 ₹4,140 | 9 ₹2,700 | 2 ₹600 Lowest | 5 ₹1,500 |
| 3.00 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified. | 35 | Each | 150 ₹5,250 | 50 ₹1,750 | 5 ₹175 | 60 ₹2,100 | 61.7 ₹2,159.5 | 40 ₹1,400 | 2 ₹70 Lowest | 12 ₹420 |
| 4.00M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :- (Note- Modular cover plate of any module with all fittings are included in point wiring.) Contractor should make good even distributed wall/surface as before. | |||||||||||
| 4.10 | One light point controlled by one, one way switch 5 Amps | 120 | Per Point | 670 ₹80,400 | 645 ₹77,400 | 600 ₹72,000 | 800 ₹96,000 | 805 ₹96,600 | 700 ₹84,000 | 500 ₹60,000 Lowest | 580 ₹69,600 |
| 4.20 | One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator | 25 | Per Point | 870 ₹21,750 | 645 ₹16,125 | 600 ₹15,000 | 800 ₹20,000 | 805 ₹20,125 | 700 ₹17,500 | 500 ₹12,500 Lowest | 580 ₹14,500 |
| 4.30 | One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. | 30 | Per Point | 610 ₹18,300 | 750 ₹22,500 | 600 ₹18,000 | 850 ₹25,500 | 870 ₹26,100 | 700 ₹21,000 | 550 ₹16,500 Lowest | 580 ₹17,400 |
| 4.40 | One bell point controlled by one, bell switch 5 Amps | 1 | Per Point | 810 ₹810 | 600 ₹600 | 600 ₹600 | 800 ₹800 | 805 ₹805 | 750 ₹750 | 500 ₹500 Lowest | 500 ₹500 Lowest |
| 4.50 | One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. | 15 | Per Point | 290 ₹4,350 | 120 ₹1,800 | 70 ₹1,050 Lowest | 225 ₹3,375 | 230 ₹3,450 | 150 ₹2,250 | 90 ₹1,350 | 210 ₹3,150 |
| 5.00 | Description all as per item No 4 here in before but using 2.5 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common earth dolly. | 5 | Per Point | 740 ₹3,700 | 800 ₹4,000 | 680 ₹3,400 | 900 ₹4,500 | 919 ₹4,595 | 1,025 ₹5,125 | 700 ₹3,500 | 610 ₹3,050 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 Aug 2025, 6:00 pmClosed
Shri Dhiraj Kumar, Offg GE
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
REPAIR/ REPLACEMENT OF ELECTRIC FITTINGS AND FIXTURES INCLUDING REWIRING TO CERTAIN OTM ACCN AND REPAIR/ MAINT TO STREET LIGHT AND CONNECTED ITEM OF WORK FOR 1 (I) RO FLT AND ALL AREAS UNDER LPH AREA UNDER GE RANCHI
2025_MES_719350_1
8400/1268/E8
Open Tender
Civil Works
Item Rate
180 days
GE Ranchi
Class D Cat b (i)
6 documents required · 6 mandatory
₹500
Garrison Engineer Ranchi
₹90,000
Yes
22 Sept 2025
9 Jul 2025
13 Aug 2025
9 Jul 2025
6 Aug 2025
23 Jul 2025
Amount
Taking down carefully exising unserviceable aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed.
Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :- (Note- Modular cover plate of any module with all fittings are included in point wiring.) Contractor should make good even distributed wall/surface as before.
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One bell point controlled by one, bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
Description all as per item No 4 here in before but using 2.5 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common earth dolly.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with GI sunken /surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches, or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- (Note- Modular cover plate of any module with all fittings are included in point wiring.)
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One bell point controlled by one, bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
Description all as per item No 6 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified.
S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
S & F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified.
S & F ceiling fan regulator switch type, step type, flush type heavy duty, 120 watts suitable to work on 230 volts Ac supply including removal of old unserviceable one complete all as specified.
S & F for Bell push modular 6 Amps single module complete all as specified.
Suply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
S & F for Lamp holder, PVC body suitable for batten fitting completes all as specified.
S & F for Ceiling rose, surface Bakelite suitable ISI marked for batten fitting complete all as specified
S & F for Switch piano flush type, single pole, one way, and 6 Amp complete all as specified.
S & F for Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, piano flush type complete all as specified.
S&F in replacement of switch socket combinations flush 5 Amp 5 pin competeI ,ISI marked
S&F switch socket combination 2 in 1, 3 pin, 15 amp multipurpose, flush type, all as specified and as directed
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size concealed in wall etc including one run of PVC insulated 2.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 2.5 sqmm cable and one run of PVC casing caping will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit
S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F MCCB TPN 415 volts 25 KA suitable for fixing on DB of capacity 63 Amps with extended terminals complete all as specified.
S & F MCCB TPN 415 volts 25 KA suitable for fixing on DB of capacity 100 Amps with extended terminals complete all as specified.
Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. Make :-Bajaj, Philips, Havells.
S & F for Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and including provision of LED bulb 10/12 watts complete all as specified and as directed. Make- Havells, Philips, Bajaj.
S & F for LED 10 watts batten aluminium extruded (mirror light) with decorative end caps complete all as specified and as directed. Make- Bajaj, Havells, Philips.
S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed. Make :- Bajaj , Philips, Havells.
S & F for Highly efficient LED Bulbs, 9/10 W complete all as specified and directed
S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and as directed complete all as specified and as directed
S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 40-63 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed.
Supply and replacing 1100 volts grade heavy duty PVC insulated aluminium conductor, served with inner sheathing of PVC in service connections suspended by insulating hangers not more than 1 mtr apart including 4 mm dia GI suspension wire, one twin core cable of size 10 Sqmm multi -strand complete all as specified and directed.
Description all as per Ser item No 41 above but size 6 sqmm twin core cable.
Description all as per Ser item No 41 above but size 4 sqmm twin core cable.
S&F Fan condenser, 2.5 Mfd, 240 volts for fan including PVC clamp at different locations as per site given by Engineer-in-Charge
S & F for recess mounted 2' x 2' square LED panel 36 watts, 596 x 596 x 9 mm size, sleek design aluminium housing, polycarbibate diffuser white powder coated finish operating voltage 140 volts - 270 volts, AC, 50 Hz complete all as specified and as directed.
S & F for LED post top lantern (gate light) 20 watt light fitting made of cast aluminium spigot housing with decarative opal acrylic diffuser with IP 65 protection complete with all accessories fixed on GI pipe 50 mm dia including removal of old unserviceable one complete all as specified and directed.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 4 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
S&F in replacement of flexible wire twin core copper conductor of size 23/0.0076 for fans and tube lights/ pendant fittings connection all as specified and directed
S & F for casing and capping size 20 mm including removal of old unserviceable one complete all as specified and as directed
S & F for metal body exhaust fan, AC single phase, 240 V of size 225 mm sweep 1380 rpm with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and M&L for making hole and proper finishing the surface as existing before and taking down of old unserviceable fan complete all as specified and as directed
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
Excavation in trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable getting out in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed.
Removing Surplus soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
M & L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 18 cm thickness, complete all as specified and as directed. Note : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid.
S & F Sub-Class ‘B’ Brick, well burnt, laid breadth wise along the length of Cable laid in trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description laying in trenches or fixing with Walls/Poles, segreating serviceable Pipes, Cables etc and keep in safe custody for reuse, complete all as specified and as directed. Note : Earthwork will be measured and paid under appropriate Items.
S & F Galvanised Iron Pipe light grade as in protection of UG Cable laid in trenches including necessary MS clamp, nuts, bolts and painting of following sizes complete all as specified and as directed.
50 mm dia
40 mm dia
M & L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of Red Oxide Zinc Chrome Primer, bottom of pole to be painted with synthetic enamel paint of alternate White & Black Strips and remaining portion of Pole and Cross Arms, Cable Protection Pipe, Brackets, etc painted with Two Coats of Aluminium Paint complete all as specified and as directed.
M & L Writing Lettering on Steel Tubular / Pre-stressed Concrete Pole (8 cm in height) with Synthetic Enamel Paint (White) on base of Black Paint in round shape of 15 Cm dia, complete all as specified and as directed.
Trimming of Tree Branch, girth not exc. 150 mm around OH Electric Lines and cleaning , removing trimmed Branches from Site(s) and stacking as ordered, complete all as specified and as directed.
S & F Junction Box for Street Lights of size 250 x 300 x 150 mm made out of CRCA sheet 2 mm thick totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 42 protection single leaf shutter in front having proper locking arrangements, and painted with powder coating paint and suitable size of "connectwell" stud teriminal (provision for socket bolting)- 05 Nos suitable for 415 volts, 50 Hz, 3 phase 4 wire internal wiring system including MCB SP 06 amps- 01 No and mounted on security light pole with suitable clamp made out of MS flat of size 32 mm x 6 mm thick bend to required shape and suitable size of nuts, bolts including removal of existing unsv one of any type complete all as specified and directed.
M & L for Street Light Fitting Bracket made out from GI Pipe 40 mm bore (dia), medium grade 1.50 metre long, bent to required shape and fixing to Poles with and including Clamp sets suitable for tubular pole made out of MS flat iron of size 40 mm x 6 mm thick, Nuts, Bolts as required duly painted with Two Coats of Aluminum Paint over a coat of Red Oxide Zinc Chrome Primer including taking down old unserviceable bracket, comlete all as specified and as directed. Note : Cost of Mild Steel Clamp, Nuts, Bolts and painting is deemd to be included in the quoted Unit Rate.
S & F for Energy saving new generation environmental friendly LED street light luminaire with long life versatile pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection with high power LEDs as light source and electronic driver of capacity 45 watts with pre wired and necessary mounting arrangement and provision of 4 sq mm twin core copper conductor cable multi stranded from fitting to junction box including necessary GI pipe medium braket of required dia 1.5 mtr long bend to required shape with suitable with MS clamps made out of flat iron of size 40 x 6 mm - 02 sets, bolt & nuts and taking down old unserviceable Street Light Fitting form Electric Pole of any description complete all as directed by Engineer- in-charge.
S & F for Energy saving new generation environmental friendly LED street light luminaire with long life versatile pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection with high power LEDs as light source and electronic driver of capacity 60 watts with pre wired and necessary mounting arrangement and provision of 4 sq mm twin core copper conductor cable multi stranded from fitting to junction box including necessary GI pipe medium braket of required dia 1.5 mtr long bend to required shape with suitable with MS clamps made out of flat iron of size 40 x 6 mm - 02 sets, bolt & nuts and taking down old unserviceable Street Light Fitting form Electric Pole of any description complete all as directed by Engineer- in-charge.
S & F for Energy saving new generation environmental friendly LED street light luminaire with long life versatile pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection with high power LEDs as light source and electronic driver of capacity 90 watts with pre wired and necessary mounting arrangement and provision of 4 sq mm twin core copper conductor cable multi stranded from fitting to junction box including necessary GI pipe medium braket of required dia 1.5 mtr long bend to required shape with suitable with MS clamps made out of flat iron of size 40 x 6 mm - 02 sets, bolt & nuts and taking down old unserviceable Street Light Fitting form Electric Pole of any description complete all as directed by Engineer- in-charge.
Supply & Fixing or Passing through pipe, XLPE insulated, Armoured, Electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade, nominal cross sectional area 6 sqmm 2 core including Brass compression cable gland, terminal lug etc and testing complete all as specefied and as directed
Supply & Fixing or Passing through pipe, XLPE insulated, Armoured, Electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade, nominal cross sectional area 10 sqmm 2 core including Brass compression cable gland, terminal lug etc and testing complete all as specefied and as directed
Supply & Fixing or Passing through pipe, XLPE insulated, Armoured, Electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade, nominal cross sectional area 25 sqmm 4 core including Brass compression cable gland, terminal lug etc and testing complete all as specefied and as directed
S&F IP 65 rated high powered LED highbay light 200 W 4000 K with a tough IK10 impact rating at R&O Flight Hangar ceiling. Product ID :12486: Crompton Keto LED High Bay 200W 4000K 60° or its equavalent to Havells/ Philips/ Bajaj .
S&F LED Post top / Gate light 1x20 W decorative type, 360° indirect light including fixing with suitable size GI pipe as required on the top of gate pillar, control by suitable MCBs as per direction and wiring complete all as specified and directed. Make : CG/ Havells/ Philips/ Bajaj
S&F Garden Light/ Bollards 10 W IP 65 are made of extruded Aluminium, profiles with cast aluminium base,opal PC diffusers with integrated LED and driver fixed in proper cemented base complete all as specified and directed. Make:- Crompton Cat Ref No LBLSN-10-CDL or its equivalent in Phillips/Havells/ Bajaj
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified & directed. Make: Havells/ Philips/ Bajaj/ CG
Taking down old unserviceable and Supply and fixing connecting and testing (in replacement) time switch panel box size 400mm x 350mm x170 mm dust and vermin proof made of 16 gauge MS sheet factory made duly painted with two coats of synthetic enamel paint recommended colour over a coat of red oxide primer and mounted inside the following .Location-wise photos be attached alongwith the bills..Note:- Time switch pannel box shall be fixed on one pole/wall in feeder pillar box with flat iron clamp 40x6 mm or other suitable fixing arrangement complete all as specified and directed. (a) MCB triple pole 32 Amps 230 volt-01 No. (b) Analog electro mechanical time switch 24 hours with minimum setting 30 minutes for daily working contact rating 16 Amps,240 volts,AC with initial charging battery backup having supply and reserve failure upto 150 Amp hours and coil voltage 415 volts. (c) AC contactor ,3 pole,ML-2,415 Volts,50 Hz. (d) Internal wiring with pvc insulated stranded copper conductor of suitable size and making electric connection -01 No. (e) By pass MCB single pole ,32/40 Amps,230 volts-01 No. Note:- Time switch panel box shall be fixed on one pole/wall in feeder pillar box with flat iron clamp 40x6 mm or other suitable fixing arrangement complete all as specified and directed.
THE SUVASH AND SONS (BID ID -3375310)
BHARATI ENTERPRISES (BID ID -3376779)
M/S JAI MATA DEE CONTRUCTION CO. (BID ID -3381767)
M/s Pramod Kumar Singh (BID ID -3377475)
M/S Sahib N Sahiba Enterprises (BID ID -3376005)
M/s Sri Narayan Info Ventures Private Limited (BID ID -3377577)
K K GUPTA (BID ID -3377073)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .