Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L1 | Accepted-AOC AOC | |
| 2 | L2₹24.9 L+₹33,600 (1.37%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹25.3 L+₹72,120 (2.94%)Rejected-Finance 364 4 FIRDAUS SHABANA MARKET NEW SABZI MANDI JK COLONY ROAD KANPUR 07 | KANPUR NAGAR | UTTAR PRADESH | 208001 | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹26.6 L+₹2.1 L (8.43%)Rejected-Finance 4 KHEME KA KUA PAL ROAD JODHPUR RAJASTHAN 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Not being lowest tender |
Tender Value
Refer Docs
EMD Value
₹47,140
Closing Date
24 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TA GWALIOR
GE AF TA GWALIOR
PROVN OF E/M RELATED CERTAIN LBW WORKS IN TECH AREA AT AF STN GWALIOR
2020_MES_370680_1
8900/1260/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF TA GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TA GWALIOR
₹47,140
Yes
7 Nov 2020
20 Aug 2020
29 Sept 2020
20 Aug 2020
24 Sept 2020
10 Sept 2020
60 days
Amount
Supplying and Fixing MS angle iron bracket of size 40mmx40mm x4 mm and MS strip of suitable size in frame woRk approx weight of frame 15 KG including drilling holes, cutting, welding etc.and grouting rigidly with necessary masonary work on wall and making good the surface for installation of L2 Unit complete all as specified and directed.
Supplying and Fixing sheet metal enclosure with industrial Power socket and plug top with 20 Amps 230 volts,20 Amp MCB DP with a two pin and earth plug top and socket and surge protection device(SPD) single phase class I protection level 1.5 KV ,response time less than 25 ms,Lighting test current -03KA,Protection rating IP-20 all as specified & directed Make: Havells / Schneider / Legrand / L&T .
Material and labour for earthing complete with copper plate electrode 600mm x 900mm x 5mm thick buried directly in ground vertically to a depth not less than 4.7 meter below normal ground level (with top edge of earth plate not less than 3.6 meter below ground level & complete size of earth pit 1.60m x 1.60m x 5.00m) connected to copper strip 32mm x 6mm as main earthing lead by means of tinned copper / brass bolts, nuts, check nuts and washers besides brazing at all joints all as directed and connected to earth test point all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to test point, made of phosphorous brongze/gun metal of size 75mmx75xmmx25mm dril and screwed including 03 Nos 8mm dia 25mm long hexagonal head screwed, 50mm bore GI medium grade for protection of earth lead from top of plate to test terminal complete, adequate quantity of charcoal dust, magnesium sulphate & common salt in alternate layers of 100mm thick all around the plate, under and above the plate and returning, filling of earth spread, levelled, watered and compected to required level, PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast 40mm thick RCC cover of (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate), reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle, GI medium watering pipe 25mm bore with funnel and wire mesh complete all as specified and directed . NOTE : (i) The cost of earth lead and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’. (ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
Supply and fixing earth continuity conductor or main earthing lead 20mm x3.15mm, copper strip/earth lead, laid in pipe/fixed on walls or any other position including jointing by tinned copper/brass nuts, bolts and washers in addition to brazing at every joint complete all as specified and directed.
M&L for epoxy insulator 1100 volt grade including fixing on wall/RCC piller/blocks with fasteners and fixing the strips on insulators with suitable screw/nuts/bolts etc complete all as specified and directed.
Supply & fixing light grade, 40mm dia GI tubing with all fittings fixed on walls/ poles/ in trenches as in earth lead protection pipe complete all as specified and directed . Make : TATA / Jindal / TT Swastik.
Supply installing commissioning and testing air cooled split unit wall mounted air conditioner with cordless remote control electric driven of capacity 1.5 TR (4500 K cal/Hr) BEE 5 Star rated single pahse suitable for 230V +10% 50Hz Ac supply complete all as specified and directed Make: Daikin / carrier / Blue star (a) Room evaporative indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control air filter and drain for condensing water. (b) Out door condensing unit of capacity 4500 k Cal/ Hrs comprising of 1 no compressor of 1.5 TR capacity with condensor fan motor of appropriate capacity 1 no air cooled condensor of 1.5 TR capacity shall be installed out side the building. (c) Refrigerant copper pipe upto length of 6m each for both suction and discharge line with insulation condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable shall be fixed. (d) Making good the disturbed surface to match the existing surface after plugging the holes etc. Note : (i) Cutting holes in walls / window of any thickness for installation of AC etc surface to match with existing surface after which work shall be done and rate is included in this item . (ii) Electrical cable required to connect outdoor unit with indoor unit to voltage stablizer inclusive in above rate. (iii) Cost of copper piping/ drain piping shall be included in quoted rate.
Supply and fixing wall mounted digital display voltage stabiliser of capacity 4KVA for automatic volatge correction single phase naturally air cooled indoor type designed for input voltage 140volt to 280 volt and out put volatge 230 volt and high/low voltage cutoff with facility of including instant start & time delay relay of 3 minutes complete all as specified and directed. Make: Blue bird/Blue tech
Supplying, fixing & connecting copper earth strip 20 mm x 3 .15mm as in roof conductors / down conductor fixed on walls / roofs with saddels/epoxy insulator at an interval not exceeding 0.5 mtr including screws required at site complete all as specified and directed.
Material & labour for GI water tubing, light grade, 50mm bore, 2 mtr long duly threaded on one side for fixing reducer socket as in Air termination stand / post at roof top of hangers/bldgs complete all as specified and directed. Make : Jindal / Tata / TT Swastik Note : (i) GI reducer socket & PCC/ brick masonry block for fixing of GI pipe post shall be measured and paid for separately under appropriate item of Sch 'A’. (ii) GI pipe 2 mtr will be in a single length & no joint will be allowed.
Material & labour for GI water tubing, light grade, 50mm bore, 3 mtr long duly threaded on one side for fixing reducer socket as in Air termination stand / post at roof top of hangers/bldgs complete all as specified and directed. Make : Jindal / Tata / TT Swastik Note : (i) GI reducer socket & PCC/ brick masonry block for fixing of GI pipe post shall be measured and paid for separately under appropriate item of Sch 'A’. (ii) GI pipe 3 mtr will be in a single length & no joint will be allowed.
M & L for providing test point terminal block made out of Gun metal or phosphorous bronze of size 75 mmx75 mm x25 mm drilled and screwed including 03 nos 8 mm dia 25 mm long hexagonal head screws complete all as specified and directed
Supply & fixing GI reducer Socket (50mm x 40mm bore ), on vertical post / stand complete all as specified & directed.
Supply & fixing aluminium gutka 40mm dia having internal thread of 12mm dia and external thread of 40mm dia and fixed on GI reducer socket complete all as specified and directed.
Supply and fixing Copper Air termination rod single pointed at top and properly threaded at bottom end, 12mm dia and 1200 mm long complete all as specified and directed.
M & L for PCC 1:2:4 for block, type B-I using 20mm graded stone aggregate for block size 150 mm x 100mm X 150mm, set in Cement Mortar 1:4, with and including necessary form work and all exposed surfaces finished even and smooth without using extra cement including removal of old broken unserviceable PCC block at site complete all as specified & directed. Note : A second class hard wood gutty of size 25mm x 25mm x 38mm made to shape shall be embedded in the above PCC block for fixing the screw of saddle / insulator of down conductors / earth strips.
Material and labour for earthing complete with copper earth plate electrode 600mm X 600mm X 3.15 mm buried directly in ground vertically to a depth not less than 3.10 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to coppr strip 20mm x 3 mm as main earthing lead by means of copper/brass bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I, earth lead connected to earth test point & to main switch board / connecting point where required etc with & including adequate quantity of charcoal dust and common salt all around and completly covered the earth plate, PCC 1:3:6 type C-1 using 20mm graded stone aggregate for earth pit with pre cast RCC 1:2:4 type B-1 using 20mm graded stone aggregate, 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe of size 20 mm dia with funnel and wire mesh,etc complete all as specified and directed. Note:- The cost of earth lead upto and including 7.5 metre only from the top of earth plate are deemed to be included under this item and additional earth lead, if any required shall be measured and paid for seprately under appropriate item of Sch A.
M&L for marker fabricated with 14 gauge MS sheet of size 350mm x 250 mm rectangular with 20 mm square hollow bar 60 cm long duly painted of colour as directed and writing ER value, date of testing and due date for testing, Earth pit No etc complete all as specified and directed.
M & L for PCC 1:2:4 for blocks, type B-I using 20mm graded stone aggregate for block size (450 mm x 450mm X 450mm) - 25 Nos and of size (500 mm X 500 mm X 500 mm) - 04 no. all as directed, set in Cement Mortar 1:4, with and including necessary frame work for insertion and including fixing of GI pipe of size 50 mm bore and all exposed surfaces finished even and smooth without using extra cement complete all as specified & directed. Note : casting of blocks to be done on the roof of building for firm jointing with roof surface
IMPEX TRADERS
kay pee construction
M/S M.D. CONSTRUCTION .CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .