Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 CrAccepted-AOC | ₹7.9 Cr | L1 | Accepted-AOC lowest |
| 2 | L2₹8.3 Cr+₹37.9 L (4.79%)Rejected-Finance | ₹8.3 Cr+₹37.9 L (4.79%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹8.6 Cr+₹66.7 L (8.44%)Rejected-Finance | ₹8.6 Cr+₹66.7 L (8.44%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹9.4 Cr+₹1.5 Cr (19.1%)Rejected-Finance | ₹9.4 Cr+₹1.5 Cr (19.1%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹9.9 Cr+₹2.0 Cr (25.1%)Rejected-Finance | ₹9.9 Cr+₹2.0 Cr (25.1%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹7.5 Cr
EMD Value
₹7.0 L
Closing Date
8 Nov 2021, 6:00 pmClosed
CE Bathinda Zone
HQ CE Bathinda Zone Bathinda Mil Stn
Provn of KLP at Lalgarh Jattan
2021_MES_465719_1
CA NO CE BTZ LGJ TOKEN 15 of 2021-22
Open Tender
Civil Works
Lump-sum
762 days
Lalgarh Jattan
as per NIT
10 documents required · 10 mandatory
₹3,000
GE Lalgarh Jattan
₹7.0 L
Yes
26 Nov 2021
19 Aug 2021
10 Nov 2021
19 Aug 2021
8 Nov 2021
27 Oct 2021
Amount
Lump sum price worked out by the tenderer for "Building / Structure Work" as listed in Schedule ‘A’ Section - I.
Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION WORKS” as listed in Schedule ‘A’ Section - II (Part-I)
Sch 'A' Sec - II (Part-II) (INTERNAL ELECTRIFICATION WORK)
Material and labour for concealed Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and made out of 1.6mm thick MS sheet) concealed in wall, 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches/socket, wiring for one light point/fan point /bell point controlled by one switch, including provn of 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ).
All as per Srl No.4.00 here-in-before but for combination switch and socket outlet 5 Amps on the independant board. (combination switch/socket shall be measured and paid separately under appropriate item of BOQ).
All as per Srl No.4.00 here-in-before but for socket outlet 5 Amps on the same board. (switch/socket shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and made out of 1.6mm thick MS sheet) concealed in wall, 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switche and socket combination, wiring for one socket out let 15 Amps point controlled by one switch (on indipendent board), including provn of 2.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (combination switch/socket shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with 4 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and made out of 1.6mm thick MS sheet) concealed in wall, 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switche and socket combination, wiring for for one socket out let 15 Amps point controlled by one switch (on indipendent board), including provn of 4 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (combination switch/socket shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring (using red, black and green colour wires as colour coding for single phase circuits) complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and made out of 1.6mm thick MS sheet) concealed in wall, 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches, wiring for one light point controlled by two Nos two way switchs, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ).
Switch piano, flush type, single pole, two way, 6 Amp, fixed on laminated sheet top cover complete all as specified and as directed. Note :- Cost of plastic laminated sheet cover for mounting of switch is included under respective item of point wiring.
M&L for bell push piano flush button type, 5/6 Amps, 240 volts SP fixed on laminated sheet top cover complete all as specified and as directed. Note :- Cost of plastic laminated sheet cover for mounting of switch is included under respective item of point wiring.
Supply and fixing LED lamp minimum 3 star rated 5W LED B-22 base complete all as specified and as directed with following specifications of LED lamp;- (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : More than 70
Supply and fixing LED lamp minimum 3 star rated 9W LED B-22 base complete all as specified and as directed with following specifications of LED lamp;- (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : More than 70
Supply and fixing LED lamp minimum 3 star rated 12W LED B-22 base complete all as specified and as directed with following specifications of LED lamp;- (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : More than 70
Supply and fixing LED lamp minimum 3 star rated 3W LED B-22 base for engagement light any colour as directed complete all as specified and as directed with following specifications of LED lamp;- (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : More than 70
Wiring with TV coaxial RG-6 heavy duty PVC insulated sheathed cable with copper conductor having single strand of 0.7 mm dia and a aluminium wire net for TV antenna from terminal boxes to TV socket complete all as specified and as directed. (conduit pipe and fittings shall be measured and paid separately).
MS pressed steel box flush mounted 100mm x100mmx50mm having holes for 20 mm conduit entry including 2 pin TV socket outlet round flush type duly marked with symbol of TV and 3 mm thick plastic laminated sheet cover complete for TV connection complete all as specified and as directed..
Wiring with PVC insulated sheathed cable with copper conductor having single strand of 0.4 mm dia one pair taped for telephone wiring (for indoor application) from terminal box to telephone socket complete all as specified and as directed. (conduit and conduit accessories shall be measured and paid separately).
MS pressed steel box flush mounted 100mm x100mmx50mm having holes for 20 mm conduit entry including 3 pin telephone socket outlet flush type duly marked with symbol of telephone and 3 mm thick plastic laminated sheet cover complete for telephone connection complete all as specified and as directed.
M&L for Flame proof Point wiring with 1.5 Sqmm nominal area PVC insulated FRLSH unsheathed stranded copper conductor cable in and including ERW rigid conduit stove enamelled concealed conduit for one light point/Fan point with FP junction box, FP bend, FP reducer independent for 2 light points controlled by and including one MCB (2 point one light and one fan point controled by one point wiring and one MCB, MCB fixed in existing DB) including 1.5 Sqmm nominal area PVC insulated FRLSH unsheathed stranded copper conductor cable for earth wire to common earth and connected to earth dolly complete all as directed with and including the following items :- (a) Flame proof junction box 3 way suitable for 3/4'' ET conduit material LM-6. (b) Flame proof junction box 2 way suitable for 3/4" ET conduit material LM-6. (c) Flame proof bend suitable for 3/4"ET conduit material LM-6. (d) Flame proof union suitable for 20 mm dia ERW conduit.
Supply and hanging/fixing ceiling fan 1200 mm sweep AC supply 230V (Input Voltage range : 120 to 280 volts), BLDC type, Five star rated, BEE & ISI marked, super enamelled copper winding of 'B' class insulation, single phase 26W (+ 10%), PF 0.90 (Min), air delivery of 220 cum / minute (CMM), 350 RPM (+ 10%), temperature rise 40 degree maximum, without remote but including electronic regulator 5 Speed fixed on existing switch board, 3 Blades, down rod including aaccessories, white colour, total harmonic less than 10%, hanging in position including making connection with and including flexible cord twin core twisted copper conductor of size 23/0.0076 from ceiling rose to fan complete all as specified and as directed. Note :- (i) Fan regulator shall be measured and paid separately under appropriate item of Sch A (ii) Srl Number of ceiling fan and GE office name shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number shall be issued by Engineer-in-Charge.
Supply and hanging/fixing ceiling fan 1400 mm sweep, AC supply 230V (Input Voltage range : 120 to 280 volts), BLDC type, Five star rated, BEE & ISI marked, super enamelled copper winding of 'B' class insulation, single phase 33W (+ 10%), PF 0.90 (Min), air delivery of 245 cum / minute (CMM), 300 RPM (+ 10%), temperature rise 40 degree maximum, without remote but including electronic regulator 5 Speed fixed on existing switch board, 3 Blades, down rod including aaccessories, white colour, total harmonic less than 10%, hanging in position including making connection with and including flexible cord twin core twisted copper conductor of size 23/0.0076 from ceiling rose to fan complete all as specified and as directed. Note :- (i) Fan regulator shall be measured and paid separately under appropriate item of Sch A (ii) Srl Number of ceiling fan and GE office name shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number shall be issued by Engineer-in-Charge.
Supply and fixing exhaust fan BEE approved, energy saver/energy-efficient, 300 mm sweep metal body with louvres, 240V, 50Hz, single phase, mounted on wall in suitable opening arrangement with 4 Nos steel fastners 12mm dia 100mm long and making good the disturbed surface including making electrical connection with and including PVC insulated PVC sheathed copper conductor flexible cable 1.0 sqmm, 3 core from connector to fan complete all as specified and as directed. Note :- (i) Srl Number of exhaust fan and GE office name shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number shall be issued by Engineer-in-Charge.
LED complete fitting including batten and T-8 Retro LED polycarbonate 1 x 20 Watt, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications complete all as specified and as directed.:- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP-20. (g) CRCA pre coated housing with two coloured plastic end cap. (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : 6500K (m) CRI : More than 80 (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
LED complete fitting including batten and T-8 Retro LED polycarbonate 2 x 20 Watt, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications complete all as specified and as directed.:- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP-20. (g) CRCA pre coated housing with two coloured plastic end cap. (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : 6500K (m) CRI : More than 80 (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
LED light fitting 1 x 10 Watt, appx 2 feet long extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications complete all as specified and as directed :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-20. (g) CCT : 6500K (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CRI : More than 80 (m) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing recessed LED ceiling mounted with wide light window for maximised glare free output suitable for 600x600mm and ceiling cutout 595x595mm modular grid/POP ceiling finishes complete fitting with separate electronic driver and high brightness LED 36 Watt, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting and all accessories with following specifications and all as directed:- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP20. (g) CCT : 6500K (h) CRI : Morethan 80 (j) CRCA pre coated housing. (k) LED Driver of the make as of the luminaire. (l) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (m) Surge protection minimum 3 kV. (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing very high efficiency round highbay beam suspended, industrial LED light fittings of 80 W capacity Epoxy powder coated pressure die cast aluminium alloy housing and front cover clear toughned glass complete fitting with the following specifications:- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen/watt. (b) Input Voltage range:140 to 270 volts. (c) Temp operating range: minus 10°C to plus 50°C (d) Power factor : Minimum 0.95. (e) THD : Maximum 10%. (f) CRI : Minimum 70 and CCT : 5700 K. (g) IP rating: Minimum IP66. (h) IK rating: Minimum IK07 (j) Build in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protection viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens :- High efficiency wide angle lens (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing energy efficient LED street light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories and following specifications and all as directed. (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : Minimum 70 and CCT : 5700 K. (g) IP rating : IP66. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Brackets made out of GI tubing light grade 32mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 50x3 mm for fixing of bracket along wall with suitable nuts and bolts (nut bolt grouting with PCC in wall) including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Supply and fixing LED light fitting 15watt flame proof, CMRI certified recommended for gas/vapour group of IIA &IIB and Zone 1&2 and IP65 Protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size and wall /surface mounted all as specified and directed. Make : Model-Radiance cat part.no IBFN100-15-CDL of make CromptonGreaves or Equivalent in Sudhir / Bajaj / Shyam .
Supply and fixing single phase flame proof Exhaust fan of size 305 mm with 1440 RPM ,1120CFM with louver shutter in aluminium die cast LM6 of gas group IIA & IIB , certified by CMRI Dhanbad including all accessories complete all as specified and as directed. Make :- Sudhir cat part.no EF/140 or equivalent in CG / Bajaj / Shyam.
Supply and fixing (concealed in wall) factory made DB (made out of CRCA sheet duly powder coated) SPN, 10 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting/provision of RCBO / MCB / MCCB / Isolator etc, as incomer and outgoing, conforming to IS-8623, BS-5484 dust and vermin proof complete all as specified and as directed. Note :- RCBO / MCB / MCCB / Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed in wall) factory made DB (made out of CRCA sheet duly powder coated) VTPN, 4 Way, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting/provision of RCBO / MCB / MCCB / Isolator etc, as incomer and outgoing, conforming to IS-8623, BS-5484 dust and vermin proof complete all as specified and as directed. Note :- RCBO / MCB / MCCB / Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCB SPN 40 Amps, ‘C’ curve, 240 volts, with over load and short circuit protection, rupturing capacity not less than 10 KA, complete all as specified and as directed.
Supply and fixing MCB SPN 30/32 Amps, ‘C’ curve, 240 volts, with over load and short circuit protection, rupturing capacity not less than 10 KA, complete all as specified and as directed.
Supply and fixing MCB SPN 25 Amps, ‘C’ curve, 240 volts, with over load and short circuit protection, rupturing capacity not less than 10 KA, complete all as specified and as directed.
Supply and fixing MCB SPN 20 Amps, ‘C’ curve, 240 volts, with over load and short circuit protection, rupturing capacity not less than 10 KA, complete all as specified and as directed.
Supply and fixing MCB SPN 16 Amps, ‘C’ curve, 240 volts, with over load and short circuit protection, rupturing capacity not less than 10 KA, complete all as specified and as directed.
Supply and fixing MCB SPN 10 Amps, ‘C’ curve, 240 volts, with over load and short circuit protection, rupturing capacity not less than 10 KA, complete all as specified and as directed.
Supply and fixing MCB SPN 06 Amps, ‘C’ curve, 240 volts, with over load and short circuit protection, rupturing capacity not less than 10 KA, complete all as specified and as directed.
Supply and fixing MCB SP 06 to 32 Amps, ‘C’ curve, 240 volts, with over load and short circuit protection, rupturing capacity not less than 10 KA, complete all as specified and as directed.
Supply and fixing MCB SP 40 Amps, ‘C’ curve, 240 volts, with over load and short circuit protection, rupturing capacity not less than 10 KA, complete all as specified and as directed.
Material and labour for concealed sub main wiring (Two run for main i.e. phase and netural and one run for continues as earth wire connected to earth dolly etc.) with 2.5 Sqmm single core FRLSH PVC insulated multistrand copper conductor cable drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit.
Material and labour for concealed sub main wiring (Two run for main i.e. phase and netural and one run for continues as earth wire connected to earth dolly etc.) with 6 Sqmm single core FRLSH PVC insulated multistrand copper conductor cable drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit.
Material and labour for concealed sub main wiring (Two run for main i.e. phase and netural and one run for continues as earth wire connected to earth dolly etc.) with 10 Sqmm single core FRLSH PVC insulated multistrand copper conductor cable drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit.
Material and labour for concealed sub main wiring (Four run for main i.e. phase and netural and one run for continues as earth wire connected to earth dolly etc.) with 4 Sqmm single core FRLSH PVC insulated multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), on independent circuit from DB including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed. Note :- Five runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit.
Material and labour for concealed sub main wiring (Four run for main i.e. phase and netural and one run for continues as earth wire connected to earth dolly etc.) with 6 Sqmm single core FRLSH PVC insulated multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), on independent circuit from DB including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed. Note :- Five runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit.
Material and labour for concealed sub main wiring (Four run for main i.e. phase and netural and one run for continues as earth wire connected to earth dolly etc.) with 10 Sqmm single core FRLSH PVC insulated multistrand copper conductor cable drawn through and including PVC conduit 32mm dia (medium quality ISI marked), on independent circuit from DB including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed. Note :- Five runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit.
Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as directed. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and earthing wire from top of earth plate upto electric equipment from top of earth plate i.e. minimum 7.5 metre shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Subtotal
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’ Section - III (Part-I)
Sch 'A' Sec - III (Part-II) (INTERNAL WATER SUPPLY WORKS)
S&F Angle cock, cast copper alloy,chromium plated, screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions suitable for 15mm nominal bore iron pipe and fixed complete all as specified.
Subtotal
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORKS” as listed in Schedule ‘A’ Section - IV (Part-I)
SCHEDULE 'A' SECTION- IV (Part-II) (SEWAGE DISPOSAL WORKS)
Supply and laying DWCPE (SN8) pipes 150 mm dia (inner) confirming to IS-16098(Part-II) complete laid in trenches and jointed including testing with and including necessary jointing material tees/ union/ socket etc complete as per manufacturers instructions. NOTES:- (i) Earth work and bed of pipe shall be measured & paid for separately under respective items of Schedule 'A'/BoQ. (ii) The rate of necessary tees/ union/ socket/ other accessories of same material and size of pipe is included in this item and nothing shall be paid extra on this account.
Supply and laying DWCPE (SN8) pipes 200 mm dia (inner) confirming to IS-16098(Part-II) complete laid in trenches and jointed including testing with and including necessary jointing material tees/ union/ socket etc complete as per manufacturers instructions. NOTES:- (i) Earth work and bed of pipe shall be measured & paid for separately under respective items of Schedule 'A'/BoQ. (ii) The rate of necessary tees/ union/ socket/ other accessories of same material and size of pipe is included in this item and nothing shall be paid extra on this account.
Subtotal
Lump sum price worked out by the tenderer for “BITUMINOUS ROAD, PCC ROAD, PATH AND CULVERT WORK" as listed in Schedule ‘A’ Section - V (Part-I)
Sch 'A' Sec - V (Part-II), (BITUMINOUS ROAD, PCC ROAD, PATH AND CULVERT WORK)
Road marking/painting 3mm thick film as lines, dashes, arrows etc. using Hot applied retro-reflective thermoplastic road marking paint (in any colour as direccted like white, golden, yellow, orange black etc.) confirming to MORT & H (clause 803.4) with 8% glass beads, using special applicator machine with heating arrangement upto 160 °C including cleaning and drying the existing surface to ensure dust free and moisture free surface before applying the paint complete all as specified and as directed.
Material and labour for 150mm thick M-25 (design mix), using 20 mm graded stone aggregate as in paving/path etc, in panels size as directed with provision of joints including setting the material by vibrating with using mechanical plat vibrator and top of surface finished even & smooth without using extra cement including necessary form work complete all as specified and as directed. NOTE : (i) Filling of expansion and constuction joints shall be measured and paid separately under appropriate item of BOQ.
60 mm thick (M35 grade) precast interlocking tile/paving block factory casted (made by using PVC/ Rubber moulds on Vibrating Table Machine) using grey cement and no pigment, shape haxagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over and including 25mm thick layer of sand and filling the interstices etc with sand complete all as specified and as directed.
Factory made kerb stone, quoin blocks, boundary pillars etc of size as directed with plain fair faces, chamfers, weatherings, slightly rounded or chamfered angles etc made by using PVC / Rubber moulds on Vibrating Table Machine with grey cement and no pigment with PCC M-20, nominal mix, laid and setting in cement mortar (1:4) complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “COMPOUND WALL AND STEEL GATE WORKS" as listed in Schedule ‘A’ Section - VI
Lump sum price worked out by the tenderer for “Area drainage work " as listed in Schedule ‘A’ Section - VII
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - VIII (Part-I)
Sch 'A' Sec - VIII (Part-II) (EXTERNAL WATER SUPPLY WORKS)
Material and labour for tapping from existing DI pipe line to GI pipes of any size for branch conncetion including all fixtures and fittings like ferrule, clamps, nut bolts etc as per site requirement including drilling/cutting/threading etc and including excavation and earth work complete all as specified and as directed.
Construction of brick masonary valve pit chamber size 90 X90 X90 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:4) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed and shown on drawings.
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL ELECTIC SUPPLY WORKS" as listed in Schedule ‘A’ Section - IX (Part-I)
Sch 'A' Sec - IX (Part-II), (External Electrification Works)
Sand cushioning, with dry and clean fine river sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. (Note:- Punned thickness shall be considered for payment purpose)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed.
Supply & install, testing and commissioning of factory made, factory made LT panel outdoor KIOSK type with double doors of suitable size provided with locking arrangements dust, weather and vermin proof 1100 volt grade, 50 Hz AC made out by 3.15 mm thick CRCA sheet steel for load bearing and 2 mm thick for non load bearing, fully compartmentalised, with IP-54 protection all as per conforming to IS: 2417 of 1962 complete with and 50x50x5 mm thick angle iron for frame and legs, 04 Nos. legs 750 mm long 450 mm grouted in PCC blocks of type B-1 (1:2:4) with 300 mm ground clearance, for 415 volts, 3 phase, 4 wire AC supply complete all as directed with and including the following :-
MCCB 4 pole 415 Volt, 160 Amps ,Adjustable thermal and adjustable magnetic setting , Ics = 100% Icu, Adjustable overload setting Lr = (0.8 to 1.0)xln of rupture capacity 25 KA - 01 No (incoming)
MCCB 3 pole 415 Volt, 100 Amps ,Adjustable thermal and adjustable magnetic setting , Ics = 100% Icu, Adjustable overload setting Lr = (0.8 to 1.0)xln of rupture capacity 16 KA outgoing - 01 Nos
MCCB 3 pole 415 Volt, 63 Amps ,Adjustable thermal and adjustable magnetic setting , Ics = 100% Icu, Adjustable overload setting Lr = (0.8 to 1.0)xln of rupture capacity 16 KA outgoing - 01 Nos
MCB TPN 32 Amps - 02 Nos (outgoing)
Aluminium strip bus bars with colour code PVC insulation 250 Amps capacity FP mounted on epoxy insulators - 01 Set
Indicators RYB - 01 Set
Earthing terminals and cable glands.
Internal wiring of panel board with solid coductor copper cable single core of sutable size and incl 03 Nos bakelite control fuses.
Danger notice plate for LT with conventional skull and bones duly rivetted/pasted to the panel board door.
Supply & install, testing and commissioning of factory made, factory made LT panel outdoor KIOSK type with double doors of suitable size provided with locking arrangements dust, weather and vermin proof 1100 volt grade, 50 Hz AC made out by 3.15mm thick CRCA sheet steel for load bearing and 2mm thick for non load bearing, fully compartmentalised, with IP-54 protection all as per conforming to IS: 2417 of 1962 complete with and 50x50x5 mm thick angle iron for frame and legs, 04 Nos. legs 750 mm long 450 mm grouted in PCC blocks of type B-1 (1:2:4) with 300 mm ground clearance, for 415 volts, 3 phase, 4 wire AC supply complete all as directed with and including the following :-
MCCB 4 pole 415 Volt, 100 Amps ,Adjustable thermal and adjustable magnetic setting Ics = 100% Icu, Adjustable overload setting Lr = (0.8 to 1.0)xln of rupture capacity 25 KA incoming - 01 No
MCCB 3 pole 415 Volt,63 Amps ,Adjustable thermal and Adjustable magnetic setting rupture capacity 16 KA -01 No (outgoing to FP3)
MCCB 3 pole 415 Volt, 32 Amps ,Adjustable thermal and adjustable magnetic setting Ics = 100% Icu, Adjustable overload setting Lr = (0.8 to 1.0)xln ofrupture capacity 16 KA outgoing - 02 Nos
MCB SPN, C curve, 6 -32 Amp 240 Volt 50 Hz- 09 Nos
Digital time switch, single phase with contactor - 01 No
Aluminium strip bus bars with colour code PVC insulation 150 Amps capacity FP mounted on epoxy insulators - 01 Set
Indicators RYB - 01 Set
Earthing terminals and cable glands.
Internal wiring of panel board with solid coductor copper cable single core of sutable size and incl 03 Nos bakelite control fuses.
Danger notice plate for LT with conventional skull and bones duly rivetted/pasted to the panel board door.
Supply & install, testing and commissioning of factory made, factory made LT panel outdoor KIOSK type with double doors of suitable size provided with locking arrangements dust, weather and vermin proof 1100 volt grade, 50 Hz AC made out by 3.15mm thick CRCA sheet steel for load bearing and 2mm thick for non load bearing, fully compartmentalised, with IP-54 protection all as per conforming to IS: 2417 of 1962 complete with and 50x50x5 mm thick angle iron for frame and legs, 04 Nos. legs 750 mm long 450 mm grouted in PCC blocks of type B-1 (1:2:4) with 300 mm ground clearance, for 415 volts, 3 phase, 4 wire AC supply complete all as directed with and including the following :-
MCCB 4 pole 415 Volt, 63 Amps ,Adjustable thermal and adjustable magnetic setting Ics = 100% Icu, Adjustable overload setting Lr = (0.8 to 1.0)xln of rupture capacity 16 KA incoming - 01 Nos
MCCB 3 pole 415 Volt, 32 Amps ,Adjustable thermal and adjustable magnetic setting Ics = 100% Icu, Adjustable overload setting Lr = (0.8 to 1.0)xln of rupture capacity 16 KA outgoing - 01 Nos
MCB SPN, C curve, 6 -32 Amp 240 Volt 50 Hz- 08 Nos
Digital time switch, single phase with contactor - 01 No
Aluminium strip bus bars with colour code PVC insulation 100 Amps capacity FP mounted on epoxy insulators - 01 Set
Indicators RYB - 01 Set
Earthing terminals and cable glands.
Internal wiring of panel board with solid coductor copper cable single core of sutable size and incl 03 Nos bakelite control fuses.
Danger notice plate for LT with conventional skull and bones duly rivetted/pasted to the panel board door.
Supply & install, testing and commissioning automatic power factor control (APFC) panel outdoor type self standing front operated, of capacity 100 KVAR in 7 steps with microprocessor based control realy, it should be factory made of suitable size, dust and virmin proof with IP 54 protection class, fully ventilated front and rear side openable and favricated out of MS CRRA sheet 3 mm thick for outdoor and 2 mm thick for indoor with base angle iron of frame 50x50x5 mm. THe panel shall be painted with two coats of powder coating after properchemical prtreatment of sheet steel. THe panel shall be provided with suitable size lugs and cable glands for incoming & control cables, grouted in PCC bloxks of type B-1 (1:2:4) using 20 mm graded stone aggragate with 300 mm ground clearance complete all as specified and directed. The panel shall be comprising of the following:-
MCCB 200 Amps, 4 pole, Ics = 100% Icu, Adjustable overload setting Lr = (0.8 to 1.0) xln of rupturing capacity 25 KA adjustable thermal and magnetic release - incoming
Copper bus bar TPN, insulated with colour coded head shrinkable sleeve insulation of 300 amps capacity rating.
MCBs TP-63A - 01 No, 40A - 02 Nos, 32A - 01 No, 20A - 01 No & 10A - 02 Nos
Capacitor duty contractor of each rating of capacitors - 07 Nos
Capacitor MPP (HD) - 07 Nos (25 X 1 + 20 X 2 + 15 X 1 + 10 X 1 + 5 X 2= 100KVAR)
APFC relay with (7+1) spare) 08 stages -01 No
LED indicating lamp R-Y-B - 03 Nos
One set of curent transformer (CTs) of suitable rationo (with secondary of 05 Apms) to be fixed on bus bars of existing panel including connection with 2 core 1.5 Sqmm armoured copper conductor cable complete with gland etc.
Note for srl item No 80 to 83 :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip of size 32 x 6 mm flat by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as directed. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and earthing strip upto electric equipment from top of earth plate i.e. minimum 7.5 metre shall be included in the unit rate of this item. (iii) Test point if required as per site requirement, same shall be measured & paid separately. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fixing energy efficient LED street light fitting of 45W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories and following specifications and all as directed:- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : Minimum 70 and CCT : 5700 K. (g) IP rating : IP66. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Brackets made out of GI tubing light grade 32mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 50x3 mm for fixing of bracket on steel tubular/ PCC poles with suitable nuts and bolts including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Junction box of size 200x160x98mm/200x140X95mm or any other higher size (pole mounting) and should be insulated and made out of polycarbonate with glass fiber re-inforced material having IP66 protection in accordance with IEC 60529, fixing with and including clamp made out of MS Flat iron size 25x3 mm including suitable size of nuts, bolts and washers including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer complete comprising of the following and as directed:- Note :- (a) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60670-22, IEC-60670-22, IEC 60670-2 to 5 and color according to RAL 9011. (b) The manufacturer of junction box shall submit a copy of IEC certificate. (c) Junction box shall be fire retardant and self extiguishing in accordance with IEC60695-2to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard. It should be tested at Glove Wire test for 960°C. (d) The degree of protection of enclosure against mechanical load shall be in accordance with EN 50298 for IK08. (e) Internally embedded gasket of polyurethane. (f) Junction box shall 4 pole complete with single pole MCB 'C' curve of 6 Amp, rating.
Material and labour for providing in existing LT panel (installed near 300 KVA transformer) aluminium bus bar having carrying capacity 600Amp fixing with insulator and nut bolts and colour coding insulated and including one No MCCB 415 volts, FP, 200 Amps, thermal magnetic release rupturing capacity 25KA, complete all as specified and as directed.
Supply and fixing 9 watt cylindrical shape, integral decorative LED Bollard light with Opal acrylic, made in 3 parts i.e. spun aluminium dome shaped top cover, cylindrical opel acrylic diffuser for pleasant light output and seamless GI pipe bottom housing the control gear for 9W LEDs complete fitting with all accessories and LEDs, including fixing arrangement with material as directed by Engineer-in-charge including making electric connections, complete all as specified and as directed and as per the following specifications:- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CCT : 3000 K. (g) IP rating : IP65. (h) Built in LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 4.5 kV (l) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing LED Post top light fitting 40 watt, made of cast aluminium spigot housing with decorative clear opel acrylic diffuser, Glare-free and better uniformity, complete fitting with all accessories and LED lamp, including fixing arrangement with material as directed by Engineer-in-charge including making electric connections, complete all as specified and as directed and as per the following specifications:- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : Minimum 70 and CCT : 5700 K. (g) IP rating : IP65. (h) IK rating : Minimum IK07 (j) Built in LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing 1100 Volt grade, flexible PVC insulated, sheathed , multi strand copper conductor cable of size 1.5 Sqmm flat/round three core for connection of street light fitting from junction box to light fittings / service connection drawn through pipe including making connections complete all as specified and as directed. Note ;- Pipe shall be measured and paid separately under respective item of BOQ.
Supply and fixing mild steel stove enamelled conduit of size 20 mm dia fixed along PCC/steel tublar street light pole with clamps made out of MS Flat iron size 25x3 mm at not more than 100cm c/c matching with section of pole, including bends, elbows and suitable size of nuts, bolts and washers including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed. (Cable shall be measured and paid separately under appropriate item of BOQ)
Excavation by trenchless technology for boring of holes under road, pavement, hardstanding using trenchless boring machine or by means of manual manpower suitable for inserting GI pipe including removal of surplus soil and making good disturbed surface complete all as specified and as directed. NOTE:- Pipe for inserting as required shall be measured and paid for separately.
Subtotal
Lump sum price worked out by the tenderer for “HOT WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - X (Part-I)
Sch 'A' Sec - X (Part-II), (HOT WATER SUPPLY WORKS)
Supply, installation, testing and commissioning of 'Solar hot water system of capacity 300 ltrs per day' including flat plate collector and other required accessories and insulated stainless steel storage water tank to be placed on building roof at a suitable height with aluminium cladding angle iron structure cold water tank with inter connection between tank and solar panel and necessary structure and finishing work, foundation including electric back up of 3 KW and electric panel with MCBs and other safety devices such as thermostat relays etc., complete all as specified and as directed. NOTES (i) Quoted rate deems to be inclusive cost of stainless steel hot water tank, cost of fabrication & errection of tank staging for cold backup water tank & hot water storage tank using 50x50x6mm MS angle iron sections & 50x5mm MS flat iron duly painted with two coats of aluminium paint over a coat of red oxide primer. (ii) Cold water piping, hot water piping, cold water tank, electric wiring up to solar panel, MCB and DB shall be measured and paid separately under respective items of Sch 'A'. (iii) Solar water heater shall be installed by the authorised representative of the manufacturer only.
Rotational moulded three layer polyethylene water storage tank of capacity 500 litre cylindrical vertical with closed top conforming to IS-12701-1996 hoisted and fixed in position complete all as specified and as directed. (qty 01 for hot water supply and 02 for summer appliances)
Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated flexible multistranded copper conductor 1100 V grade 4 Sq.mm (03 run i.e 2 runs for main phase and nutral, 01 run for earthing) drawn through and including 20mm bore PVC rigid conduit (heavy duty, ISI marked) fixed along wall/pillar surfaces including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal etc., complete all as specified and as directed. NOTE:Three runs of copper conductor and one run of PVC conduit including accessories shall be measured and paid as one unit.
Subtotal
Lump sum price worked out by the tenderer for “SUMMER APPLIANCES WORKS" as listed in Schedule ‘A’ Section - XI (Part-I)
Sch 'A' Sec - XI (Part-II), (SUMMER APPLIANCES WORKS)
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 150V to 280V with working input voltage stabilized at 230 V with accuracy of ± 2.5%, 2-4 mts const delay with capacity 6 Amps complete all as specified and as directed.
Supply and fixing desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour, factory made Gi sheet body 18 SWG and side panells of 22 SWG, water sump capacity not less than 40 ltrs including making water connection complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “Excavation and Earth work" as listed in Schedule ‘A’ Section - XII (Part-I).
Sch 'A' Sec - XII (Part-II), (EXCAVATION AND EARTHWORK)
Supplying and stacking of good earth at site brought from out side MOD (from 5 Km to 10 Km lead) including loading, unloading, royality, taxes and carriage for all leads and lifts complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “Dismantling/ Demolition work" as listed in Schedule ‘A’ Section - XIII, (Part-I).
Sch 'A' Sec - XIII, (Part-II) (DISMANTLING/DEMOLITION AND MISC WORKS )
Taking down old unserviceable flushing cistern any type complete all as directed.
Taking down old steel ventilator complete all as directed.
Preparation and submission of completion record drawings (both architectural and structural, showing plan, front elevation, rear elevation and both side views) of buildings at srl No 01 to 21 of Sch 'A' Sec-I duly incorporating changes, if any during execution and provision of respective TD drawings on computer based AUTOCAD software and shall be submitted to Engineer-in-charge in print copy on tracing paper of approved quality and size as directed and also in digital form in CD with total 5 sets each complete all as directed. Note :- These shall be signed by Engineer-in-charge and GE in token of their check.
Preparation and submission of completion record drawings (showing all internal services routes) of buildings at srl No 01 to 21 of Sch 'A' Sec-I duly incorporating changes, if any during execution and provision of respective TD drawings on computer based AUTOCAD software and shall be submitted to Engineer-in-charge in print copy on tracing paper of approved quality and size as directed and also in digital form in CD with total 5 sets each complete all as directed. Note :- These shall be signed by Engineer-in-charge and GE in token of their check.
Preparation and submission of PSMB (periodical services measurement book) of buildings at srl No 01 to 21 of Sch 'A' Sec-I duly recorded all measurement in details of all the periodical services executed as per schedule of finishes. Print copy of PSMB in well binded (Register type) of approved quality and also in digital form in CD shall be submitted to Engineer-in-charge complete all as directed. Note :- (i) These shall be signed by Engineer-in-charge and GE in token of their check. (ii) Performa/ pattern of PSMB shall be as given by GE.
Subtotal
Dasmesh Buildcon
Sood Enterprises
M/s Khanna Enterprises
SOM BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .