Loading…
Loading…
Tender Value
₹6.8 Cr
EMD Value
₹13.5 L
Closing Date
27 Jul 2026, 5:00 pm
MUKESH KUMAR
SUPERINTENDENT ENGINEER
CONSTRUCTION OF POLICE STATION BUILDING (G+3 STRUCTURE) AT TILKAMANJHI POLICE STATION WITH ELECTRIFICATION IN THE DISTRICT OF BHAGALPUR
135271
NIT-07/SBD/2026-27/GR-05
Open Tender
GENERAL
Patna
• Legal Status of Bidder
• Place of Registration
• Litigation History
• Registration No
• PAN No.
• GSTIN
• Character Certificate (with Letter No. Letter Date, Issuing Office)
• Electrical License Validity upto (in case of sub-contractors affedevit of both the parties)
• NOC for Debar (if required)
GENERAL
PERCENTAGE
L1
1
21 documents required · 21 mandatory
₹10,000
Processing Fee: 11800
₹13.5 L
CE, BPBCC, Patna
4 Jul 2026
4 Jul 2026
29 Jul 2026
4 Jul 2026
27 Jul 2026
4 Jul 2026
9 Jul 2026
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size.) ( Shelves)
Centring and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roots, landings, balcnies and access platform.
Centring and shuttering including strutting, propping etc. and removal of form for: Shelves (Cost in situ)
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Centring and shuttering including strutting, propping etc. and removal of form for: Stairs,(excluding landings) except spiral-staircaces.
Centring and shuttering including strutting, propping etc. and removal of form for: Weather shade,Chajjas, corbels etc. including edges
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 10mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 16mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 20 mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 25 mm dia.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:Add or deduct for providing richer or leaner mixes respectively at all floor levels: Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Walls columns, pillars, posts cind struts: Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.:Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) : Extra tor Brick work in superstructure above plinth level upto floor V cum
Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level. Cement mortar 1 : 3 (1 cement : 3 coarse sand)
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly. plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. but excluding carriage cost of bricks, sand and jhama metal.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite of any colour and shade:Area of slab over 0.50 sqm.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30 mm thick including stainless steel butt hinges with necessary screws.
Providing and fixing M.S. grills of requirement pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete: Fixed to steel windows by welding.
Providing and fixing alluminium sliding door bolt anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to rquired colour and shade with nuts and screws etc. complete : 300 x 16mm
Providing and fixing alluminium sliding tower bolt anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc. complete : 300 x 10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete: 125mm
Providing and fixing alluminium hanging floor door stopper anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete : Twin rubber stopper
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multichambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc.
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multichambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc.
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer.
Providing and fixing pressed steel door confirming IS code 351 manufactured from commercial mild steel sheet of 1.25 mm thickness including higes, jamb, lock jamb , bead and if required angle threshold of mild steel angle of section 50 x 25 mm or base ties of 1.25 mm pressed mild steel welded or rigidly fixed together by mechinical means, adjustable lugs with split end tail to each jam including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge. Profile B, Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete.
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel, etc as required: In gratings, frames, guard bar, ladders, railing, brackets, gets & similar works.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
Chequered terrazo tiles 22 mm thick with marble chips of sozes upto 6 mm in floors jointed with neat cement slurry mixed with pigement to match the shade of the tiles, including rubbing and polshing complete on 20 nm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) : Medium shade using 50% white cement and 50% ordinary cement.
Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with: Makrana white second quality.
Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with: Black Zebra marble.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300 x 300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying vitrifed floor tiles in different sizes { thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete: Size of Tile 60 x 60 cm.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete : Size of Tile 600 x 600 mm.
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Shoe
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 110mm dia clip
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diametre and weighing not less than 440 grams.
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
12mm cement plaster of mix: 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying primer coat : With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanised iron/steel works:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm, modulus of elasticity 900 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for Separately).
Providing and fixing factory made single extruded WPC {Wood Polymer Composite} solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibers {wood powder/ rice husk/wheat husk) and non toxic additives {maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800N {Face) & 900N (Edge), minimum compressive strength 50 N/mm, modulus of elasticity 850 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In• Charge. {Note:stainless steel butt hinges and necessary S.S screws shall be paid separately) 35 mm thick
Supplying fitting and fixing 24 gauge thick Aluminum sheet of approved quality over wooden surface of door shutters including cost of nails its all complete job as per building specification and direction of E/I.
Per bag
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level : 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)( Foundation, Band at P.L.& S.Tank Cover)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Brick work with fly ash bricks as per IS 12894 (2002) & IS 3495 in foundations and plinth in : Cement mortar 1:4(1 cement : 4 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 75mm diameter
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75 x 75 x 75mm dia Single Jn Tee with door
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee with door
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee without door (T. Bend)
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm dia Plain bend : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diametre and weighing not less than 440 grams.
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 75mm dia clip
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 110mm dia clip
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
12mm cement plaster of mix: 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS :7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P.brass pillar tap
Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete,including painting the fittings and brackets, cutting and making good the walls wherever required : White glazed fire clay kitchen sink of size 600x450x250 mm
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 coarse sand 6 graded stone aggregate 20 mm nominal size) including disposal of malba.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20x20 mm square bar
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality:LD 2.5:Rectangular shape 600x450 mm internal dimensions
Constructing brick masonry chamber for underground C.I.Inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg),R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing brick bats and filling the same in soak pit as per specificarion and direction of engineer in charge.
Per bag
DESCRIPTION
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5 mm glass shelf with edges round off,supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Concealed work, including cutting chases and making good the : 15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Concealed work, including cutting chases and making good the : 20 mm nominal outer dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:32 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:32 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) :32 mm nominal bore:Horizontal
Providing and fixing gun metal non- return valve of approved quality (screwed end) :32 mm nominal bore:Vertical
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete :20 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete :25 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete :32 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms: 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:15 mm nominal bore
Providing and fixing PTMT swivelling shower, 15 mm nominal bore,
Cutting holes up to 30x30 cm in walls including making good the same:With common burnt clay F.P.S. (non modular) bricks
DESCRIPTION
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:32 mm dia nominal bore
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge,upto 90 metre depth below ground level:All types of soil:300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge:100 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818,including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge:100 mm nominal size dia
Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-incharge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/casing pipe, removable as per requirement, all complete for borewell of:100 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete:100 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I): 100 mm dia
Per Set
Per Set
DESCRIPTION
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.l. box etc as required. Group B
Wiring for light/Power plug with 2x4 Sq.mm FR PVC insulated Copper conductor single core cable in surface recessed PVC conduit along with 1 No. 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. CKT- (2 x2.5mm2 + 1x2.5 mm2 earth wire)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain (4x6.0 mm2 + 1x6.0mm2)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain (4x16 mm2 + 1x16 mm2)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/,switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 2 Pin, 6 amps ceilling rose on the existing Junction box / wooden block including connection etc. as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required' lOO A, 30 KA, FPMCCB
Providing and fixing following rating & breaking capacity MCCB in existing cubicle panel board, including drilling holes in cubicle panel, making connections, etc. as required. 250 A, 50 KA, FPMCCB
Providing and fixing following capacity busbar Chamber with 4 strips of suitable size made of copper, heavy duty complete with all accessories including connections, earthing the body etc. as required. 100 Amps.
Providing and fixing following capacity busbar Chamber with 4 strips of suitable size made of copper, heavy duty complete with all accessories including connections, earthing the body etc. as required. 400 Amps.
Providing and fixing following capacity 4 pole ON-load/panel mounted changeover switches inside the existing cubicle panel board including drilling holes in cubicle panel making connections etc. as required. 200 amps, four pole
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required, (But without MCB/RCCB/lsolator) 4 way ( 4 + 12 ), Double door, horizontal type
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 6 A to 32'A, Single pole
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 40 A to 63 A,.TP
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 40 A to 63 A, TP&N
Providing and fixing M.V. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for eafth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Supplying and fixing 4'X18 wat[ LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS pVC insulate copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 Im/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required. 18 watt
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 90 watt
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required. 9/10 watt LED lamp
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 95 sq.mm and upto 185 sq.mm.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 120 sq. mm, 3.5 core
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep
20 mm X 3 mm copper tape ( 0.533 kg/mtr)
Providing and fixing following capacity busbar Chamber with 4 strips of suitable size made of copper, heavy duty complete with all accessories including connections, earthing the body etc. as required. 63A
2.5 sq. mm lSl marked, FRLS PVC insulated single core copper conductor cable
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for eafth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Providing and fixing of lightning conductor final made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes tec. Complete as required.
Providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as required. (For Horizontal run)
Providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as required. (For vertical run)
DESCRIPTION
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. CKT- (2 x2.5mm2 + 1x2.5 mm2 earth wire)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. CKT- (2 x4.0mm2 + 1x4.0 mm2)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain- (2 x6.0 mm2 + 1x6.0 mm2 earth wire)
Supplying and fixing suitable size metal./pvc. box of 150 mm x 75 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connections, painting etc. as required.
Supplying and fixing suitable size metal./pvc. box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connections, painting etc. as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed PVC conduit as required. 1 run of cable
Providing and fixing following capacity double pole/ four pole OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board, including drilling holes in metal panel, making connections etc. as required. 63 A, double pole
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCBilsolator) 5 way, Double door
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 6 A to 32'A, Single pole
Supplying and fixing following rating double pole, 240 voltas Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for eafth electrode to fill up the excavated earth and earth inspection pit etc. as required.
DESCRIPTION
Supplying and drawing following size of FR PVC insulated copper conductor, single core cable in the existing surface/recessed PVC conduit as requirjed: 2 x 1.5 sq.mm
Providing and fixing following capacity double pole/TP&N sheet metal switch disconnector fuse unit in existing metel board with rewireable type fuses, including drilling holes in metal board, making connections etc. as required. 32 Amp double pole
Earthing with GI earth pipe 4.5 meter long and 40 mm dia including accessories, and providing masonary enclosures with cover plate having locking arrangment and watering pipe etc.with charcoal and salt as required .
Providing and laying earth connection from earth electrode with 6 SWG dia G.I.wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and refilling etc. as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 90 watt
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq.mm.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 6 sq. mm, 4 core
Supply and erection of 7 metre height Hot-dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia A/F 155 mm, made of 3 mm thick sheet along with base plate of size 260 X 260 X 16 mm , small door opening for junction box mounting including 64 'C' series SP MCB, conneclor, and suitable size foundation bolts with template as required.(but without pole foundation)
Providing, laying and fixing of following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required 50 mm dia
DESCRIPTION
Supplying and fixing fotrlowing types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on poleibuilding including connection earthing the body etc as required.200 watt
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq.mm.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 25 sq. mm, 3.5 core
Supply of 16/20 mtr High Mast lighting system with accessories as per design and drawing foundation bolt, aviation light and automatic on/off control panel etc all complete (Reputed Co and ISI/Iso)
Erection and commissioning with High Mast with suitable equipment, design and casting of shallow foundation with M20 concrete for High Mast I.E earthing etc as required.
Making good the above PCC of above trench with required materials cement sand graded stone (1:3:6)
DESCRIPTION
DESCRIPTION
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
Centring and shuttering including strutting, propping etc.and removal or form work for Foundations,footings, bases Columns
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing designation 100A one brick on edge soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Per bag
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level : 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement. 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form for: foudations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 10mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) : Extra tor Brick work in superstructure above plinth level upto floor V cum
Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level. Cement mortar 1 : 3 (1 cement : 3 coarse sand)
Welding by electric plant incluidng transportation of electric welding plant at site etc. complete.
Drilling 6mm dia in M.S.angle iron for fixing of staples etc.as per building specification and direction of E/I.
Labour for cutting M.S.angle iron post to required length, one and splitted as fish tailed in a length of 150mm complete as per building specification and direction of E/I.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Applying primer coat : With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanised iron/steel works:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Supplying M.S. Angle as per IS: 226 size 50 x 50x 6mm
Per bag
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level : 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement. 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form for: foudations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 16mm dia.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Applying primer coat : With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanised iron/steel works:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Per bag
DESCRIPTION
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
DESCRIPTION
Plantation work (10 gram DAP and pesticide per plant). Transportation of plant and planting work from temporary plant salad. Plantation 20 man days, Transportation of Plant- 6 man days, DAP-260/- persicide 100 Rs. Etc-50/-
Provision for plant transportion by tractor.
Providing bomboo barricating
Purchase of earth and round 152.5 [email protected]/cft per% no plants.
Labour for planting.
(A) Suppling and providing plants all as following details (10 plant's)
(B) Suppling and providing plants all as following details (10 plant's)
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roots, landings, balcnies and access platform.
Centring and shuttering including strutting, propping etc. and removal of form for: Shelves (Cost in situ)
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Centring and shuttering including strutting, propping etc. and removal of form for: Weather shade,Chajjas, corbels etc. including edges
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 10mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 16mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 20 mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 25 mm dia.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:Add or deduct for providing richer or leaner mixes respectively at all floor levels: Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Walls columns, pillars, posts cind struts: Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.:Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) : Extra tor Brick work in superstructure above plinth level upto floor V cum
Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level. Cement mortar 1 : 3 (1 cement : 3 coarse sand)
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly. plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. but excluding carriage cost of bricks, sand and jhama metal.
Providing and fixing flush door shutters conforming to IS : 2202 (Part-I) non-decorative type.core of block board construction with frame of 1st class tiard wood and well mathched commercial 3 ply veneering wiih vertical grains or cross bands and face veneers on both faces of shutters : 30 mm thick including anodized aluminum butt hinges with necessary screws.
Providing and fixing M.S. grills of requirement pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete: Fixed to steel windows by welding.
Providing and fixing alluminium sliding door bolt anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to rquired colour and shade with nuts and screws etc. complete : 300 x 16mm
Providing and fixing alluminium sliding tower bolt anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc. complete : 300 x 10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete: 125mm
Providing and fixing alluminium hanging floor door stopper anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete : Twin rubber stopper
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multichambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc.
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer.
Extra for providing mechanical device chain and crank operation for operating rolling shutters : Exceeding 16.80 sqm in area
Providing and fixing T-iron frames for doors. windows and ventilators of mils steel Tee-sections, joints miltred and welded with 15 x 3 mm lugs 10 cm long embedded in cement concerete blocks 15 x 10 x 10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including.
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coar of approved steel primer, welded and bolted including special shaped wahers etc. complete : Hot finished seamless type tubes
Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete.
52 mm thick cement concrete flooring with metallic concrete hardener topping under layer 40 mm thick cement concrete 1:2:4(1 cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick metallic concrete hardener consisting of mix 1:2 (1 cement hardener mix:2 stone aggregate 6 mm nominal size) by volume @ 2 liter per 50 kg of cement or as per manufacture specification. This includes cost of cement slurry,etc. but excluding the cost of nosing of steps etc. complete.
Providing and fixing glass strips in joints of terrazo/cement concrete floors: 40 mm wide and 4 mm thick
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300 x 300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing designation 100A one brick on edge soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing asbestos cement 6mm thick corrugated sheets foofing and fixing with G.I. J or, L hooks, bolts and nuts 8mm dia G.I. plain and bitumen washers complete excluding the cost of purlins, rafters and trusses corrugated sheet: Upto 60º pitch
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Shoe
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 110mm dia clip
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
12mm cement plaster of mix: 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Finishing walls with textured exterior paint of required shade : New work (Two or more coat applied @ 3.28 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm):Applying one coat of cement primer of approved brand and manufacture on wall surface: Cement primer
Applying one coat of cement primer of approved brand and manufacture on wall surface: Cement primer Distempering with oil bound washable distemper of approved brand and manufacture to give and even shade: New work (two or more coats) over and including priming coat with cement primer
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying primer coat : With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood):Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work over and under coat of suitable shade with ordinary paint of approved brand and manufacture : Applying primer coat : With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanised iron/steel works
Per bag
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level : 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)( Foundation, Band at P.L.& S.Tank Cover)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Brick work with fly ash bricks as per IS 12894 (2002) & IS 3495 in foundations and plinth in : Cement mortar 1:4(1 cement : 4 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 75mm diameter
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm dia PVC Coupler
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia PVC Coupler
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75 x 75 x 75mm dia Single Jn Tee with door
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee with door
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee without door (T. Bend)
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm Floor trap
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 75mm dia clip
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 110mm dia clip
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
12mm cement plaster of mix: 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P.brass pillar tap
Cutting holes up to 30x30 cm in walls including making good the same:With common burnt clay F.P.S. (non modular) bricks
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20x20 mm square bar
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality:LD 2.5:Rectangular shape 600x450 mm internal dimensions
Constructing brick masonry chamber for underground C.I.Inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg),R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing brick bats and filling the same in soak pit as per specificarion and direction of engineer in charge.
Per bag
DESCRIPTION
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5 mm glass shelf with edges round off,supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:32 mm dia nominal bore
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe,including painting with anti corrosive bitumastic paint,cutting chases and making good the wall :15 mm dia nominal bore
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe,including painting with anti corrosive bitumastic paint,cutting chases and making good the wall :20 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) :25 mm nominal bore:Horizontal
Providing and fixing gun metal non- return valve of approved quality (screwed end) :32 mm nominal bore:Horizontal
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete :15 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete :20 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete :25 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete :32 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms: 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:15 mm nominal bore
Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms.
Cutting holes up to 30x30 cm in walls including making good the same:With common burnt clay F.P.S. (non modular) bricks
DESCRIPTION
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:32 mm dia nominal bore
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge,upto 90 metre depth below ground level:All types of soil:300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge:100 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818,including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge:100 mm nominal size dia
Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-incharge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/casing pipe, removable as per requirement, all complete for borewell of:100 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete:100 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I): 100 mm dia
Per Set
Per Set
DESCRIPTION
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.l. box etc as required. Group B
Wiring for light/Power plug with 2x4 Sq.mm FR PVC insulated Copper conductor single core cable in surface recessed PVC conduit along with 1 No. 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. CKT- (2 x2.5mm2 + 1x2.5 mm2 earth wire)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain- (2 x6.0 mm2 + 1x6.0 mm2 earth wire)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/,switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Providing and fixing following capacity double pole/TP&N sheet metal switch disconnector fuse unit in existing metel board with rewireable type fuses, including drilling holes in metal board, making connections etc. as required. 32 Amp double pole
Providing and fixing following capacity double pole/ 4 pole OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board including drilling holes in metal metal panel, making connection etc. as required. 32 amps, double pole
Supplying and fixing following way single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface recess, complete with tinned copper bus bar, neatral busbar, earth bar dinbar detachable gland plate, interconnections, Phosphatised and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 2+6 way double door
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 6/32 amps, Single Pole
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 40 A to 63 A, SPN
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for eafth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Supplying and fixing 4'X18 wat[ LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS pVC insulate copper conductor etc. as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 30 watt
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required. 9/10 watt LED lamp
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq.mm.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 16 sq. mm, 2 core
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
DESCRIPTION
TOTAL Rs P
Legal Status of Bidder
Place of Registration
Principal Place of Business
Power of Attorney for Signatory Bid.
Satisfactory completed at least one similar work of value not less than 50% of estimated cost.
Total Requirement Value (50% of BOQ)
Actual Qnty done
Earth Work + Sand filling work
Brick Work
RCC + PCC
Stone And Tile Flooring
Aluminum Work
Intergral/ waterproofing work with A.P.P Sheet
Water Supply & Sanitation work
Electrical work
Steel Truss
Amount of Existing commitments and ongoing works in Rs with duly affidavit & issued by proper authority.(Not less than Executive Engineer)
Amount of Work for which Bid already submitted in Rupees
Building Contract Package Size **
Rs.20-50 Crores
Concrete Batching & Mixing plant Minimum capacity 15m3/hr .
Pump for concreting (Optional)
Transit Mixture
Steel shuttering
Rs. 2-10 Crores
Project Manager/ B.E. Civil + 10 Years Exp. (5 years as Manager) or retired E.E.
Site Engineer/ B.E. Civil + 07 Years Exp. (3 years in Building Construction) or retired A.E.
Plant Engineer/B.E. Mech./ Civil + 05 Years Exp. or Dip. Mech + 07 Years Exp. or Retired J.E.
Quality Engineer /B.E. Civil + 05 Years Exp. or Dip. Civil + 07 Years Exp.
Soil & Material Engineer/ B.E. Civil + 07 Years Exp.
Survey Engineer/B.E. Civil + 03 Years Exp. or Dip. Civil + 05 Years Exp.
upervisor JE /Fresh Graduate in Civil or Diploma Civil + 03 Years Exp.
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size.) ( Shelves)
Centring and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roots, landings, balcnies and access platform.
Centring and shuttering including strutting, propping etc. and removal of form for: Shelves (Cost in situ)
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Centring and shuttering including strutting, propping etc. and removal of form for: Stairs,(excluding landings) except spiral-staircaces.
Centring and shuttering including strutting, propping etc. and removal of form for: Weather shade,Chajjas, corbels etc. including edges
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 10mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 16mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 20 mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 25 mm dia.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:Add or deduct for providing richer or leaner mixes respectively at all floor levels: Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Walls columns, pillars, posts cind struts: Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.:Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) : Extra tor Brick work in superstructure above plinth level upto floor V cum
Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level. Cement mortar 1 : 3 (1 cement : 3 coarse sand)
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly. plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. but excluding carriage cost of bricks, sand and jhama metal.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite of any colour and shade:Area of slab over 0.50 sqm.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30 mm thick including stainless steel butt hinges with necessary screws.
Providing and fixing M.S. grills of requirement pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete: Fixed to steel windows by welding.
Providing and fixing alluminium sliding door bolt anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to rquired colour and shade with nuts and screws etc. complete : 300 x 16mm
Providing and fixing alluminium sliding tower bolt anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc. complete : 300 x 10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete: 125mm
Providing and fixing alluminium hanging floor door stopper anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete : Twin rubber stopper
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multichambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc.
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multichambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc.
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer.
Providing and fixing pressed steel door confirming IS code 351 manufactured from commercial mild steel sheet of 1.25 mm thickness including higes, jamb, lock jamb , bead and if required angle threshold of mild steel angle of section 50 x 25 mm or base ties of 1.25 mm pressed mild steel welded or rigidly fixed together by mechinical means, adjustable lugs with split end tail to each jam including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge. Profile B, Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete.
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel, etc as required: In gratings, frames, guard bar, ladders, railing, brackets, gets & similar works.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
Chequered terrazo tiles 22 mm thick with marble chips of sozes upto 6 mm in floors jointed with neat cement slurry mixed with pigement to match the shade of the tiles, including rubbing and polshing complete on 20 nm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) : Medium shade using 50% white cement and 50% ordinary cement.
Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with: Makrana white second quality.
Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with: Black Zebra marble.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300 x 300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying vitrifed floor tiles in different sizes { thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete: Size of Tile 60 x 60 cm.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete : Size of Tile 600 x 600 mm.
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Shoe
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 110mm dia clip
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diametre and weighing not less than 440 grams.
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
12mm cement plaster of mix: 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying primer coat : With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanised iron/steel works:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm, modulus of elasticity 900 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for Separately).
Providing and fixing factory made single extruded WPC {Wood Polymer Composite} solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibers {wood powder/ rice husk/wheat husk) and non toxic additives {maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800N {Face) & 900N (Edge), minimum compressive strength 50 N/mm, modulus of elasticity 850 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In• Charge. {Note:stainless steel butt hinges and necessary S.S screws shall be paid separately) 35 mm thick
Supplying fitting and fixing 24 gauge thick Aluminum sheet of approved quality over wooden surface of door shutters including cost of nails its all complete job as per building specification and direction of E/I.
Per bag
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level : 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)( Foundation, Band at P.L.& S.Tank Cover)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Brick work with fly ash bricks as per IS 12894 (2002) & IS 3495 in foundations and plinth in : Cement mortar 1:4(1 cement : 4 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 75mm diameter
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75 x 75 x 75mm dia Single Jn Tee with door
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee with door
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee without door (T. Bend)
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm dia Plain bend : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diametre and weighing not less than 440 grams.
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 75mm dia clip
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 110mm dia clip
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
12mm cement plaster of mix: 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS :7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P.brass pillar tap
Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete,including painting the fittings and brackets, cutting and making good the walls wherever required : White glazed fire clay kitchen sink of size 600x450x250 mm
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 coarse sand 6 graded stone aggregate 20 mm nominal size) including disposal of malba.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20x20 mm square bar
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality:LD 2.5:Rectangular shape 600x450 mm internal dimensions
Constructing brick masonry chamber for underground C.I.Inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg),R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing brick bats and filling the same in soak pit as per specificarion and direction of engineer in charge.
Per bag
DESCRIPTION
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5 mm glass shelf with edges round off,supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Concealed work, including cutting chases and making good the : 15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge:Concealed work, including cutting chases and making good the : 20 mm nominal outer dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:32 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:32 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) :32 mm nominal bore:Horizontal
Providing and fixing gun metal non- return valve of approved quality (screwed end) :32 mm nominal bore:Vertical
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete :20 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete :25 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete :32 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms: 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:15 mm nominal bore
Providing and fixing PTMT swivelling shower, 15 mm nominal bore,
Cutting holes up to 30x30 cm in walls including making good the same:With common burnt clay F.P.S. (non modular) bricks
DESCRIPTION
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:32 mm dia nominal bore
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge,upto 90 metre depth below ground level:All types of soil:300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge:100 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818,including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge:100 mm nominal size dia
Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-incharge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/casing pipe, removable as per requirement, all complete for borewell of:100 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete:100 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I): 100 mm dia
Per Set
Per Set
DESCRIPTION
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.l. box etc as required. Group B
Wiring for light/Power plug with 2x4 Sq.mm FR PVC insulated Copper conductor single core cable in surface recessed PVC conduit along with 1 No. 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. CKT- (2 x2.5mm2 + 1x2.5 mm2 earth wire)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain (4x6.0 mm2 + 1x6.0mm2)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain (4x16 mm2 + 1x16 mm2)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/,switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 2 Pin, 6 amps ceilling rose on the existing Junction box / wooden block including connection etc. as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required' lOO A, 30 KA, FPMCCB
Providing and fixing following rating & breaking capacity MCCB in existing cubicle panel board, including drilling holes in cubicle panel, making connections, etc. as required. 250 A, 50 KA, FPMCCB
Providing and fixing following capacity busbar Chamber with 4 strips of suitable size made of copper, heavy duty complete with all accessories including connections, earthing the body etc. as required. 100 Amps.
Providing and fixing following capacity busbar Chamber with 4 strips of suitable size made of copper, heavy duty complete with all accessories including connections, earthing the body etc. as required. 400 Amps.
Providing and fixing following capacity 4 pole ON-load/panel mounted changeover switches inside the existing cubicle panel board including drilling holes in cubicle panel making connections etc. as required. 200 amps, four pole
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required, (But without MCB/RCCB/lsolator) 4 way ( 4 + 12 ), Double door, horizontal type
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 6 A to 32'A, Single pole
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 40 A to 63 A,.TP
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 40 A to 63 A, TP&N
Providing and fixing M.V. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for eafth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Supplying and fixing 4'X18 wat[ LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS pVC insulate copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 Im/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required. 18 watt
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 90 watt
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required. 9/10 watt LED lamp
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 95 sq.mm and upto 185 sq.mm.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 120 sq. mm, 3.5 core
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep
20 mm X 3 mm copper tape ( 0.533 kg/mtr)
Providing and fixing following capacity busbar Chamber with 4 strips of suitable size made of copper, heavy duty complete with all accessories including connections, earthing the body etc. as required. 63A
2.5 sq. mm lSl marked, FRLS PVC insulated single core copper conductor cable
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for eafth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Providing and fixing of lightning conductor final made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes tec. Complete as required.
Providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as required. (For Horizontal run)
Providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as required. (For vertical run)
DESCRIPTION
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. CKT- (2 x2.5mm2 + 1x2.5 mm2 earth wire)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. CKT- (2 x4.0mm2 + 1x4.0 mm2)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain- (2 x6.0 mm2 + 1x6.0 mm2 earth wire)
Supplying and fixing suitable size metal./pvc. box of 150 mm x 75 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connections, painting etc. as required.
Supplying and fixing suitable size metal./pvc. box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connections, painting etc. as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed PVC conduit as required. 1 run of cable
Providing and fixing following capacity double pole/ four pole OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board, including drilling holes in metal panel, making connections etc. as required. 63 A, double pole
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCBilsolator) 5 way, Double door
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 6 A to 32'A, Single pole
Supplying and fixing following rating double pole, 240 voltas Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for eafth electrode to fill up the excavated earth and earth inspection pit etc. as required.
DESCRIPTION
Supplying and drawing following size of FR PVC insulated copper conductor, single core cable in the existing surface/recessed PVC conduit as requirjed: 2 x 1.5 sq.mm
Providing and fixing following capacity double pole/TP&N sheet metal switch disconnector fuse unit in existing metel board with rewireable type fuses, including drilling holes in metal board, making connections etc. as required. 32 Amp double pole
Earthing with GI earth pipe 4.5 meter long and 40 mm dia including accessories, and providing masonary enclosures with cover plate having locking arrangment and watering pipe etc.with charcoal and salt as required .
Providing and laying earth connection from earth electrode with 6 SWG dia G.I.wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and refilling etc. as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 90 watt
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq.mm.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 6 sq. mm, 4 core
Supply and erection of 7 metre height Hot-dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia A/F 155 mm, made of 3 mm thick sheet along with base plate of size 260 X 260 X 16 mm , small door opening for junction box mounting including 64 'C' series SP MCB, conneclor, and suitable size foundation bolts with template as required.(but without pole foundation)
Providing, laying and fixing of following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required 50 mm dia
DESCRIPTION
Supplying and fixing fotrlowing types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on poleibuilding including connection earthing the body etc as required.200 watt
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq.mm.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 25 sq. mm, 3.5 core
Supply of 16/20 mtr High Mast lighting system with accessories as per design and drawing foundation bolt, aviation light and automatic on/off control panel etc all complete (Reputed Co and ISI/Iso)
Erection and commissioning with High Mast with suitable equipment, design and casting of shallow foundation with M20 concrete for High Mast I.E earthing etc as required.
Making good the above PCC of above trench with required materials cement sand graded stone (1:3:6)
DESCRIPTION
DESCRIPTION
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
Centring and shuttering including strutting, propping etc.and removal or form work for Foundations,footings, bases Columns
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing designation 100A one brick on edge soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Per bag
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level : 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement. 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form for: foudations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 10mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) : Extra tor Brick work in superstructure above plinth level upto floor V cum
Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level. Cement mortar 1 : 3 (1 cement : 3 coarse sand)
Welding by electric plant incluidng transportation of electric welding plant at site etc. complete.
Drilling 6mm dia in M.S.angle iron for fixing of staples etc.as per building specification and direction of E/I.
Labour for cutting M.S.angle iron post to required length, one and splitted as fish tailed in a length of 150mm complete as per building specification and direction of E/I.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Applying primer coat : With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanised iron/steel works:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Supplying M.S. Angle as per IS: 226 size 50 x 50x 6mm
Per bag
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level : 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upt floor five level excluding cost of centring, shuttering, finishin and reinforcement. 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form for: foudations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 16mm dia.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Applying primer coat : With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanised iron/steel works:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Per bag
DESCRIPTION
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
DESCRIPTION
Plantation work (10 gram DAP and pesticide per plant). Transportation of plant and planting work from temporary plant salad. Plantation 20 man days, Transportation of Plant- 6 man days, DAP-260/- persicide 100 Rs. Etc-50/-
Provision for plant transportion by tractor.
Providing bomboo barricating
Purchase of earth and round 152.5 [email protected]/cft per% no plants.
Labour for planting.
(A) Suppling and providing plants all as following details (10 plant's)
(B) Suppling and providing plants all as following details (10 plant's)
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roots, landings, balcnies and access platform.
Centring and shuttering including strutting, propping etc. and removal of form for: Shelves (Cost in situ)
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Centring and shuttering including strutting, propping etc. and removal of form for: Weather shade,Chajjas, corbels etc. including edges
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 10mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 16mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 20 mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 25 mm dia.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:Add or deduct for providing richer or leaner mixes respectively at all floor levels: Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Walls columns, pillars, posts cind struts: Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.:Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) : Extra tor Brick work in superstructure above plinth level upto floor V cum
Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level. Cement mortar 1 : 3 (1 cement : 3 coarse sand)
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly. plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. but excluding carriage cost of bricks, sand and jhama metal.
Providing and fixing flush door shutters conforming to IS : 2202 (Part-I) non-decorative type.core of block board construction with frame of 1st class tiard wood and well mathched commercial 3 ply veneering wiih vertical grains or cross bands and face veneers on both faces of shutters : 30 mm thick including anodized aluminum butt hinges with necessary screws.
Providing and fixing M.S. grills of requirement pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete: Fixed to steel windows by welding.
Providing and fixing alluminium sliding door bolt anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to rquired colour and shade with nuts and screws etc. complete : 300 x 16mm
Providing and fixing alluminium sliding tower bolt anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc. complete : 300 x 10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete: 125mm
Providing and fixing alluminium hanging floor door stopper anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete : Twin rubber stopper
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multichambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc.
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer.
Extra for providing mechanical device chain and crank operation for operating rolling shutters : Exceeding 16.80 sqm in area
Providing and fixing T-iron frames for doors. windows and ventilators of mils steel Tee-sections, joints miltred and welded with 15 x 3 mm lugs 10 cm long embedded in cement concerete blocks 15 x 10 x 10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including.
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coar of approved steel primer, welded and bolted including special shaped wahers etc. complete : Hot finished seamless type tubes
Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete.
52 mm thick cement concrete flooring with metallic concrete hardener topping under layer 40 mm thick cement concrete 1:2:4(1 cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick metallic concrete hardener consisting of mix 1:2 (1 cement hardener mix:2 stone aggregate 6 mm nominal size) by volume @ 2 liter per 50 kg of cement or as per manufacture specification. This includes cost of cement slurry,etc. but excluding the cost of nosing of steps etc. complete.
Providing and fixing glass strips in joints of terrazo/cement concrete floors: 40 mm wide and 4 mm thick
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300 x 300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing designation 100A one brick on edge soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing asbestos cement 6mm thick corrugated sheets foofing and fixing with G.I. J or, L hooks, bolts and nuts 8mm dia G.I. plain and bitumen washers complete excluding the cost of purlins, rafters and trusses corrugated sheet: Upto 60º pitch
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Shoe
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 110mm dia clip
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
12mm cement plaster of mix: 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Finishing walls with textured exterior paint of required shade : New work (Two or more coat applied @ 3.28 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm):Applying one coat of cement primer of approved brand and manufacture on wall surface: Cement primer
Applying one coat of cement primer of approved brand and manufacture on wall surface: Cement primer Distempering with oil bound washable distemper of approved brand and manufacture to give and even shade: New work (two or more coats) over and including priming coat with cement primer
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying primer coat : With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood):Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work over and under coat of suitable shade with ordinary paint of approved brand and manufacture : Applying primer coat : With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanised iron/steel works
Per bag
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level : 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)( Foundation, Band at P.L.& S.Tank Cover)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Brick work with fly ash bricks as per IS 12894 (2002) & IS 3495 in foundations and plinth in : Cement mortar 1:4(1 cement : 4 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 75mm diameter
Providing and fixing on wall face unplasticised-PVC (working pressure 4 kgf per sqcm) rain water pipes conforming to IS : 4985 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 110mm diameter
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm dia PVC Coupler
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia PVC Coupler
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75 x 75 x 75mm dia Single Jn Tee with door
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee with door
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110 x 110 x 110mm dia Single Jn Tee without door (T. Bend)
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm dia Plain bend
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 75mm Floor trap
Providing & fixing on wall face unplastisised P.V.C. pipe (working pressure 4 Kg/Sq.cm) confirming to IS-4985 for severage inlcuding jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expanssion: 110mm dia Plain bend
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 75mm dia clip
Providing and fixing unplasticised-PVC clip of approved design to unplasticised PVC by means of 50 x 50 x 50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar (1:4) 1 cement : 4 coarse sand and making good the wall etc. complete: 110mm dia clip
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
12mm cement plaster of mix: 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P.brass pillar tap
Cutting holes up to 30x30 cm in walls including making good the same:With common burnt clay F.P.S. (non modular) bricks
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20x20 mm square bar
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality:LD 2.5:Rectangular shape 600x450 mm internal dimensions
Constructing brick masonry chamber for underground C.I.Inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg),R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing brick bats and filling the same in soak pit as per specificarion and direction of engineer in charge.
Per bag
DESCRIPTION
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5 mm glass shelf with edges round off,supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc:Internal work - Exposed on wall:32 mm dia nominal bore
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe,including painting with anti corrosive bitumastic paint,cutting chases and making good the wall :15 mm dia nominal bore
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe,including painting with anti corrosive bitumastic paint,cutting chases and making good the wall :20 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) :25 mm nominal bore:Horizontal
Providing and fixing gun metal non- return valve of approved quality (screwed end) :32 mm nominal bore:Horizontal
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete :15 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete :20 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete :25 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete :32 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms: 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:15 mm nominal bore
Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms.
Cutting holes up to 30x30 cm in walls including making good the same:With common burnt clay F.P.S. (non modular) bricks
DESCRIPTION
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc:External work:32 mm dia nominal bore
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge,upto 90 metre depth below ground level:All types of soil:300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge:100 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818,including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge:100 mm nominal size dia
Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-incharge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/casing pipe, removable as per requirement, all complete for borewell of:100 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete:100 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I): 100 mm dia
Per Set
Per Set
DESCRIPTION
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.l. box etc as required. Group B
Wiring for light/Power plug with 2x4 Sq.mm FR PVC insulated Copper conductor single core cable in surface recessed PVC conduit along with 1 No. 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. CKT- (2 x2.5mm2 + 1x2.5 mm2 earth wire)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain- (2 x6.0 mm2 + 1x6.0 mm2 earth wire)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/,switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Providing and fixing following capacity double pole/TP&N sheet metal switch disconnector fuse unit in existing metel board with rewireable type fuses, including drilling holes in metal board, making connections etc. as required. 32 Amp double pole
Providing and fixing following capacity double pole/ 4 pole OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board including drilling holes in metal metal panel, making connection etc. as required. 32 amps, double pole
Supplying and fixing following way single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface recess, complete with tinned copper bus bar, neatral busbar, earth bar dinbar detachable gland plate, interconnections, Phosphatised and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 2+6 way double door
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 6/32 amps, Single Pole
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 40 A to 63 A, SPN
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for eafth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Supplying and fixing 4'X18 wat[ LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS pVC insulate copper conductor etc. as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 30 watt
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required. 9/10 watt LED lamp
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq.mm.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 16 sq. mm, 2 core
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
DESCRIPTION
TOTAL Rs P
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
e NIT 07 SBD 2026-27.pdf
NIT • 2.22 MB
GR-05 BOQ-07 2026-27.xls
NIT • 0.24 MB
GR-05 SBD-07 2026-27.docx
NIT • 0.51 MB
GR-05 TECH-07 2026-27.xls
NIT • 0.05 MB
GR-05 BOQ-07 2026-27.xls
NIT • 0.24 MB
Download all tender documents and submit your bid