| 1 | L1₹28.2 LAccepted-AOC SUSHAMAPALLY PO NIMPURA KHARAGPUR DIST PASCHIM MEDINIPUR PIN 721304 W B | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.7 L+₹1.1 L (3.73%)Rejected-Finance 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹31.8 L+₹3.2 L (11.2%)Rejected-Finance VILL GAIDUA PO HARIATARA P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPORE ST WEST BENGAL PIN 721 304 | MEDINIPUR WEST | WEST BENGAL | 721304 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹32.4 L+₹3.8 L (13.4%)Rejected-Finance VILL SAROT PALLY PO SANKRAIL DIST HOWRAH PIN 711313 WB | SANKRAIL | HOWRAH | WEST BENGAL | 711313 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹32.6 L+₹4.0 L (14.1%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
20 Nov 2020, 6:00 pmClosed
GE (AF) Kalaikunda
GE (AF) Kalaikunda
DAY TO DAY MAINT OF E/M SERVICES AND REPLACEMENT OF ELECTRICAL FITTINGS, REWIRING AND ALLIED WORKS AT AF STN KALAIKUNDA
2020_MES_369226_3
8591/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Kalaikunda
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (AF) Kalaikunda
₹50,000
Yes
22 Mar 2021
13 Nov 2020
23 Nov 2020
13 Nov 2020
20 Nov 2020
14 Nov 2020
13 Nov 2020 - 14 Nov 2020
Amount
S&F in repair switch piano flush type single pole one way 5 Amps including taking out u/s : Make : Anchor / L& T/ Havells
S&F switch piano flush type single pole one way 5 Amps : Make : Anchor / L& T/ Havells (Note : Item to be measured if executed under new point wiring)
S&F in repair Switch socket combination 2 in 1, flush type 5/6 Amps including taking out u/s : Make : Anchor / L& T/ Havells
S&F Switch socket combination 2 in 1, flush type 5/6 Amps : Make : Anchor / L& T/ Havells (Note : Item to be measured if executed under new point wiring)
S&F in repair switch socket combined outlet 6 pin flush type 15 Amp multi purpose including taking out u/s : Make : Anchor / L& T/ Havells
S&F Switch socket combined outlet 6 pin flush type 15 Amp multi purpose : Make : Anchor / L& T/ Havells (Note : Item to be measured if executed under new point wiring)
S&F in repair ceiling rose surface bakelite 65 mm dia three terminal complete including taking out u/s : Make Anchor Penta / L& T
S&F ceiling rose surface bakelite 65 mm dia three terminal complete. : Make Anchor Penta / L& T (Note : Item to be measured if execuated under new point wiring)
S&F in repair bell push flush type SP 5 Amp including taking out u/s : Make : Anchor / L& T/ Havells
S&F bell push flush type SP 5 Amp : Make : Anchor / L& T/ Havells (Note : Item to be measured if executed under new point wiring)
S&F in repair Buzzer electric single phase suitable for 220 Volt complete including taking out u/s : Make : Anchor / L& T/ Havells
S&F in repair bell ding dong type,AC, 230 volts, single pole fixed in repair complete including taking out u/s : Make : Anchor / L& T/ Havells
S&F bell ding dong type,AC, 230 volts, single pole on PVC box : Make : Anchor / L& T/ Havells (Note : Item to be measured if executed under new point wiring)
Supply and fixing in repair lamp holder , PVC/Poly carbonate type with back plate suitable for batten fittings to be fixed on PVC box including supply and fixing 10 watt LED lamp and taking out u/s. Make For holder : Anchor / L& T/ Havells. LED lamp : Philips/ Bajaj/ Crompton/ Havells
Supply and fixing lamp holder , PVC/Poly carbonate type with back plate suitable for batten fittings to be fixed on PVC box including supply and fixing 10 watt LED lamp. Make For holder : Anchor / L& T/ Havells. LED lamp : Philips/ Bajaj/ Crompton/ Surya (Note : Item to be measured if executed under new point wiring)
S&FLED 18 Watt tube light fitting (T8 type) ,single end connection type including LED retrofit tube lamp 18 W , 240 Volt, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed including taking down old unserviceable. Make :- Bajaj (Batten Cat No. BLRB DB 118 box type batten suitable for 18/20 watt retofit LED tube single side connection type). LED lamp : Make : Bajaj Cat No. BLRB 18W CW LED (retrofit LED tube lamp 18 Watt, Single end connection) or equivelent in Crompton / Havells as approved by GE. Note : Make of batten and LED tube lamp should be of same make. (Note : Item to be measured if executed under new point wiring)
Taking down old unserviceable TPN / SPN MCB DB's incl MCB of any size and any discription all as directed by Engr-In-Charge.
S & F sheet metal enclosure for MCB, DB, VTPN 415 Volts,IP-43, 100 amps rated copper busbar 4 way Double door ( Vertical DB with MCB as incomer) Confirming to IS as per IEC 61439-3 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-charge. Make Legrand/ Seimens/ Schinder
S&F sheet metal enclosure for VT DB TPN, MCB DB TPN 4 way (with provision for MCCB as INCOMER and MCB as out going), Confirming to IS as per IEC 61439-3, IP 43,double door including 63 Amp, 25 kA,TP MCCB as incomer (Vertical type double door, 63 Amps MCCB rate inclusive) including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-charge. Make Legrand/ Seimens/ Schneider.
S & F sheet metal enclosure MCB, DB, SPN, 240 Volts, 100 Amps rated copper busbar, Confirming to IS as per IEC 61439-3, 12 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.Make- Legrand/ Seimens/ Schinder.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.Make- Legrand/ Seimens/ Schinder.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.Make- Legrand/ Seimens/ Schinder.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 2 way, single door without bus bar, enclosure made up of CRCA sheet steel RAL 9003 powder coated, IP 30 complete all as specified and directed by Engr-in-charge.Make- Legrand/ Seimens/ Schinder.
S&F in repair MCB FP 50 to 63 Amps, 10 KA 'C' Curve breaking capacity, including connection with suitable size copper lugs including taking down u/s complete all as specified and directed by Engr-In-Charge.
S&F in repair MCB TP 40 to 63 Amps, 10 KA 'C' Curve breaking capacity, including connection with suitable size copper lugs including taking down u/s complete all as specified and directed by Engr-In-Charge.
S&F in repair MCB FP 100 Amps, 16 KA 'C' Curve breaking capacity, including connection with suitable size copper lugs including taking down u/s complete all as specified and directed by Engr-In-Charge..
S&F in repair MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs including taking down u/s complete all as specified and directed by Engr-In-Charge .
S&F in repair MCB SPN 6 to 32 amps 10 KA , 'C' Curve including connection with suitable size copper lugs including taking down u/s complete all as specified and directed by Engr-In-Charge Make- Legrand/ Seimens/ Schinder.
Supply and fixing in repair of stepped type electronic fan regulator 100 watt flush type (delux) on the existing hylem laminated sheet etc as required. Make: Anchor (Delux) / L&T/ Havells
Supply and fixing of stepped type electronic fan regulator 100 watt flush type (delux) on the existing phenolic laminated sheet etc as required. Make: Anchor (Delux) / L&T/ Havells (Note : Item to be measured if executed under new point wiring)
S&F in repair LED 18 Watt tube light fitting (T8 type) ,single end connection type including LED retrofit tube lamp 18 W , 240 Volt, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed including taking down old unserviceable. Make :- Bajaj (Batten Cat No. BLRB DB 118 box type batten suitable for 18/20 watt retofit LED tube single side connection type). LED lamp : Make : Bajaj Cat No. BLRB 18W CW LED (retrofit LED tube lamp 18 Watt, Single end connection) or equivalent in Crompton /Philips/ Havells as approved by GE. Note : Make of batten and LED tube lamp should be of same make.
S&F in repair LED tube lamp 18 Watt (reterofit type, T8 pattern, single side connection) 240 V, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, to be fixed in existing or new batten/ patti including changing the wiring suitable for T8 LED retrofit lamp in existing tube light fitting complete. Make :- Bajaj Cat No. BLRB 18W CW LED or equivalent in Philips/CG/Wipro as approved by GE.
S&F in repair LED 9/10 Watt tube light fitting intergated type, 240 v, PF > 0.90, colour Temp 6500 K, suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :- Bajaj/ Crompton/Wipro/Philips as approved by GE.
S&F in repair LED lamp 18 Watt 4 Pin type, colour Temp 6500K, retrofit type in existing fitting with necessary change in wiring complete all as specified and directed by Engineer in charge. Make : Bajaj/ Crompton/Philips/Wipro as approved by GE.
S&F in repair LED light with pressure die-cast housing along with prismatic polycarbonate diffuser and LED's with secondary optics and IP-65 protection of 25 watt,PF>0.9 for building security light complete all as specified and directed by Engineer in charge. Make : Bajaj Cat Part No. BCLST25 W LED IV2 or equivalent in Crompton/Wipro as approved by GE.
S&F in repair LED bulkhead light of 10W with pressure die-cast housing along with polycarbonate diffuser and LED's IP-65 protction of watt,PF>0.95 complete all as specified and directed by Engineer in charge. Make : Bajaj/ Crompton/Philips/Wipro as approved by GE.
Taking down old unserviceable sub main wiring of any size and any description all as directed by Engr-In-Charge.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor, FRLS cable drawn in but including non metallic rigid PVC conduit of 25 mm dia ISI marked including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete. Make: L&T / Polycab/ C&S/Anchor
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4.0 Sqmm size with multistranded copper conductor FRLS cable (with colour code), drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC, including PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete. Make of wire : L&T / Polycab/ Havells
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLS cable drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continous earth conductor cable connected to earth dolly complete. Make of wire : L&T / Polycab/ Havells
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 10.0 Sqmm (with colour code), drawn in but including PVC casing caping not less than 25 mm width ISI marked double locking type including one including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed by EIC. Make of wire : Polycab/ Havells/L&T
M&L for Sub main wiring with Four single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor, FRLS cable drawn in but including PVC casing capping not less than 32 mm ISI marked including all accessories of casing caping as approved by EIC including two run of PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete ( 4 x 6.0 sqmm + 2 x 6.0 Sqmm earth wire) . Make of wire : L&T / Polycab/ Havells
M&L for Sub main wiring with Four single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 10 Sqmm size with multistranded copper conductor, FRLS cable drawn in but including PVC casing capping not less than 40 mm ISI marked including all accessories of casing caping as approved by EIC including two run of PVC insulated unsheathed 10.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete ( 4 x 10.0 sqmm + 2 x 10.0 Sqmm earth wire) . Make of wire : L&T / Polycab/ Havells
M&L for repairing distribution box(DB's) of any rating, any size by proper dressing of wirings,providing lugs, screw, nuts , cleaning of the burned surfaces etc, tightening of all the connections of incoming and outgoings from the MCB's/ DB, connecting Earthing connection to each earth dolly including fixing of DB cover by providing screws etc complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC casing caping of min 25 mm dia exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition by proper relaying of existing PVC cables including removing of cables/ wires and relaying after fixing of new casing capping including taking down old u/s all as specified and directed by Engineer in charge.
S&F in repair PVC casing caping (RACEWAY) of single compartment having size 50 mm x 38 mm, standard length 2 meters exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition including removing of cables/wires and relaying after fixing of new casing capping including taking down old u/s all as specified and directed by Engineer in charge.
S&F in repair PVC casing caping (RACEWAY) of two compartments having size 100 mm x 38 mm, standard length 2 meters exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition including removing of cables/wires and relaying after fixing of new casing capping including taking down old u/s all as specified and directed by Engineer in charge.
Supply and fixing in repair PVC insulated multistranded Copper conductor, sheathed round cable ISI marked 2.5 sqmm x 3 core complete all as specified and directed by Engr-in-charge. Make : Finolex/ Havells
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants,regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc.complete all as specified and directed by Engr-in-charge.
M & L point wiring for ) One light/fan/ call bell point controlled by one switch, with 1.5 Sqmm multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLS cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, including sunken in cast iron/MS/GI terminal box duly painted with aluminium paint inside and anticorrosive paint out side with 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets, complete all as specified and as directed Note : (i) Contractor has to make the surface good after flushing the sunken box as existing without any extra cost (ii) Length or wiring 10 mtrs from switch board to be considered as one point wiring. (iii) Rate of circuit wiring from DB to switch board is included in unit rate of item.
All as per item No 50 here-in-before above but One 3 pin socket outlet 5 Amps on independent board, complete all as specified and as directed
All as per Item No. 50 here-in-before but with FRLS grade, (ISI mark) PVC insulated and unsheathed two run multistranded copper conductor of size 2.5 Sqmm for one power point of 3 pin 15 Amps on independent board including FRLS grade (ISI mark), PVC insulated, unsheathed one run multi-stranded copper conductor of size 2.5 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed.
All as per Item No. 50 here-in-before but with FRLS grade, (ISI mark) PVC insulated and unsheathed two run multistranded copper conductor of size 4.0 Sqmm for one power point of 3 pin 15 Amps on independent board including FRLS grade (ISI mark), PVC insulated, unsheathed one run multi-stranded copper conductor of size 4.0 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed.
Supply and replacement of 3 pin plug top AC-230 v 15 Amp, complete all as specified and as directed. Make : Anchor/ L&T/Havells
Taking down of Gyser of any capacity any type from exiting position for descaling, removing its accessories removing the scale (white presipated) deposited in it, cleaning the inner tank properly and re-assembling the same and refixing to its existing location with testing for its proper functioning complete all as specified and directed by Engr-in-charge.
Supply and fixing the Thermostat ISI marked as per exiting size of spares of geyser in repair and testing after replacing the defective part for proper functioning of gyser all as specified and directed by EIC. Make : Danfoss / Ranco / Indfoss
All as per item No 56 here-in-before but Heating element 1.5 KW, ISI marked as per existing of spares of gysers, complete all as specified and as directed. Make : Bajaj / Usha/Theta
All as per item No 56 here-in-before but Heating element 2.0 KW, ISI marked as per existing of spares of gysers, complete all as specified and as directed. Make : Bajaj / Usha/Theta
All as per item No 56 here-in-before but Indicator lamp with flexibe copper wire of suitable size Red/Green of spares of gysers, complete all as specified and as directed.
S&F in repairs PVC Connection with steel reinforced pipe for hot water connection of Size 18" x 1/2" including rubber washers, complete all as specified and as directed.
S&F in repairs Copper Apperture plate suitable for 25/50 ltrs geyser along with rubber gasket, nuts, bolts,etc, complete all as specified and as directed.
S&F in repairs Heating element 1.5 KW, ISI marked ,model as per existing type Make : Bajaj / Usha/Theta/ Haveels/ Crompton. (Note heating element replaced other than in item No. 55 is measured under this item).
S&F in repairs Heating element 2.0 KW, ISI marked, model as per existing type Make : Bajaj / Usha/Theta/ Havells/ Crompton. (Note heating element replaced other than in item No. 55 is measured under this item.
M&L for complete servicing of solar hot water system (solar water heater, flate plate collector type), with cleaning of sluge deposited in pipe line of solar pannel by using cleaning regent, check and repair of pipe line for any leakage, including carring out brazing of copper pipe for leakage, cleaning of glass shell, cleaning of hot water tank, replacement of u/s clamps, adopter, hose pipe including filling of distilled water and coolent in reservior including complete sevicing to keep the plant functional of capacity up to 200 LPD, complete all as specified and as directed.
S&F in repairs for replacement of thermostate, long body, ISI marked of solar water heater of cap up to 200 LPD, complete all as specified and as directed.
S&F in repairs for replacement of electrical heating element of 2.0 KW (long thread type, as per existing), ISI marked, of solar water heater of cap up to 200 LPD, complete all as specified and as directed. Make: Solar Element or equivelent as approved by GE.
M&L for replacement in repair hot water pipe insulation with glass wool and aluminium cladding 20 mm bore including all material as required and directed by EIC.
S&F in repair single phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V, 5-30 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing Polycarbonate box cover, including making complete electric connections all as directed specifed and directed by EIC Make : Secure (Model Saral) or eqivelent in L&T Note : Old meter to be deposite in AGE E/M store and Receipt Voucher submited alongwith Final Bill.
S&F in repair three phase, 4 wire direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V( P-N) and 400/415V (P-P), 20-100 Amp, sprint 350, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing Polycarbonate box cover, including making complete electrical connections, connecting PVC cable by providing suitable size copper lugs etc, all as directed specifed and directed by EIC Make : Secure (Model Sprint 350) or eqivelent in L&T Note : Old meter to be deposite in AGE E/M store and Receipt Voucher submited alongwith Final Bill.
S & F single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, including taking down old u/s one complete all as specified and as directed. Make : Legrand cat part No. 607841 or equivelent in Schinder/ L&T.
S&F in repairs laminated hylam sheet cover size 11 x 13 inches, ISI marked with CM/L no., cut with grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing in loc with new galvanised screw and cup washer complete all as specified and directed by EIC.
All as per Item No. 71 here-in-before but laminated hylam sheet cover sizes (9 x 11) inches, complete all as specified and as directed.
All as per Item No. 71 here-in-before but laminated hylam sheet cover of sizes (5 x 8) inches, complete all as specified and as directed.
All as per Item No. 71 here-in-before but laminated hylam sheet cover of sizes (5 x 5) inches, complete all as specified and as directed.
S&F Hylam sheet ISI marked min 2.8 mm sheet of suitable size as per site requirement to cover the DB box including cut with grooves for operation of MCB including fixing of sheet with providing steel /brass screw and cup washers as required at site complete as directed by Engineer in Charge.
Taking down old ceiling fan/Exhaust fans/Wall mounting fan of any cap/sweep after disconnecting the electric supply from any site, checking for its electrical defect and opening fans for checking of mechanical defect after dismentlling of fan, carried out repair/over hauling including removing dust and grease, and cleaning of internal mechanical parts of fan with kerosene oil, checking of alignment of shaft, oiling and greasing, checking of worn out bearing and other defective parts, winding, condenser etc and re-assembling, and connecting/refixing of fans in its original position by providing new GI nut bolt, lock washer and lock/split pin complete all as specified and directed by Engr-in-charge. NOTE: (i) Rewinding and replacement of defective parts etc shall be measured and paid seperately
Supply only Bearing No 6201 for fixing against defective parts of fan taking down under item No 75 here in before complete all as specified and directed by Engr-in-charge. Make : SKF/NBC/FAG
Supply only Bearing No 6202 for fixing against defective parts of fan taking down under item No 75 here in before complete all as specified and directed by Engr-in-charge. Make : SKF/NBC/FAG
Supply only Bearing No 6203 for fixing against defective parts of fan taking down under item No 75 here in before complete all as specified and directed by Engr-in-charge. Make : SKF/NBC/FAG
Supply only Bearing No 6204 for fixing against defective parts of fan taking down under item No 75 here in before complete all as specified and directed by Engr-in-charge. Make : SKF/NBC/FAG
Supply only condenser 2.5 mfd for fixing against defective parts of fan taking down under item No 75 here in before complete all as specified and directed by Engr-in-charge. Epcos/Tibcon/ Havells
Supply only condenser 4.0 mfd for fixing against defective parts of fan taking down under item No 75 here in before complete all as specified and directed by Engr-in-charge. Epcos/Tibcon/ Havells
M&L for Rewinding of ceiling fan of sweep 1200 mm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed by Engr-in-charge.
M&L for Rewinding of ceiling fan of sweep 1400 mm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed by Engr-in-charge.
M&L for Rewinding of Exhaust fan of 280/300 mm any make any model , 1400 rpm with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed by Engr-in-charge.
M&L for Rewinding of Wall mounting fan of 300 to 400 mm sweep any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed by Engr-in-charge.
Taking down existing u/s CFL light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , white powder coated CRCA housing with LEDs, seam less front frame with flat white high transmission acrlyic cover, classic design with glare free soft illumination, cool white,including making electric connection from source with PVC sheathed copper conductor wire complete all as specified and directed by Ein C. .Make : Bajaj Cat Part No. BZRSQL 36W GZi CW or equivalent in Philips/ Havells
S&F in repair modular switch piano 1 way 6A, 1 Module including taking out u/s : Make : Anchor / L& T/ Havells
S&F in repair modular switch piano 1 way 16A, 1 Module including taking out u/s : Make : Anchor / L& T/ Havells
S&F in repair modular bell switch 1 way , 1 Module including taking out u/s : Make : Anchor / L& T/ Havells
S&F in repair modular socket 6A/16A 2/3 Pin combined -2 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings including taking out u/s all as specified and directed by Engr- in - Charge : Make : Anchor / L& T/ Havells
S&F in repair modular switch socket combination 16A , 6 Pin combined -3 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings including taking out u/s all as specified and directed by Engr- in - Charge : Make : Anchor / L& T/ Havells
Supply and fixing in repair of stepped type Modular electronic fan regulator 2 module , 100 watt flush type , (deluxe) on the existing hylam laminated sheet etc as required. Make: Anchor (Deluxe /Code:-14502) / L&T/ Havells
S&F in repairs PVC insulated, Single core, unsheathed, HRFR copper conductor flexible cable, 1100 Volt, Conf to IS 694, ISI marked of size 16 Sqmm including copper lugs, brass nut and bolt with washer of suitable size as per site requirement to connect the cable including taking down u/s complete all as specified and directed by Engineer in Charge. Make : Havells / Polycab/ Finolex. General Notes :(i) For item to be replaced under repair (day to day complaint) contactors trade man should report to E/M complaint cell daily and take complaint from concren JE E/M and after attending complaint he should give feedback and return the complaint slip to concern JE E/M in the evening at 17.30 Hrs on same day. (ii) Tradesman deployed for work should wear proper uniform with full shirt and full Pant. Colour code will be decided by EIC. (iii) Gyser complaint to be attend within 48 Hrs from the receiving of complaint , other wise panalty of Rs 100 per complaint per day will be imposed on contractor. In this decision of EIC and GE will full and final. (iv) Being a maintenance contract site will be handover to contractor as per complaint received from user and as per site requirement. (v) For any minor repair required in wiring or their is any fault in circuit where the item under repair is to be replaced, contractor has to identify and recitified the fault without any extra cost.
SUDHA ENTERPRISES
M/s Tekcon International
M/s Santosh Industrial Corporation
M/S C C CONSTRUCTION
M/S Jamuna Traders
Guru Charan Mahata
SUMAN CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .