Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-AOC 254 MG ROAD LAMBA LANE JUNGLIGHAT PORT BLAIR SOUTH ANDAMAN ANDAMAN AND NICOBAR ISLANDS 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹53.8 L+₹6.8 L (14.3%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹55.0 L+₹8.0 L (16.9%)Rejected-Finance MES WORKS SITE CARNICOBAR ANDAMAN NICOBAR ISLAND | CARNICOBAR | NICOBAR | ANDAMAN AND NICOBAR ISLANDS | 744301 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹56.5 L+₹9.4 L (20.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical not admitted |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
10 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I)(P)RW CARNICOBAR
GE(I)(P)RW CARNICOBAR
PROVISION OF 1x STORAGE ACCN OF GE(I)(P) CARNICOBAR AT AF STN CARNICOBAR
2021_MES_492798_1
8512/GE(I)(P)RW/E8
Open Tender
Civil Works
Item Rate
180 days
AREA UNDER GE(I)(P)RW CARNICOBAR
AS PER TENDER DOPCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE(I)(P)RW
₹94,000
Yes
3 Feb 2022
7 Dec 2021
12 Jan 2022
7 Dec 2021
10 Jan 2022
27 Dec 2021
60 days
Amount
(a) Bilding Work
Surface excavation n.exc 30 cm deep and average 15 cm deep and getting out in soft/ loose soil all as directed byEngineer in Charge.
Excavating in trenches , in hard/dense soil n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard dense soil complete all as directed by Engineer in Charge
All as per item No 1.02 but for each additional 1.5 m or part thereof in depth beyond the first 1.5 m n exc 3m in hard/dense soil
M&L for Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as directed by Enginer in Charge.
M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in foundations filling in mass concrete all as directed by Engineer n Charge.
M&L for PCC (1:2:4) type B2 using 40 mm graded stone aggregate as in foundations filling in mass concrete all as directed by Engineer in Charge.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in floor 100 mm thick complete all as specified and directed by Engr-in-Charge.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exc 25 cm all as directed by Engineer in Charge.
Removing excavated soil exc 50m upto a total distance of 250 m and depositing where directed at a level n exc 1.5m above the starting point all as directed by Engineer in Charge.
M&L for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area all as directed by Engineer in Charge.
M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface all as directed by Engineer in Charge.
M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface all as directed by Engineer in Charge.
M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area all as directed by Engineer in Charge.
M&L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall all as directed by Engineer in Charge.
M&L for approved good earth filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as directed by Engineer in Charge.
M&L Pre-cast cement concrete block masonry in (1:3:6) type C1 using 20mm graed stone aggregate with solid blocks, exc. 10 cm in width and setting in mortar complete CM (1:6), complete all as specified
M&L for 40mm thick Damp Proof Course in Cement concrete (1:2:4) Type B0 , using 12.5mm graded stone aggregate to horizontal or vertical surfaces including necessary formwork complete all as specified
M&L for RCC (1:1.5:3) Nominal Mix using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span, using 20mm graded stone aggregate all as specified & directed by Engineer inCharge.
M&L for RCC(1:1.5:3) Nominal Mix using 20mm graded stone aggregate as in Chajjas, using 20mm graded aggregate all as specified & directed by Engineer inCharge.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface all as specified & directed by Engineer inCharge.
M&L for formwork fair finished surfaces to chajjas,troughs and similar items including edges all as specified & directed by Engineer inCharge.
S&F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases,splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc Fe 410 W ( Gd E-250) all as specified & directed by Engineer inCharge.
S&F steel work in tubular tursses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade st -240 comolete all as specified and directed by Engr -in-Charge.
S & F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. all as specified & directed by Engineer inCharge.
S&F Structural steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, Fe-410-W(Gde- E-250) quality- B, with riveted, bolted or welded atachment complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof ridge, fixed with self tapping screws, complete all as specified and directed.
S&F 25 mm thick 2nd class hard wood boarding with nails in any situation (Except flooring and skirting) complete all as specified and directed by Engr-in-Charge
M & L Anodised aluminium snap grid frame work for false ceiling , including Hangers of 6mm dia G.I ( upto 1200mm length adjusting level fixed to roof slab by means of ceiling cleats made out of G.I flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified .
M&L 12mm thick perforated particle board/tiles for insulation and accoustic purpose ,60x60 cm in size,fixed with nails to timber frame work or with staples on snap grid, complete all as specified.
M&L for 1st quality Joint free Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat ement slurry and pointed in white or coloured cement to match over 15 mm screed bed in CM (1:6) all as specified & directed by Engineer in Charge.
All as per item no. 1.31 here in before but as verical surface such as skirting/dado , tile laid over and including 10mm thick rendering in CM(1:4) , neat cement slurry and jointed and pointed with white cement mixed with colour pigmnets to match the shade of tile all as directed by Engineer in Charge.
M&L for 20mm thick, Granite work (table rubbed and pre-polished) in steps, jambs, pillars, window- cills, cooking platforms and like, set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
M&L for Rendering 15mm thick on fair faces of brick or concrete surfaces in CM (1:6) finished even and smooth w/o using extra cement all as directed by Engineer in Charge.
M&L for Rendering 15mm thick on other than fair faces of brick or concrete surfaces in CM (1:4) finished even and smooth without using extra cement complete all as directed by Engineer in Charge.
M&L for preparation for new wooden untreated surfaces of any description exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer
M&L preparing of new surface of plaster or unplastereed on wall and applying two coats of oil bound distemper over a coat of Priming plastered all as directed by Engineer in Charge.
M&L preparing of new surface of plaster or unplastereed on wall and applying two coats of cement base paint over a coat of Priming plastered all as directed by Engineer in Charge.
M&L for preparation for new steel untreated surfaces of any description , over 10 cm in with of girth, not otherwise described two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified & directed by Engineer in Charge.
M&L for TMT steel bars 10mm dia and over to length bent to shape required, incl cranking bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as directed by Engineer in Charge.
All as per item no 1.40 above but 5mm dia & over upto and incl 10mm dia in stirrups, spacers and binders.
S&F coloured powder coated aluminium door frame and door shutter frame made of hallow extruded aluminium section of suitable size for door shutter with one or more rebate including joining cleats 2nd class soft wood piece in corner for tightening of screw etc. aluminium section of 1.6mm thickness to be used for door frame and lock rail of shutter of size will be 100mmX 44mm and door shutter bottom rail shall beof size 150mmx44mm styles and top rails of shutters shall be of size 83mmx44mm complete including fixing of heat resistant tinted glass 5mm thick as approved by Engr-in-Charge or 12mm thick pre-laminated particle board with lamination of both faces including necessary joining cleats, clips, aluminium snap beading rubber gasket etc complete in double or single leaf as specified and directed at site including following fixtures as under :- (a) 250mm long aluminium anodised barrel tower bolt of extruded section (02 Nos to each leaf) complete all as specified. (b) Half round aluminium alloy handle (02Nos of each leaf) (c) Mortice lock verticle type brass with duplicate key (04 levers) complete all as specified. (d) floor Door spring ISI marked steel body complete as directed by Engr-in-charge
S&F for Anodised aluminium grill (Min thickness 5.2mm and of 2.4Kg/Sqm weight) of approved design/ pattern, with approved standrad section and fixed to existing window frame with CP brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of engineer in charge.
S&F 1000 Litres Capacity, HDPE (Double layered) Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, Complete all as specified and directed.
S&F 20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball (Minimum weight 455 gms), complete all as specified and directed.
M&L 20 mm dia Gate valves with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed.
S & F CPVC 16mm bore, SDR -11 Grade for hot and cold water with all fittings fixed complete to walls and ceilings or laid in floors all as directed by Engineer in Charge.
S & F CPVC 20 mm bore, SDR -11 Grade for hot and cold water with all fittings fixed complete to walls and ceilings or laid in floors all as directed by Engineer in Charge.
M & L for vitreous china wash down water closet pan (pedastal pattern), including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device (excluding fixing bolts, flushing cistern and flush pipe) all as directed y Engineer in Charge.
S & F PVC valveless, syphonic action type flushing cistern 10 ltr capacity low level white with inlet ball valve float and handle including brackets, Flush pipe of polyethylene of low or high density or PVC 32mm dia, for low level cistern, all as specified and directed.
S & F for PVC Health faucet with all accessories, complete all as specified and directed.
S & F bip taps 15mm chromium plated cast copper alloy with crutch or butterfly handle, screw down for iron pipe or for brass ferrule all as specified & directed by Engineer in Charge
M & L for vitreous china wash basin of size 630 x 450mm, white, flat back, including brackets , 15mm bore pillar taps chromium plated, 32mm bore dia Waste coupling of PTMT (half or full threaded) , cutting for and pinning in ends of brackets or erecting stand, complete all as specified and directed.
S & F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed.
M & L for soap dish(PTMT) , any type, fixed to plugs with chromim plated brass screws all as directed by Engineer in Charge.
S&F for tubular towel rail, brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed.
S&F 15mm dia stop valves, fancy typ,e chromium plated, cast copper alloy, screwed down , high pressure, with crutch or butterfly handle , screwed both ends for iron pipe or for unions, complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm , complete all as specified and directed.
M & L PVC floor trap, 75 mm dia, with grating including jointing with solvent cement, complete all as specified and directed.
S&F 32 mm bore (LDPE) pipes of pressure rating 6 kgf/sqcm, in waste pipe of WHB / Sink, fixed complete to walls,ceiling or in floors etc all as specified and directed.
S & F PVC 75mm (SWR ) pipe single socketed in any length with rubbering joints fixed to walls, complete all as specified and directed.
S & F PVC (SWR) bend 75mm bore any radius complete all as specified and directed. .
S & F 110mm bore PVC (SWR ) pipe single socketed in any length with rubbering joints fixed to walls including removal of old damaged PVC pipe ,complete all as specified and directed.
S & F PVC (SWR) bend 110mm bore any radius all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 using 40mm graded stne aggegate as in plinth protection, surface finished even and smooth complete all as secified & directed by Engineer in Charge.
Road/ path/ hardstanding
Excavation over area n. exc 1.5 m deep and getting out soft soil al as directed by Engineer in Charge.Note- Removbal of soil shall be measured and paid seperetly under respective items here in before)
Moorum filling in pavings, laid in layers n exc 15 cm th, spread, levelled and rammed including watering allas specified & directed by Engineer in Charge.
M & L for PCC Type D-2, 1:4:8 (40 MM Graded stone aggregate), 75 mm thick as in hard standing , sirface finished fair & even complete all as specified & directed by Engineer in Charge.
M & L for sand filling under pavings tiles including watering and consolidation all as directed by Engineer in Charge.
M & L for machine coloured pressed precast concrete interlocking paver block (rubber moulded) any shape of 60mm thickness , confirming to IS:15658-2006, M-35 with grey cement and pigment complete all as specified and directed by Engineer in Charge.
Internal Electrification
M&L for Point wiring with PVC insulated 1.5 Sqmm multi stranded copper conductor cable 1100 volts grade drawn into and including concealed PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of anticorrosive paint outside and two coats of aluminium paint inside 2.8mm thick hylam brand laminated white bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer in Charge.
One light point controlled by one switch.
One fan point controlled by one switch.
One socket point controlled by one switch on same board.
One socket point controlled by one switch on Independent board 05 Amps.
One bell point controlled by one bell puse button independent board.
Description all as per item No 3.01 here in before but with 1100 volts grade copper standard conductor cable of size 2.5 Sqmm with 2.5 Sqmm solid copper conductor PVC for 3 pin switch socket outer 15 Amp independent board complete all as specified and directed by Engineer in charge.
M/L for Switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed. Make- Anchor or equivalent in Leader, Legrand, Havells
S&F for socket outlet 2 in 1, 3 pin 5 Amps and AC 230 volts flush type complete all as specified. Make- Anchor or equivalent in Leader, Legrand, Havells.
M/L for Bell push flush type single pole 240 volts 50 Hz all as specified and directed Make- Anchor or equivalent in Leader, Legrand, Havells.
M/L for Switch socket combination 2 in 1, 3 pin 5 Amps and AC 230 volts flush type complete all as specified. Make- Anchor or equivalent in Leader, Legrand, Havells
M/L for Switch socket combination 3 pin 15 Amps and AC 230 volts flush type complete all as specified and directed. Make- Anchor or equivalent in Leader, Legrand, Havells
M/L for Ceiling rose surface bakelite 65mm x 50mm three terminal AC 230 volts flush type complete all as specified and directed. Make- Anchor or equivalen in Leader, Legrand, Havells.
S&F fan regulator rotary type step 120/280 watt capacity of polycarbonate complete all as specified and directed. Make- Anchor or equivalent in Leader, Legrand, Havells
S&F Bell Buzzer AC, 240 volts single pole complete all as specified and directed Make- Anchor or equivalent in Leader, Legrand, Havells
Supply and fixing LED tube light fitting 20 watt with electronic driver ultra slim with extruded polycarbonate difuser for glare free light distribution complete all as specified and directed. Make- Havells Cat No. LHEXBLP7PN1W020 or equivalent in Philips, Bajaj, Crompton
Supply and fixing mirror light fitting 10 watt with lamp consists of pre wired high efficiency electronic driver high translucent frosted difuser for glare free smooth light distribution complete all as specified and directed. Make- Havells or equivalent in Phillips, Bajaj, Crompton.
S&F MCB DB IP 54 protection (double door) triple pole neutral 415 volts 4 way AC vertical Type including all electric connection with suitable lugs complete all as specified and as directed. Make- Havells Cat No. DHDLVDRWGOFO04 or equivalent in ABB, L&T.
S&F MCB single pole 240 volts 5 to 30 Amps, C Series complete all as specified and directed by Engineer in charge.
S&F ceiling fan of 1200 mm sweep 240 volts 5 star ratings complete with down rod canopy blades and hanging the same including connecting up complete with and including PVC insulated PVC sheathed copper conductor flexible cable 3 core 24/0.2mm from ceiling rose or connector to fan and marking of MES number. Note :- Length of suspension rod shall be adjusted by cutting, threading as directed by Engineer-in-Charge and its cost is deemed to be included in rate of hanging of ceiling fan.
M&L for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr deep below normal ground level, connected to GI earth wire 4mm dia by means of bolts, nuts, check nuts and washers of GI or steel and connected to earthing test point / distribution board / equipments or any other indicated situation all as shown in electrical plate No. 3 of SSR Part I (2009) and testing on completion including necessary excavation in any type of soil, returning filling, removing of soil and 1.5 mtr length GI medium grade 20mm dia pipe with funnel and wire mesh, PCC chamber or 1:2:4 type B1 using 20mm grade stone aggregate, 40mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 150mm c/c on both ways pre cast chamber cover with lifting handle 16mm dia round bars, GI pipe medium grade 20mm dia for earth strip protection including charcol, common salt complete all as specified and directed.
S&F MCCB 3 Pole, 415 V, fixed type, 50 Amps with breaking capacity 16 KA
Sub main wiring with 2 single core 4 Sqmm PVC insulated FRLS cable with multicore copper conductor drawn in and including PVC conduit of suitable size with and including independent PVC insulated 4 Sqmm single core copper earth wire complete all as specified (Note:-The cost of earth wire and cheasing in roof/wall is included in sub main wiring)
Sub main wiring with 2 single core 6 Sqmm PVC insulated FRLS cable with multicore copper conductor drawn in and including PVC conduit of suitable size with and including independent PVC insulated 6 Sqmm single core copper earth wire complete all as specified (Note:-The cost of earth wire and cheasing in roof/walls is included in sub main wiring)
S&F Sheet metal enclosure with socket, plug top and MCB 20A Single pole and Neutral complete all as specified and directed by Engineer-in-Charge
External Electrification
Supply , laying & testing XLPE insulated, armoured, heavy duty LT Cable with aluminium conductor, 1100 Volts grade of size 35 sqmm 3.5 core (form main panel to proposed MCB DB TPN) all as directed by Enginer in Charge.
S&F MCCB 3 pole 415 V, fixed type , 63 Amps with breaking capacity 16 KA complete all as directed by Engineer iin Charge
Supplying and laying DWC pipe of size 100/95mm for cable protection laid in trenches or on pole complete all as specified.
M&L for sand cushioning for underground cable 8 cm before laying cable and 15 cm after laying and stretching of cable complete all as specified (Note: Excavation shall be measured and paid here in before under respective item)
bansal construction
ASHOK BISWAS
DHAKSHNA MOORTHY AND SON
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .