Loading…
Loading…
Tender Value
₹11.4 Cr
EMD Value
₹22.8 L
Closing Date
25 Jun 2026, 3:00 pm
At GPZ and HMY: Additional work required to complete the Phase-I of work of "Under ABSS - Soft upgradation of GPZ, HMY stations - Improvement of Facade, entry Porch, Waiting hall, & circulating area. (Project id: 08.04.53.25.3.53.011)
23-ENGG-RNY-2026-27
23-ENGG-RNY-2026-27
Open
12 Months
Unknown (Unspecified Location)
₹0
₹22.8 L
2 Jun 2026
2 Jun 2026
11 Jun 2026
Wood and PVC Work, Aluminium Work, New Technologies and Material for Improvement of Facade,
entry Porch, Waiting hall and other associated works to soft upgrade.
S No. Item No Description of Item Unit Qty Rate Amount
9.0 WOOD AND P.V.C. WORK
9.1S FRAMES AND TRUSSES
Providing wood work in frames of doors,
windows, clerestory windows and other
frames, wrought framed and fixed in
9.1 position with hold fast lugs or with dash
fasteners of required dia & length (hold fast
lugs or dash fastener shall be paid for
Providing and fixing ISI marked flush door
shutters conforming to IS : 2202 (Part I)
decorative type, core of block board
construction with frame of 1st class hard
wood and well matched teak 3 ply
veneering with vertical grains or cross
bands and face veneers on both faces of
9.20.2 30 mm thick including ISI marked Stainless Sqm 26.95 3167.95 85376.25
Steel butt hinges with necessary screws
Extra for Providing and fixing flush doors
with decorative veneering instead of non
decorative ISI marked flush door shutters
conforming to IS: 2202 (Part I)
9.40S MISCELLANEOUS-WOOD WORK
Providing and fixing M.S. grills of required
pattern in frames of windows etc. with M.S.
9.48 flats, square or round bars etc. including
priming coat with approved steel primer all
9.48.2 Fixed to openings /wooden frames with rawl Kg 700 238.35 166845
plugs screws etc.
9.72S BRASS FITTINGS
Providing and fixing bright finished brass
9.74 tower bolts (barrel type) with necessary
screws etc. complete :
Providing and fixing bright finished brass
9.75 door latch with necessary screws etc.
RANGIYA DIVISION-ENGINEERING/N F RLY
9.76 Providing and fixing bright finished brass Each 15.56 854.65 13298.35
100 mm mortice latch and lock with 6
9 levers and a pair of lever handles of
approved quality with necessary screws etc.
Providing and fixing bright finished brass
handles with screws etc. complete:
9.82 Providing and fixing bright finished brass Each 31.11 121.65 3784.53
11 hanging type floor door stopper with
necessary screws, etc. complete.
9.84 Providing and fixing aluminium extruded Each 15.56 983.15 15297.81
section body tubular type universal
hydraulic door closer (having brand logo
with ISI, IS : 3564, embossed on the body,
door weight upto 36 kg to 80 kg and door
width from 701 mm to 1000 mm), with
double speed adjustment with necessary
accessories and screws etc. complete.
9.88S CHROMIUM PLATED BRASS FITTINGS
Providing and fixing chromium plated brass
9.92 handles with necessary screws etc.
ANODISED ALUMINIUM FITTINGS (ALL
FITTINGS SHALL BE ISI MARKED)
Providing and fixing ISI marked aluminium
butt hinges anodised (anodic coating not
9.95 less than grade AC 10 as per IS: 1868)
transparent or dyed to required colour or
shade with necessary screws etc.complete:
9.105S GYPSUM BOARD PARTITIONS
RANGIYA DIVISION-ENGINEERING/N F RLY
Providing and fixing factory made uPVC
glazed/wire mesh windows/ doors
comprising of lead free uPVC multi-
chambered frame, sash and mullion/coupler
(where ever required) extruded profiles
having minimum wall thickness of 1.70 mm
for Series R1 and R2 profiles and 2.10 mm
for Series R3 and R4 profiles conforming to
EN: 12608 in any shape, colour and design
duly reinforced with galvanized mild steel
section made of required shape & size as
per CPWD Specification, uPVC extruded
glazing beads, interlocks and Inline sash
adaptor (where ever required) of
appropriate dimension, EPDM gasket,
hardware, SS 304 grade fasteners of
minimum 8 mm dia with countersunk head,
comprising of matching polyamide PA6
grade sleeve for fixing frame to finished
wall as per IS 1367 : Part 1 to 14, plastic
9.147 packers, plastic caps and necessary
stainless steel screws etc. Profile of frame,
sash & mullion (if required) shall be mitred
cut and fusion welded/mechanically jointed
duly sealed at all corners, including drilling
of holes for fixing hardware and drainage of
water etc. After fixing frame the gap
between frame and adjacent finished wall
shall be filled with weather proof silicon
sealant over backer rod of approved size
and quality, all complete as per approved
drawing conforming to CPWD specification
& direction of Engineer-in-Charge. Section
of steel reinforcement and cross sections of
uPVC profiles to be as per design approved
by Engineer-in-Charge. Wire mesh / Glazing
of plain/ toughened/ laminated/ double
glass unit with / without high performance
coatings as per design requirements and
conforming to IS: 3548 & IS: 16231 shall be
paid separately.
Two track four panels sliding door with
Aluminium channel for roller track, wool
pile, zinc alloy (zamak) powder coated
handle on three panels along with multi-
point locking system, adjustable nylon
rollers with SS 304 body.
9.147.B2.1 Using R3 series with frame (55mm & above) Sqm 20.56 7345.35 151020.4
16 x (40mm & above) & sash (30mm & above)
x (74mm & above). (Height upto 2.5 meter).
Ventilator Casement window single panel
with or without fixed panel with S.S. 304
9.147.D1 friction hinges as per size and weight of
sash, single point locking zinc alloy (zamak)
powder coated handles
9.147.D1.2 Using R2 series with frame (39mm & above Sqm 17.78 12254.9 217892.12
) x (39mm & above) & sash /mullion (39mm
& above) x (60mm & above). (Height upto
9.147.D1.3 Using R3 series with frame (55mm & above Sqm 22.78 11919.85 271534.18
) x (45mm & above) & sash /mullion (55mm
& above) x (65mm & above). (Height above
Casement window single panel with S.S.
304 friction hinges as per size and weight
of sash, multi-point locking system, zinc
alloy (zamak) powder coated handles.
9.147.E1.1 Using R2 series with frame (39mm & above) Sqm 44.5 14449.25 642991.63
19 x (39mm & above) & sash (39mm & above)
x (60mm & above). (Height upto 1.2 meter)
RANGIYA DIVISION-ENGINEERING/N F RLY
21.0 ALUMINIUM WORK
21.1S General
Providing and fixing aluminium work for
doors, windows, ventilators and partitions
with extruded built up standard tubular
sections/ appropriate Z sections and other
sections of approved make conforming to
IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including
necessary filling up the gaps at junctions,
i.e. at top, bottom and sides with required
21.1 EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust
free, straight, mitred and jointed
mechanically wherever required including
cleat angle, Aluminium snap beading for
glazing / panelling, C.P. brass / stainless
steel screws, all complete as per
architectural drawings and the directions of
Engineer-in-charge. (Glazing, panelling and
dash fasteners to be paid for separately) :
21.1.1 For fixed portion
21.1.1.1 Anodised aluminium (anodised transparent Kg 116.67 495.05 57757.48
or dyed to required shade according to IS:
1868, Minimum anodic coating of grade AC
For shutters of doors, windows & ventilators
including providing and fixing hinges/ pivots
and making provision for fixing of fittings
wherever required including the cost of
EPDM rubber / neoprene gasket required
(Fittings shall be paid for separately)
21.1.2.1 Anodised aluminium (anodised transparent Kg 46.67 598.6 27936.66
or dyed to required shade according to IS:
1868, Minimum anodic coating of grade AC
Providing and fixing 12 mm thick
prelaminated particle board flat pressed
three layer or graded wood particle board
conforming to IS: 12823 Grade l Type ll, in
21.2 panelling fixed in aluminium doors, windows
shutters and partition frames with C.P.
brass / stainless steel screws etc. complete
as per architectural drawings and directions
of engineer-in-charge.
21.2.1 Pre-laminated particle board with Sqm 27.22 1139.3 31011.75
22 decorative lamination on one side and
balancing lamination on other side
Providing and fixing glazing in aluminium
door, window, ventilator shutters and
partitions etc. with EPDM rubber / neoprene
21.3 gasket etc. complete as per the
architectural drawings and the directions of
engineer-in-charge . (Cost of aluminium
snap beading shall be paid in basic item):
21.3.1 With float glass panes of 4.0 mm thickness Sqm 27.22 1176.8 32032.5
(weight not less than 10kg/sqm)
RANGIYA DIVISION-ENGINEERING/N F RLY
Providing and fixing double action hydraulic
floor spring of approved brand and
manufacture conforming to IS : 6315,
having brand logo embossed on the body /
plate with double spring mechanism and
door weight upto 125 kg, for doors,
21.4 including cost of cutting floors, embedding
in floors as required and making good the
same matching to the existing floor
finishing and cover plates with brass pivot
and single piece M.S. sheet outer box with
slide plate etc. complete as per the
direction of Engineer-in-charge.
21.4.1 With stainless steel cover plate minimum Each 7.78 2823.85 21969.55
1.25 mm thickness
21.4.2 With brass cover plate minimum 1.25 mm Each 3.11 2966.1 9224.57
21.18 Providing and fixing 12 mm thick frameless Sqm 7.78 5325.9 41435.5
toughened glass door shutter of approved
brand and manufacture, including providing
and fixing top & bottom pivot & double
acting hydraulic floor spring type fixing
arrangement and making necessary holes
etc. for fixing required door fittings, all
complete as per direction of Engineer-in-
charge (Door handle, lock and stopper etc.
to paid separately)
STRUCTURAL GLAZING ALUMINIUM
COMPOSITE PANEL
25.1S General
25.8 Design supply & installation of suspended Sqm 44.5 9502.35 422854.58
Spider Glazing system designed to
withstand the wind pressure as per IS 875
(Part-III). The Suspended System held with
Spider Fittings of SS-316 Grade Steel of
approved manufacturer with glass panel
having 12 mm thick clear toughened glass
held together with SS- 316 Grade Stainless
steel Spider & bolt assembly with laminated
glass fins 21 mm thick. The Glass fins and
glass panel assembly shall be connected to
Slab/beams by means of SS- 316 Grade
stainless steel brackets & Anchor bolts and
at the bottom using SS channel of 50x25x2
mm using fastener & anchor bolts, non
staining weather sealants of approved
make, Teflon/ nylon bushes and separators
to prevent bi-metallic contacts, all complete
to perform as per specification and
27 approved drawings. The complete system to
be designed to accommodate thermal
expansion & seismic movements etc. The
joints between glass panels (6 to 8 mm)
and gaps at the perimeter & in U channel of
the assembly to be filled with non staining
weather sealant, so as to make the entire
system fully water proof & dust proof. The
rate shall include all design, Engineering
and shop drawing including approval from
structural designer, labour, T&
P,scaffolding, other incidental charges
including wastage, enabling temporary
services all fitting fixers nut bolts, washer,
Buffer plates, fastener, anchors,SS channel
laminated glass etc. all complete. For the
purpose of payment, actual elevation area
of Glazing including thickness of joints and
the portion of Glass panel inside the SS
channel shall be measured.
26.0 NEW TECHNOLOGIES AND MATERIALS
RANGIYA DIVISION-ENGINEERING/N F RLY
26.1S General
Providing and fixing at Bamboo Mat board
conforming to IS:13958-1994 for partition
26.6D to frame by bucking or studding with
screws etc. complete (Frames, backing or
studding to be paid separately)
26.73S PREFAB/PRECAST TECHNOLOGY
Providing and fixing factory made single
extruded WPC (Wood Polymer Composite)
solid door/window/Ceosetory windows &
other Frames/Chowkhat comprising of
virgin PVC polymer of K value 58-60
(Suspension Grade), calcium carbonate and
natural fibers (wood powder/ rice husk/
wheat husk) and non toxic additives
(maximum toxicity index of 12 for 100 gms)
fabricated with miter joints after applying
PVC solvent cement and screwed with full
body threaded star headed SS screws
having minimum frame density of 750
kg/cum, screw withdrawal strength of 2200
N (Face) & 1100 N (Edge), minimum
compressive strength of 58 N/mm2,
modulus of elasticity 900 N/mm2 and
resistance to spread of flame of Class A
category with property of being
termite/borer proof, water/moisture proof
and fire retardant and fixed in position with
M.S hold fast/lugs/SS dash fasteners of
required dia and length complete as per
direction of Engineer-In- Charge. (M.S hold
fast/lugs or SS dash fasteners shall be paid
for separately).
Providing and fixing factory made single
extruded WPC (Wood Polymer Composite)
solid decorative type flush door shutter of
required size comprising of virgin polymer
of K value 58-60 (Suspension Grade),
calcium carbonate and natural fibers (wood
powder/ rice husk/wheat husk) and non
toxic additives (maximum toxicity index of
12 for 100 gms) having minimum density of
650 kg/cum and screw withdrawal strength
of 1800 N (Face) & 900 N (Edge), minimum
compressive strength 50 N/mm2, modulus
of elasticity 850 N/mm2 and resistance to
spread of flame of Class A category with
property of being termite/borer proof,
water/moisture proof and fire retardant.
WPC to be laminated with PVC foil of
minimum 14 microns thick of approved
design pasted with hot melt adhesive on
both faces of shutter and fixing with
stainless steel butt hinges of required size
with necessary full body threaded star
headed counter sunk S.S screws, all as per
direction of Engineer-In- Charge.
RANGIYA DIVISION-ENGINEERING/N F RLY
Providing and fixing of facade at all heights
with extruded hollow Clay / Terracotta
ventilated rainscreen tiles of height 250/
300/ 400 mm and length of 595 mm of
approved texture, design and pattern
having Flexural Strength/ Modulus of
Rupture of >=14 N/m2 and maximum
water absorption of 10% tested as per ISO
respectively in true level fixed to a
supporting aluminium framework (Alloy
6063 T5/T6) consisting of vertical 'T' (for
intermediates)/ 'L'(for ends/ termination)/
Tubular sections (at corners) of size
80x60x2 mm/ 40x60x2 mm/ 40x40x2 mm
respectively, spaced at maximum spacing
of 600 mm c/c matching to the tile vertical
grid, and horizontal aluminium 'C'-clamps of
size 56x25x2 mm thickness of length 150
mm at junction of tiles and of length 75 mm
at wall ends/ corners fixed on top of the
vertical sections at spacing of 250/ 300/
400 mm c/c matching to the tile horizontal
grid with two numbers of self-drilling / self-
tapping SS screws of size 5.5x25 mm with
EPDM washers. The vertical 'T'/'L/ Tubular'
sections shall be fixed to the wall using
HDG (hot-dip-galvanized) steel L-brackets
(galvanizing thickness of minimum 80
microns) of size 110x80x6 mm at
intermediate vertical aluminium profiles
and of size 220x110x12 mm at outer
corners and stainless steel grade 304, M10
full threaded anchor fasteners with nylon
sleeve 100 mm long (for brick work) and M8
expansion anchor fasteners 75 mm long for
concrete surface, spacing of brackets to be
based on a structural/ static calculation.
The brackets shall be of length 175 mm at
junction of two vertical aluminium profiles
and of length 100 mm at intermediate
points of vertical profiles and shall be fixed
to the vertical aluminium T / L / Tubular
profiles using two numbers self-drilling/ self-
tapping SS screws of size 5.5x25 mm with
EPDM washers. EPDM gaskets to be fixed in
between brackets and vertical profiles. The
tiles shall be mounted on the 'C' clamps
such that the tiles are supported at top and
bottom at both ends. The tiles shall be
additionally secured to the horizontal 'C'
clamps using special SS clips of required
size which shall be inserted and pressed
into position on the 'C' clamps holding the
tiles and the cut-tiles shall be glued at
points to the horizontal 'C' clamps by using
MS Polymer sealant adhesive. The vertical
joint open groove between two adjacent
tiles shall be 5 mm. The tiles and system
shall be designed to resist wind load as per
IS 875 (Part 3) according to different zones.
The tiles shall be installed using the
ventilated rain screen principle with
provision for natural ventilation of the space
between the facade tiles and the structural
wall. The work shall be carried out as per
specification, drawing and as per direction
of the Engineer-in-Charge.
tiles of other than grey colors
RANGIYA DIVISION-ENGINEERING/N F RLY
Schedule Schedule G-DSR-2023 Items for Roofing
Roofing works for Improvement of Facade, entry Porch, Waiting hall and other associated works to
S No. Item No Description of Item Unit Qty Rate Amount
12.0 ROOFING
12.37S RAIN WATER SPOUT AND PIPE
Providing and fixing on wall face
unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS :
5382, leaving 10 mm gap for thermal
expansion, (i) Single socketed pipes.
Providing and fixing on wall face
unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain
12.42 water pipes conforming to IS : 13592 Type
A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap
for thermal expansion.
12.42.3 Single tee with door
12.42.4 Single tee without door
12.42.5 Bend 87.5 degree
12.42.6 Shoe (Plain)
Providing and fixing unplasticised -PVC pipe
clips of approved design to unplasticised -
PVC rain water pipes by means of 50x50x50
mm hard wood plugs, screwed with M.S.
screws of required length, including cutting
brick work and fixing in cement mortar 1:4
(1 cement : 4 coarse sand) and making
good the wall etc. complete.
12.50 Providing and fixing precoated galvanised Sqm 980.2 738.65 724024.73
iron profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-
charge) of total coated thickness 0.50 mm
(base metal of minimum 0.45 mm thickness
with total coating thickness of 0.05 mm)
with zinc coating 120 grams per sqm as per
IS: 277, in 240 mpa steel grade, 5-7
microns epoxy primer on both side of the
sheet and polyester top coat 15-18
microns. Sheet should have protective
guard film of 25 microns minimum to avoid
scratches during transportation and should
be supplied in single length upto 12 metre
or as desired by Engineer-in-charge. The
sheet shall be fixed using self drilling /self
tapping screws of size (5.5x 55 mm) with
EPDM seal, complete upto any pitch in
horizontal/ vertical or curved surfaces,
excluding the cost of purlins, rafters and
trusses and including cutting to size and
shape wherever required.
RANGIYA DIVISION-ENGINEERING/N F RLY
Providing and fixing precoated galvanised
steel sheet roofing accessories of total
coated thickness 0.50 mm (base metal of
minimum 0.45 mm thickness with total
coating thickness of 0.05 mm) with Zinc
coating 120 grams per sqm as per IS: 277,
in 240 mpa steel grade, 5-7 microns epoxy
primer on both side of the sheet and
polyester top coat 15-18 microns using self
drilling/ self tapping screws complete :
Schedule Schedule H-DSR-2023 Items for Sanitary, Water Supply & Drainage
Sanitary, Water Supply & Drainage for Improvement of Facade, entry Porch, Waiting hall and other
associated works to soft upgrade.
S No. Item No Description of Item Unit Qty Rate Amount
17.0 SANITARY INSTALLATIONS
17.1S General
Providing and fixing water closet squatting
pan (Indian type W.C. pan ) with 100 mm
sand cast Iron P or S trap, 10 litre low level
white P.V.C. flushing cistern, including flush
17.1 pipe, with manually controlled device
(handle lever) conforming to IS : 7231,with
all fittings and fixtures complete, including
cutting and making good the walls and
floors wherever required:
17.1.1 White Vitreous china Orissa pattern W.C. Each 4.67 6767.4 31603.76
1 pan of size 580x440 mm with integral type
Providing and fixing white vitreous china
flat back half stall urinal of size
580x380x350 mm with white PVC
automatic flushing cistern, with fittings,
standard size C.P. brass flush pipe,
17.5 spreaders with unions and clamps (all in
C.P. brass) with waste fitting as per IS :
2556, C.I. trap with outlet grating and other
couplings in C.P. brass, including painting of
fittings and cutting and making good the
walls and floors wherever required :
17.5.1 Single half stall urinal with 5 litre P.V.C. Each 7 12071.75 84502.25
automatic flushing cistern
Providing and fixing wash basin with C.I.
brackets, 15 mm C.P. brass pillar taps, 32
mm C.P. brass waste of standard pattern,
including painting of fittings and brackets,
cutting and making good the walls wherever
17.7.3 White Vitreous China Wash basin size Each 9.33 2301.75 21475.33
3 550x400 mm with a pair of 15 mm C.P.
brass pillar taps
17.7.8 White Vitreous China Surgeon type wash Each 12 3600.6 43207.2
basin of size 660x460 mm with a pair of 15
mm C.P. brass pillar taps with elbow
including operated levers
17.8 Providing and fixing white vitreous china Each 9.33 1683.35 15705.66
pedestal for wash basin completely
recessed at the back for the reception of
pipes and fittings.
17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet Each 4.67 349.15 1630.53
with flexible tube upto 1 metre long with
6 S.S. triangular plate to European type W.C.
of quality and make as approved by
Engineer - in - charge.
RANGIYA DIVISION-ENGINEERING/N F RLY
17.22B Providing and fixing CP Brass Single lever Each 3.12 6940.75 21655.14
telephonic wall mixer of quality and make
as approved by Engineer in charge.(a) 15
Providing and fixing P.V.C. waste pipe for
17.28 sink or wash basin including P.V.C. waste
fittings complete.
17.28.2 Flexible pipe
17.31 Providing and fixing 600x450 mm bevelled Each 13.33 1607.95 21433.97
edge mirror of superior glass (of approved
9 quality) complete with 6 mm thick hard
board ground fixed to wooden cleats with
C.P. brass screws and washers complete.
Providing and fixing mirror of superior glass
(of approved quality) and of required shape
17.32 and size with plastic moulded frame of
approved make and shade with 6 mm thick
hard board backing :
17.33 Providing and fixing 600x120x5 mm glass Each 9.33 1083.5 10109.06
shelf with edges round off, supported on
anodised aluminium angle frame with C.P.
brass brackets and guard rail complete
fixed with 40 mm long screws, rawl plugs
etc., complete.
17.34 Providing and fixing toilet paper holder :
17.56 Providing and fixing terminal guard :
17.71 Providing and fixing PTMT liquid soap Each 15.33 168.35 2580.81
container 109 mm wide, 125 mm high and
112 mm distance from wall of standard
shape with bracket of the same materials
with snap fittings of approved quality and
colour, weighing not less than 105 gms.
17.72 Providing and fixing PTMT towel ring Each 8.67 231.95 2011.01
trapezoidal shape 215 mm long, 200 mm
wide with minimum distances of 37 mm
from wall face with concealed fittings
arrangement of approved quality and
colour, weighing not less than 88 gms.
Providing and fixing PTMT towel rail
complete with brackets fixed to wooden
17.73 cleats with CP brass screws with concealed
fittings arrangement of approved quality
17.73.2 600 mm long towel rail with total length of Each 8.67 708.95 6146.6
16 645 mm, width 78 mm and effective height
of 88 mm, weighing not less than 190 gms.
17.78 Providing and fixing white vitreous china Each 15.67 14999.15 235036.68
extended wall mounting water closet of size
780x370x690 mm of approved shape
including providing & fixing white vitreous
17 china cistern with dual flush fitting, of
flushing capacity 3 litre/ 6 litre (adjustable
to 4 litre/ 8 litres), including seat cover, and
cistern fittings, nuts, bolts and gasket etc
18.0 WATER SUPPLY
18.4S PP-R PIPES
RANGIYA DIVISION-ENGINEERING/N F RLY
Providing and fixing 3 layer PP-R (Poly
propylene Random copolymer) pipes
confirming to IS:15801 UV stabilized & anti -
microbial fusion welded, having thermal
stability for hot & cold water supply,
including all PP - R plain & brass threaded
polypropylene random fittings, including
trenching, refilling & testing of joints
complete as per direction of Engineer-in-
Charge. External work
18.7S C.P.V.C. PIPES
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply,
including all CPVC plain & brass threaded
fittings and fixing the pipe with clamps at
1.00 m spacing. This includes jointing of
18.8 pipes & fittings with one step CPVC solvent
cement and the cost of cutting chases and
making good the same including testing of
joints complete as per direction of Engineer
in Charge. Concealed work, including
cutting chases and making good the walls
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply
including all CPVC plain & brass threaded
18.9 fittings This includes jointing of pipes &
fittings with one step CPVC solvent cement,
trenching, refilling & testing of joints
complete as per direction of Engineer in
Charge. External work
C.I. SLUICE VALVES/ FIRE HYDRANTS &
Providing and fixing C.I. sluice valves (with
cap) complete with bolts, nuts, rubber
insertions etc. (the tail pieces if required
will be paid separately) :
18.31.1 100 mm diameter
18.49S C.P. BRASS FITTINGS
Providing and fixing C.P. brass bib cock of
approved quality conforming to IS:8931 :
Providing and fixing C.P. brass long nose
bib cock of approved quality conforming to
IS standards and weighing not less than 810
RANGIYA DIVISION-ENGINEERING/N F RLY
Providing and fixing C.P. brass stop cock
18.52 (concealed) of standard design and of
approved make conforming to IS:8931.
Providing and fixing C.P. brass angle valve
18.53 for basin mixer and geyser points of
approved quality conforming to IS:8931
19.0 DRAINAGE
19.1S STONE WARE PIPES AND FITTINGS
Providing, laying and jointing glazed
stoneware pipes class SP-1 with stiff
19.1 mixture of cement mortar in the proportion
of 1:1 (1 cement : 1 fine sand) including
testing of joints etc. complete :
Providing and laying cement concrete
1:5:10 (1 cement : 5 coarse sand :10
19.3 graded stone aggregate 40 mm nominal
size) up to haunches of S.W. pipes including
bed concrete as per standard design :
Schedule Schedule I-DSR-2023 Items for Road Work
Item- 1 Improvement of circulating area and other associated works related to soft upgrade
S No. Item No Description of Item Unit Qty Rate Amount
16.0 ROAD WORK
16.1S ROADS
16.1 Preparation and consolidation of sub grade Sqm 16000 218.9 3502400
with power road roller of 8 to 12 tonne
capacity after excavating earth to an
average of 22.5 cm depth, dressing to
camber and consolidating with road roller
including making good the undulations etc.
and re-rolling the sub grade and disposal of
surplus earth with lead upto 50 metres.
16.3 Supplying and stacking at site.
16.4 Laying, spreading and compacting stone cum 3200 1046.95 3350240
aggregate of specified sizes to WBM
specifications in uniform thickness, hand
picking, rolling with 3 wheeled
road/vibratory roller 8-10 tonne capacity in
stages to proper grade and camber,
applying and brooming requisite type of
screening / binding material to fill up
interstices of coarse aggregate, watering
and compacting to the required density .
16.49S MISCELLANEOUS
RANGIYA DIVISION-ENGINEERING/N F RLY
16.50 Providing and fixing Glow studs of size Each 600 206.3 123780
100x20 mm made of heavy duty body shall
be moulded ASA (Acrylic styrene
Acrylonitrile ) or HIP (High impact
polystyrene) or ABS having electronically
welded micro- prismatic lens with abrasion
resistant coating as approved by Engineer
in charge. The glow stud shall support a
load of 13635 kg tested in accordance with
ASTM D4280. The slope of retro- reflective
surface shall be 35 (+/-5) degress to base
.The reflective panels on both sides with at
least 12 cm of reflective area up each side.
The luminance intensity should be as per
the specification and shall be tested as
described in ASTM I: 809 as recommended
in BS: 873 part 4 : 1973. The studs shall be
fixed to the Road surface using the
adhesive conforming to IS, as per procedure
recommended by the manufacturer
complete and as per direction of Engineer-
Manufacturing, supplying and fixing retro
reflective sign boards made up of 2 mm
thick aluminium sheet, face to be fully
covered with high intensity encapsulated
type heat activated retro reflective sheeting
conforming to type - IV of ASTM-D 4956-01
in blue and silver white or other colour
combination including subject matter,
message (bi-lingual), symbols and borders
etc. as per IRC ; 67:2001, pasted on
substrate by an adhesive backing which
shall be activated by applying heat and
pressure conforming to class -2 of ASTM-D-
4956-01 and fixing the same with suitable
sized aluminium alloy rivets @ 20 cm c/c to
back support frame of M.S. angle iron of
size 25x25x3 mm along with theft resistant
measures, mounted and fixed with 2 Nos.
M.S. angles of size 35x35x5 mm to a
vertical post made up to M.S. Tee section
ISMT 50x50x6 mm welded with base plate
of size 100x100x5 mm at the bottom end
and including making holes in pipes, angles
flats, providing & fixing M.S. message plate
of required size, steel work to be painted
with two or more coats of synthetic enamel
paint of required shade and of approved
brand & manufacture over priming coat of
zinc chromate yellow primer (vertical MS-
Tee support to be painted in black and
white colours).Backside of aluminium sheet
to be painted with two or more coats of
epoxy paint over and including appropriate
priming coat including all leads and lifts
etc. complete as per drawing , specification
and direction of Engineer-in-charge.
16.59.1 Mandatory/ Regulatory sign boards of 900 Each 10 7183.35 71833.5
5 mm diametre with support length of 3750
16.59.2 Cautionary /warning sign boards of Each 10 5559.75 55597.5
equilateral triangular shape having each
side of 900 mm with support length of 3650
RANGIYA DIVISION-ENGINEERING/N F RLY
Manufacturing, supplying and fixing retro
reflective overhead signage boards made
up of 2 mm thick aluminium sheet, face to
be fully covered with high intensity and
encapsulated lens type heat activated retro
reflective sheeting conforming to type - III
of ASTM-D-4956-01 as approved by
Engineer-in-charge, letters, borders etc. as
per IRC : 67-2001 in silver white with blue
colour back ground and with high intensity
grade, pasted on substrate by pressure
sensitive adhesive backing which shall be
activated by applying pressure conforming
to class II of ASTM-D-4956-01 and fixing the
same to the plate of structural frame work
by means of suitable sized aluminium
16.60 alloys, rivets or bolts & nuts @ 300 mm
centre to centre all along the periphery as
well as in two vertical rows along with theft
resistant measures, including the cost of
painting with two or more coats of epoxy
paint in grey colour on the back side of
aluminium sheet including appropriate
priming coat. The rate includes the cost of
rounding off the corners, lowering down the
structural frame work from the gantry,
fixing and erecting the same in position all
complete as per drawings, specification and
direction of the engineer-in-charge.
(Structural frame work including M.S. plate
to be provided separately. Rectangular area
of the sheet only shall be measured for
7 16.60.1 Overhead informatory road signage Sqm 25 5879.9 146997.5
16.62 Providing and applying 2.5 mm thick road Sqm 720 747.8 538416
marking strips (retro- reflective) of specified
shade/ colour using hot thermoplastic
material by fully/ semi automatic
thermoplastic paint applicator machine
fitted with profile shoe, glass beads
dispenser, propane tank heater and profile
shoe heater, driven by experienced
operator on road surface including cost of
material, labour, T&P, cleaning the road
surface of all dirt, seals, oil, grease and
foreign material etc. complete as per
direction of Engineer-in-charge and
accordance with applicable specifications.
16.69 Providing and laying at or near ground level cum 15 10117.6 151764
factory made kerb stone of M-25 grade
cement concrete in position to the required
line, level and curvature, jointed with
cement mortar 1:3 (1 cement: 3 coarse
sand), including making joints with or
without grooves (thickness of joints except
9 at sharp curve shall not to more than 5mm),
including making drainage opening
wherever required complete etc. as per
direction of Engineer-in-charge (length of
finished kerb edging shall be measured to
calculate volume for payment). (Precast
C.C. kerb stone shall be approved by
Engineer-in-charge).
RANGIYA DIVISION-ENGINEERING/N F RLY
Providing and laying gang saw cut 30 mm
thick, mirror polished pre moulded and pre
polished machine cut granite stone of
required size and shape of approved shade,
colour and texture in footpath, flooring in
road side plazas and similar locations, laid
over 20mm thick base of cement mortar 1:4
(1 cement : 4 coarse sand) including
grouting the joints with white cement mixed
with matching pigment, epoxy touch ups
etc. complete as per direction of Engineer-
16.87.2 With granite stone of all colour except Sqm 75 5272.05 395403.75
10 black, cherry/ruby red of area less than
16.90 Providing and laying tactile tile (for vision Sqm 85 2017.6 171496
impaired persons as per standards) of size
300x300x9.8mm having with water
absorption less than 0.5% and conforming
to IS:15622 of approved make in all colours
and shades in for outdoor floors such as
11 footpath, court yard, multi modals location
etc., laid on 20mm thick base of cement
mortar 1:4 (1 cement : 4 coarse sand) in all
shapes & patterns including grouting the
joints with white cement mixed with
matching pigments etc. complete as per
direction of Engineer-in-Charge.
Providing and laying factory made
chamfered edge Cement Concrete paver
blocks in footpath, parks, lawns, drive ways
or light traffic parking etc, of required
strength, thickness & size/ shape, made by
table vibratory method using PU mould, laid
in required colour & pattern over 50mm
thick compacted bed of sand, compacting
and proper embedding/laying of inter
locking paver blocks into the sand bedding
layer through vibratory compaction by
using plate vibrator, filling the joints with
sand and cutting of paver blocks as per
required size and pattern, finishing and
sweeping extra sand. complete all as per
direction of Engineer-in-Charge.
with approved color design and pattern.
Schedule Schedule J-DSR-2023 Items for Dismantling Work
Dismantling Work for Improvement of Facade, entry Porch, Waiting hall and other associated works
to soft upgrade.
S No. Item No Description of Item Unit Qty Rate Amount
15.0 DISMANTLING AND DEMOLISHING
15.1S General
Demolishing cement concrete manually/ by
mechanical means including disposal of
material within 50 metres lead as per
direction of Engineer - in - charge.
(including equivalent design mix)
Demolishing brick work manually/ by
mechanical means including stacking of
15.7 serviceable material and disposal of
unserviceable material within 50 metres
lead as per direction of Engineer-in-charge.
RANGIYA DIVISION-ENGINEERING/N F RLY
Dismantling doors, windows and clerestory
windows (steel or wood) shutter including
15.12 chowkhats, architrave, holdfasts etc.
complete and stacking within 50 metres
Dismantling steel work in single sections
15.17 including dismembering and stacking within
50 metres lead in:
15.29 Dismantling stone slab roofing over wooden cum 777.78 2664.65 2072511.48
karries or R.C.C. battens (dismantling
karries and battens to be paid for
6 separately), including stacking of
serviceable material and disposal of
unserviceable material within 50 metres
Dismantling manually/ by mechanical
means including stacking of serviceable
15.43 material and disposal of unserviceable
material within 50 metres lead as per
direction of Engineer-in-charge :
15.56 Dismantling old plaster or skirting raking Sqm 1555.56 54.65 85011.35
out joints and cleaning the surface for
plaster including disposal of rubbish to the
dumping ground within 50 metres lead.
Dismantling Work for Improvement of circulating area and other associated works related to soft
S No. Item No Description of Item Unit Qty Rate Amount
15.0 DISMANTLING AND DEMOLISHING
15.1S General
Dismantling manually/ by mechanical
means including stacking of serviceable
15.43 material and disposal of unserviceable
material within 50 metres lead as per
direction of Engineer-in-charge :
Schedule Schedule K-NS items
Item- 2 NS item for Improvement of circulating area and other associated works related to soft upgrade
S No. Item No Description of Item Unit Qty Rate Amount
1 1 Supplying, spreading and consolidating cum 2400.00 944.34 2266416.00
unscreened shingle (Ave. % of sand to
shingle is 50 : 50 & max. limit 60 : 40) for
road and other works as per direction of the
engineer or his authorised representative at
site, including all leads, lifts, descends &
carrying by truck, whereever necessaary,
arranged by the Contractor's at his own
cost including spreading in layers of 30cm
or less, levelling, dressing with
mechanical/manual compaction as per
given profile and as per N.F. Rly standard
specification & special condition corrected
upto date. The rate includes royalty,
monopoly, all taxes and other charges
complete in all respect. (N/S)
Item Breakup - A-DSR 2023 Items for Earthwork
Item Breakup - B-DSR-2023 items for Concrete Work (PCC & RCC)
Item Breakup - C-DSR-2023 items for Reinforcement & Steel Work
Item Breakup - D-DSR-2023 items for Masonry, Cladding & Finishing Work
Item Breakup - E-DSR 2023 items for Flooring Work
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
2026_03_13AdvanceCorrectionSlipNo_11.pdf ACS11
ATTACHMENT
TD_23-ENGG-RNY-2026-27_1.pdf
ATTACHMENT
2026_03_13AdvanceCorrectionSlipNo_11.pdf
ATTACHMENT
Download all tender documents and submit your bid