Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical As per Technical Evaluation Sheet |
| 2 | Accepted-Technical | Accepted-Technical As per Technical Evaluation Sheet |
| 3 | Accepted-Technical | Accepted-Technical As per Technical Evaluation Sheet |
| 4 | Accepted-Technical | Accepted-Technical As per Technical Evaluation Sheet |
| 5 | Accepted-Technical | Accepted-Technical As per Technical Evaluation Sheet |
Tender Value
₹41.5 L
EMD Value
₹90,000
Closing Date
10 Apr 2026, 4:00 pmClosed
Chief Engineer, PWD (Border Roads), Assam
O/o The Chief Engineer, PWD (Border Roads), Assam, Chandmari, Guwahati-03
Construction of Road including Cross Drainage works and 5 years Routine Maintenance for Package No. AS11973
2026_CEASM_146895_152
CE/PMGSY/01/2025-26/3
National Competitive Bid
Civil - Roads and Bridges
Item Rate
365 days
Kamrup Rural
Refer Tender Documents
15 documents required · 15 mandatory
₹900
₹90,000
Yes
2 Jun 2026
13 Mar 2026
13 Apr 2026
13 Mar 2026
10 Apr 2026
13 Mar 2026
13 Mar 2026 - 10 Apr 2026
Construction of Road from Railway Station to Lampara including Cross-Drainage works and Routine Maintenance of the works for 5 years
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. i. By Manual Means (A) In area of non thorny jungle
Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause
Construction of Sub-grade and earthen shoulder with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead up to 1000m as per Technical Specification Clause 303.1
Construction of Granular sub-base by providing well-graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix-in place method with rotavator at OMC and compacting smooth wheel roller to achieve the desired density, complete as per clause 401 as per Technical Specification
Providing, laying, spreading and compacting graded stone aggregate to wet mix macdam as per specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.
Construction of Panelled Concrete Pavement, Construction of panelled cement concrete pavement as per design by laying M30 grade concrete over a prepared sub base, with 53 grade Ordinary Portland Cement(OPC) or any other type as per Clause 1501.2.4, coarse and fine aggregates conforming to IS: 2386, mixing in a concrete mixer of not less than 0.2 cum capacity and appropiate weigh batcher using approved mix design (As per IRC:44-2008), in approved fixed side formwork (steel channe, wedges, steel plates including levelling the formwork as per drawing), maitaining camber of about 3 to3.5%, spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation, cutting panels of required size/ depth as per design immediately after 24 hours of laying, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification and as directed by the Engineer.
Providing Concrete Haunching of M20 grade at the edge of Panel concrete of 200mm width.
Reinforced cement concrete M15 grade Kilometre stone /local stone of standard design as per IRC:8 fixing in position including painting and printing etc. as per drawing and Technical specification Clause 1703 Ordinary K.M. stone (precast)
Reinforced cement concrete M15 grade Hectometre stone /local stone of standard design as per IRC:8 fixing in position including painting and printing etc. as per drawing &Technical specification Clause 1703 (iii) 200 mt stone (precast)
Providing and fixing of Reference Bench Mark / Temporary Bench Mark having section .0.35X.0.35 M and height 0.30 M above ground level in B/W 1:3 as per drawing and technical specifications
Providing and erecting direction and place identification retro-refiectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide 1701.2.3, fixed over aluminium composite panel sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by meanes of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701.
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. Hazard Markers (300mmX900mm)
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. Warning Signs [600mm -Triangle]
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. Stop Sign [600mm -Cricular]
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. Chevron Signs [600mmx450mm]
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Providing & fixing Logo Board of PRADHAN MANTRI GRAM SADAK YOGNA (Figure 1(A) & 1(B))as per standard design of National Rural Infrastructure development agency, diamond size (600 X 600 mm) 3 mm thick ACM plate and board plate size (1100 X 300 mm) 3 mm thick ACM plate and 2.4 m deep length square hollow section (75 X 75 X 6 mm) size including fitting and painting lettering with retroreflective sheeting class B as per drawing incl. fixing in CC M20 (450 X 450 X 600 mm) as per IRC 67
Providing & fixing of Typical PMGSY Citizen's information board consisting of two Aluminium Composite Material (ACM), 4mm thick face to be fully covered with high intensity prismetic sheeting type-4 class A/B material specification as per clause 1701.3.7. ACM sheets shall be of size 900mmX750mm each welded over welded MS flat iron frame of 50mm x 6mm size on back on edges. The flat iron frame of the bottom plate will be welded to 1 no. 75mm x 75mm x 6mm Square tube post. The steel tube post will be embedded in cement concrete M15 grade of 600mm x 600mm x 750mm below ground level. The height of lowermost part of the bottom plate will be 650 mm from normal ground level. The lettering and border etc. of ACM sheets on top & bottom shall be as per clause 1701.4.6 messages/borders. All the sections of frame and posts will be painted with primer and two coats of epoxy paint. The steel tube below ground level will be painted with three coats of epoxy paints. The design, painting and lettering shall be done as per approved drawing
Providing & fixing of Typical Maintenanace information board consisting of Aluminium Composite Material (ACM), 4mm thick face to be fully covered with high intensity prismetic sheeting type-4 class A/B material specification as per clause 1701.3.7. ACM sheets shall be of size 900mmX1500mm each welded over welded MS flat iron frame of 50mm x 6mm size on back on edges. The flat iron frame of the bottom plate will be welded to 1 no. 75mm x 75mm x 6mm Square tube post. The steel tube post will be embedded in cement concrete M15 grade of 600mm x 600mm x 750mm below ground level. The height of lowermost part of the bottom plate will be 650 mm from normal ground level. The lettering and border etc. of ACM sheets on top & bottom shall be as per clause 1701.4.6 messages/borders. All the sections of frame and posts will be painted with primer and two coats of epoxy paint. The steel tube below ground level will be painted with three coats of epoxy paints. The design, painting and lettering shall be done as per approved drawing
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflecProviding and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications.torising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes.
Cross Drainage Works Maintenance of Hume pipe Culvert by way of Clearing, Cleaning, Erosion repair, repairs to cracks, parapet wall and protection work as per drawing and technical specification Clause 1908
White washing two coats on parapet walls and tree trunks including preparation of surface by cleaning scraping etc. as per technical specifications Clause 1915.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 10.38 MB
Tendernotice_2.pdf
PDF • 8.85 MB
Tendernotice_3.pdf
PDF • 0.36 MB
Tendernotice_4.pdf
PDF • 0.13 MB
Tendernotice_5.pdf
PDF • 2.15 MB
Tendernotice_6.pdf
PDF • 0.21 MB
Tendernotice_7.pdf
PDF • 0.22 MB
BOQ_227936.xls
BOQ • 0.27 MB
Extension_Bid_submission_date.pdf
PDF • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .