| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 3RD FLOOR PLOT NO 59 SY NO 41 AARADHYA GRANDEUR KAVURI HILLS MADHAPUR HYDERABAD TELANGANA 500033 | HYDERABAD | TELANGANA | 500033 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical UNIT NO 805 THE SUMMIT BUSINESS BAY BY OMKAR OPP PVR CINEMAS BESIDE WEH METRO STATION ANDHERI EAST MUMBAI MAHARASHTRA 400093 | MUMBAI SUBURBAN | MAHARASHTRA | 400093 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical 01 BUILDING NO 69 MADHAV TOWER CO HOU SOC LTD SHANTI PARK MIRA ROAD E | MIRA ROAD | MAHARASHTRA | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical OFFICE NO 98 K K MARKET 2ND FLOOR G WING PUNE SATARA ROAD DHANKAWADI PUNE MAHARASHTRA 411043 | PUNE | MAHARASHTRA | 411043 | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical 129 ANDHERI INDUSTRIAL ESTATE OFF VEERA DESAI ROAD ANDHERI WEST MUMBAI MUMBAI MAHARASHTRA 400053 | MUMBAI SUBURBAN | MAHARASHTRA | 400053 | Admitted-Fee/PreQual/Technical |
Tender Value
₹2.7 Cr
EMD Value
₹5.4 L
Closing Date
25 Jun 2026, 3:00 pmClosed
Chief Engineer (ESG)
Chief Engineer (ESG) DCSEM, DAE, V.S. Bhavan, Anushaktinagar, Mumbai-94
Providing Additional CCTV cameras, including Ethernet switches and associated works for video surveillance system at Anushaktinagar, Mumbai-400094
2026_DCSEM_908754_1
DCSEM/CQD/QSC/ AN/Add-CCTV/26-27/NIT-01, Dt.08/05/2026
Open Tender
Surveillance Equipments
Item Rate
240 days
Anushaktinagar, Mumbai
Please refer Tender documents
8 documents required · 8 mandatory
₹0
₹5.4 L
4 Jun 2026
15 May 2026
30 Jun 2026
15 May 2026
25 Jun 2026
15 May 2026
15 May 2026 - 22 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, installation, testing and commisioning of following IP based video surveilance CCTV cameras fixed on pole/wall/ceiling etc with all recommended mounting hardware & accessories etc, all as per technical specification, scope of work, pre bid clarification & including providing and loading device top up licenses of Milestone corporate VMS with 3 year care pack all as per requirement to acheive intended functions and as per instruction of Engineer in charge. Note: 1. Scope includes inegration of new devices and licences with existing Video surviellance system. 2. Existing license details will be provided after award of work. 3. All type tags, cable dressing and termination of all cable is in the scope of agency | |||||
| 0.0 | IP bullet IR outdoor camera 2MP, 50 mtr IR | 175 | each | - | - |
| 0.9 | Dome Indoor Camera | 19 | each | - | - |
| 0.0 | Panaromic outdoor Camera | 17 | each | - | - |
| 0.9 | PTZ IP day/night camera with POE Injector (25W) | 3 | each | - | - |
| 2Supply, installation, testing & commissioning of Mannaged Switches with SMPS and All accesseries etc.all as per technical specification, scope of work | |||||
| 0.0 | Switch industrial Grade(Layer 2): Supply, installation, testing & commissioning of Layer 2 managed industrial switch 8 X 10/100/1000 Tx, POE/POE++ with Minimum 2 nos.or higher gigabit copper & SFP combo ports conforming to following features: 5.6 Gbps Switching capacity, Supports 10/100/1000 Mbps SFPs, Up to 8K MAC address table, Redundant power inputs, IP-30 Metal Case, Support X-Ring function, SNMP v1/v2c/v3, Web, Telnet, CLI Management TFTP firmware update, system configure restore and backup. Provides standards-based IEEE 802.3af. Power over Ethernet - 8 ports of class 3 powered devices at 15.4 watts. Alternative A mode. Ingress Packet Filter and Egress Packet Limit, all as per instruction of Engineer in charge. Scope includes supply of 2 nos. SMPS, SFP modules 2 nos, and all copper port fully loaded & all as per technical specification, scope of work.
Note: 1. Better switch configuration is acceptable.
2. Switch to be Din rail mountable.
3.Dual SMPS should be compatible with switches and shall be pre-approved before procurement.
4. Configuration of Switches and intigration with Existing Backbone Ofc netwrok In the scope of agency | 30 | each | - | - |
| 0.0 | Layer 2 Switch : 4 port manageable fully Loaded LX modules, Layer 2 Ethernet switches with minimum 20, 10/100/1000 base T ports with PoE and minimum 4 nos. Gigabit uplink LX ports. The switching engine shall have a switching speed of at least 48 Gbps. each..
Note: 1. Details all as per technical specification, scope of work.
2. Better switch configuration is acceptable.
3. Configuration of Switches and intigration with Existing Backbone Ofc netwrok In the scope of agency | 5 | each | - | - |
| 0.9 | Layer 3 Switch :28 port manageable fully loaded with LX modules, layer 3 Ethernet Switch with 24 ports 10/100/1000 base LX and 4 numbers of 10000 base LX ports to support single mode fibre, with redundant power supply in hot standby mode. The switching engine (Backplane) should have a switching speed of at least 128 Gbps.
Note: 1.Details all as per technical specification, scope of work.
2. Better switch configuration is acceptable.
3. Configuration of Switches and intigration with Existing Backbone Ofc netwrok In the scope of agency | 5 | each | - | - |
| 3 | Outdoor Junction Box: Supply, installation, testing & commissioning of out door junction Box (wall/pole mounted) all as per specification and scope of work & as per instruction of engineer in charge.
Note:1. Every junction shall have a suitable chamber to facilitate future cable pulling.
2. The scope of the agency includes cable dressing, installation of nut bolts and cable ties, earthing connections of the junction box (JB) using 8 SWG GI wire, and construction of a brick chamber of suitable size—preferably 400 mm (L) × 400 mm (W) × 300 mm (D)—with pipe entry arrangements. The chamber shall be filled with sand after placing the cable loop inside.
3. Details regarding installation, cable entry chambers, and earthing are provided in the scope of work
4.The outdoor junction box should be suitable for installing a Layer 2 switch,2 Nos. SMPS a 600VA UPS, a 6A MCB& spare connectors, a fibre splice box/LIU, an inspection light (6-watt LED) with a control switch, and a spike guard inside the junction box. The junction boxes shall be pole-mounted | 25 | each | - | - |
stage.html
html • 0.03 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.93 MB
Technical_datasheet.xls
Tender Documents • 0.11 MB
UpdatedDetailedNIT.pdf
Tender Documents • 0.92 MB
UpdatedTechnicalBid.pdf
Tender Documents • 2.53 MB
BOQ_955119.xls
BOQ • 0.31 MB
CORRIGENDUM-2.pdf
PDF • 0.65 MB
Corrigendum-1.pdf
PDF • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .