| 1 | L1₹31.1 LAccepted-AOC 601 6TH FLOOR MANGOOR VALLEY NEAR GURUDWARA MANGOOR HILLL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | ₹31.1 L Quoted ₹31.6 L | L1 | Accepted-AOC LOWEST TENDERER |
| 2 | L2₹33.5 L+₹1.9 L (6.07%)Rejected-Finance | ₹33.5 L+₹1.9 L (6.07%) | L2 | Rejected-Finance Other than lowest tenderer |
| 3 | L3₹35.8 L+₹4.3 L (13.5%)Rejected-Finance | ₹35.8 L+₹4.3 L (13.5%) | L3 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹37.6 L
EMD Value
₹75,260
Closing Date
15 Apr 2025, 6:00 pmClosed
GE GOMANTAK
GE Gomantak Vasco Da Gama Pin 403802
Special repairs replacement of aluminium wiring with copper wiring electrical panel and allied services in store houses at MO Goa under GE Gomantak Vasco
2025_MES_701613_1
8709/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
VASCO DA GAMA
As per tender documents
8 documents required · 8 mandatory
₹500
GE GOMANTAK
₹75,260
Yes
14 May 2025
17 Mar 2025
17 Apr 2025
17 Mar 2025
15 Apr 2025
1 Apr 2025
Amount
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. to match the existing complete all as specified and directed. NOTE: Credit for this items shall be made as per conditions separately.
M&L for point wiring complete for one light/ fan/ exhaust fan point controlled by one, one way 5/6 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20 mm dia 'medium grade' PVC conduit ISI marked concealed in wall and fittings and modular metal flush box, modular white cover plate with frame, blanking plate and making good to the disturbed surfaces to match the existing complete all as specified and directed including 1.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including making good disturbed surface to match the existing surface complete all as specified and directed. Note- (i) Rates include the cost of blanking plate, modular plate, modular boxes and covers of suitable modules as required at site. (ii) Modular box, plate and cover shall be of same make as of switch//socket/regulator.
All as per item No. 2 above but for one 5 pin 5/6 Amp socket outlet point on same board
All as per item No. 2 above but for one 5 pin 5/6 Amp socket outlet point on an independent board.
All as per Item No 2 above but for one 6 pin 15/16 amps socket outlet point on an independent board with FRLS cables of size 4 Sqmm and green colour earth cable of size 4 Sqmm.
S&F modular type switch one way 6 Amps, 230 Volt, 1 Module complete all as specified and directed.
S&F modular type switch one way 16 Amps, 230 Volt, 1 Module complete all as specified and directed.
S&F modular type socket one way 6 Amps, 2/3 pin, 230 Volt, 2 Module complete all as specified and directed.
S&F modular type socket one way 6/16 Amps, 2/3 pin, 230 Volt, 2 Module complete all as specified and directed.
S&F ceiling rose, two or three terminal, surface bakelite 65 x 50 mm complete all as specified and directed.
S&F modular type fan regulator, electronic step type, 120 W, 2 Module complete all as specified and directed.
S&F brushless direct current (BLDC) ceiling fan 1400 mm sweep with service value 6.00 BEE, 5 star rating complete with blades and other accessories, single phase, 230 V including 1 m long down rod and making connection with sheathed 3 core cable of size 0.75 Sqmm flexible copper conductor wire complete all as specified and directed. Make : Havells cat No- FHCNF5SWHT56/Orient model Hector 500/ Bajaj Model- ENERGOS 28(SKU Code 251100EE)
S&F in replacement existing U/S light fitting with LED tube light fitting surface and wall mounted batten Aluminium body with 22/20 watts LED having minimum 100 lumens/watts and with integrated electronic driver complete all as specified and directed. Make: Philips cat No-BN021CLED22S PSU CW GR/ Crompton cat no-CCS-103-20-65-SL-DP-NWH/ Halonix HLB-03-20-CW-AL-SQ.
S&F in replacement existing U/S light fitting with Recess mounting LED fittings 36 watts, 600 mm x 600 mm (2ft x 2ft), 6500 K, suitable for modular/ POP/ Gypsum ceiling, luminaire with white powder coated CRCA housing with LEDs. seamless front frame with fat white high transmission acrylic cover 230V, complete in all respect & accessories internally prewired including connecting up with twin core copper twisted flexible copper conductor cable complete all as specified and directed. Make: Havells cat No-VENUSNEO2X2PLR36WLED865G2/ Philips cat No-RC380B LED36S-6500 G5 L60W60 PSU OD SG / Halonix HLFPR22-11-36-CW-37mm-WC.
S&F in replacement existing U/S Highbay light with LED 100 watt indoor high bay hangng light fitting with integrated electrnic driver and hanging cable, steel rope, hanging hooks complete all as specified and directed. Make:Philips cat No-BY225P LED100S CW NB PSU FG GR V1 / Havells cat No-GAZELLAHBP100WLED857PBOTG/ Shakti cat no- SZHHAMX100.
S&F wall mounted fan 400 mm sweep (air circulating), single phase, 230 V complete all as specified and directed. Make : Bajaj cat no-Esteem400mm(SKU code 250542)/Havells cat no-Accelero HS grey(FHWACHSWGR16) /Orient 44 Crystal white
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection single pole and neutral 240 volts, 16 way, including suitable size copper bus bar and metal door, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-54 protection TPN, 415 Volts, 8 way, Vertical type, including suitable size copper bus bar and metal door, epoxy powder coated, factory made complete without MCB/MCCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
S&F in replacement sheet metal enclosures, single pole and neutral with a two pin and earth plug and socket, plug top and one single pole MCB 20 Amps, C series 240 V complete all as specified and directed.
S&F in replacement MCB single pole 240 volts, 'C' curve of rating from 16 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in replacement MCB single pole 240 volts, 'C' curve of rating 40 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in replacement MCB SPN 240 volts, 'C' curve of rating 63 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in replacement MCCB 160 Amps 415 volts, 4 pole, 36 KA breaking capacity with thermal magnetic setting suitable for VTPN including providing suitable size aluminium lugs, spreaders complete all as specified and directed.
S&F in repair sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 2.5 Sqmm nominal cross sectional area and one run of 2.5 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 25 mm PVC conduit and fittings fixed on wall/ roof/ floors/ ceiling etc. including cutting chases to walls for laying conduit wherever required and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire, one run of earth wire and one run of PVC conduit
S&F sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 Sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 32 mm PVC conduit and fittings fixed on wall/ roof/ floors/ ceiling etc. including cutting chases to walls for laying conduit wherever required and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire, one run of earth wire and one run of PVC conduit
S&F in repair sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 10 Sqmm nominal cross sectional area and one run of 10 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 32 mm PVC conduit and fittings fixed on wall/ roof/ floors/ ceiling etc. including cutting chases to walls for laying conduit wherever required and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire, one run of earth wire and one run of PVC conduit
S&F in replacement exhaust fan (Metal body) of 300 mm sweep, AC single phase 230/240 volts, 1400 RPM, heavy duty complete including making electric connection with PVC insulated three core 1.5 Sqmm copper cable from ceiling rose to exhaust fan, making hole in wall of suitable size, grouting anchor bolts/fastners and making good to disturbed surfaces to match the existing complete all as specified and directed. NOTE:- Old exhaust fan will be deposited to MES store yard. Make : Orient Ind heavy duty 1400RPM/ Havells Turbo force 1P(FHEHDSPDB120) /Bajaj Supreme plus Ind fan
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in hard/dense soil for foundation, etc. or for laying of pipe line/ cable etc. n exc 10 sqm on plan and getting out complete all as specified and as directed.
Excavation in trenches in soft/disintegrated rock, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for laying of pipe line/ cable etc. n exc 10 sqm on plan and getting out complete all as specified and as directed.
Returning filling in including spreading watering and well raming in layer excedding 25 cm each in any type of soil/rock complete all as specified and directed.
Removing excavated material (Soils/rock) to a distance not exceeding 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 16 Sqmm 4 core laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 70 Sqmm 3.5 core laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 150 Sqmm 3.5 core laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
M&L for GI tubing medium grade 80 mm bore for passing through cables laid under the floor, along the wall or along the pole including taking down existing pipe complete all as specified and directed .
Supply & laying double walled corrugated (DWC) HDPE full rounded pipe conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 75 mm inner dia and 90 mm outer dia complete all as directed.
M&L taking out old earthing and providing new earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron strip 25 x 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl. excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing complete all as specified an directed. Note:- The unit rate includes the cost of GI pipe medium grade for protection of earth wire and earth strip upto 7.5 M.
Supply and fixing in replacement of existing old un-serviceable Earth continuity conductor of size 25 x 4 mm GI strip fixed to wall and batton or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other situation for loop earthing etc. complete all as specified and directed.
Cutting the existing road/ PCC/RCC/Hard standing for passing pipe/ cable and making good the disturbed surfaces by using cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in mass concrete complete all as specified exists complete all as specified.
S&F in replacement loop-in-loop out fuse junction (SMC) box of internal dimension 250 x 250 x 150 mm made out of FRP sheet and locking screw fitted with and incl 0.5 Amps MCB - 1 No, 20 Amps rated 4 way connectors for 3 phase and neutral incoming/ out going, mounted in the box, fixing on any type of poles including necessary clamps, suitable glands, Connector, lugs, GI nut and bolts complete all as specified and directed. Make : Sintex/ Hensel/National
MS&F in replacement of LED 90 W street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separately including driver compartment with IP66 protection including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 1.5 Sqmm complete all as specified and directed. Make- Shakti Cat no: SZPSLPM090/ Havells cat no: ENDURAOMINI PLUSSL90WLED757SASYTOPC/ Halonix Cat no: HLSLD-01-90-CWDL-R.
S&F in replacement of LED 120 W Flood light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separately including driver compartment with IP66 protection including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm complete all as specified and directed. Make- Halonix cat no: HLFLD-ML25-120-CWL-R/Havells Cat no: JETAIRISFL120WLED757APWBLTG / Shakti Cat no- SZCFLPH120.
S and G Constructions (BID ID -3282049)
Susheel Enterprises (BID ID -3277406)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .