| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹13.2 LAccepted-AOC 1 3 37 CP CHAMBERS 2ND FLOOR STREET NO 5 HABSIGUADA HYDERABAD 500 007 | HYDERABAD | HYDERABAD | TELANGANA | 500007 | L-1 | Accepted-AOC MET THE ELIGIBILITY CRITERIA AND PRICE IS OK | |
| 2 | Rejected-Technical 71 1 1ST FLOOR SHIVAJI MARG NEW DELHI 110015 | NEW DELHI | NEW DELHI | DELHI | 110015 | - | Rejected-Technical Not met the eligibility criteria as per NIT | |
| 3 | Rejected-Technical 9 5 MICRO INSTRUMENT CO DURGA NAGAR AMBALA CANTT HARYANA 133001 INDIA | AMBALA | HARYANA | 133001 | - | Rejected-Technical Not met the eligibility criteria as per NIT |
Tender Value
₹15 L
EMD Value
₹15,000
Closing Date
22 Apr 2019, 3:00 pmClosed
ZONAL HEAD (NORTH)
HSCL CORE 4 , SECOND FLOOR SCOPE MINAR LAXMINAGAR DELHI
Supply, Installation, Testing, Commissioning and Handing over of Medical equipments for 1st Renewal for Medical College Churu Rajasthan
2019_HSCL_455500_1
HSCL/ZH/ND/CHURU/E-56/ 1st Renewal/2019/e-120
Open Tender
Civil Works
Item Rate
30 days
CHURU
as per tender documents
7 documents required · 7 mandatory
₹3,540
HINDUSTAN STEELWORKS CONSTRUCTION LIMITED
₹15,000
Yes
HSCL NEW DELHI
30 Jul 2020
13 Mar 2019
23 Apr 2019
13 Mar 2019
22 Apr 2019
13 Mar 2019
13 Mar 2019 - 4 Apr 2019
18 Mar 2019
Microbiology Hot air oven & Incubator
Hot air oven - Should have a temperature range of surrounding plus 10 2 degrees to 320 20 degree Should have advance preheating system The exhaust flap shall be controlled by Electromechanical control Chamber should be of stainless steel Should work on convection mode which is natural The Approximate volume is around 110 Ltr Should have lcd display and system controller. Should have USB port for recording data Should have 24 point temperature calibration Should have Temp Uniformity at 150 degree : 20.05 K Should have Temp fluctuation at 150 degree : 0.40.005 K The Recovery time after 30 second door opening at 150 degree shall be 18 to 22 min. Demonstration of equipment may be asked prior to opening of financial bid It should have class 2 safety device. European CE or USFDA certified and capable of validation as per international standards Electrical safety conforms to standards for electrical safety IEC-60601 / IS- 13450
INCUBATORS. - Should have a temperature range of surrounding plus 5 2 degrees to 100 10 degree Should have advance preheating sytem The exhaust flap shall be controlled by Electromechanical control Should have class 3.1 safety device. Chamber should be of stainless steel Should work on convection mode which is natural Approximately 110 Ltr Should have lcd display and system controller. USB port for recording data Should have full size inner glass door 24 point temperature calibration Temp Uniformity at 37 degree : 0.40.05 K Temp fluctuation at 37 degree : 0.10.005 K Time to heat up to 37 degree 57 2 min. Demonstration of equipment may be asked prior to opening of financial bid European CE or USFDA certified and capable of validation as per international standards. Conforms to standards for electrical safety IEC-60601 / IS- 13450 Shall be supplied with one Air Conditioner of 2 tonne
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .