| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹14.0 L+₹10,067.76 (0.72%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M.B. Enterprises L1 | A.S.ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.01 | Disconnecting of HT supply from main HT panel after proper switching off 11KV VCB discharging the supply. Complete drain out of transformer oil from transformer to empty oil drum by oil machine, dismantling of conservator tank all protection relays cable end boxes vent pipes and other items as required. | 2 | Jobs | 49,860 ₹58,834.8 Lowest | 50,400 ₹59,472 |
| 1.02 | Cleaning of transformer oil tank and removing of sludge settled in the bottom with the help of vacuum pressure cleaning machine thoroughly, cleaning of core and winding of transformer with hot oil and proper safety precaution to prevent the winding damage as required, cutting of old overheated insulation of winding and re-insulation of weak point with the help of Hf insulation material and proper taping etc. | 2 | Jobs | 1,54,800 ₹1,82,664 Lowest | 1,56,600 ₹1,84,788 |
| 1.03 | Cleaning of winding with DC 2-26 | 300 | Nos. | 92,880 ₹1,09,598.4 Lowest | 94,500 ₹1,11,510 |
| 1.04 | Replacement of top cover gasket vertical vent gasket & missing hardware to stop the oil leakage. | 2 | Jobs | 52,380 ₹61,808.4 Lowest | 52,992 ₹62,530.56 |
| 1.05 | Replacement of salica gel. | 2 | Jobs | 5,130 ₹6,053.4 Lowest | 5,220 ₹6,159.6 |
| 1.06 | Repairing of tape changer | 1 | Jobs | 29,430 ₹34,727.4 Lowest | 29,520 ₹34,833.6 |
| 1.07 | Repairing of 11 Copper boit and Pam, remettaling and finishing the same as per original shape and size. | 8 | Jobs | 1,78,560 ₹2,10,700.8 Lowest | 1,80,000 ₹2,12,400 |
| 1.08 | Checking & matching of control wiring of all protection relays and calibration of bucchlaz relay and protection relays testing the same. | 2 | Jobs | 31,680 ₹37,382.4 Lowest | 32,400 ₹38,232 |
| 1.09 | Complete assembling of transformer cleaning of complete transformer tightening of all connection of incoming and out going side and testing & cable of both sides with HI pot machine. | 2 | Jobs | 58,860 ₹69,454.8 Lowest | 59,040 ₹69,667.2 |
| 1.10 | P/Fixing of winding protection pad. | 2 | Jobs | 36,900 ₹43,542 Lowest | 37,080 ₹43,754.4 |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
27 Oct 2025, 11:15 amClosed
EE ENM M VII
DELHI JAL BOARD MU BLOCK PITAMPURA DELHI-34
Servicing dehydration of 2000KVA Bharat Bijlee make 02 Nos transformer at Lawrance Road BPS in AC 17
2025_DJB_280005_23
NIT No. 21(2025-26)M-VII
Open Tender
Miscellaneous Works
Item Rate
60 days
EE ENM M VII
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No. 50448339804
₹28,000
Yes
18 Nov 2025
18 Oct 2025
27 Oct 2025
18 Oct 2025
27 Oct 2025
18 Oct 2025
Disconnecting of HT supply from main HT panel after proper switching off 11KV VCB discharging the supply. Complete drain out of transformer oil from transformer to empty oil drum by oil machine, dismantling of conservator tank all protection relays cable end boxes vent pipes and other items as required.
Cleaning of transformer oil tank and removing of sludge settled in the bottom with the help of vacuum pressure cleaning machine thoroughly, cleaning of core and winding of transformer with hot oil and proper safety precaution to prevent the winding damage as required, cutting of old overheated insulation of winding and re-insulation of weak point with the help of Hf insulation material and proper taping etc.
Cleaning of winding with DC 2-26
Replacement of top cover gasket vertical vent gasket & missing hardware to stop the oil leakage.
Replacement of salica gel.
Repairing of tape changer
Repairing of 11 Copper boit and Pam, remettaling and finishing the same as per original shape and size.
Checking & matching of control wiring of all protection relays and calibration of bucchlaz relay and protection relays testing the same.
Complete assembling of transformer cleaning of complete transformer tightening of all connection of incoming and out going side and testing & cable of both sides with HI pot machine.
P/Fixing of winding protection pad.
Repair of cooling fins, replacement of cooling fins gasket and oil seal for stopping the leakage
Filling of T/oil to up to top up level as required to make Savita/ Power
Dehydration & filtration of complete transformer oil and checking the die electric strength up to 50 KV at site as required.
Complete cleaning and chemically washing of oily and muddy transformer body and painting of transformer with enamel pain
Insulating the bus bar with epoxy paint
A.S.ENTERPRISES (BID ID -1633451)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.58 MB
BOQ_369603.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .