Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC | L1 | Accepted-AOC FULLFILL THE CONDOITION OF CA | |
| 2 | L2₹28.0 L+₹80,632 (2.96%)Rejected-Finance | L2 | Rejected-Finance Rejected being not the lowest | |
| 3 | L3₹28.3 L+₹1.1 L (4.05%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L3 | Rejected-Finance Rejected being not the lowest |
Tender Value
₹27.3 L
EMD Value
₹54,640
Closing Date
13 Mar 2020, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I)(CG) Military Engineer services Second Floor CG DHQ No 5(TN) No 4 and 4 A Clive Battery complex Rajaji Salai Chennai 600001
Provision of RO plant (Sky water from Air) in building Nos P 3 and P 5 officers married accommodation at Thalakancherry and DHQ 5 area under GE (I) (CG) Chennai
2020_MES_327108_1
8664A/GE(I)(CG)
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer (I)(CG) Chennai
All as per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹54,640
Yes
23 Nov 2020
20 Feb 2020
17 Mar 2020
20 Feb 2020
13 Mar 2020
27 Feb 2020
Amount
Supply,install ,test and commission Sky water Atmospheric air liquidfying water generator of 100 LPD in 24 hours cycle with water level sensor ,RH indicator,Low RH cutoff,HP/LP cut off and multi level filtration unit as per manufacturers instructions comprising of the following specifications: (a) Ambient temperature for rated output: 90 degree F and relative humidity 80% . (b) Working temperature :- 20 degree to 45 degree centigrade ..
(c) Supply Voltage/Frequency/Phase : 220 Volts/50 Hz/ Single phase. (d) Normal power consumption : 2.00 KW/Hour. (e) Peak power consumption : 2 .00 KW/Hour. (f) Water storage tank :LDPE Food grade plastic inbuilt of 60 litres capacity. (g) Inbuilt water treatment features (h) Size : 79 cmx 73 cmx 140 cm . (i) Weight : 145 kg. (j) Filtration : Multi level filtration. (k) Refrigerant :R407C
(j) Noise Level : dBA Less than 65 DB. (k) 5 KVA Voltage stabilizer , Input supply : 140 to 240 V , Output supply : 220 V Make : V Guard// Everest/ . Make :M/S MAITHRI AQUATECH Pvt.Ltd , MODEL NO: MEGHDOOT-100 LPD. Note : The rate quoted by the contractor shall be inclusive of necessary power supply from tapping point as per manufacturers instructions .
Supply and fix Wiring for Circuit / Submain Wiring of FRLS cable size 2 x 2.50 sq.mm along with earth wire of size 1 x 2.50 sq.mm, Single Core, PVC insulated copper Cable in surface/Recessed non metallic rigid PVC Conduit of size 20 mm dia complete all as specified and as directed. Note: (i) Three runs of 2.50 Sqmm copper cable and one run of PVC conduit shall measured as one unit. (ii) Make of PVC copper cable : Finolex/Asian/Polycab (iii) PVC conduit :Avon plast/Retro plast/ Kon seal
Supply and fix switch socket outlet 15 amps capacity ,230 Volts, SP Make: Anchor / Legrand/ L&T
Supply,install ,test and commission Sky water Atmospheric air liquidyfying water generator of 30 LPD in 24 hourscycle comprising of the following specifications :- (a) Ambient temperature for rated output: :90 F and relative humidity 80% . (b) Working temperature :- 20 degree to 45 degree centigrade. (C) Supply Voltage/Frequency/Phase : 220 Volts/50 Hz/ Single phase. (d) Normal power consumption : 0.70 KW/Hour. (e) Peak power consumption : 0.70 KW/Hour. (f) Water storage tank :Food grade plastic LDPE inbuilt of 12.50 litres capacity. (g) Inbuilt water treatment features (h) Size : 46cmx46 cmx 122 cm .
(j) Weight : 55 kg (k) Noise Level : Less than 65 DB. (l) 2 KVA Voltage stabilizer , Input supply : 140 to 240 V , Output supply : 220 V Make : V Guard// Everest/Microtek . Make : M/S MAITHRI AQUATECH Pvt.Ltd , MODEL NO: MEGHDOOT-30LPD. Note : (i) MS stand for fixing generator shall be measured and paid under relevant item. (ii)The rate quoted by the contractor shall be inclusive of necessary power supply from tapping point as per manufacturers instructions .
Supply and install powder coated(minium 50micron) MS stand of size 450mm X 460mm X 450mm with MS angle iron 40mm X 25mm X 3mm thick box type welded with MS square plate 50cm X 60cm X 5mm as base on four legs at bottom welded and supplied as per manufacturers instructions.
Note: The sky water generator supplied and installed by the contractor shall be maintained for two years .Regular/routine maintenance including repair/renewal of spares shall be carried out by the contractor as per manufacturers instructions and through authorised service dealer of manufacturer.The rate quoted by the contractor for item Nos.1 & 4 of BOQ shall be inclusive of the above provisions.No extra cost on this account is admissible.Accordingly contractor has to execute the subject contract within 06 months from the date of commencement of work (i.e)Phase-I . 70% of the rate quoted by the contractor for supply and installation of sky water generator shall be paid to the contractor on satisfactory completion of Phase-I.Maintenance and repair of sky water generator shall commence from the next date of completion of Phase-I and further run upto 02 Years (i.e) Phase-II . 15% of rate quoted for item Nos 1 & 4 of BOQ shall be paid to the contractor for each year of maintenance of sky water generator carried out by them.Final bill will be paid after satisfactory completion of maintenance/repair of sky water generator by the contractor.
Anand electrical
EVEREST ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .