Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹28.9 L+₹10,081 (0.35%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹33.1 L+₹4.4 L (15.2%)Rejected-Finance FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹33.4 L+₹4.6 L (16.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹37.9 L+₹9.2 L (31.9%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
17 Sept 2022, 6:00 pmClosed
GE NORTH PUNE
Garrison Engineer North General Cariappa Marg Camp Pune 411001
GE(N) P/T- 46 OF 2022-2023 REP/REPLAC AND MAINT TO EXISTING UNSV INTENAL WIRING TO OTM ACCN AT HQ 41 ARTY DIV101 TABN 641EME HQ RTG752 TPT, COMMD MT CAMP APS JR WG, STNJCOS MESS DSC PL, GURUDWARA RD, SHANTI EAST AREA OF AGE E/M UNDER GE (N)PUNE
2022_MES_546581_1
GE (N) P/TOKEN- 46 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
GE NORTH PUNE
Refer tender documents.
8 documents required · 8 mandatory
₹500
GE NORTH PUNE
₹78,000
Yes
10 Oct 2022
20 Aug 2022
19 Sept 2022
20 Aug 2022
17 Sept 2022
5 Sept 2022
20 Aug 2022 - 26 Aug 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fitting fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets,LED fittings etc. removing materials to store for keeping in safe custody to reuse or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH Cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH Cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :-
(a) One light / fan controlled by one switch one way.
(b) One light point controlled by two 2 way switch.
(c) Socket outlet 05 Amp on same board.
(d) Socket outlet 05 Amp on independent board.
(e) One bell / buzzer point controlled by one bell push
All as per item No : 02 point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH Cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with GI sunken /surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches, or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH Cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
(a) One ligh/Fant point controlled by one No one way switch
(b) One three pin 5 Amps socket outlet point controlled by one No one way switch on same board
(c) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
(d) One bell / buzzer point controlled by one bell push
All as per item No 4 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board.
M & L in replacement for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH Cable with multistranded copper conductor of size 4.0 Sq mm nominal area and drawn through PVC non metallic rigid PVC casing caping and its accessories including one run of PVC insulated 2.5 Sq mm (nominal area) multistranded copper conductor FRLSH Cable as earth wire and connected from DB to DB/ main board complete all as specified and as directed.(Note- Two runs of 4.0 Sqmm main cable, one run of 2.5Sqmm earth conductor and one run of PVC conduit will be measured as one unit)
All as per item No 6 but Submain wiring with 2 runs of 6 Sqmm size main cable and one run of 4 Sqmm size earth continuity conductor.
All as per item No 6 but Submain wiring with 4 runs of 6 Sqmm size main cable and one run of 4 Sqmm size earth continuity conductor.
All as per item No 6 but Submain wiring with 4 runs of 10 Sqmm size main cable and two run of 10 Sqmm size earth continuity conductor.
NOTE:- For Sr no 2 to 9 , Wires test certificates is required from OEM before commencement of contract
S&F modular switch 01 way 6 Amp , 01 module ISI marked complete
S&F modular switch 02 way 6 Amp , 01 module ISI marked complete
S&F modular switch 01 way 16 Amp , 01 module ISI marked complete
M&L for Modular bell push 6 amp 230 volt 50 hz AC supply one way, complete all as specified
S&F modular socket 6 Amp , 2 module ISI marked complete
S&F modular socket 6 / 16 Amp , 02 in 01 , 02 module ISI marked complete
S&F for modular step fan regulator 120 watt 2 module suitable for 230 Volt 50 Hz supply all as specified
Supply & fix CALL Bell ISI marked complete
S&F ceiling rose surface Bakelite 3 terminals 230V 50 Hz ISI marked.
S&F for Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fitting completes all as specified.
S&F for Switch piano; flush type single pole one way, and 6 amp complete ISI mark
S&F for Switch Socket combination multipurpose having provision for 2 in 1, 3 pin 5 amp piano flush type complete all as specified (4 Hole Type)
S&F for Switch Socket combination multipurpose having provision for 2 in 1, 3 pin 5/15 amp piano flush type complete all as specified (4 Hole Type)
Supply,installation,testing and commissioning of ceiling mount auto light occupancy, dual technology sensor,adjustable of delay timer, infra red and ultrasonic detection,Dia 8meters IP 20, 3 wire with neutral optimum distance between 2 sensors should be 6 Mtr, stand by consumption 0.8W, fixed directly to a false ceiling with mounting claws (included) or installed in a battibox depth 50 mm all as specified and directed. Note:- All necessary FRLSH copper wires to connect complete lights of office bldg/OR living/Messes etc are deemed to be included in the rates quoted above for motion sensors. Make : Legrand Cat no 048806, SWG 12582DB12 of Siemens, MTN630919 Schneider.
S & F for wall/ceiling mounted 10 watts or more indoor, box type light fitting white/ warm white 02 Feet as per site requirement, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 2' x 10 watts complete all as specified and as directed. Make :- JAQUAR Cat part No LGLZ01X010XN, Philips BN021C LED 12S 6500 PSU GR.
S & F for wall/ceiling mounted LED 20 watts white/warm white as per site requirement with out put of minimum 2000 lumens , box type (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 20 watts complete all as specified and as directed. Make :- Halonix Cat part No HLB-03-20-CW-AL-SQ , Philips BN021C LED 22 S PSUCWGR, Jaquar LGLZUIX022XN.
S & F in replacement for wall mounted 20 watts indoor Inverter batten with opal diffuser, IP 20, with 3 to 4 hrs back up with out put of 2000 lumens , box type light fitting, 230 volts with polycarbonate type body and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 20 watts complete all as specified and as directed. Make :- Halonix Cat part No.HLB-07-20-CW-INV, Havells LHEXACP7FN1W020.
Supply and fix for energy saving new generation 10 watts LED bulk head fitting , 230 volts with connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor from ceiling rose to fitting complete all as specified and as directed. Make :- BAJAJ CAT NO BIBWP 10W/JAQUAR Cat No. LBLK02X010XC/Halonix
Supply & fix in replacment of old unserviceable decorative wall mounted energy saving 03 watt or above LED bedside light fitting flexible and adjustable to any direction with integeral electronic driver complete with all accessories. Cat Part No 48042 of philips black & metallic , Havells model Uneco.
S & F in replacement for Decorative wall mounted luminaire with opal glass with nickle finishing wall lamp with E27 lamp holder with and including LED bulb 10/11 watts complete all as specified and as directed. Make- Jaquar Cat part No - JNL-CHR-WLSL-55004E27 , HALONIX HLWB-05-E27 or its equivalent in Philips.
S & F for recess mounted 2' x 2' square LED panel 36 watts, 596 x 596 x 9mm size, sleek design aluminium housing, polycarbibate diffuser white powder coated finish operating voltage 140 volts - 270 volts, AC, 50 Hz complete all as specified and as directed. Make- Halonix HLFPR22-11-36-CW-37mm, Philips RC383B LED 4000 PSU ODWH PIR, Jaquar LULTUI15 036XC.
S & F for LED down light recess mounted luminare, round/square type 15 watts as per site requirement with efficiency of 1500 lumens per watt, Series of downlighters with low depth round & larger dia, powder coated white finish with drop down PC diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver suitable for office spaces sleek design white finish operating voltage 150 V-270 V AC, 50 Hz all as specified. Make- JAQUAR Cat part No. LNEP01S015XN/LLCN01R01SXN, Halonix HLDLR31-15CW/ HLDLR-S27-15-CW,Philips DN296B LED 15S-6500 PSU WH.
S & F for recess mounted 1' x 1' square LED panel 18 watts, IP 20, sleek design aluminium housing, polycarbibate diffuser white powder coated finish operating voltage 140 volts - 270 volts, AC, 50 Hz complete all as specified and as directed. Make- Halonix HLFPR11-02-18-CW, Jaquar LNEP01S024XN, Phillips SM200C LED115 6500 PSU OD WH.
S & F for LED post top lantern 24/25 watt light fitting New generation, energy saving, environmental friendly, long life aesthetically designed Die cast aluminium housing, frosted PC di user, IP54 with high power LED as light source complete with all accessories fixed on GI pipe 40mm dia complete all as specified and directed. Make : JAQUAR Cat No LGTP01X012XW Bajaj Cat part No BGCTN 25W LED WW or its equavalent in HALONIX
M & L for PCC (1:3:6) type C1(using 20 mm graded stone aggregate ) as in foundation of poles and similar works, filling mass concrete complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge.
M&L for cutting roads for laying of cable/pipe and making good road surface with PCC 1:2:4 type B-1 with 20 mm aggergate stone complete all as specified and directed by Engr-in-Charge
Supply and laying GI tubing , medium grade of 50 mm Dia, with all fittings (all ISI marked) and laid in trenches / under roads / in drains / fixed to poles/wallswith required size flat iron clamp bolts, nuts and washers complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Supply and laying 50mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
Supply, lay, joint, test and commissioning of LT under ground cable 1100 volt grade , XLPE insulated and PVC sheathed heavy duty armoured with aluminium conductor , IS 7098-I Marked, Laid in trenches/ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe including cable glands, lugs jointing material etc complete including taking out old UNSV cable all as specified and directed. cable of the following size.
(a) 25 Sq mm 4 Core
(a) 50 Sq mm 3.5 Core
S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 15 watts or above with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 0.6 to 0.9 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make :- Halonix cat no. HLSLD-09H-15-CWL-R, Havells LHETAXU7PA6S015, Jaquar LPCRSRT25WLC .
S/F LED street light fitting 30 Watt 230V energy efficient & environment friendly type. The fitting should have powder coated, pressure die cast Aluminium housing and heat resistant toughened glass with frame having better optics for uniform distribution complete all as per Make JAQUAR LPCRSRT30WXC ,BAJAJ ENXT P 30L WH PO PC SD Halonix cat no.
Supply & fix in replacement LED 60W Highbay light fitting with relevant IS & IP65 protection complete with all mounting attachements all as specified and directed as per cat part no Tento Nxt B 60L WH NB SD of Bajaj or ILIOSBAYPLUSHBP60WLED857SP90DTOPC OF HAVELLS Or LHBLDUL070XC OF JAQUAR
S&F in replacement for MCB DB TPN 4 way double door sheet metal enclosure for 63 Amps MCB TPN incomer comprising of OEM/manufacturer specified bus bar, 415 Volts, 50 Hz bus bar and neutral link complete including inserting in wall all as specified. MAKE:- LEGRAND/L&T/SCHNEIDER
S&F in replacement for MCCB DB VTPN 4 way double door sheet metal enclosure for 100 Amps 4 pole MCCB (ICS = ICU= 100%) Incomer comprising OEM/manufacturer specified bus bar, 415 Volts, 50 Hz bus bar and neutral link complete including inserting in wall all as specified. MAKE:- LEGRAND/L&T/SCHNEIDER
S&F in replacement for MCCB DB VTPN 8 way double door sheet metal enclosure for 100 Amps 4 pole MCCB Incomer comprising OEM/manufacturer specified bus bar, 415 Volts, 50 Hz bus bar and neutral link complete including inserting in wall all as specified. MAKE:- LEGRAND/L&T/SCHNEIDER
S & F MCCB TPN 415 volts 25 KA suitable for fixing on DB of capacity 100 A (ICS=ICU=100%) with extended terminals complete all as specified. MAKE:-LEGRAND/L&T/SCHNEIDER
S & F for MCB triple pole and neutral 415 Volts, 63 Amps, 10 KA. (ICS=ICU=100%) MAKE:-LEGRAND/L&T/SCHNEIDER
S & F for MCB triple pole and neutral 415 Volts, 32Amps, 10 KA.(ICS=ICU=100%) MAKE:-LEGRAND/L&T/SCHNEIDER
S&F in replacement for MCB DB SPN 04 way double door sheet metal enclosure with OEM specified common bus bar and neutral link compete including inserting in wall all as specified. MAKE:-LEGRAND/L&T/SCHNEIDER
S&F in replacement for MCB DB SPN 08 way double door sheet metal enclosure with OEM specified common bus bar and neutral link compete including inserting in wall all as specified. MAKE:-LEGRAND/L&T/SCHNEIDER
S&F in replacement for MCB DB SPN 12 way double door sheet metal enclosure with OEM specified common bus bar and neutral link compete including inserting in wall all as specified. MAKE:-LEGRAND/L&T/SCHNEIDER
S & F for 'C' curve MCB single pole & neutral 240Volts 32/40 Amps. MAKE:-LEGRAND/L&T/SCHNEIDER
S&F 'C' curve MCB SP 240 volt 6 to 30 Amp MAKE:-LEGRAND/L&T/SCHNEIDER
Supply and fix MCB Protected SRCD box 4 module 25 Amps with surface mounted PVC enclosure SRCD(socket residual current device) single pole with a three pin socket & top complete with 25 Amps MCB single pole. Make: Havells Cat part No DHDTCSN0251020 OR Equivalent Indo Asian/L&T/Legrand
Supply and fix for sheet metal enclosures single pole and neutral with a three pin earth plug and socket complete with one MCB SP 20/ 32Amps complete all as specified and as directed.
S&F in replacement readymade surface mounted/concealed Gang box/ PVC box with modular cover plate and frame all ISI marked suitable for holding modular switch socket & regulators for the following module:-
(a) 3 module
(b) 4 Module
(c) 6 Module
(d) 8 Module
S&F in replacement surface mounted 20A & 10A modular switch Socket combination ( 4 fixing holes ) with PVC box all ISI marked complete all as specified
S&F in replacement 32A DP modular switch W/O fuse with neon indicator ISI marked complete
Material and labour for attending emergent complaints i.e no light, earth leakage, short circuit, neutral break mains/ sub mains/ internal circuits of existing system of main building/ block, making continious electric supply including carrying out minor repairs etc as required to make the system in order/ functional including replacing fuse wire, copper cable, copper thimbles, glands, earthing wire complete all as specified and as directed. Note :- Rate of fuse wire, copper thimbles, glands, earthing wire are deemed to be considered in this item.
Taking down existing cable electrical /fiber/telephone of any type and any description/ size from wall/ roof/floor and refixing the same within PVC conduit pipe or casing capping and making good to the disturbed surfaces to match the existing complete all as specified and directed at site. Note : - Rates of PVC conduit pipe/ casing capping will be measured and paid separately under relavant iterms.
Supply and fix for casing and capping heavy duty, size 20mm with all fittings including removal of old unserviceable one complete all as specified and as directed
S & F for casing and capping size 25 mm for existing wires including removal of old unserviceable one complete all as specified and as directed
Supply and replace for rigit PVC conduit 20mm dia. heavy duty of white/ ivory colour with all accessories and making good the disturbed seurfaces for laying of telephone cable complete including removal old existing unserviceable all as directed
Supply and replace for single core cable PVC insulated and unsheathed multistranded copper conductor of following size from point wiring/Submain wiring including removal old existing unserviceable one complete all as specified and directed.
(a) 1.5 Sq mm
(b) 2.5 Sq mm
(c) 4.0 Sq mm
(d) 6.0 Sq mm
Supply & fix storage type 5 star rated vertical Geyser, single phase , 230 volts , capacity 50 ltr including PVC connection for hot & cold water complete fixed on wall with the help of T head bolt 10 mm dia 100 mm long grouting on wall all as directed by Engr - in - Charge . Make : RACOLD MODEL NO CDR SP 50V/Havells/USHA
Supply & fix storage type 5 star rated vertical Geyser, single phase , 230 volts , capacity 25 ltr including PVC connection for hot & cold water complete fixed on wall with the help of T head bolt 10 mm dia 100 mm long grouting on wall all as directed by Engr - in - Charge . Make : RACOLD /Havells/USHA
Supply and fix for wall mounted fan of size 400 mm sweep BEE. Five star rated with brushless direct current motor (BLDC) →, ISI marked and connecting up including provision of cable from ceiling rose or connector to fan complete all as including removal of old unsv fan and handed over to store yard of AGE E/M (North) complete all as specified and directed. Note : a) Quoted Rate is deemed to inclusive of Stickering/Marking/writing of MES numbers in bottom of ceiling Fan as directed by Engr-in-Charge. Make:- Bajaj MIDEA BW 2200, USHA Pentacool, Havells V3.
Supply and fix ready made outdoor type heavy duty polymer earth pit chamber box of size 300x300x260 mm with provision of earthing strip/ GI pipe entry glands and cover complete all as specified and as directed by Engineer-in-Charge make JEAF techno earthing. (Note sample is kept in GE Ofiice sample room)
M&L for Maintenance Free Grounding Solution set earthing comprising of High tensile low carbon steel rod of 3 Mts length & 17.2 mm dia with 250micron ( average ) molecularly bonded copper on the outer surface along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. Back-fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Make: JEF Technology or equivalant in True power earthings Note:- a) Test certificate from the OEM has to be produced by the contractor for the material used in earthing. b) If the test result obtain from earthing is not less than 3 Ohms then earthing has to be done again at no extra cost. c) Rates for Excavation and earthwork in any type of soil/strata, testing on completion, GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from Electrode is deemed to be included in rate quoted.)
Supplying and fixing in replacement 10Sq mm 2Core, 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC sheathed in service connections one twin core cable flat or circular Make Havells, finolex
Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
PURVA ELECTRICALS AND ENGINEERS
R J ENTERPRISES
Suchit constructions
metro electrical services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .