Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC | ₹1.7 Cr | L1 | Accepted-AOC WORK AWARDED |
| 2 | L2₹1.8 Cr+₹4.0 L (2.34%)Rejected-AOC | ₹1.8 Cr+₹4.0 L (2.34%) | L2 | Rejected-AOC SECOND LOWEST |
| 3 | L3₹1.8 Cr+₹5.7 L (3.32%)Rejected-AOC 2 1068 MALLIGAI STREET EZHIL NAGAR IYER BUNGALOW MADURAI 625014 | MADURAI | TAMIL NADU | 625014 | ₹1.8 Cr+₹5.7 L (3.32%) | L3 | Rejected-AOC THIRD LOWEST |
| Sl No | Description | Qty | Unit | PR & CO L3 | E.SENTHILKUMAR L1 | S.ANBU L2 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls Brick / stone masonry in Cement mortar walls under 3m high. | 59 | Cu.m | 303 ₹17,877 Lowest | 303 ₹17,877 Lowest | 303 ₹17,877 Lowest |
| 2.00 | Dismantling, clearing away and carefully stacking materials useful for re-use for floor finish and dadooing walls in cement mortar with mosaic tiles/ glazed tiles / cuddapah slabs etc., as directed by the departmental officers | 720 | Cu.m | 66 ₹47,520 Lowest | 66 ₹47,520 Lowest | 66 ₹47,520 Lowest |
| 3.00 | Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers. | 132 | Cu.m | 370 ₹48,840 Lowest | 370 ₹48,840 Lowest | 370 ₹48,840 Lowest |
| 4.00Brick work in Cement Mortar 1:5 using best quality Burnt Clay Brick of size 9" x 4 3/8" x 2 3/4" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. | ||||||
| 4.01 | For Superstructure In Ground Floor | 15 | Cu.m | 7,507 ₹1,12,605 Lowest | 7,507 ₹1,12,605 Lowest | 7,507 ₹1,12,605 Lowest |
| 4.02 | For Superstructure In First Floor | 12 | Cu.m | 7,694 ₹92,328 Lowest | 7,694 ₹92,328 Lowest | 7,694 ₹92,328 Lowest |
| 4.03 | For Superstructure In Second Floor | 36 | Cu.m | 7,881 ₹2,83,716 Lowest | 7,881 ₹2,83,716 Lowest | 7,881 ₹2,83,716 Lowest |
| 5.00 | Paving the floor with best quality Double Charged Vitrified Tiles 600 x 600 x 8mm and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) | 760 | Sq.m | 1,800 ₹13,68,000 | 1,570 ₹11,93,200 Lowest | 1,870 ₹14,21,200 |
| 6.00Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers. | ||||||
| 6.01 | Reinforced cement concrete precast slab 50mm thick using 20mm Jelly | 18 | Sq.m | 591 ₹10,638 Lowest | 591 ₹10,638 Lowest | 591 ₹10,638 Lowest |
Tender Value
₹1.7 Cr
EMD Value
₹96,000
Closing Date
2 Apr 2026, 3:00 pmClosed
SUPERINTENDING ENGINEER
The Supdt. Engr. PWD Bldg C and M Circle Vellore
Arrangements made for Strong room, Counting Hall and Security Barricading for General Assembly Election 2026 to Kancheepuram District Assembly Constituency Counting Centre in Anna University College of Engineering at Kancheepuram in Kancheepuram Dist
2026_PWD_675422_1
31/VLR-CLE/25-26-3/24.03.2026
Open Tender
Civil Works - Others
Lump-sum
60 days
KANCHEEPURAM IN KANCHEEPURAM DISTRICT
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹96,000
21 May 2026
1 Apr 2026
2 Apr 2026
1 Apr 2026
2 Apr 2026
1 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls Brick / stone masonry in Cement mortar walls under 3m high. | |||||
| 2Dismantling, clearing away and carefully stacking materials useful for re-use for floor finish and dadooing walls in cement mortar with mosaic tiles/ glazed tiles / cuddapah slabs etc., as directed by the departmental officers | |||||
| 3Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers. | |||||
| 4Brick work in Cement Mortar 1:5 using best quality Burnt Clay Brick of size 9" x 4 3/8" x 2 3/4" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. | |||||
| 4.01 | For Superstructure In Ground Floor | - | Cu.m | - | - |
| 4.02 | For Superstructure In First Floor | - | Cu.m | - | - |
| 4.03 | For Superstructure In Second Floor | - | Cu.m | - | - |
| 5Paving the floor with best quality Double Charged Vitrified Tiles 600 x 600 x 8mm and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) | |||||
| 6Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers. | |||||
| 6.01 | Reinforced cement concrete precast slab 50mm thick using 20mm Jelly | - | Sq.m | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
BOQ_811783.xls
BOQ • 0.41 MB
Documents-Election-Kancheepuram.pdf
Tender Documents • 0.32 MB
General-Condition-Election-Kancheepuram.pdf
Additional Documents • 0.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .