Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | ₹4.7 L Quoted ₹5.1 L | L1 | Accepted-AOC LOWEST BID |
| 2 | L2₹5.2 LRejected-Finance 17 A SUBASH CHANDRA BOSE STREET MELAKARUNKULAM POST PALAYAMKOTTAI TALUK TIRUNELVELI 627 356 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627356 | ₹5.2 L | L2 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | EVEREST ENGINEERING WORKS L1 | M/S VIGNESH POWER SYSTEM L2 |
|---|---|---|---|---|---|
| 1.00 | Taking down carefully unserviceable Ceiling Fan of any size from its position, dismantling blade, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condenser, condenser holder, shackle etc. reassembling after replacement of defective parts including replacement of 3 core 0.75 Sqmm flexible copper cable from ceiling rose to connector, hanging in its position properly complete all as specified and directed.
Note:- Replacement of unserviceable spare parts shall be measured and paid separately under respective items of this schedule here-in-after as supply only. | 400 | Each | 75 ₹30,000 | 150 ₹60,000 |
| 2.00 | Description all as per Sl item No 1 but for exhaust fan of any size | 80 | Each | 60 ₹4,800 | 150 ₹12,000 |
| 3.00 | Description all as per Sl item No 1 but Pedestal fan of any size. | 20 | Each | 100 ₹2,000 | 150 ₹3,000 |
| 4.00 | Supply only ball bearing of existing size suitable for ceiling fan, exhaust fan, fresh air fan, pedestal fan as that of existing defective one complete all as specified and directed. | 390 | Each | 65 ₹25,350 | 120 ₹46,800 |
| 5.00 | Supply only bush bearing of existing size suitable for ceiling fan, exhaust fan, fresh air fan and pedestal fan of complete all as specified and directed. | 60 | Each | 10 ₹600 | 70 ₹4,200 |
| 6.00 | Supply only condenser 2.5 MFD complete all as specified and directed. | 400 | Each | 40 ₹16,000 | 70 ₹28,000 |
| 7.00 | Supply only condenser 4 MFD complete all as specified and directed. | 40 | Each | 55 ₹2,200 | 120 ₹4,800 |
| 8.00 | M&L for cleaning and preparing the surfaces of ceiling fan, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and directed. | 400 | Each | 75 ₹30,000 | 70 ₹28,000 |
| 9.00 | M&L for cleaning and preparing the surfaces of exhaust fan removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and directed. | 80 | Each | 100 ₹8,000 | 70 ₹5,600 |
| 10.00 | Rewinding the stator complete with super enamelled bare copper conductor with the existing size/gauge and number of turns as that of the old one, insulating, varnishing and pre heating for ceiling fan 1200mm/1400mm sweep complete all as specified and directed. | 250 | Each | 700 ₹1.8 L | 550 ₹1.4 L |
Updated dates
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
19 Jan 2026, 6:00 pmClosed
GE NAVY CHENNAI
GE NAVY CHENNAI MILITARY ENGINEER SERVICE FORT SAINT GEORGE, RAJAJI SALAI, CHENNAI -600009
REPAIRS TO CEILING FAN, EXHAUST FAN, PEDESTAL FAN, METERS AND MAINT OF VOLTAGE STABILIZER, SOLAR WATER HEATER AND GEYSERS AT ZONE A UNDER GE (NAVY) CHENNAI
2025_MES_745315_1
8738/E8
Open Tender
Electrical and Maintenance Works
180 days
CHENNAI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE NAVY CHENNAI
₹14,000
Yes
17 Mar 2026
19 Dec 2025
20 Jan 2026
19 Dec 2025
19 Jan 2026
2 Jan 2026
Taking down carefully unserviceable Ceiling Fan of any size from its position, dismantling blade, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condenser, condenser holder, shackle etc. reassembling after replacement of defective parts including replacement of 3 core 0.75 Sqmm flexible copper cable from ceiling rose to connector, hanging in its position properly complete all as specified and directed. Note:- Replacement of unserviceable spare parts shall be measured and paid separately under respective items of this schedule here-in-after as supply only.
Description all as per Sl item No 1 but for exhaust fan of any size
Description all as per Sl item No 1 but Pedestal fan of any size.
Supply only ball bearing of existing size suitable for ceiling fan, exhaust fan, fresh air fan, pedestal fan as that of existing defective one complete all as specified and directed.
Supply only bush bearing of existing size suitable for ceiling fan, exhaust fan, fresh air fan and pedestal fan of complete all as specified and directed.
Supply only condenser 2.5 MFD complete all as specified and directed.
Supply only condenser 4 MFD complete all as specified and directed.
M&L for cleaning and preparing the surfaces of ceiling fan, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and directed.
M&L for cleaning and preparing the surfaces of exhaust fan removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and directed.
Rewinding the stator complete with super enamelled bare copper conductor with the existing size/gauge and number of turns as that of the old one, insulating, varnishing and pre heating for ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
Description all as per Sl No 10.00 here in before but Exhaust fan upto 300mm sweep.
Description all as per Sl No 10.00 here in before but Exhaust fan above 300mm upto 450mm sweep.
Description all as per Sl No 10.00 here in before but Pedestal fan fan upto 300mm sweep.
Removing the damaged and corroded exhaust fan louvers and replace with new louvers of size up to 300mm sweep complete all as specified and directed.
Removing the damaged and corroded exhaust fan louvers and replace with new louvers of size above 300mm and up to 450mm complete all as specified and directed.
Removing the damaged and corroded exhaust fan blades and replace with new blades of size up to 300mm sweep complete all as specified and directed.
Removing the damaged and corroded exhaust fan blades and replace with new blades of size above 300mm and up to 450mm complete all as specified and directed.
Taking down defective storage water heater of any capacity from buildings after disconnecting carefully water and electric connection, opening the bottom cover replacing the defective parts fixing the cover and refixing in original position reconnecting both water and electric connection and testing complete all as specified and directed. Notes :- Replacement of spares will be measured and paid for separately under respective items of the schedule here-in-after as supply only.
Supply only new heating element of capacity 1.5KW with rubber gasket complete all as specified and directed.
Supply only new heating element of capacity 2 KW with rubber gasket complete all as specified and directed.
Supply only thermostat suitable for storage type water heater complete all as specified and directed.
Supply only 3 core 2.5 Sqmm copper conductor cable suitable for geysers of any size complete all as specified and directed.
Supply only Non return valve 15mm dia suitable for geyser complete all as specified and directed.
S&F Metal socket single pole and neutral with two pin and earth socket complete with one single pole MCB 25 Amps complete all as specified and directed.
S&F 3 pin plug top suitable for metal socket of capacity 25 Amps complete all as specified and directed.
M&L for preparing external surfaces of water heater, cleaning and painting with one coat of synthetic enamel paint of white colour of approved make with brush and writing MES No. complete all as specified and directed.
Supply only Apparatus plate assembly suitable to fix thermostate, heating elements as of geyser and nuts etc complete all as specified and directed.
Supply only Flexible Pipe hot & cold
Removing the tank from the geyser, brazing to arrest the leakage, reassembling and refixing complete all as specified and directed.
Supply only Bottom inspection chamber cover suitable for 25 Ltrs capacity geyser of any make/model complete all as specified and directed.
Supply only Indication lamp suitable for geyser in round/rectangular shape complete all as specified and directed.
Supply and replace 3 pin plug 15 Amps capacity complete all as specified and directed.
Supply only geyser tank of capacity 15 Ltrs made out of stainless steel complete all as specified and directed.
Supply only geyser tank of capacity 25 Ltrs made out of stainless steel complete all as specified and directed.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
BOQ_834562.xls
BOQ • 0.41 MB
8738GENERALPAGES.pdf
Tender Documents • 0.46 MB
8738PS.pdf
Tender Documents • 0.57 MB
Download all tender documents and submit your bid