Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC 759 126A FLAT NO 08 SUNDERBAN APT NEAR DR KELKAR HOSPITAL PRABHAT ROAD PUNE 411004 INDEX NO C 402 HQ CEPZ PUNE | PUNE | MAHARASHTRA | 411004 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹10.3 L+₹1.3 L (14.5%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹10.6 L+₹1.6 L (18.2%)Rejected-Finance | L3 | Rejected-Finance High Rate | |
| 4 | L4₹11.8 L+₹2.8 L (31.5%)Rejected-Finance 173 RASTA PETH NIKHIL APARTMENT SHIRAL SETH CHOWK PUNE 411011 | PUNE | MAHARASHTRA | 411011 | L4 | Rejected-Finance High Rate | |
| 5 | L5₹12.2 L+₹3.2 L (36.0%)Rejected-Finance | L5 | Rejected-Finance High Rate |
Tender Value
₹12.3 L
EMD Value
₹24,500
Closing Date
26 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (Central) Pune, Arjun Marg, Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8498 PROVN OF GEYSER AT BLDG NO P-88, 89 AND 90 AT SINGLE ORs ACCN (OTM) OF AFMC UNDER GE (CENTRAL) PUNE
2024_MES_656614_1
GE (C) P- TOKEN 08 OF 2024-25
Open Tender
Civil Works
Item Rate
150 days
Garrison Engineer (Central) Pune, Arjun Marg
As per Tender NIT
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central) Pune, Arjun Marg, Pune
₹24,500
Yes
3 Sept 2024
29 May 2024
28 Jun 2024
29 May 2024
26 Jun 2024
12 Jun 2024
Amount
Supply and install Electric storage water heater Monza DX of capacity 50 Litrers, vertical type, ISI marked 5 Star rating inner copper tank, heating element, saftey NRV, shock safety plug etc and including all accessories including steel bedded connetions pipe with brass hexagonal adapters both sides, suitable for 15mm dia pipe 45-60cm long for Hot water and cold water complete all as specified and as directed.
S & F vertical type double door TPN DB 4 way IP-43 recess mounting / wall mounted type including incoming MCCB 3 Pole, 25 KA and outgoing 04 Nos MCB TP 63 Amps suitable for three phase out going including necessary provision for inserting the DBs in wall by cutting the brick / stone masonery etc and making good the disturbed surface to match with existing colour of wall complete all as specified and as directed.
S & F MCB TPN DB 4 way, double door with 200 Amps rated bus bar 415 Volts complete all as specified and as directed.
S & F MCB SPN DB 4 way double door with 200 Amps rated bus bar 240 Volts complete all as specified and as directed.
S & F MCB SPN DB 2 way single door 240 Volts complete all as specified and as directed.
S & F MCB TPN 40 Amps, breaking capacity 10 KA, 'B' curve, 415 Volts complete all as specified and as directed.
S & F RCCB 2 Pole , 25 Amps , 30mA to 100mA , 240 Volts, breaking capacity 10 KA complete all as specified and as directed.
M & L for point wiring using approved colour as per IS with multistranded copper conductor 2.5 Sqmm (nominal area) two single core PVC insulated and unsheathed FRLS H cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty PVC Conduit / casing caping ISI Marked of suitable size including all accessories etc with modular sunken / surface boxes 1.2mm thick 60mm deep or PVC surface mounted modular box with earth dolly as per site requirement covered with modular white cover plate with frame suitable for modular switches including PVC insulated multistranded copper conductor 2.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed .
S & F Modular socket outlet 6/16 Amps , 2/3 pin combined multipurpose, flush type, 230 Volts, single pole, one way complete all as specified and as directed.
S & F modular switch 16 Amps, flush type, 230 Volts, single pole, one way complete all as specified and as directed
M & L for Sub main wiring with approved colour coding as per IS with 4 single core 10 Sqmm PVC insulated FRLS H multistranded copper conductor drawn through in and including non-metallic surface PVC conduit and its accessoriesof suitable size inclduing two run of PVC insulated 10 Sqmm FRLS H multistranded copper conductor as earth wire complere all as directed, Note : 4 runs of 10 Sqmm cable , one run of 10 Sqmm earth conductor and one run of PVC conduit shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with 4 single core 6 Sqmm PVC insulated FRLS H multistranded copper conductor drawn through in and including non-metallic surface PVC conduit and its accessoriesof suitable size inclduing two run of PVC insulated 6 Sqmm FRLS H multistranded copper conductor as earth wire complere all as directed, Note : 4 runs of 6 Sqmm cable , one run of 6 Sqmm earth conductor and one run of PVC conduit shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with 2 single core 4 Sqmm PVC insulated FRLS H multistranded copper conductor drawn through in and including non-metallic surface PVC conduit and its accessoriesof suitable size inclduing two run of PVC insulated 4 Sqmm FRLS H multistranded copper conductor as earth wire complere all as directed, Note : 2 runs of 4 Sqmm cable , one run of 4 Sqmm earth conductor and one run of PVC conduit shall be measured as one unit length.
M & L 40mm bore dia medium grade galvanized pipe with all fitting ISI marked, laid in trenches / under floor or fixing on wall / pole / crossing nallah etc complete all as specified and as directed .
M & L 15mm bore dia medium grade galvanized pipe with all fitting ISI marked, laid in trenches / under floor or fixing on wall / pole / crossing nallah etc complete all as specified and as directed .
Cutting steel tubing of size 40/50mm bore dia for alterations or additions (Each cut measured) complete all as specified and as directed .
M & L Bib taps 15mm bore dia, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass furrel and fixed for GI tubes of complete all as specified and as directed .
M & L stop valve 15mm bore dia, fancy type, chromium plated, cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed .
S & F 1000 Litre capacity Rotational moulded polyethelene water storage tanks (cylindrical, vertical with closed top) hoisted & fixed in position including all necessary GI fittings such as nipple, union / sockets etc and connecting up pipes etc complete all as specified and directed.
M & L for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.3mm buried directly in ground earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate vertically to depth of not less than 1.5 Mtr below ground level conncted to and including GI wire 4mm dia and GI pipe 15mm dia light grade for protection to the extent of 7.5 Mtr as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Part-I including RCC cover and MS angle iron frame watering arrangement with GI pipe 20mm dia and MS funnel concrete including excavation and earth work in any type of soil and testing on completion etc complete all as specified and directed. Note :- GI earth wire 4mm dia and 15mm dia protection pipe upto 7.5 metre from earth plate shall deemed to be included in quoted rates.
M & L for brick work with subclass "B" bricks straight or curved on plan not exc 6 Mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for rendering 10mm thick cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr in dept fo laying of LT UG cable / pipes etc and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soil all as specified and directed.
Removing excavated material (soil) to a distance not exc 50 Mtr and depositing where as directed at a level not exceeding 1.5 Mtr above the starting point all as specified and directed
M & L for Reinforced concrete pipes class NP-2 of size 150mm bore dia in 1 RM each half round (for bottom and top ) all as directed. Note :- Two half round pipe (Bottom and top) will be measured asone RM.
Supply, laying, testing and commissionig of LT cables 1100 Volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs including all jointing / connecting acessories as required laid in trenches / ducts / under plinth floors / passing through pipes etc/ fixed on wall of size 35 Sqmm 3.5 Core complete all as specified & directed.
PURVA ELECTRICALS AND ENGINEERS
Sparkh Electricals & Works
M/S - SUJIT ELECTRICALS
CHAITANYA WINDWELL
TIMES HYDRO-ELECTRIC COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .