Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC | ₹17.3 L Quoted ₹18.0 L | L1 | Accepted-AOC Lowest and Reasonable Bid |
| 2 | L2₹19.3 L+₹1.3 L (7.39%)Rejected-Finance | ₹19.3 L+₹1.3 L (7.39%) | L2 | Rejected-Finance Other than lowest Bid |
| 3 | L3₹19.6 L+₹1.7 L (9.27%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | ₹19.6 L+₹1.7 L (9.27%) | L3 | Rejected-Finance Other than lowest Bid |
| 4 | L4₹21.6 L+₹3.6 L (20.2%)Rejected-Finance | ₹21.6 L+₹3.6 L (20.2%) | L4 | Rejected-Finance Other than lowest Bid |
| 5 | L5₹21.6 L+₹3.7 L (20.5%)Rejected-Finance | ₹21.6 L+₹3.7 L (20.5%) | L5 | Rejected-Finance Other than lowest Bid |
| Sl No | Description | Qty | Unit | SRI SAI CONSTRUCTION COMPANY L3 | MISHRA CONSTRUCTION COMPANY L4 | M. S. CONTRACTOR L1 | Ridhi Enterprises L5 | singh enterprises L2 |
|---|---|---|---|---|---|---|---|---|
| .01BOQ (REPAIR/MAINT OF INTERNAL WIRING, MCBS DBS, LT PANELS, UG CABLE, AC PLANT AND ITS CONNECTED ACCESSORIES, GI/CI/MS PIPE AND AMF CONTROL PANELS AT AF STN ANUPGARH) | ||||||||
| 1.00 | Taking down DB/sheet enclosure/metal plug socket/main switch of any size and making good disturbed surface of wall/floor complete all as specified. | 14 | Each | 20 ₹280 Lowest | 30 ₹420 | 100 ₹1,400 | 100 ₹1,400 | 200 ₹2,800 |
| 2.00 | Taking down U/S submain wiring and making good the disturbed surfaces of walls/ floor etc matching with the existing surface. | 160 | RM | 5 ₹800 Lowest | 10 ₹1,600 | 30 ₹4,800 | 10 ₹1,600 | 40 ₹6,400 |
| 3.00 | Taking down carefully switch, socket Regulator, ceilin rose, angular holder /LED lamps/LED lights/ PVC Bd complete and making good disturbed surface of wall/floor, etc. complete all as specified and as directed. | 493 | Point | 10 ₹4,930 Lowest | 15 ₹7,395 | 30 ₹14,790 | 10 ₹4,930 Lowest | 30 ₹14,790 |
| 4.00 | M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including Steel Conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed.
NOTE: (a) Two run of cable with one run of earth wire and one run of conduit will be measured as one length. | 60 | RM | 150 ₹9,000 | 150 ₹9,000 | 100 ₹6,000 | 70 ₹4,200 Lowest | 100 ₹6,000 |
| 5.00 | All as per item No 04 here-in-before but cable of size 2.5 sqmm all as specified and directed. | 50 | RM | 200 ₹10,000 | 225 ₹11,250 | 100 ₹5,000 Lowest | 150 ₹7,500 | 100 ₹5,000 Lowest |
| 6.00 | All as per item No 04 here-in-before but cable of size 4.0 sqmm all as specified and directed. | 50 | RM | 250 ₹12,500 | 300 ₹15,000 | 100 ₹5,000 Lowest | 250 ₹12,500 | 100 ₹5,000 Lowest |
| 7.00 | S&F 5 Amp switch piano type single pole one way all as specified and as directed. | 100 | Each | 25 ₹2,500 | 30 ₹3,000 | 22 ₹2,200 Lowest | 60 ₹6,000 | 22 ₹2,200 Lowest |
| 8.00 | S&F socket flush type 6 amps, 5 pin, 230v all as specified and as directed. | 50 | Each | 50 ₹2,500 | 50 ₹2,500 | 35 ₹1,750 Lowest | 70 ₹3,500 | 35 ₹1,750 Lowest |
| 9.00 | S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v. Complete all as specified and as directed. | 20 | Each | 160 ₹3,200 | 200 ₹4,000 | 145 ₹2,900 Lowest | 150 ₹3,000 | 145 ₹2,900 Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
31 Oct 2025, 6:00 pmClosed
GE AF SURATGARH
GE AF SURATGARH
REPAIR/MAINT OF INTERNAL WIRING, MCBS DBS, LT PANELS, UG CABLE, AC PLANT AND ITS CONNECTED ACCESSORIES, GI/CI/MS PIPE AND AMF CONTROL PANELS AT AF STN ANUPGARH
2025_MES_729121_2
8260/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF SURATGARH
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE AF SURATGARH
₹40,000
Yes
15 Dec 2025
16 Oct 2025
3 Nov 2025
16 Oct 2025
31 Oct 2025
23 Oct 2025
Amount
BOQ (REPAIR/MAINT OF INTERNAL WIRING, MCBS DBS, LT PANELS, UG CABLE, AC PLANT AND ITS CONNECTED ACCESSORIES, GI/CI/MS PIPE AND AMF CONTROL PANELS AT AF STN ANUPGARH)
Taking down DB/sheet enclosure/metal plug socket/main switch of any size and making good disturbed surface of wall/floor complete all as specified.
Taking down U/S submain wiring and making good the disturbed surfaces of walls/ floor etc matching with the existing surface.
Taking down carefully switch, socket Regulator, ceilin rose, angular holder /LED lamps/LED lights/ PVC Bd complete and making good disturbed surface of wall/floor, etc. complete all as specified and as directed.
M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including Steel Conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of conduit will be measured as one length.
All as per item No 04 here-in-before but cable of size 2.5 sqmm all as specified and directed.
All as per item No 04 here-in-before but cable of size 4.0 sqmm all as specified and directed.
S&F 5 Amp switch piano type single pole one way all as specified and as directed.
S&F socket flush type 6 amps, 5 pin, 230v all as specified and as directed.
S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v. Complete all as specified and as directed.
S&F lamp Holder insulated body with back plate for batten fitting one all as specified and as directed.
S&F LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) CFL.
S&F ceiling rose surface Bakelite three terminal all as specified and as directed.
S&F flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, 50 Hz all as specified and as directed.
S&F as in replacement MCB, Single Pole, 6 to 32 amps, 240 volts, 10 kA breaking capacity, "C" curve. complete all as specified and as directed.
S&F as in replacement MCB, Double Pole, 6 to 32 amps, 240 volts, 10 kA breaking capacity, "C" curve. Complete all as specified and as directed.
S&F as in replacement MCB TPN 63 Amps, 415 volt 10 KA, complete all as specified and directed by Engr-in-Charge.
S&F MCB distribution board,Double door, metal enclosure, SPN, 230 Volts, 4 way all as specified and directed.
S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 8 way one all as specified and directed.
S&F MCB distribution board, Double door, metal enclosure, TPN, 415 Volts, 4 way all as specified and directed.
S&F Vertical MCB distribution board, as MCB incomer, Double door, metal enclosure, TPN, 415 Volts, 4 way all as specified and directed.
S&F Vertical MCB distribution board, as MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way all as specified and directed.
S&F Metal plug and socket board with MCB SP 20 amp, 16 KA all as specified and directed.
S&F Sheet metal enclosure two way, all as specified and directed.
S&F as in replacement LED batten fitting 2 feet long, 10 watt, CDL 230 Volts , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 nos all as specified and directed.
S&F as in replacement LED fitting, 20 watt, CDL, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable all as specified and directed.
S&F as in replacement LED building security light 25 watt, 230V with lens and toughen glass top complete PF > 0.95 with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20/25 mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener. Complete all as specified and directed.
Taking down of existing ceiling fans, opening / dismantling of fan & fan blades, cleaning, servicing,oiling, greasing, carrying out repairs such as replacement of capacitors, bearings, bushes, canopy, clamp, safety pin, rubber bush, rewinding fan motor and re-fixing of the same ceiling fan of any sweep including provision of new cable from ceiling rose/ connector to fan and spray painting of ceiling fan with with two coats of synthetic enamel paint after prepartion of surfaces, complete all as specified and directed.
All as per Ser Item No 35 here in before but ex-fan of any sweep. Complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of cable /pole /pipe and getting out in soft loose soil. Complete all as specified and directed.
All as per item No.29 above but depth exceeding 1.5 m and not exceeding 3 m. Complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick. Complete all as specified and directed.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. Complete all as specified and directed.
PCC (1:3:6) type C-2 using 40mm graded aggregate as in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed.
PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of pole, including necessary form work complete all as specified and directed
Material and labour for river washed and screened, dry sand for filling in trenches 8 cm below cable and 15 cm above cable and punned down gently to achieve 10 cm thickness of top layer for cushioning of cables etc, complete all as specified. Note: for payment purpose thickness after punning 18 cm will be measured and paid
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismentling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit.
Supply & laying of LT UG cable XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 06 Sqmm 2 core as per IS 7098 (Part-I) laid in trenches/ fixing on panels/walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and directed. (Note: (i) Cable joint shall be measured and paid separately.)
All as per item No. 38 here-in-before but 10sqmm 4 core complete all as specified
All as per item No. 38 here-in-before but 16sqmm 4 core complete all as specified
All as per item No. 38 here-in-before but 25sqmm 3,5 core complete all as specified
All as per item No. 38 here-in-before but 50sqmm 3.5 core complete all as specified
All as per item No. 38 here-in-before but 70sqmm 3.5 core complete all as specified
All as per item No. 38 here-in-before but 95sqmm 3.5 core complete all as specified
All as per item No. 38 here-in-before but 120sqmm 3.5 core complete all as specified
Labour only for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board at existing places or carrying to other location, upto 1100 volts grade heavy duty cable with XLPE/PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size upto 25 sqmm 4 core obtained from item no-37 here-in-before with required aluminium cable lugs, heat shrink joints
All as per item No. 46 here-in-before but 35 sqmm 3.5 core to 120 sqmm, 3.5 core complete all as specified and directed
Mannual road cuttiug including making good to disturbed surface with PCC 1:2:4 type B2 on top not less than 150 mm thick including levelling and cambering according to existing road surface, refilling, watering, ramming etc complete all as specified and directed
Dismentling/ taking out broken/worn out steel pole/PCC Pole of 8.5 to 9.50 mtr long and kepping aside for refixing or removal from site. Complete all as specified and directed.
Supply and erecting in true vertical position steel tubular swaged pole, 9 metre long, type 410 SP-31 confirming to IS : 2713 including drilling of holes of required size and nuts for fixing of cross arms complete with mild steel base plate 6mm thick of size 300mm x 300mm, finial taper plug bolts, nuts, washers and screws,, painting with two coats of aluminium paint over a coat of red oxide and two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacing complete all as specified and directed. (Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of Sch 'A').
Labour only for re-fixing of steel tubular swaged pole complete with cast iron base plate , painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type (9 mtr long).
Painting of steel pole any type up to 7.5 mtr height above ground level including cross arms,clamps,stay clamps etc with two coats of aluminium paint after surface preparation all as directed by Engr-In-Charge
Numbering of steel poles serially with letter/number size width and height up to 40 mm in situ with black paint on white back ground
Supply and fix Heat shrink straight through joint LT 1100 volts grade 10-16 sqmm, 4 core including exacavation work. Complete all as specified by Engr-in-Charge.
Supply and fix Heat shrink straight through joint LT 1100 volts grade 25-50 sqmm, 4 core including exacavation work complete all as specified by Engr-in-Charge.
Supply and fix Heat shrink straight through joint LT 1100 volts grade 70-150 sqmm, 4 core including exacavation work complete all as specified by Engr-in-Charge.
Supply and fix Heat shrink straight through joint LT 1100 volts grade 185-300 sqmm, 4 core including exacavation work complete all as specified by Engr-in-Charge.
Supply and fix GI tubing light grade 40mm bore on pole /wall with necessary clamps, nuts, bolts and washers under road cross for cable protection. Complete all as specified and directed.
Supply and fix GI tubing light grade 50mm bore on pole /wall with necessary clamps,nuts,bolts and washers/under road cross for cable protection. Complete all as specified and directed.
Supplyand fix GI tubing light grade 80mm bore,on pole /wall with necessary clamps,nuts,bolts and washers/under road cross for cable protection. Complete all as specified and directed.
Labour for disconnecting LT/HT cable of any size from structure/pole/transformer for finding fault, M&L for defect rectification LT/HT cable laid in trenches or any location by locating fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge as specified. Note:- 0900 to 1100 Hrs and has to be rectified with in 12 hours after notification, failing to which Rs500/- per day complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quioted rate all as specified and directed by Engr-in-charge. joint kit will be measured seperately in appropriate item in this schedule
Labour for filteration and dehydration of transformer oil by dehydration machine to achieve the die-electric strength/ insulation value upto 70VKV (RMS) at standard gap of electrodes 2.5 mm for one minute in 11 KV/0.440 KVA transformer capacity 315 KVA including insulation testing of oil with help of suitable equipments before and after dehydration including BDV Test compete all as specified and directed. Note: (i) Contractor will have to arrange the dehydration machine and transformer oil dielectric strength testing equipment as mentioned and same shall be deemed to be included in the item rate quoted. (ii) Test result of transformer oil before and after dehydartion is required to submit by contractor duly signed by all concerned. (iii) The contractor shall ensure that the conservator tanks are full to its level before commencement of dehydration process. (iv) Additional quantity of transformer oil if any required for making the oil level upto the requirement in transformer shall be measured and paid separately as supply and filling but its cost of heating shall be deemed to be included in the rate quoted for above item.
Supply and filling transformer power oil meeting IEC 60296-2003-11, 3rd edition standard specification and ASTMD 1275B test requirements for corrosive sulpher of BDV not be less than 70 KV at 2.5mm gap for reduced level of transformer in distribution transformer HT 11 KV reduced level of transformer due to evaporation/ leakage/losses due to dehydration all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of transformer HT/LT bush as per site requirement suitable upto 315 KVA transformer after disconnecting underground HT/LT cables and earth strips etc and reconnections, testing and recommissioning of transformer to full satisfaction of Engineer-in-charge.
Labour only for disconnecting LT/HT cable of any size from pole (height 7.5 to 9 mtr) /transformer/panel and re-connecting of cable at both end after removing carbon /burnt insulation part of cable by cutting refixing cable with new cable lugs . The entire repair work to be completed with in 06 hours of instruction from Engr-in-charge all as specified. Note:- Complaint between 0900 to 1100 Hrs and has to be rectified with in 06 hours after notification, failing to which Rs 500/- per day will be recoverd per complaint.
M & L for earthing complete with galvanised steel Earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 32x6 mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50 metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. Note : GI strip 32x6mm upto 7.5 metre with 40mm protection pipe shall be included in quoted rate and beyond that the same will be measured separately.
M & L for earthing complete with copper Earth plate electrode 600X600X3.15 mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to copper strip 20x3 mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50 metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. Note : Copper strip 20x3mm upto 7.5 metre with 40mm protection pipe shall be included in quoted rate and beyond that the same will be measured separately.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip
Supply and fixing as in replacement MCCB, 4 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 200 amps. Complete all as specified and directed.
Supply and fixing as in replacement MCCB, 4 pole,36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 160amps. Complete all as specified and directed.
Supply and fixing as in replacement MCCB, 4 pole,36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 125 amps. Complete all as specified and directed.
Supply and fixing as in replacement MCCB, 4 pole, 25 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 100 amps. Complete all as specified and directed.
Supply and fixing as in replacement MCCB, 3 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release 400 amps. Complete all as specified and directed.
M & L as in replacement three core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through existing PVC Conduit street light to pole box and making good to disturbed surfaces all as specified and directed.
Supply and fixing 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 2.5 sqmm and overall PVC sheathed in service connections from OH conductor to building/street light to pole box incl dismentling taking down unserviceable one all as specified and directed.
All as per item No. 75 here-in-before but 4 sqmm core complete all as specified and directed.
All as per item No. 75 here-in-before but 6 sqmm core complete all as specified and directed.
S & F street light pole box (SMC) type suitable for fixing on LT pole size 30cmx25 cmx15cm with side hinged door and locking arrangment and suitable for terminal single phase including MCB 6-10A SP and fixing in position with nut, bolt, clamp, disconnection and reconnection of service wire/UG cabel in box incl dismentling old street pole box all as specified and directed.
M & L for street light bracket, made out of 40 mm dia GI pipe, (medium grade) 1.5 metre long bend to shape as required with nut bolt and clamp and fixing in position incl dismentling taking down unsv complete all as specified and directed.
Supply & fix as in replacement of LED 60W street light, with IP-66 protection and efficiancy of 110 lummen per watt aesthetically designed roadway luminiare with excellent thermal management, pressure die-cast aluminium alloy for housing (heat sink) with epoxy powder coated with high efficiency long life LED chip inbuilt with electronic driver with APFC. complete all as specified and directed.
All as per item No. 80 here-in-before but 70 watt complete all as specified and directed.
All as per item No. 80 here-in-before but 90 watt complete all as specified and directed.
S&F as in replacement LED flood light fitting 150 watt complete with all fittings incl 1.5 sqmm three core copper flexible conductor cable. Complete all as specified and directed.
Repair to any type of LT panel with cutting necessary worn out portion of MS sheet, providing MS sheet of 2mm, MS angle iron of existing size and hinges to broken door etc fixed with electric arc welding, providing external locking arrangement after taking proper elctric shutdown.
S&F surface mounting time switches, daily dial, , incl dismentling taking down unsv one.
S&F 3 pole power contactor, 415Volts, 40 amps, , incl dismentling taking down unsv one.
M&L for taking up rusted GI steel tubing incl all fitings from trenches of 20 mm bore complete all as specified and directed
M&L for taking up rusted GI steel tubing incl all fitings from trenches of 25 mm bore complete all as specified and directed
M&L for taking up rusted GI steel tubing incl all fitings from trenches of 40 to 50 mm bore complete all as specified and directed
M&L for taking up rusted GI steel tubing incl all fitings from trenches of 80 mm bore complete all as specified and directed
M&L for taking up rusted GI steel tubing incl all fitings from trenches of 100 mm bore complete all as specified and directed
S & F and Laying in trenches/fixed to wall galvanised steel water tubing 20 mm bore, medium grade with and including all medium grade fittings complete all as specified.
All as per item No. 92 here-in-before but of size 25 mm bore complete all as specified.
All as per item No. 92 here-in-before but of size 40 mm bore complete all as specified.
All as per item No. 92 here-in-before but of size 50 mm bore complete all as specified.
All as per item No. 92 here-in-before but of size 80 mm bore complete all as specified.
All as per item No. 92 here-in-before but of size 100 mm bore complete all as specified.
S&F as in replacement CI body non raising spindle sluice valve 80 mm bore with cast iron wheel, class PN-1.6 with SS spindle with brass nut, both ends flanged confirming to IS-14846 with standard bolts hole, fixing with nuts, bolts, washers, rubber gasket etc complete in position of pipe line all as specified and directed. Note: (i) Nuts, bolts & washers whenever require new shall be measured and paid separately as supply only. (ii) Rubber gusket shall be inclusive of the quoted rate of this item.
All as per item No.98 here-in-before but size 100 mm bore complete all as specified
S&F in repair gun metal gate valve with iron wheel head, screwed both ends for iron pipes 15mm bore complete all as specified and directed
All as per item No. 100 here-in-before but of size 20 mm bore complete all as specified.
All as per item No. 100 here-in-before but of size 25 mm bore complete all as specified.
All as per item No. 100 here-in-before but of size 40 mm bore complete all as specified.
All as per item No. 100 here-in-before but of size 50 mm bore complete all as specified.
All as per item No. 100 here-in-before but of size 80 mm bore complete all as specified.
Supply & fixing in repair of cast Iron foot valve confirming to IS : 4038 flanged end with rubber gasket, Nuts, bolts & washers of sizes 80 mm bore.
Disconnecting/ dismatiling of centrifugal monoblock pump set of 1 HP capacity of pump any RPM and dismantiling defective parts such as impeller nut,glant,impeller key,gland packing water deflector bush bearings sleeve,gaskets stud and nuts suction and delivery flange and stud and nuts and all other petty items required to make the pumpset functional and reassembling the pumpset including installation commissioning and testing, complete all as specified and directed by Engineer-in-Charge.
All as per item No: 107 here-in-above but capacity of motor 2 HP as per existing make.
All as per sl item No: 107 here-in-above but capacity of motor 5 HP as per existing make.
All as per sl item No: 107 here-in-above but capacity of motor 7.5 HP as per existing make.
Dismantling taking out complete submersible pump of capacity 7.5 HP of different models from borewell including dismentling taking out delivery pipe from GL to pump by opening flange/socket joints, carrying to wksp for rewinding & back and fixing to original position after repair along with delivery pipe, nuts, bolts, washers including testing, commissioning all as specified and directed.
Repair /servicing of Centrifugal pumping set by replacing all worn out parts such as bearing, bushes, shaft key, etc , Varnishing of motor, Greasing of Motor bearings for making smooth functioning of pumping sets. Capacity of Pump Set 5/7.5 HP, 3 phase, 415 volt.
S & F in repair star delta starter suitable for 7.5 HP pump including prewired all as specifed and directed by Engr-in-Charge. Make: BCH/SCHNEIDER/SIEMENS/ABB
Repair & servicing of existing pump star delta starter panels of any size and capacity by replacing unserviceable components such as contactor, relays, etc and tightening of all connecting points, cable connections including replacement of wires where required complete all as directed. (Note :- Parts required for replacement shall be measured and paid seperately as supply only under appropriate items given here in after.)
Supply "O" Todoline solution for water testing purpose in 500 ml bottle make Nice/Glaxo or equivalent all as specified and directed by Engr-in-Charge.
Supply only chlorine test kit with sample for water testing purpose all as specified and directed by Engr-in-Charge.
Supply and fix 3 pole power contactor AC, 415 Volt, with required NO + NC & Coil voltage 380V to 400V, suitable for upto 7.5 HP water pump. Complete all as specified and directed.
Supply and fix Thermal over load relay for 3 Phase AC Motor starter, suitable for 30 HP water pump, relay setting range 12.0 to 30.0 Amps.
Labour for complete service of RO Plant of capacity 250Ltr/hrs including replacement of all bag filters, cartidge filter, backwash of membrane (including chemical), tightning of all bends and coupling of PVC pipe etc, complete all as specified and directed by Engineer-in-Charge. Note : Spares shall be measured and paid separatly as supply only under subsquent items
S&F industrial RO plant membrane model No. 40L30N (Pentair) complete all as specified and directed.
M&L for replacement of wound filter Cartidge filter of 5µ (Microns) and filter media polypropylene Fiber Core size 40"X2.5" of RO plant of capacity 250 Ltr/hrs complete all as specified and directed
M & L for Chemical (sodium hydroxide citric acid) Anti scaling for RO Plant of capacity 250 Ltr/hrs, complete all as specified and directed.
M & L for Chemical used for maintaining PH value RO water within permissible limit, complete all as specified and directed.
M & L for activated carbon (GAC) for removing the impurities from water in the carbon filter of RO Plant, complete all as specified and directed.
Maintenance and servicing of DG set 160 KVA,Make: Greaves Ltd including replacment of defective/wornout spares with new spares such as fule filter, lube oil fiter, gaskets, V belts,rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner and replacement of Engine oil, tappet setting ,servicing of radiator etc for the smooth operation DG set all as specified and directed. Note: 1) Minor spares such as fule filter and oil filter required for the service / Maintenance of the DG Sets deemed to be included in the above quoted rate. 2) spares required for above will be measured and paid separately under relevent items of Sch. Location: Anupgarh pump house.
All as per above item No 125 here in before but capacity 20 KVA DG set
Supply and fix Air filter element inner and outer as required at site with 'O' ring as required at site for capacity of 20 KVA DG set
Supply and fix Air filter element inner and outer as required at site with 'O' ring as required at site for capacity of 160 KVA DG set
Supply and fix only ignition switch with key in repair for DG sets of any capacities all as directed by Engineer-in-charge.
Supply and filling/ top up coolant for DG set radiator all as specified and directed
Supply only lube oil SAE 15 W - 40 of approved make for Top up and filling up the oil in the sump after completely flushing the old oil out of the tank and cleaning of the tank for fresh filling all as directed by Engineer-in-charge.
Taking down unserviceable fuel injection pump from any type/ capacity DG set, carrying to workshop and repairing including necessary spares and calibration, refixing the same duly repaired to its original position and testing for its serviceability at site complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of Self starter assy for DG set of 160 KVA 24 Volts DC including , complete fixing & testing.
Supply and fix in replacement of turbo charger of existing make and model as directed by Eng in charge for capacity 20 KVA DG Set
Supply and fix in replacement of turbo charger of existing make and model as directed by Eng in charge for capacity 160 KVA DG Set
M&L for opening/dismantling and disconnecting all the connections from panel to terminal box, repair/replacing the field coils to the alternator, refixing the field coils to the alternator after drying the varnish and making the electric connections to terminal box with proper brass nut bolts and washers testing and commissioning for satisfaction for the capacity 20 KVA DG set
M&L for opening/dismantling and disconnecting all the connections from panel to terminal box, repair/replacing the field coils to the alternator, refixing the field coils to the alternator after drying the varnish and making the electric connections to terminal box with proper brass nut bolts and washers testing and commissioning for satisfaction for the capacity 160 KVA DG set
M&L for dismantling of radiator from type of DG sets from engine taking it to work shop for repair of leakage pipes, cleaning the radiator with cleaning agents, re-assembling to the engine complete as per the satisfaction of Eng in charge.
Inspection/checking of AMF panel of DG set of any capacity by an authorised Engineer having full knowledge of AMF panel/Controller/ DG sets installed at various installations of any make and shape, rectification of defects and cleaning, detecting during inspection or pointed out by users/department replacement of unserviceable part and carry out maintenance complete all as specified and directed by Engr-in-Charge. Note:- Spare parts required shall be measured and paid separately or issued by the department.
Taking out old unserviceable main controller and Supply and fixing the new controller of existing make and model suitable for any capacity DG set all as directed by Engr in charge.
Supply and fix 4 Pole power contactor with AC coil 200 Amps, 3 phase 415 volt 50 HZ suitable for AMF panels. Complete all as specified and directed.
Supply and fix only engine start relay 24 volt DC suitable for AMF panels .
M&L for replacement of unserviceable/wornout control wiring of AMF panel of any capacity DG set with existing size of cable for complete AMF panel and testing complete all as specified and directed. Note:Team for repairing of DG and AMF panel should be ready at every time with all necessary equipments during working hours and repair action should be started within 60 Minutes after complaint intimation to contractor/ superwiser through phone call or text message or by any other means.1000 Rs penalty shall be imposed at each violation of above direction.
S&F on load change over three phase and neutral , 440 volts, 320 Amp with box and accessories all as specifed and directed by Engr-in-Charge.
Labour only for arrangement of authorised engineer (service engineer of AC unit's company having suitable licence) visit to identify the breakdown of any type of AC Plants and for PLC setting like temp/ voltage range setting and to carry out the neccesary repair up to the complete satification of Engineer in charge. Note : Any minor item needed to repair shall be included in quoted rate.
Supply and charging of Refrigerent R-407 C in sealed container complete all as specified and directed. Note:- Contractor will have to use sealed container and have to show weight of container before and after gas charging, so that exact weight of gas can be calculated.
Cleaning and washing of microfilters of AHU of any capacities up to the satisfaction of Engineer In Charge including any other minor repair needed in AHU. Any broken filter shall be replaced with new one and same shall be paid in quoted rate, complete all as specified and directed.
Cleaning of cooling tower with one or two as per existing size, water basin and makeup tank with the help of chemical and nylon brush,removing and refixing of PVC finches after washing, cleaning of condenser pipe line( in let and out let) including painting of out side of cooling tower with inlet and out let pipe line with one coat synthetic enamel paint of colour approved by engr in charge and inside painting of water tank of cooling tower used water proof black japan paint one coat including changing of unserviceable PVC guard water distributor, PVC pipe, cooling tower motor etc complete for the satisfaction of the Engr-in-charge of the 50 TR capacity of the AC plants at different locations complete all as specified and directed.
Taking down old unserviceable motor pump coupling set of any size and S&F testing and commissioning of new motor pump coupling complete set along with rubber star coupling suitable for any capacity centrifugal pump set complete all as specified and directed by Engineer in charge.
Taking down old unserviceable motor pump coupling's star rubber of any size and S&F testing and commissioning of new motor pump coupling's star rubber set suitable for any capacity centrifugal pump set complete all as specified and directed by Engineer in charge.
S & F in repair Chiller motor bearing complete all as specified and directed by Engineer in charge.
S & F in repair of AHU Panel wiring complete all as specified and directed by Engineer in charge.
Disconnecting, dismantalling the defective three phase induction motor 415 Volts of fan motors 50 HZ of any RPM for 5 HP capacities and re-winding with super enamelled copper wire of best quality of existing size/gauge and weight inciuding raplacement of insulation material,varnish bearing connection plate and all other petty items required to make the motor functional and reassembling the motor including installation commissioning and testing on full load, complete all as specified and directed by Engineer-in-Charge.
All as per ser item No 153 here-in-above but capacity of motor 7.5 HP.
All as per ser item No 153 here-in-above but capacity of motor 10 HP.
Supply and charging of Refrigerent R-22/R-32 in sealed container complete all as specified. Note: Contractor will have to use sealed container and have to show weight of container before and after gas charging, so that exact weight of gas can be calculated.
S&F in replacement starting capacitor 120-150 mfd suitable for 1.5/2 Ton Air conditioner windwo type/split type complete all as specified.
S&F in replacement reciprocating compressor/rotary type or as per existing of 1.5/2 Ton Capacity for window type/split type AC including soldering of ceopper pipe, cleaning of the refrigerant system of split AC and rubber pads for foundation, nuts and bolts etc, and tesing of split AC complete all as specified and directed by Engr-in-Charge.
S&F in replacemnt of PCB for split type/ window typ Air conditioner of 1.5/2 Ton capacity suitable for particular Make of AC and Making Proper connection and testing complete all as specified.
S&F in replacement voltage stabilizer for automatic operation single phase air cooled indoor type input variation between 170 V to 280 V with output voltage stablized at 230 V wall mounting or capacity 3 KVA to 5 KVA complete all as specified and directed. Make: Microtek/ Volina/IECO/Vinitec
M&L for sevcing window and split type air conditioner/Tower air type conditioner any type /size and make upto 2 TR including cleaning all acomponents thoroughly , oiling, greasing of blower motor, decarboning of all ecetric connections, reconnecting , cleaning and washing of filters, descaling & cleaning of conditioner fins with brush and replacement of screws /nuts/, assembly and tesing complete after servicing complete all as specified and directed,
S&F in replacement of temprature sensor of window type AC /split type AC as per sample complet all as specified
S&F in replacement of copper condenser of approved quality and make suitable for 1.5/2 Ton capacity window type AC /split type as per sample complet all as specified
S&F in replacement blower motor of window/split AC of capacity 1.5 to 2 TR operation single phase air cooled indoor type input variation between 170 V to 280 V complete all as specified and directed.
S&F in replacement desert water cooler pump with pipe complete all as specified and directed.
Supply & fix ceiling fan capacitor of capacity 1.5 mfd all as specified and directed by Engr-in-Charge
Supply & fix desert cooler/exhaust fan capacitor of capacity 3/4/ 5 mfd all as specified and directed by Engr-in-Charge
S & F in replacement grass net as per existing size of desert water cooler. Complete all as specified and directed.
S&F in replacement of aluminium insulation for outdoor pipeline of AC plant dia of pipe 100 mm, with all connected items and acessories complete all as specified and directed.
M&L for brazing for GI/Aluminim strips of various sizes laying on wall /roof etc with the help welding machine and skilled tradesmen by using welding rod etc by taking safety precautions during brazing as directed by the AGE E/M / users, including takingdown unservicable GI strips complete all as specified and as directed by Engr in Charge.
M&L for in replacement of water flow switch for AC plant condensor/chillar complete all as specified fied and as directed by Engr in Charge.
Supply and Install complete indoor unit of Split AC with PCB, Cordless remote control, inbuilt air ioniser & plasma filter for better indoor quality of capacity 2 TR for automatic operation single phase 230 Volt with complete wall mounting accessories and copper piping connection incl taking down old U/S unit and complete all as specified and directed.
Supply and Install, commissioning and testing induced draft top discharge counterflow type FRP cooling tower (rectangular/round bottle shape of capacity 50 TR as per site reqmt) with FRP body and base, water spray, headers, cooling tower fills, fan with 3 HP motor, supporting base frames, drain connection suitable GI inspection ladder, steel suppoting structure, anti vibration mounting as per manufacturer's std instructions. complete all as specified and directed. Make: Mihir/Paharpur/Advance/Delta
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary of tender documents.
singh enterprises (BID ID -3469608)
SRI SAI CONSTRUCTION COMPANY (BID ID -3463919)
MISHRA CONSTRUCTION COMPANY (BID ID -3463929)
Ridhi Enterprises (BID ID -3464438)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.93 MB
Tenderdocs8260.pdf
Tender Documents • 0.86 MB
BOQ_823602.xls
BOQ • 1.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .