| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹31.5 L+₹41,415.70 (1.33%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹31.8 L+₹73,547.50 (2.37%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹32.6 L+₹1.5 L (4.75%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹33.4 L+₹2.3 L (7.30%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹41.5 L
EMD Value
₹82,900
Closing Date
31 Dec 2024, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
SPECIAL REPAIR TO OTHER RANK MARRIED ACCN BUILDING NO P 80 AT ADM AREA CPE ITARSI UNDER GE BHOPAL
2024_MES_686390_1
8343/E8
Open Tender
Civil Works
Item Rate
183 days
ITARSI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹82,900
Yes
4 Mar 2025
29 Nov 2024
2 Jan 2025
29 Nov 2024
31 Dec 2024
19 Dec 2024
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Demolition of un reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement morter beddind (but not backing removing seviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in roof kerbs or mud stops, bed blocks, benching etc including necessary form work complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed.
M&L for 25 mm thick cement concrete (1:2:4) type B-1 using (20 mm graded crushed stone aggregate) as in sub base of flooring, surface finished rough to receive floor topping complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in sub base floor complete all as specified and directed.
M&L for 75mm thick cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate as in plinth protection, surfaces finished even and fair without using extra cement as in plinth protection including provision of construction joints complete all as specified and directed.
M&L non-skid ceramic tiles coloured 7 to 8 mm thick (square/ rectangular), premium quality area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and incl screed bedding 15mm thick in cm(1:6) complete all as specified and directed.
M&L for joint less non - skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl screed bedding 15mm thick in cm(1:6) complete all as specified and directed.
M & L for joint less non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm,as in skirting or vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to matchover and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and directed.
M&L for glazed ceramic coloured (colour & shade as approved) tile 350x250x7 mm/450x300x7mm thick on vertical surface such as skirting / dados set and jointed in neat cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white/ coloured cement with pigment to match the colour of tiles complete all as specified and directed.
M&L for 18 to 20 mm thick cudappa stone/Baroda green marble in single piece incl nosing at front and sides in steps, jambs, pillars, window cills, cooking platforms, staircase and like with bull nosing in cm(1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including making grooves for slip guard or steps,edge moulding, making 30 mm dia hole in cooking counter slab and green marble top for gas pipe including 15mm thick screed bed in cm 1:6 complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
Taking down/removing existing roof teatment including backing coat and cleaning of roof slab surfaces including sweeping clean and washing down with water to remove dust and M&L for providing water proofing treatment with polymeric standard water proofing membrane complete all as specified and directed. Note:- (a) Applying 15 mm thick plaster in cement mortar (1:3) using water proofing compound to roof and similar work finished the surface even and smooth without using extra cement. (b) Applying evenly a tack coat of industrial bitumen 85/25 @1.20 Kg/sqm. (c) Supplying and laying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application including coping on the surfaces with torch application of membrane with 10cm over laps as required. (d) (iv) Ponding test shall be done for 72 hrs.
M&L for heat resistant terrace tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and directed.
M&L for exterior grade coloured tile of texured finish of 300x300x10 mm thick vitrified tile as in floors, steps etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incluidng 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins, arches, pillars etc complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in c:m 1:6 complete all as specified and directed.
All as per srl item No 18 here-in-before but using old bricks retrieved from dismantling here-in-before including cleaning and removal of mortar from old bricks etc complete all as specified and directed.
Taking down cement plaster on brick walls of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on fair face of brick walls or concrete surfaces, finished fair and even without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on other than face of brick walls or concrete surfaces, finished fair and even without using extra cement using WPC complete all as specified and directed. Note:-WPC will be measured and paid separately
Supply only integral water proofing compound (WPC) ISI marked complete all as specified and directed.
M&L for rendering 5 mm thick cement plaster on ceiling surfaces in cement mortar 1:3 finished fair and even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling & applying two coats of white wash complete all as specified and directed.
M&L for preparation of old surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
M&L for 3mm thick wall care putty on wall newly plaster surface complete all as specified and directed.
M&L for preparation of newly plastered surfaces of Wall & applying two coats coats of oil bound distemper over a coat of primer complete all as specified and directed.
M&L complete removal of existing treatment of wall including washing, rubbing down and stopping of old treatement and material and labour for applying two coats of distemper oil emulsion paint, white or tinted over on walls complete all as specified and directed.
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces of walls complete all as specified and directed.
M&L for complete removal of existing treatment preparation of old plastered/unplastered surfaces of walls incl brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil & greasy spots and applying two coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size not exceeding 1.5 Sqm each complete all as specified and directed.
All as per srl item No 32.00 here-in-before but size exceeding 1.5 Sqm and not exceeding 4 Sqm each complete all as specified and directed.
S&F factory made single extruded WPC (Wood polymer composite) soild door/window /ceosetory windows and other frames/chowkat of size 65x100mm comprising of virgin PVC polymer of K value 58-60 (suspension grade) calcium carbonate and natural fib (wwod powder/rice husk/wheat husk) and fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minumum frame densit of 750kg/cum screw withdrwal strenth of 2200 N (Face) and 1100N (Edge) minumum compressive strength of 58N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of class A category with properly of being termite/border proof, water /moisture proof and fire retardant and fixed in position with MS hold fast/lug/SS dash fasterrs of required dia and length complete all as specified and directed. (MS hold fast/lug or SS dash fastteners shall be paid respectively) Note For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
S&F factory made single extruded WPC (Wood polymer composite) soild door/window /ceosetory windows and other frames/chowkat of size 65x125mm comprising of virgin PVC polymer of K value 58-60 (suspension grade) calcium carbonate and natural fib (wwod powder/rice husk/wheat husk) and fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minumum frame densit of 750kg/cum screw withdrwal strenth of 2200 N (Face) and 1100N (Edge) minumum compressive strength of 58N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of class A category with properly of being termite/border proof, water /moisture proof and fire retardant and fixed in position with MS hold fast/lug/SS dash fasterrs of required dia and length complete all as specified and directed. (MS hold fast/lug or SS dash fastteners shall be paid respectively) Note For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
S&F for factory made 30mm thick 100% Solid WPC ( Wood polymer Composite ) laminated wiremesh door shutter of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm manufactured by "RAJSHRI" an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter. For fixing Mosquito mesh and XTN aluminium mesh combinly panel area of door except stiles and rails to be panelled with mesh with self tapping round headed scresws at required distance, scres and edges covered with feathered pvc edge beading all around of mesh and fixing stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company.
S&F for factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
S&F stainless steel plate rack of standard pattern & of size 900 x 750 x 250 mm, the thickness of stainless steel sheet shall be 1.00 mm & grade of sheet shall be 304 S, ISI including fixing to wall with 4 Nos 50mm screws & PVC rawl plugs complete all as specified and directed.
Supply and fixing for aluminium powder coated aluminium window having three track with aluminium section 92 mm X 31.75 mm (Weight bottom section 1.070 kg/m, top section 0.933 kg/m, shutter section 40 mm X 18 mm (weight of handle section 0.417 kg/m) interlock 0.547 kg/m ( Minimum thickness of powder coating 50 micron) mounted on bearing to slide on tracks plain anodized in approved shade including supply and fixing of 5mm thick plain glass and wire mesh, PVC track gasket, EPDM rubber gasket on glass of weather tightening along with locks, handle including sealing gap with marble surfaces with silicon sealants making it water proof in all manner etc complete all as specified and directed.
Supply and fixing for aluminium powder coated ventilator having ( Minimum thickness of powder coating 50 micron)fixed glass with aluminium section having section 50.80 mm x 25.40 mm (weight 0.489 kg/m) glazing clear section (weight 0.109 kg/m) with plain anodized including supply and fixing of 5mm thick frosted glass making frame and glass water tightening making it good etc complete all as specified and directed.
S&F for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in chajja roof covering/ cladding to wall, fixed with self tapping screws as specified with 'J' or 'L' hook / suitable screw complete all as specified and directed.
S&F of framed work such as grills, gratings, etc with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work con- forming to Fe-290 Gde E-165 complete all as specified and directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet rainforced with MS square tube complete all as specified and directed.
S&F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail MS frame shall be covered with heat moulded plain / coloured PVC "C"channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the styles & rails with suitable PVC sheet beading and jointed togeather with solvent cement complete all as specified and directed.
S&F for framed brackets for chajjas of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. not exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Dismantling of boarding, any description, fixed in any position with nails complete all as specified and directed.
S&F for 18/19mm block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face and board fixed to timber/steel frame work with screw including if any damaged/broken of existing surface during the fixing arrangement of cabinet and making good existing surface with the same material complete all as specified and directed.
S&F extra over rates of block board or veneered particle board for external teak wood lipping, 6mm thick fixed with nails on 18/19 block board complete all as specified and directed.
S&F for 12mm thick plywood No 7 grade veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces fixed with screws as cupboard shutter to timber/steel frame work complete all as specified and directed.
S&F for extra over rates of block board or veneered particle board for external teak wood lipping, 6mm thick fixed with nails on 12mm thick plywood complete all as specified and directed.
S&F for 100mm long hasp and staple, mild steel, wire type, aluminium anodised, including bolt to hinges plate and fixed with screws complete all as specified and directed.
S&F for 30mm width of flap, continous (piano) hinges of mild steel, bright finish or electro galvanised with flap fixed with steel screw complete all as specified and directed.
S&F for stainless steel clip on soft close clip on 3D hydraulic concealed hinges for full overlay door as kitchen cabinet complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of redoxide priming complete all as specified and directed.
S&F 100mm size Stainless steel butt hinges premium welded complete all as specified and directed.
S&F aluminium tower bolts 150 mm long and fixed with steel screws complete all as specified and directed.
S&F aluminium bow handle 150 mm long and fixed with steel screws complete all as specified and directed.
S&F alluminium anodised handles 100 mm long fixed to Cupboard etc complete all as specified and directed.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F 150 mm floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring complete all as specified and as directed.
S&F 300 mm mild steel ordinary rat tail spring including roller and roller plate complete all as specified and directed.
M&L for Cutting chases, pinning in, making good to facings where required for brick wall and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
Taking up or down existing steel water tubing of 15mm bore alongwith connections fixed/laid in any situation, complete all as specified and directed.
All as per item No 63.00 here-in-before but 20 mm bore tubing.
M&L for GI steel water tubing, 15mm bore, medium grade, galvanized with all fittings and fixed to walls and celling or laid in floor, complete all as specified and directed.
All as per ser item No 65.00 here-in-before but 20 mm bore tubing.
S&F in repair stop valves, fancy type, CP cast copper alloy with long shank and cup (concealed type ), screwed both ends for 15mm bore of iron pipe or for union and fixed complete all as specified and directed.
S&F in repairs gun metal gate valve of 20mm dia with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S&F in repairs bib taps, fancy type CP cast copper alloy with capstan head screwed for 15mm bore of iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repairs stop valves/angle cock, fancy type cast copper alloy, screwed down, high pressure, with capstan head, screwed both ends for iron pipe or for unions and fixed fixed complete all as specified and directed.
S&F in repairs vitreous china wash basin, white/ coloured, flat back, size 550x400mm including PTMT waste fittings, 32mm bore size etc. and making good disturbed surfaces to match with the existing complete complete all as specified and directed.
S&F in repairs pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe etc complete all as specified and directed.
S&F brass CP mixer for mixing hot & cold water screwed down high pressure with capstan head screwed for iron pipe bore 15 mm complete all as specified and directed.
S&F low density polyethylene (LDPE) pipes 32mm bore of pressure rating 6 kg/sqcm complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F 20mm dia Nipple suitable for HDPE water tank. (Minimum weight 20mm-45gms) complete all as specified and directed.
S&F for 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe incl dismantling existing water storage tank complete all as specified in SSR Part-I complete all as specified and directed.
S&F in repairs vitreous china squatting pan, Orissa pattern, size 580x440mm white/ coloured with integral foot rests including flus pipe and connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete all as specified and directed.
S&F in repairs PVC 10 ltr capacity valveless syphonic action type, flushing cictern, low level, white/ coloured with inlet, ball valve, float and handle including brackets and connection to pipe etc. complete all as specified and directed.
S&F in repair 125 mm chromium plated shower rose with or without swivel joints any size including fixing to steel pipe or union complete all as specified and directed.
S&F for towel rail, 20mm dia, brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed to walls with steel screws and wooden/rawl plugs as in repairs complete all as specified and directed.
S&F in repairs stainless steel soap dish (not less than 1mm thick) of type as directed, fixed to walls with chromium plated brass screws with wooden/rawl plugs complete all as specified and directed.
S&F in repair sinks made of stainless steel 1mm thick kitchen sink with drainage board inlcuding stainless steel waste coupling and PVC waste pipes, washers including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm complete all as specified and directed.
Dismantling upto 75/100mm of cast iron, PVC/AC/Cement concrete pipes, jointed in cement mortar and taking out from wall/trenches complete all as specified and directed.
S&F 75mm dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls or laid in trenches complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring jointsfixed to walls or laid in trenches complete all as specified and directed.
S&F 75mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F 110 mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F 75mm dia Junction single (Single or double T) equal or unequal complete all as specified and directed.
S&F 110mm dia Junction single (Single or double T) equal or unequal complete all as specified and directed.
M&L PVC (SWR) floor trap 75 mm, plain with PVC grating including jointing with solvent cement etc.,complete all as specified and directed.
S&F in repairs 20-25 mm dia, chromium plated, steel drapary curtain rod with bracketes including necessary drilling holes and fixing with rawl plug and suitable screw in wall including designer dom for curtain rod complete all as specified and directed.
M&L for 15 mm thick rendering over concrete surface of sunken floor in CM 1:3 on wall as well as sunken floor finished even and smooth without using extra cement using WPC complete all as specified and directed. Note:- WPC will be measured and paid separetely.
M&L for water proofing treatment to RCC sunken floor including wall comprising with the following course of treatment/ specifications form bottom to top:- (a) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.6 kg per sqm over a coat of bitumen primer @ 0.40 ltr per sqm including preparation of roof surfaces complete all as specified and as directed. (b) APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface, membrane is laid by torch application complete all as specified. Note:- (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions. (ii) A minimum overlap shall be not to be less than 150mm of polymeric membranes and sealed all overlaps and joints as manufacturer's instructions. (iii) All CI/PVC traps in sunken slabs to be enclosed with PCC 1:1.5:3(min 15 cm) all round.
M&L for cement concrete (1:5:10) type E-2 using 40 mm graded stone aggregate as in filling in sunkan slab or as in sub base, mass concrete complete all as specified.
Demolition of reinforced cement concrete in any position complete all as specified and directed.
M&L for reinforced cement concrete nominal mix (1:2:4), type B1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use & wastef formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) rough surfaces of concrete complete all as specified and directed.
S&F for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for shotcreting average thickness 50 mm in RCC columns, beams and slab etc. (with mix minimum cement content of 350 Kg per Cum, M-25). Concrete having the specified minimun characterstic compressive strength (with ordinary portland cement, coarse sand and graded stone aggregates of 6 mm maximum size in proportion as per design criteria) incl the cost of centering and shuttering at edges and corner etc as directed by Engr-in-Charge incl chipping of unsound/week concrete mateial 50 mm average thickness from slabs, beams/columns etc with mannual chiesels or stenderd power driven percussion type or of approved make incl tapering of all edges, make square shoulder of cavities incl cleaning the exposed concrete surface and reinforcement with wire brushes and throughly washing with water and allowing it to dry etc incl removel of rust by applying approved rust remover chemical and the coating with Dr Fixit epoxy zinc primer @ 6 Sqm per Litre at DFT of 100 micron as per specification, applying the SBR Latex based bonding agent on each layer of the shootcreting work of Dr Fixit Pidicrete URP on the entire surface complete all as directed including 5 mm thick cement plaster in CM (1:3) finished even and smooth without using extra cement including removing rubbish material from building and thrown in low lying empty area at any distance upto 500 metres from the site complete all as specified and directed. Make:- Sika/Fosroc/Pidilite or Techno commercial equivalent make approved by GE in writing from E-in-C's approved list. Note : (i) Complete treatment to be executed by approved applicator. (ii) hard drawn steel wire fabric to be paid seperately.
Supply and fixing hard drawn steel wire fabric not exc 4 kg/sqm cut to lengths, wire mesh to be fixed and firmly anchored to the concrete surface by means of 'L' shaped mild steel shear key welded with existing reinforcement including cost of material, labour, tools and plants incl welding/L-clip/tying with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
S&F for 0.80mm thick, mild steel, plain black sheet as, covering to door shut ters, covering to door chowkats (frames), chullah hoods, water tanks, water troughs, ducts, urinal troughs and funnels, etc. cut to size edges beaded if directed,holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. complete all as specified and as directed.
M&L for cleaning the blockage of bathroom/kitchen by cleaning the nanhi traps / gully traps of all the mud / sludge and getting out washing throughly traps, CI waste pipe by opening the cleaning eyes and depositing the sludge in a pit of suitable size at a distance not exceeding 100m from the gully trap and covering the same with the soil obtained from excavation of pit including excavation and earth work complete all as specified and directed.
Taking down carefully aluminium / copper point wiring with surface/ concealed PVC conduit or wooden batten ( light, fan, socket, bell or power ) including sunk in cast iron / pressed steel terminal boxes except fitting such as switches, ceiling roses, lamp holders, sockets, regulators, call bell, light fitting any sketch etc and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
M&L for point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor FRLS cable 1100 volts grade drawn into and including concealed rigid non mettalic PVC conduit medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes,conceled in wall of make & maching the existing surface ) with 2.8 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators, metal flush box and white sheet cover of any module as required at site etc and 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :-
One light point/fan point controlled by one switch
One light point controlled by two way switch
One socket outlet 5 Amps controlled by one switch on the same board.
One socket outlet 5 Amps controlled by one switch on independent board.
One bell / buzzer controlled by one bell push.
All as per item No. 106.00 here-in-before but 2.5 sq mm multi stranded copper conductor cable for one 15 Amps socket outlet controlled by one switch on independent board and 1.5 sq mm PVC insulated multisranded copper conductor cable as continuous earth wire complete all as specified and directed.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP/DP 10A- 20 Amps with complete accessories all as specified and as directed and directed as per site requirement.
Material and labour in repairs for sub main wiring with two single core 4.0 sqmm multi stranded copper conductor, FRLS PVC insulated, unsheathed cable including rigid non metallic PVC conduit medium grade, ISI marked, 20 mm dia for sub main wiring including 4.0 sqmm FRLS PVC insulated and unsheathed stranded copper conductor as earth wire in concealed in wall of make & matching the existing surface make & matching the existing surface and making good to the disturbed surfaces to match the existing surfaces complete including taking down existing unserviceable submain of any size all as specified and directed. Note:- Two runs of 4.0 sqmm copper conductor cable, one run of 4.0 sqmm copper conductor and one run of PVC conduit will be measured as one unit.
S & F ding dong bell AC, 240 volts, single pole, complete all as specified and directed.
S&F ceiling rose surface bakelight two to three terminal all as specified and directed.
S & F modular Bell push 6A 1 module complete all as specified and directed.
S & F modular switch 1 way 6A, 240 volts 1 module complete all as specified and directed.
S & F modular switch 2 way 6A, 240 volts 1 module complete all as specified and directed.
S & F modular switch 1 way 16A, 240 volts 1 module complete all as specified and directed.
S & F modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
S & F modular socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
S & F modular fan step regulator, 240 volts 2 module complete all as specified and directed.
Supply and fixing Lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F 15 Watt LED bulb, in white colour with maximum Lumen output (850 lm) and colour temp 3000 K, complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F LED light fitting 10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Taking down energy meter/main switches of any size after disconnecting supply and kept in safe custody, taking down & remove the old wooden meter box from site, plastering the existing disturbed wall surface including colour wash and refixing the Meter/Main Switches again on new wooden board of required size as per site incl painting of the board with connection complete all as specified and directed.
Taking down MCB DBs including MCBs of all sizes after disconnecting supply complete all as specified and directed.
S & F sheet metal enclosure MCB DB 4 way tripple pole and neutral 415 volts factory made double door flush type complete all as specified and directed.
Supply and fix for sheet metal enclosures for SPN DB's 240 volts, factory made double door flush type, IP-42 protection and all as per IS-8623, made from sheet metal 8 way 200 Amps rated bus bar to be fixed with wall all accessories complete all as specified and as directed.
S & F MCB, single pole 240 volts 6 to 32 Amps complete all as specified and directed.
S & F MCB, double pole 240 volts 16 to 40 Amps complete all as specified and directed.
S & F MCB, TPN ,63 Amp 440 Volts complete all as specified and directed.
M&l for earthing complete with glavanised steel earth plate elactrode 600x600x6.0 mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below ground leves) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nut, bolt, check nut and washer of galvanised iron or of steel, earth lead protected by 15 mm dia GI pipe light grade watering pipe 20 mm dia GI light grade, GI wire meshed funnel alternate layer of charcoal and salt PCC chamber, reassed for and including RCC cover including all necessary excavation and earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 5 of MES SSR Pt-I 1991 print all as specified and directed. Note:- (i) Item of earthing includes cost of excavation, removing, PCC chamber, 15mm bore medium grade GI protection pipe (7.5 m long) for earth lead any variation in length shall be adjusted through deviation order based on SSR rates enhanced by 25%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of Engr-in Charge.
Supply and fixing LED Bldg/street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and GI pipe 40 mm dia, light grade for mounting bracket bent to shape 1.50 RM and fixing arrangement with two Nos of MS clamps set, nut bolts, washers of suitable size complete all as specified and directed.
Materials & labour in replacement of 1100 volts grade heavy duty XLPE cable of size 25 Sqmm 3.5 core, passing through GI pipe with aluminium conductor stranded polyethylene insulated, conductor served with and including sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete including taking down existing unserviceable UG cable of any type and size all complete all as specified and directed.
Excavation in trenches in any type of soil (loose/ hard) not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out for foundation of pole, laying under ground cables etc and getting out complete all as specified and directed.
M&L sand filling in trenches for cable cushioning with clean, dry and unwashed sand free from sharp particles including gently punning around cable complete all as specified and directed.
M&L for bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all as specified and directed.
Returning, filling in with the earth obtained from above item including spreading, levelling, watering and well ramming in layers and not exceeding 25 cm in layer complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 Mtr and deposting where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
M & L of GI pipe, light grade, 50mm dia bore with all fittings and fixed complete to wall, to pole or laid in trenches and road crossing complete including taking down unserviceable GI pipe of any size complete all as specified and directed.
Taking up or down old unserviceable GI pipe 25mm dia with all fitting laid in trenches/on wall /floor /ceiling with clamps complete all as specified.
All as per ser item no 140.0 here-in-before but 20mm dia complete.
All as per ser item no 140.0 here-in-before but 15mm dia complete.
Supply & fixing Galvanized iron water tubing, 25mm dia, medium grade, with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc. laid in trenches / fixed to walls and ceilings or laid in floors, complete all as specified and directed.
All as per ser item no 143.0 here-in-before but 20mm dia complete.
All as per ser item no 143.0 here-in-before but 15mm dia complete.
M&L 25mm dia, Gun metal, globe or gate valves class -2 with iron wheel head , screwed both ends for iron pipes and fixed complete all as specified and directed.
All as per ser item no 146.0 here-in-before but 20mm dia complete.
All as per ser item no 146.0 here-in-before but 15mm dia complete.
Cutting existing water supply main line in position for insertion of specials / fittings viz Tee etc. of suitable size for making branch connection including testing after completion complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 90681.00
pyarelal galar (BID ID -3202511)
TANUJ CONST. CO. (BID ID -3200749)
M/S HARSH VIKAS GALAR ENGINEERING (BID ID -3197858)
M/s VIKAS TRADERS (BID ID -3203038)
PK CONSULTANT (BID ID -3197000)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .