Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable bid | |
| 2 | L2₹39.6 L+₹1.8 L (4.79%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹41.8 L+₹4.0 L (10.6%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance Being other than L1 |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
29 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey IDSE SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
ADDN ALTN OF BLDG NO P-78 AT HQ NORTHERN COMD UNDER GE (SOUTH) UDHAMPUR
2022_MES_523712_1
CWE/U(S)-30/2022-23
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (SOUTH) UDHAMPUR
₹78,000
12 Jul 2022
12 May 2022
1 Jul 2022
12 May 2022
29 Jun 2022
17 Jun 2022
60 days
Amount
Pre-painted coloured corrugated profiled Galvalume/Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513(AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397),as in roof covering/clading to wall fixed with self taping screws, colour/exterior coat of silicon modified polyster/ BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer,all fixed with galvanised self drilling self tapping fastener(12-14x55 with EPDM seals), complete all as specified and as directed by Engr-in-Charge.
Pre-painted coloured plain steel profiled Galvalume/Zincalume sheet with Min 0.50 mm TCT with BTM of 0.45mm thick conforming to IS-513(AZ-150 GSM, Al Zn alloy metallic coating 550 MPA yield stress as per AS-1397) as roof ridge colour/exterior coat of silicon modified polyster/BHPxRW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer ,all fixed with Galvanised self drilling self-tapping fastener (12-14x55 with EPDM seals) complete all as specified and as directed by Engr-in-Charge.
Mild steel Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails guides for sliding doors, and vertical posts of pipes sections fixed with angle cleats or other connecting plates, Fe-410-W (Gde - E -250) Quality 'A', complete all as specified and as directed by Engr-in-Charge.
Rolled mild steel in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410-W, de E-250 Quality 'A', complete all as specified and as directed by Engr-in-Charge.
Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.
Mild steel, 1.25mm thick plain, Plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) complete all as specified and as directed by Engr-in-Charge.
Providing cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, roof padding, kerbs not provided for including weathering, slightly rounded or chamfered angles including necessary formwork complete all as directed and specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-Charge.
75mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base to floor, complete all as specified and as directed by Engr-in-Charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregates) as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement complete all as specified and as directed by Engr-in-Charge.
Vitrified tiles (double charged) of 10mm thick any colour (area of each tile exceeding 0.42 sqm but not exceeding 1.0 sqm) as in floors jointed in cement slurry and pointed in white or coloured cement to match the existing surfaces over and including 15 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed by Engr-in-Charge.
All as per serial item No. 12.00 here in before but on vertical surfaces as in skirting/dado over and including 10 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engr-in-Charge.
Glazed coloured ceramic jointfree/rectified tiles of size 600x300mm / 450x350mm / 600x600 and 6 to 7mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match with the color of tile etc., over and including 10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3 finished rough for receiving tiles, complete all as specified and as directed by Engr-in-Charge.
18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and polishing over and including 15 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engineer-in-Charge.
Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement for consealing the GI & PVC pipes n exc 15m girth , complete all as specified and as directed by Engr-in-Charge.
Rounding to edges of stone slabs one edge double moulding), such as in steps, cooking platform, and other similar situations including mirror finish polishing complete all as specified and as directed by Engineer-in-Charge.
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
4mm thick Cement fibre E-board (designer false ceiling) of size 600mm x 600mm panel conforming to IS 14862 type B category three including GI frame work with size of grid 605mm x 605mm including all accessories and GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 to 30 mm and web of 27 mm fixed to surrounding wall using screws at 452 mm C/C, channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45mm suspended from soffit at approx 900mm C/C with GI cleat and steel expansion or suitable hanging from soffits/trusses/bracket supporting hanger compressing of GI wire, fibre E-board fixed to GI grid work with screws and applying to coats of distemper and one coat of primer applying on new surfaces, the fibre sheet should be fire resistant, water resistant, termite resistant, environment friendly & 100% asbestos free, complete all as specified and as directed by Engr-in-Charge.
RCC M-25 Design mix, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge. Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified and as directed by Engr-in-Charge.
Welding in repairs exc 2 & but n. exc 5mm in length (girth) and welded thickness not exc 9mm but not exc 20mm, complete all as specified and as directed by Engr-in-Charge.
Running welding in repairs and welded thickness not exc 9mm but not exc 20mm, complete all as specified and as directed by Engr-in-Charge.
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions etc, square, ractangular or polygonal, to obtain rough finished flat surface of concrete complete all as specified and as directed.
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified and as directed by Engr-in-Charge. Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
RCC M-25 Design mix, using 20mm graded crushed stone aggregates, Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like, complete all as specified and as directed by Engr-in-Charge. Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
Use and waste of form work to fins, louvers, fascia etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
Use and waste of form work to sides and sofits of floor or roof beams, beams haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc to obtain rough finished flat surface of concrete complete all as specified and as directed by Engr-in-Charge.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
TMT mild steel bars, 6-8mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and including binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and as directed by Engr-in-Charge.
TMT mild steel bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and includingMS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan to any radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Preparation of new plastered/ unplastered surfaces of wall applying two coats of plastic emulsion paint over and including a coat of primer including wall care putty 2mm thick primer, complete all as specified & directed by Engr-in-Charge.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of weather proof exterior emulsion over coat a primer upto G+2 floor height, complete all as specified and as directed by Engr-in-Charge.
3 mm thick a layer of wall care putty (JK Birla) including preparation of new plastered/ unplastered surfaces of wall, complete all as specified & directed by Engr-in-Charge.
3 mm thick a layer of wall care putty (JK Birla) including preparation of new plastered/ unplastered surfaces on ceiling, complete all as specified & directed by Engr-in-Charge.
Preparing newly plastered or unplastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of ceiling 3mm thick wall care putty with one coat of alkali resistant primer, complete all as specified and as directed by Engr-in-Charge.
Complete removal of existing treatment surfaces of wall and applying two coats of plastic emulsion paint over and including a coat of primer including wall care putty 2mm thick primer, complete all as specified & directed by Engr-in-Charge.
Preparation of surfaces by complete removal of existing treatment from old decorated plastered or unplastered surfaces of wall and applying two coats of weather proof exterior emulsion paint (Apex Ultima) over one coat of primer of any description as approved and as directed by Engr-in-Charge.
Preparation of surfaces by complete removal of existing treatment from old decorated plastered or unplastered surfaces of walls and applying two coat of oil bound distemper over a coat of primer, complete all as specified and as directed by Engr-in-Charge.
Complete removal of existing treatment and applying two coats of cement based paint on old decorated or undecorated wall surface, complete all as specified and as directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt. ) , complete all as specified and directed by Engineer-in Charge.
Description all as per item No 47 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290 Gde-E-165, complete all as specified and as directed.
Preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide/zink chrome primer complete, complete all as specified and as directed by Engr-in-Charge.
2nd class hard wood as in plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed by Engr-in-charge.
18/19 mm thick block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame work, as in kitchen cabinet, cub boards, etc including 6mm thick teak wood beading all around, complete all as specified and as directed by Engr-in-Charge.
0.9 mm thick decorative laminate type -1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructuions complete all as specified and as directed by Engr-in-Charge.
S&F in stainless steel catcher of superior quality, complete all as specified and as directed by Engr-in-Charge.
Mild steel cold rolled butt hinges (ISI Marked) 'Medium weight' 75 mm size, fixed to steel/angle iron frame by welding , if required complete all as specified and directed by Engr-in- Charge.
75 mm size extruded aluminium alloy handles (ISI Marked), fabricated type., anodised, complete all as specified and directed by Engr-in- Charge.
Continuous (piano) hinges width of flaps (when open) 30 mm, mild steel, bright finish or electrogalvanised, complete all as specified and directed.
20 mm dia MS powder coated fancy type tubular curtain rods with bracket fixed to wall with suitable screws and end bulb all as per approved design/colour/pattern, complete all as specified and as directed by Engr-in-Charge
BLANK
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, complete all as specified and as directed by Engr-in-Charge.
Gun metal globe or gate valve with iron wheel head, screwed both ends of size 20mm , complete all as specified and as directed by Engr-in-Charge.
Viterous china wash basin, white, counter top oval shape back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 incl PVC waste pipe 32mm dia & CP grating with holes with pedestal of china ware complete, all as specified and as directed by Engr-in-Charge.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 10mm thick plastering in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric five layred APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.5 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm & including two coats of bituminous Aluminium paint, complete all as specified and as directed by Engr-in- Charge. Note :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in roof padding, leveling course, complete all as specified and as directed by Engr-in-Charge.
12mm thick toughened glass as in railing, partition fixed type including necessary fixings such as silicon gell or other fixing clips clamps, complete all as specified and as directed by Engr - in - charge.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed by Engr - in - charge.
Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing, glazing pins/aluminium beading, etc. including powder coating of thickness minimum 50 micron, complete all as specified and as directed by Engineer-in-Charge. Note:- Powder coated aluminium coating colour shall be approved by GE.
S&F aluminium composite panel (ACP) of 6mm thick HPL sheet, aluminium cover sheet 0.5mm thick, panel length 2240mm and 1220 mm, coated mirror glossy finish/ Natural wood finish of approved colour, pattern & design & as required shape like rectangular, trapezoidal or tapered curved shape ( colour, shade, texture as per sample kept in GE office) with aluminium beading and EPDM rubber complete all as specified and as directed.
Powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc., complete, all as specified and directed by Engr in Charge.
12mm thick Prelaminated particle board, termite proof, chemically well pressed, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, as in kitchen cabinet, cub boards, etc including 6mm thick teak wood beading all around complete all as specified and as directed by Engr-in-Charge.
Supply only Integral water proofing compound, complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor wiring in and including PVC concealed conduit (ISI marked) 20mm dia and over, medium grade and all accessories for one light / fan controlled by one switch suitable for pressed GI terminal boxes (modular type) of required modules concealed on walls including inner and outer sheet for fixing of modular switches/socket/ regulator etc along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified & directed by Engr-in-Charge. Note: (i)Modular metal flush boxes & cover plates are deemed to be included in quoted rates. (ii)Cutting, chases and making same the wall patches after laying the wire and conduits using putty, whitewash and distemper.The surface shall be made smooth using putty and should match exactly with the existing wall finish.The cost of this aspect is deemed to be included in quoted rates.
Description all as per item No 74 above but 05 Amp socket outlet controlled by one switch on independent board .
Description all as per item No 74 above but 05 Amp socket outlet controlled by one switch on same board with other switch.
Description all asper item No 74 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLSH cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Switch piano , single pole,1 module, one way ,06 Amp (modular type) , complete all as specified and as directed by Engr-in-Charge.
Switch piano , single pole,1 module, one way ,16 Amp (modular type) , complete all as specified and as directed by Engr-in-Charge.
Modular bell push single pole one way 6 Amps 1 module type complete all as specified and directed by Engr- in-charge
Socket outlet, 2 in 1, 3 pin 06 Amp flush type modular type, complete all as specified and as directed by Engr-in-Charge.
Modular socket, 6/16Amps, 2/3 pin combined 2 module, complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Bell (ding dong type), AC electronic type, 230 volts, single pole ,fixing in repairs, complete all as specified and as directed by Engr-in-Charge.
Modular type stepped type fan regulator 120W, 230V 50 C/S, Deluxe 2 Modular electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosure single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 5 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver , fixed in repair, complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engr-in-Charge.
Environmental friendly, energy saving, surface mounted, decorative LED 9/10 Watt Bulk head luminaire, with integral electronic LED driver with APFC and lower THD, fixed in repair, Output complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following :- (a) Housing of Light fitting : Die Cast Aluminium (b) Diffuser : Polycarbonate UV protected diffuser (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 900 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4kV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
LED decorative down light fitting/ recess mounted panel (2' x 2') surface mounted lighting fixture 36 Watt LED, with diffuser, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED (Make of LED shall be Cree/Nichia/Osram) complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting, fixed in repair, complete all as per the directions of Engr-in-Charge.
New generation energy saving and environmental friendly long life LED street light of 30 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, fixed in repair, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection: Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Street light Bracket complete made of GI pipe 32mm bore, light grade of suitable size, 1.2m long bent to shape as per site requirement alongwith MS flat iron clamps with nuts, bolts, washers including grouting the same with wall, fixed in repair, complete all as per the direction of Engg-in-Charge.
Supply and fixing sheet metal enclosures for DBs when MCCBs to be used double door DB VTPN 4 ways, vertical type, including 125 Amps MCCB, 25 kA, 415 volts with 400 Amps rated bus bar and neutral link including chases wall for fixing DB and making good disturbed wall surface to match with existing specifications, fixed in repair, complete all as specified and directed by Engr-in-Charge. (Including all PCC & cementing work for installation of TPN DB to wall).
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications, fixed in repairs, complete all as specified and as directed.
MCB SP, 10 to 40 Amps, 'C' series 10 KA 240 Volts including providing aluminium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SPN, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 10 Sqmm ( 2x10 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 10 Sqmm (2x10sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 99 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Exhaust fan AC single phase 230/240 V of size 300mm sweep with louver speed 900-950 RPM power input 50-55 W, Heavy duty, complete all as specified and as directed by Engr-in-Charge.
Supply, laying and testing of XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 25 sqmm 3.5 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
Supplying, installing, connecting, commissioning and testing of AC hi wall split unit air conditioner reversible type four star rating indoor and outdoor unt complete with cordless remote control unit and with built air ionise and plasma filter for better indoor air quality capacity 2 Ton with standard assessores induding MS framework installation of outer wall side, including making required hole in wall for passing of cooling pipe/ cable and making good damaged portion of wali/ floor/ roof in CM 1:4 complete all as specified and as directed by Engr-in-Charge.
Supplying, installing, connecting, commissioning and testing of Voltage stabilizer for automatic operation, single phase copper wiring naturally air cooled indoor type & designed for input votage 110 to 270 V output voltage 230 V. With accuracy + 2.5% and capacity 5KVA complete all as specified and as directed by Engr-in-Charge.
Note:- For items 01 to 110 The quoted rates shall be deemed to include for items of surfaces finshes of Bldg upto G+2 height above all external/ internal surface finishes and include the following:- 1. Use of all scaffolding, trestles, ladders, cradles etc. necessary for execution of work and protective measures. 2. Removing of nails, making good holes, cracks etc. 3. Work in patches, and in narrow/ widths, bands, cornices, plasters etc and cutting in edges to line where necessary. 4. Spreading and removing covering to doors, windows, floors, fitting etc to protect them from splashes. 5. Removing and replacing furniture, movable cupboard, chicks, blinds, etc washing floors, cleaning glass, joinery, electric fittings, wiring, etc of drops and splashes and leaving premises, clean and tidy followed.
vijay constrction co
SINGH CONST CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .