| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.2 L+₹77,433 (22.3%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹4.4 L+₹94,690 (27.3%)Rejected-Finance | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | WEATHER MAKERS INDIA L3 | SKY DECORATIONS PRIVATE LIMITED L2 | MODERN REFRIGERATION AND ELECTRICAL WORKS L1 |
|---|---|---|---|---|---|---|
| 1.00Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC.. (O-General/Mitsubishi Heavy Duty). | ||||||
| 1.01 | Cooling Capacity- 8.8 kW (Minimum) , Air Flow Rate:800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) | 3 | nos. | 1,05,000 ₹3,15,000 | 1,00,000 ₹3,00,000 Lowest | 1,00,000 ₹3,00,000 Lowest |
| 2.00Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | ||||||
| 2.01 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 50 | mtrs | 250 ₹12,500 | 300 ₹15,000 | 230 ₹11,500 Lowest |
| 2.02 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 50 | mtrs | 550 ₹27,500 | 500 ₹25,000 Lowest | 525 ₹26,250 |
| 3.00 | S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of above AC machines.
i) 2.5 sqmm, 3/4 core copper cable (FRLS type) | 52 | mtrs | 185 ₹9,620 | 195 ₹10,140 | 165 ₹8,580 Lowest |
| 4.00 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. | 75 | mtrs | 85 ₹6,375 Lowest | 85 ₹6,375 Lowest | 125 ₹9,375 |
| 5.00 | Add. G.S.T.@ 18% on total value. | 1 | Item | 66,779 ₹66,779 | 64,173 ₹64,173 | 64,027 ₹64,027 Lowest |
| 6.00 | Add. LWC.@ 1% on total value | 1 | Item | 4,378 ₹4,378 | 4,207 ₹4,207 | 4,197 ₹4,197 Lowest |
Tender Value
Refer Docs
EMD Value
₹8,500
Closing Date
5 Jun 2026, 1:00 pmClosed
AE/KRESD/PWDte
Office of The Assistant Engineer, Kolkata Raj Bhavan Electrical Sub Division, P.W.Dte., 2 Larkin Lane, Kolkata-700062
Supply and Fixing of Air Conditioning machines at Governors Study at First Floor of Main Building Lok Bhavan Kolkata.
2026_WBPWD_5014395_1
WBPWD/AE-KRESD/NIQ-02/2026-27
Open Tender
ELECTRICAL WORKS M/R
Item Rate
15 days
Kolkata Raj Bhavan
Please refer Tender documents.
4 documents required · 4 mandatory
₹8,500
1 Oct 2026
22 May 2026
8 Jun 2026
23 May 2026
5 Jun 2026
23 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC.. (O-General/Mitsubishi Heavy Duty). | |||||
| 1.01 | Cooling Capacity- 8.8 kW (Minimum) , Air Flow Rate:800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) | 3 | nos. | - | - |
| 2Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | |||||
| 2.01 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 50 | mtrs | - | - |
| 2.02 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 50 | mtrs | - | - |
| 3 | S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of above AC machines.
i) 2.5 sqmm, 3/4 core copper cable (FRLS type) | 52 | mtrs | - | - |
| 4 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. | 75 | mtrs | - | - |
| 5 | Add. G.S.T.@ 18% on total value. | 1 | Item | 100 | ₹100 |
| 6 | Add. LWC.@ 1% on total value | 1 | Item | 100 | ₹100 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
2911_ii.pdf
Tender Documents • 0.50 MB
BOQ_5082457.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .